Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PR 19462: PURCHASE OF SENSUS METERS FOR UTILITY OPERATIONS
J City ofP.R. No. 19462 \4, ---...,..- -. �� 10/26/16 ds nrt rthur 7exus INTEROFFICE MEMORANDUM UTILITY OPERATIONS DEPARTMENT-ADMINISTRATION Date: October 26, 2016 To: Brian McDougal, City Manager From: Jimmie Johnson, Ph.D.,Assistant City Manager RE: Proposed Resolution No. 19462 Nature of the Request: The City has standardized on the Itron radio-read system (sole supplier for AMR meters), but which can be easily adapted to our existing large Sensus meters with the addition of an inexpensive Universal Transmitter. These large Sensus meters offer a superior product that is routinely less expensive in many applications. Aqua-Metric Sales Company is the only Texas distributor for Sensus meters and should be considered a sole source. Fire Service meters measure water used through fire suppression and/or fire sprinkler systems, but in certain large applications can be used for normal water consumption. This award establishes unit prices for various large Sensus meters. Aqua-Metric Sales Company has provided current Not-to- Exceed (NTE) quotes below for such Sensus meters: Item Unit Price 3" Omni T2 Turbo meter, flanged w/test plug $ 1,003.20 3" Omni C2 compound AMR meter, flanged $ 1,436.16 4" Omni T2 Turbo Meter $ 1,924.71 4" Omni C2 compound AMR meter, flanged $ 2,472.36 4" Omni F2 Meter Compact $ 5,560.73 6" Omni C2 compound AMR meter, flanged $ 4,248.69 6" Omni F2 Meter Compact $ 7,390.95 8" Omni C2 Compound Meter $ 6,845.04 8"Omni F2 Meter Compact $11,050.40 10" Omni F2 Meter Compact $15,793.40 3"Fire Hydrant turbo meter w/backflow preventer $ 1,524.56 This procurement is exempt from the bid process under Texas Local Government Code Section 252.022, (a) (7) (D), captive replacement parts or components for equipment. P.R. No. 19462 10/26/16 ds Staff Analysis, Considerations: Water Distribution crews will install meters when needed. Recommendation: I recommend that the City Council approve Proposed Resolution No. 19462 to authorize the execution of a contract with a projected budgetary impact of$280,000, for Large Compound& Fire Service Water Meters to Aqua-Metric Sales Company, Schertz, Texas, for the Utility Operations Department. The distributor is located in Schertz, Texas. Budget Considerations: This equipment will be maintained in our Warehouse inventory and charged to the appropriate account when used; #410-1253-532.35-00 for routine replacement meters/equipment, #414- 1621-532.85-00 for new customer meters/connections. P. R. No. 19462 10/26/16 ds Page 1 of 3 RESOLUTION NO. A RESOLUTION AUTHORIZING THE EXECUTION OF A CONTRACT FOR THE PURCHASE OF SENSUS METERS FOR THE UTILITY OPERATIONS DEPARTMENT WITH AQUA METRIC SALES COMPANY OF SCHERTZ, TEXAS, WITH A BUDGETARY IMPACT OF $280,000.00. FUNDS ARE AVAILABLE IN UTILITY OPERATIONS ACCOUNT NOS. 410-1253-532.35-00 & 414-1621-532.85-00. WHEREAS, the Utility Operations Department routinely installs and replaces meters throughout the City; and, WHEREAS, the City Standard for meters includes those as manufactured by Badger Meter and Sensus; and, WHEREAS, Sensus sells its product through distributors exclusive to geographic areas; and, WHEREAS, the current distributor for our area (sole supplier) is Aqua Metric Sales Company; and, WHEREAS,this purchase is authorized by Procurement Policies and Procedures Section 3-105 Sole Source Procurement, b) Compatibility—The product must match an existing brand of equipment for compatibility and is available from only one supplier; and, WHEREAS, this procurement is exempt from the bid process under Texas Local Government Code Section 252.022, General Exemptions (A) (7) (D), captive replacement parts or components for equipment; and, WHEREAS, the sole supplier for quotes has been evaluated by Utility Operations (quote sheet attached as Exhibit"A"),NOW THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PORT ARTHUR: P. R. No. 19462 10/26/16 ds Page 2 of 3 THAT, the City Manager of the City of Port Arthur is hereby authorized and directed to execute, on behalf of the City of Port Arthur, a contract between the CITY OF PORT ARTHUR and Aqua Metric Sales Company, for the unit prices shown in Exhibit "A", with a projected budgetary impact of$200,000, as shown in the contract attached as Exhibit"B"; and, THAT, funding for this material is provided for in the Utility Operations budget; and, THAT a copy of the caption of this Resolution be spread upon the Minutes of the City Council. READ, ADOPTED AND APPROVED THIS day of 2016 at a Regular Meeting of the City Council of the City of Port Arthur, Texas, by the following vote: AYES: Mayor ; Councilmembers: NOES: Derrick Freeman Mayor ATTEST: APPROVED FOR ADMINISTRATION: Sherri Bellard Brian McDougal City Secretary City Manager P. R. No. 19462 10/26/16 ds Page 3 of 3 Dr. Jimmie Johnson, PhD Assistant City Manager APPROVED AS TO FORM: (7 Valecia Tizeno / Clifton Williams, CPPB City Attorney Acting Purchasing Manager APPROVED AS TO THE AVAILABILITY OF FUNDS: t4i Jerry Dale, CPA/CGFO 100 Director of Finance P. R. No. 19462 10/26/16 ds Exhibit "A" (Quote) May 2015 City of Port Arthur Meters & Metering Systems (AMR & Non-AMR) GENERAL INFORMATION These specifications are for the furnishing of Meters and Encoded Registers with a 5 foot wire that has a connector for Itron transmitters, delivered FOB, Water Utilities Service Center, 111 H.O. Mills Blvd., Port Arthur, Texas 77640. All equipment shall be as manufactured by Badger Meter, Inc. or Sensus Metering Systems, as specified below. All meters shall meet AWWA C700. If a vendor offers any additional, optional, or alternate bid items, it should be so noted on the below bid form to be considered a part of the bid. The estimated quantities listed below are for bidding purposes only, as funding allows and does not require the City to purchase these amounts. All meters to register in US gallons. All AMR meters shall include AMR HR-E encoder registers, as specified. In order to provide for field accuracy and pressure testing, certain meters will utilize optional bronze NPT test ports/plugs with caps to cover test ports and stainless steel strainers integral to the meter casing. Please provide unit prices for each of the following bid items: Positive Displacement/Turbo Meters w/bronze chamber and Encoders w/ltron connector Item # Est. Item Unit Total Quantity Description Price 1 400 %" x 3/4" M-25LL bronze meter $136.64 $54,656.00 Alternate - 5/8" x 3/" Sensus SRII with TRPL Encoded Itron ILC Register 2 50 1" x 1" M-55LL bronze meter $212.73 $10,636.50 Alternate— 1" Sensus SRII with TRPL Encoded Itron ILC Register USG 3 5 1'/" x11/2" M-120 bronze, flanged $436.41 $2,182.05 Alternate — 1 1/2" OMNI R2 with TRPL Encoded Itron ILC Register USG 4 10 1W x 11/2" M-120 bronze, flanged w/test plug $440.68 $4,406.80 Alternate— 1 1/2" OMNI R2 with TRPL Encoded Itron ILC Register USG with Test Port 5 5 2" x 2" M-17OLL bronze, flanged $600.26 $3,001.30 Alternate— " OMNI R2 with TRPL Encoded Itron ILC Register USG 6 10 2" x 2" bronze, M-170 flanged w/test plug $604.54 $6,045.40 Alternate— 1 1/2" OMNI R2 with TRPL Encoded Itron ILC Register USG with Test Port 7 400 HR-E Encoder M-25 HR-E W/Itron ILC 5'connector wire For 5/8" M-25LL meter No Bid May 2015 8 50 HR-E Encoder M-55 HR-E W/Itron ILC 5'connector wire For 1" M-55 meter No Bid 9 15 HR-E Encoder M-120 HR-E W/Itron ILC 5'connector wire For 1 1/2" M-120 meter No Bid 10 25 HR-E Encoder M-170 HR-E W/Itron ILC 5'connector wire For 2" M170 meter No Bid 11 2 HR-E Encoder T-200 HR-E W/Itron ILC 5'connector wire For 2" T 200 meter No Bid Turbine/Turbo/Compound/Meters HR-E encoder T-200, HR-E w/itron ILC 5' encoder wire for 2" T-200. Item # Est. Meter Unit Total Quantity Description Price 12 2 2" x 2" T-200 round bronze flanged $810.95 $1,621.90 Alternate — 1 1/2" OMNI T2 with TRPL Encoded Itron ILC Register USG 13 5 2" x 2" T-200 Elliptical bronze, flanged w/test plug $810.95 $4,054.75 Alternate— 1 1/2" OMNI R2 with TRPL Encoded Itron ILC Register USG Fire Line Metering Assemblies (manufacturer as noted below) Shall include UL listed fire service meter, strainer, detector check valve, test ports/plugs with caps to cover test ports and bypass piping, as applicable, for low flow, turbo or positive displacement meter. Also to include HR-E encoder Registers w/ITRON COMPATIBLE CONNECTOR 5' WIRE. Item # Est. Meter Unit Total Quantity Description Price 14 4 3" Omni T2 Turbo Meter w/itron wire $1,003.20 $4,012.80 15 4 3" Omni C2 Compound Meter w/itron wire $1,436.16 $5,744.64 16 5 4" Omni T2 Turbo Meter w/itron wire $1,924.71 $9,623.55 May 2015 17 5 4" Omni C2 Compound Meter w/itron wire $2,472.36 $12,361.80 18 5 4" Omni F2 Compact Meter w/ltron wire $5,560.73 $27,803.65 19 5 6" Omni C2 Compound Meter w/itron wire $4,248.69 $21,243.45 20 5 6" Omni F2 Compact Meter w/itron wire $7,390.95 $36,954.75 21 5 8" Omni C2 Compound Meter w/itron wire $6,845.04 $34,225.20 22 5 8" Omni F2 Compact Meter w/itron wire $11,050.40 $55,252.00 23 5 10" Omni F2 Compact Meter w/itron wire $15,793.40 $78,967.00 Miscellaneous Items Item # Est. Item Unit Total Quantity Description Price 24 5 3" Fire Hydrant turbo meter w/backflow Preventer and HR-E Encoder $1,524.56 $7,622.80 3' OMNI H2 Fire Hydrant Meter with Techno-Check Valve. Sensus Encoded Register and Couplings Bidder: Aqua Metric Sales Company . Name of Company Signature 6700 Guada Coma Drive • Schertz, Texas 78154 Address City State Zip (210) 967-6300 5210) 967-6305 Phone FAX P. R. No. 19462 10/26/16 ds Exhibit "B" (Contract) P. R. No. 19462 10/26/16 ds PURCHASING CONTRACT AGREEMENT FOR SENSUS METERS THIS AGREEMENT is made this the of , 2016, by and between an individual, firm partnership or corporation, Aqua Metric Sales Company, of Schertz, TX hereinafter called "Vendor", and the City of Port Arthur, a municipal corporation organized under the laws of the State of Texas, hereinafter called the "Owner" or "City". WITNESSETH: That for and in consideration of the payments, terms, conditions and agreements set forth herein, Owner and Vendor agree as follows: 1. The term of this Contract shall be for one (1) year from the date that it is signed by the City unless sooner terminated under the provision hereof. The City can terminate this contract at its convenience which includes, but not limited to, funding not being available in any budget cycle with thirty (30) days written notice. 2. The Vendor will provide SENSUS Meters, as delineated and submitted in their proposal dated July 19, 2016. 3. During the term of this Contract, the Vendor will furnish all of the materials and supplies, as stated in the specifications, described as: SENSUS Meters 4. The Vendor agrees to deliver all materials on an as-needed basis during the term of this contract, in a not-to-exceed maximum amount of $200,000.00 in the unit prices as stated the proposal dated July 19, 2016. 5. The term "Contract Documents" means and includes the following: A. Agreement B. Specifications/Proposal C. Notice to Proceed 6. This Agreement shall be binding upon all parties hereto and their respective heirs, executors, administrators, successors and assigns. P. R. No. 19462 10/26/16 ds IN WITNESS WHEREOF, the parties hereto have executed, or caused to be executed by their duly authorized officials, this Agreement in two (2) copies each of which shall be deemed an original on the date first above written. SIGNED AND AGREED to on the day of , 2016. WITNESS: CONTRACTOR: Aqua Metric Sales Company SIGNED AND AGREED to on the day of , 2016. WITNESS: CITY OF PORT ARTHUR: City Secretary City Manager ,4qua A A A Metric Aqua Metric Sales Company 6700 Guada Coma Dr.,Schertz Texas 78154 Phone:(210)967-6300• Facsimile: (210)967-6305 E.er%), City of Port Arthur, Texas City of �'r , �.t Lik Attn: Lonnie Linden w 111 H.O. Mills Blvd ort rth fir port Arthur, Texas 77640 h.tas lonnie.linden@portarthurtx.gov , Request for Quote Meters & Metering Systems (AMR & Non-AMR) Due: July 2016 Primary Contact: Kristy Segarra Manager,Bids&Proposals Phone:(210)967-6300 Email:kristy.segarra@aqua-metric.com Prepared: July 19,2016 sEnsus May 2015 City of Port Arthur Meters & Metering Systems (AMR & Non-AMR) GENERAL INFORMATION These specifications are for the furnishing of Meters and Encoded Registers with a 5 foot wire that has a connector for Itron transmitters, delivered FOB, Water Utilities Service Center, 111 H.O. Mills Blvd., Port Arthur, Texas 77640. All equipment shall be as manufactured by Badger Meter, Inc. or Sensus Metering Systems, as specified below. All meters shall meet AWWA C700. If a vendor offers any additional, optional, or alternate bid items, it should be so noted on the below bid form to be considered a part of the bid. The estimated quantities listed below are for bidding purposes only, as funding allows and does not require the City to purchase these amounts. All meters to register in US gallons. All AMR meters shall include AMR HR-E encoder registers, as specified. In order to provide for field accuracy and pressure testing, certain meters will utilize optional bronze NPT test ports/plugs with caps to cover test ports and stainless steel strainers integral to the meter casing. Please provide unit prices for each of the following bid items: Positive Displacement/Turbo Meters w/bronze chamber and Encoders w/ltron connector Item # Est. Item Unit Total Quantity Description Price 1 400 %" x 3/" M-25LL bronze meter $136.64 $54,656.00 Alternate - 5/8" x 3/" Sensus SRII with TRPL Encoded Itron ILC Register 2 50 1" x 1" M-55LL bronze meter $212.73 $10,636.50 Alternate •- 1" Sensus SRI! with TRPL Encoded Itron ILC Register USG 3 5 VA" x 1'/2" M-120 bronze, flanged $436.41 $2,182.05 Alternate - 1 1/2" OMNI R2 with TRPL Encoded Itron ILC Register USG 4 10 1W x 1W M-120 bronze, flanged w/test plug $440.68 $4,406.80 Alternate- 1 1/2" OMNI R2 with TRPL Encoded Itron ILC Register USG with Test Port 5 5 2" x 2" M-17OLL bronze, flanged $600.26 $3,001.30 Alternate- " OMNI R2 with TRPL Encoded Itron ILC Register USG 6 10 2" x 2" bronze, M-170 flanged w/test plug $604.54 $6,045.40 Alternate - 1 1/2" OMNI R2 with TRPL Encoded Itron ILC Register USG with Test Port 7 400 HR-E Encoder M-25 HR-E W/Itron ILC 5'connector wire For 5/8" M-25LL meter No Bid May 2015 8 50 HR-E Encoder M-55 HR-E W/Itron ILC 5'connector wire For 1" M-55 meter No Bid 9 15 HR-E Encoder M-120 HR-E W/Itron ILC 5'connector wire For 1 1/2" M-120 meter No Bid 10 25 HR-E Encoder M-170 HR-E W/Itron ILC 5'connector wire For 2" M170 meter No Bid 11 2 HR-E Encoder T-200 HR-E W/Itron ILC 5'connector wire For 2"T 200 meter No Bid Turbine/'Turbo/Compound:Meters HR-E encoder T-200, HR-E w/itron ILC 5' encoder wire for 2" T-200. Item # Est. Meter Unit Total Quantity Description Price 12 2 2" x 2" T-200 round bronze flanged $810.95 $1,621.90 Alternate— 1 1/2" OMNI T2 with TRPL Encoded Itron ILC Register USG 13 5 2" x 2" T-200 Elliptical bronze, flanged w/test plug $810.95 $4,054.75 Alternate— 1 1/2" OMNI R2 with TRPL Encoded Itron ILC Register USG Fire Line Metering Assemblies (manufacturer as noted below) Shall include UL listed fire service meter, strainer, detector check valve, test ports/plugs with caps to cover test ports and bypass piping, as applicable, for low flow, turbo or positive displacement meter. Also to include HR-E encoder Registers w/ITRON COMPATIBLE CONNECTOR 5' WIRE. Item # Est. Meter Unit Total Quantity Description Price 14 4 3" Omni T2 Turbo Meter w/itron wire $1,003.20 $4,012.80 15 4 3" Omni C2 Compound Meter w/itron wire $1,436.16 $5,744.64 16 5 4" Omni T2 Turbo Meter w/itron wire $1,924.71 $9,623.55 May 2015 17 5 4" Omni C2 Compound Meter wlitron wire $2,472.36 $12.361.80 18 5 4" Omni F2 Compact Meter w/Itron wire $5,560.73 $27,803.65 19 5 6" Omni C2 Compound Meter wNitron wire $4.248.69 $21.243.45 20 5 6" Omni F2 Compact Meter w/itron wire $7,390.95 $36,954.75 21 5 8" Omni C2 Compound Meter w!itron wire 56,845.04 $34.225.20 22 5 8" Omni F2 Compact Meter w/itron wire $11,050.40 $55.252.00 23 5 10" Omni F2 Compact Meter wiitron wire $15,793.40 $78,967.00 Miscellaneous Items Itern # Est Item Unit Total Quantity _ Description Price 24 5 3' Fire Hydrant turbo meter w/backfiow Preventer and HR-E Encoder $1,524.56 $7.622.80 3' OMNI Hydrant Meter with Tec-- Encoded ec~Encoded Register and Couplings Bidder: Aqua Metric Sales Company . Name of Company Signature 6700 Guada Coma Drive • Schertz, Texas 78154 Address City State Zip {210) 967-6300 210) 967-6305 Phone FAX Aqua AAA 4Metric July 19,2016 KristySegarra-Manager,Bids&Proposals 6700 Guada Coma Drive•Schertz,TX 78154 Phone:(210)967-6300•Fax:(210)967-6305 Email:kristy.segarra@aqua-metric.com www.aqua-metric.com Quote for City of Port Arthur Attention Lonnie Linden Address 111 H.O.Mills Bvd. City,State,ZIP Port Arthur,Texas 77640 Phone: (409)983-8562 Email: lonnie.linden@portarthurtx.gov Quantity Description Unit Price Extended 400 5/8"x 3/4"SRII Meter with TRPL Encoded Itron ILC Register USG $136.64 $54,656.00 SO 1"SRII Meter with TRPL Encoded Itron ILC Register USG $212.73 $10,636.50 5 1 1/2"OMNI R2 Residential Meter with TRPL Encoded Itron ILC Register USG $436.41 $2,182.05 10 1 1/2"OMNI R2 Residential Meter with TRPL Encoded Itron ILC Register USG-With Test Port $440.68 $4,406.80 5 2"OMNI R2 Residential Meter with TRPL Encoded Itron ILC Register USG $600.26 $3,001.30 10 2"OMNI R2 Residential Meter with TRPL Encoded Itron ILC Register USG-With Test Port $604.54 $6,045.40 2 2"OMNI T2 Turbo Meter with TRPL Encoded Itron ILC Register USG $810.95 $1,621.90 5 2"OMNI T2 Turbo Meter with TRPL Encoded Itron ILC Register USG $810.95 $4,054.75 4 3"OMNI T2 Turbo Meter with Itron Inline Connector USG $1,003.20 $4,012.80 4 3"OMNI C2 Compound Meter with Itron Inline Connector USG $1,436.16 $5,744.64 5 4"OMNI T2 Turbo Meter with Itron Inline Connector USG $1,924.71 $9,623.55 5 4"OMNI C2 Compound Meter with Itron Inline Connector USG $2,472.36 $12,361.80 5 4"OMNI F2 Compact Fire Service Meter with Itron ILC USG $5,560.73 $27,803.65 5 6"OMNI C2 Compound Meter with Itron Inline Connector USG $4,248.69 $21,243.45 5 6"OMNI F2 Compact Fire Service Meter with Itron ILC USG $7,390.95 $36,954.75 5 8"OMNI C2 Compound Meter with Itron Inline Connector USG $6,845.04 $34,225.20 5 8"OMNI F2 Compact Fire Service Meter with Itron ILC USG $11,050.40 $55,252.00 5 10"OMNI F2 Compact Fire Service Meter with Itron ILC USG $15,793.40 $78,967.00 5 3"OMNI H2 Fire Hydrant Meter w/Techno-Check Valve,Sensus Encoded Register and Couplings $1,524.56 $7,622.80 This quotation on the product and services named,may be subject to the conditions noted below: Total $380,416.34 1.Net 30 Days to Pay 2.Freight Allow on orders over$5,000 3.All quotes are valid for 90 days from date of quotation 4.Return product may be subject to 25%restocking fee DS-W-SR2-00-00-0312-02-A SR II® Low Lead Meters ■ Displacement Type Magnetic Drive Cold Water Meters Description 5/8" (DN 15mm),3/4" (DN 20mm)and 1" (DN 25mm)Sizes Measurement of cold water where flow is in one /" ' direction only; in residential, commercial and in- 00 'lli► dustrial services. ' „,,WC' a,W„0 0.0 .a H ' ' 7)m, 0 0 0 �0,0 1 W L1,L1 0.,°.IJ Ll W/1��. „...... .t, _CUM�� »*: 5/8”AMR/AMI System Dials Shown Features CONFORMANCE TO STANDARDS tector. Gears are selflubricating, molded The driven magnet is connected to the Sensus SRII Low Lead Water Meters plastic for long life and minimum friction. register gear train. It reduces the piston meet the requirements of NSF Standard No change gears are required for accura- oscillations into volume totalization units 61,Annex F and G and comply with ANSI/ cy calibration. Encodertype remote read- displayed on the register dial face. AWWA Standard C700-latest revision. ing systems are available for all SR II Low Each meter is tested to insure compliance Lead Water Meters.(See other side of MAINTENANCE with AWWA standards. sheet for additional information.) Sensus SR II Low Lead Water Meters are engineered to provide long-term value CONSTRUCTION TAMPERPROOF FEATURES and virtually maintenance-free operation. Sensus SR II Low Lead Water Meters A unique locking system prevents cus Simplicity of design allows interchange- consist of three basic components: main- tomer removal of the register to obtain ability of parts of like size meters, re- case; measuring chamber; and sealed free water. The register can only be re duced parts inventory requirements, and register. Maincases are made of Bismuth moved by breaking the register bonnet. ease of maintenance.The register can be BiAlloy CDA89836 or EnviroBrassTM II removed without relieving the water pres- C89520 with externally-threaded spuds. MAGNETIC DRIVE sure or removing the maincase from the Registers are housed in a bonnet of syn- installation. The SR II Low Lead features a hydrody- thetic polymer. Measuring chambers are namicallycushioned design that elimi-Rocksyn®, a corrosionresistant, tai- lored thermoplastic material formulated nates premature wear of components. p The meter utilizes a patented positive, Tailpieces/Unions for installing the meters for long-term performance and especially reliable drive coupling. The highstrength on a variety of pipe types and sizes are suitable for aggressive water conditions. magnets used will eliminate"drive slip"in available. Maincase bottom plates are available in normal use and also provide adequate Bismuth BiAlloy, EnviroBrass II or, if frost strength to drive remote register units. AMR/AMI SYSTEMS protection is desired, in cast iron or syn- thetic polymer'. Meters and encoders are compatible with OPERATION current Sensus AMR/AMI systems. SEALED REGISTER Water flows through the meter's strainer and into the measuring chamber where it GUARANTEE Hermetically sealed; proven magnetic drives theiston. The h drod namicall drive design eliminates dirt and moisture p y y y Sensus SR II Water Meters are backed balanced piston oscillates around a by "The Sensus Guarantee." Ask your contamination, tampering and lens fog- central hub,guided by the division plate. Sensus representative for details or see ging problems.Standard register includes Bulletin G-500. a straight-reading, odometertype totaliza- A drive magnet transmits the motion of tion display;a 360°test circle with center the piston to a driven magnet located sweep hand; and a low flow (leak) de- within the hermetically sealed register. sEnsus DS-W-S R2-00-00-0312-02-A Page 2 of 2 , . . � Sealed Register A Magnetic i ` ,Coupling . , v Locking IIi�1i� IL i� �B Screx / Direction � of Flow r ?. 4 i.. Bottom Liner A Bottom Plate DIMENSIONS AND NET WEIGHTS Meter Size A B(Direct Read Register) C Width Net Weight' 5/8" 7-1/2" 5.0" 1-3/4" 3-7/8" 4.3 lb. (DN 15mm) (190mm) (127mm) (44mm) (98mm) (1.97 kg) 5/8"x 3/4" 7-1/2" 5.0" 1-314" 3-7/8" 4.4 lb. (DN 15mm X 33mm) (190mm) (127mm) (44mm) (98mm) (2.00 kg) 3/4" 9" 5-1/2" 2-3/16" 4-1/2" 6.4 lb. (DN 20mm) (229mm) (140mm) (56mm) (114mm) (2.90 kg) 3/4"x 1" 9" 5-1/2" 2-3/16" 4-1/2" 6.6 lb. (DN 20mm x 42mm) (229mm) (140mm) (56mm) (114mm) (2.99 kg) 3/4"Short 7-1/2" 5-1/2" 2-3/16" 4-1/2" 6.2 lb. (DN 20mm) (190mm) (140mm) (56mm) (114mm) (2.81 kg) 1" 10-3/4" 6-9/16" 2-7/16" 6-1/2" 11.9 lb. (DN 25mm) (273mm) (167mm) (62mm) (165mm) (5.4 kg) SPECIFICATIONS SERVICE Measurement of potable and reclaim water. METER 5/8"(ON 15mm)size:3/4"(26.44mm)threads NORMAL CONNECTIONS 5/8"x 3/4"(DN 15mm x 33mm)size:1"(33.25mm)threads OPERATING 5/8"(DN 15mm)size: 1 to 20 gpm (0.25 to 4.5 m3/hr) 3/4"(DN 20mm)size:1"(33.25mm)threads 3/4"(DN 20mm)size: 2 to 30 gpm (0.45 to 7.0 m3/hr) 3/4"x 1"(DN 20mm x 42mm)size:1-1/4"(41.9mm)threads FLOW RANGE' 1" DN 25mm)size: 3 to 50 gpm (0.7 to 11.0 m3/hr) 1" DN 25mm size:1-1/4"(41.9mm)threads (All threads are straight pipe,external type,conforming to LOW FLOW 5/8"size: 1/4 gpm(0.06 m3/hr) ANSI B1.20.1 or ISO R228,if specified.) REGISTRATION 3/4"size: 1/2 gpm(0.10 m3/hr) MATERIALS Maincase: Bismuth BiAlloy CDA89836 or (95' .101 5 1 1"size: 3/4 gpm(0.15 m3/hr) EnviroBrass II C89520 MAXIMUM 5/8"size: 7.0 psi at 20 gpm (0.5 bar at 4.5 m3/hr) Register box: Synthetic polymer PRESSURE LOSS 3/4"size: 9.0 psi at 30 gpm (0.6 bar at 7.0 m3/hr) Measuring chamber: Rocksyn® 1"size: 7.3 psi at 50 gpm (0.5 bar at 11.0 m3/hr) Bottom plate: Bismuth BiAlloy CDA89836 Magnets: Plasticized material MAXIMUM Casing bolts: Stainless steel OPERATING 150 psi(10.0 bar) Strainer: Synthetic polymer PRESSURE MEASURING 1 Maximum rates listed are for intermittent flow only.Maximum continuous flow rates ELEMENT Oscillating piston as specified by AWWA are: 5/8"(DN 15mm)-10 gpm(2.3 m'/hr) REGISTER Straight reading,hermetically sealed,magnetic drive. 3/4"(DN 20mm)-15 gpm(3.4 m3/hr) Remote reading unit optional. 1"(ON 25mm)-25 gpm(5.7 m3/hr) STANDARD 10 gallons,1 cubic foot, or 0.01 m3/or 0.1 m3/sweep hand 2 Unless otherwise noted,5/8"size and 5/8"x 3/4"characteristics are identical. METER revolution. 5/8"x 3/4"designates 5/8"with 3/4"connection thread). REGISTRATION 10,000,000 gallons,1,000,000 cubic feet or 100,000 m3 Metric designation is the normal bore x the outside diameter. capacity. 3 See ICE-Opto Register Datasheet or Electronic Register Datasheet for details 8 odometer wheels specifications. sEnsus DS-W-SR2-00-00-0312-02-A Page 3 of 3 IIIIIIIIII PERFORMANCE CURVES SR II Meter 5/8" and 5/8" x 3/4" SR II Meter 3/4" and 3/4" x 1"SR II Meter UA-5833 UA-5834 ACCURACY CURVE U , ACCURACY CURVE - 101- J— tat- ` g 98_ g97 - I- - 1 97- 96- %_ 16 94- AWWA LIMIT 10 1.0- 94- ANNA LIMIT 19 14 y.0- 12-.8- 12 b_ 10- 0 8'.8- 8 .6 / I B-A- _1 /................./......' 8 A-I A ♦ 4- HEAD LOSS CURVE - 2- z s ,) 5 HEAD OSS CURVE _� 5 10 15 5 10 18 20 25 30 - 35 05 1 2 5 10 12,_0 25 30 OS 1 2 9 0.6 1, 2 - - dt.pR ruwrt Ob 1 2 24 6 i 8 -so EAvu.n RATE OF FLOW mamma RATE OF FLOW 1" SR II Meter 3/4" SR II Meter 7-1/2" Laying Length UA-5835 UA-5838 ■E.1■■■LQirL- 3T3IITl311■11.1■■EEE ..U-A.Y U-V 1011111•311111■■■.111111E■■■■■111E111 .' lot M 1W II■■Ma::ns!!�■■■mmM■_ '� g 1W ISI ��.I�__ f1 a 99 ,.111.1.1■■■■.1.111■■■■■ii � 99 .■■■■■■■■■■■■ 97-I ■E■■■■■■E■■■■■EM■■ 991111111111111111111111 97 1111■■■■■E■■■■■■■■1111■ 8�]■ � 97 rr5s p, 96 $i 8901111111111111111113111 di 1111■■■■■M■■■■■■■■■■■■�■ � 95 96 ■MEMMEM■.1111.1■■MEMMEE,2 .B 94111111111111111111111141.0- 111111■■■■■1111■■■■■■E■■ME MEMMEM■EMEMEMMEEMMME■ ■■■■■E■■■■■■■■M■■U■■■ 8 ■■■■■■■■■■■■■■■■■■■■■■10 8 `. ,� 0 8_ ■■■■■■■U■■..M .•.■■° I 111111111111111511111184_ Hiii !!P! iF:i 8 .dP .2 !!1!!uo$' 1oU: o 20 25 30 0 35 0 � 1is $ 30 . - 47 9 +uE♦ew«, RATE OF FLOW y.1Ey,. RATE OF FLOW ©AII products purchased and services performed are subject to Sensus'terms of sale,available at either;http://na.sensus.com/TC/TermsConditions.pdf or 1-800-METER-IT.Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only,and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT.FURTHERMORE,THERE ARE NO IMPLIED WARRANTIES,INCLUDING WITHOUT LIMITATION,WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY.ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. 8601 Six Forks Road,Suite 700 Raleigh,NC 27615 Nom 1-800-638-3748 s E n s u s www.sensus.com/water DS-'fl-GP:1R-00-u0-0c=1 1 0 OMNITM R2 1-1/2- and 2. OMNI R Meter Description 1-1/2"and 2"Sizes The OMNI R2 meter operation is based on advanced Floating Ball Technology(FBT). = sEnsus _ UU.LJU 3Y-1 ! sEnsus CisEnsus\ PAMRnn004uu.x CAL Totalization Mode AMR/AMI Mode Resettable Test Mode Features CONFORMANCE TO STANDARDS approved NSF epoxy coating. Maincase STRAINER The OMNI R2metermeetsandfarexceeds features are; easily removable measuring The OMNI R2 with the"V"shaped integral the most recent revision of ANSI/AWWA chamber, unique chamber seal to the strainer using a stainless steel screen Standard C701 class II standards and maincase using a high pressure o-ring, testing port and a convenient integral along with Floating Ball Technology(FBT) exceeds ANSI/AWWA C700 Residential create a design that gives far improved Standard using Sensus Turbo technology. strainer. accuracy even in those once thought Each meter is performance tested to OMNI ELECTRONIC REGISTER questionable settings. A removable ensure compliance. All OMNI meters are strainer cover permits easy access to the NSF/ANSI Standard 61, Annex F and G The OMNI R2 electronic register consist screen for routine maintenance. approved. of a hermetically sealed register with an electronic pickup containing no MAINTENANCE PERFORMANCE mechanical gearing. The large character The OMNI R2 meter is designed for easy LCD displays AMR, Totalization and a The patented measurement principles Resettable Test Totalizer. OMNI register maintenance. Should any maintenance of the OMNI R2 meter assure enhanced features; AMR resolution units that are be required, the measuring chamber accuracy ranges, an overall greater fully programmable, Large, easy-to-read and/or strainer cover can be removed accuracy, and a longer service life LCD also displays both forward and independently.Parts and ora replacement than any other comparable class meter measuring chamber may be utilized in the produced. The OMNI R2 meter has no reverse flow directions and all with a 10- event repairs are needed. Replacement restrictions as to sustained flow rates year battery life guarantee. Measuring Chambers are available for within its continuous operating range.The MAGNETIC DRIVE the OMNI R2 meters and may be utilized floating ball measurement technology for retrofitting to competitive meters to allows for flows up to its rated maximum Meter registration is achieved by utilizing achieve increased accuracy and extended capacity without affecting undue wear or a fully magnetic pickup system. This is service life. accuracy degradation when installed in accomplished by the magnetic actions any orientation. of the embedded rotor magnets and the AMR/AMI SYSTEMS ultra sensitive register pickup probe. The Meters and encoders are compatible with CONSTRUCTION only moving component in water is the current Sensus AMR/AMI systems. "floating ball"impeller. The OMNI R2meter consists of two basic assemblies; the maincase and MEASURING ELEMENT GUARANTEE the measuring chamber. The measuring Sensus OMNI R2 Meters are backed chamber assembly includes the "floating The revolutionary thermoplastic, hydro by "The Sensus Guarantee." Ask your ball" impeller with a coated titanium dynamically balanced impeller floats Sensus representative for details or see shaft, hybrid axial bearings, integral between the bearings. The Floating Ball Bulletin G-500. flow straightener and an all electronic Technology (FBT) allows the measuring programmable register with protective element to operate virtually without friction bonnet. The maincase is made from or wear,thus creating the extended upper industry proven Ductile Iron with an and lower flow ranges capable on only the OMNI R2 meter. �. sEnsus DS-W-OMR-00-00-0611-03-A Page 2 of 3 OMNI R2: 1-1/2" and 2"Sizes D _.1 4 4 -A Pi Register with—! , 4... / r •re--7 Measuring ,': Chamber : : : ,I, Assembly 7 WStrainer Cover _ 4 T:4, . _ •,41-, ." eivrAmews-siiii 'litralialt 4.,;.1.---- —'' 111-L I ----- , '.-... . I „..-,...„:„....* B '' ...'". . ,,. ....,..:,._ 1. ,11.1w1---1 -11- ,,..., ,_,„_,,,...., ...,. .. ..1?...0\:,:. L."—lior j 0!-:,,,vi,,,,, Direction ,i4y,4. i.' .,grojle ) '.1'.i:t'''..‘•:','':.r:::::::-. :;' —€ . Of ROW —'.. 4:'PAZIi: ''-einglilk e ,• ',i'tY-•:t1I'i•;"1;" ...• NUM -- c:7-.-Pil I ':.4 •-, ... • •1 ••,-...,--Nacoae... `Ag.:4-' A'''''''''''' .. .• - *.—--''. •- E ,- ,. F-Bolt Circle ,r,..4)1'itY, I ..-"1 1 '-{G-No.of E3olts -• •04,..?;0,:k..v ,.,.. r H-Size of Bolts -Maincase R2 Rotor Strainer Screen D * . A. A -----, Register with— AMR I •r '' ''•--.. Measuring " A Chamber Assembly • ; 1 i.v:•;.".:., Fii). / .,.., — .......11,'77: ..-ri. .....111*'-- ,''.;-'• '4.•:'-- --:,,.. .. -/ -_, .---- ,: -r: B .."' ,.. , •, Direction t-- --(ft of Flow -1. T \ ' \,. . . . , ........ . , E . ---__---______, ...... {F BoltCircle ,.:. ----1 - GiNc.orBots .. -:-.777, .- -- •; - - m H-Size of Bolts Matt:ass R2 Rotor DIMENSIONS AND NET WEIGHTS Meter and Normal Connec- Net Shipping A B C D E F G H J Pipe Size Operating Range tions Weight Weight 1-1/2" 2 gpm 150 gpm 13" 7-7/8" 15/16' 5-1/8" 2-5/16" 5/8' 1" 18.8 lbs. 22.5 lbs. DN 40mm .45 ma/hr 34 me/hr Flanged 330mm 200mm 24mm 130mm 59mm 102mm 2 16mm 25mm 8.53 kg.. 10.20 kg. 2" 2.5 gpm 200 gpm 17" 7-7/8" 1" 5-3/4" 2-5/16" 4-1/2" 3/4" 1" 27.4 lbs. 34.5 lbs. DN 50mm .56 ma/hr 45 mFlangeda/hr 432mm 200mm 25mm 146mm 59mm 114mm 2 19mm 25mm 12.42 kg. 15,65 kg. 2"without 2.5 gpm 250 gpm 10" 7-7/8" 1" 5-3/4" 2-5/16" 4-1/2" 3/4" 1" 17 lbs. 24.5 lbs. Strainer DN 80mm .56 rrO/hr 57 m3/hr Flanged 254mm 200mm 25mm2 146mm 59mm 114mm 19mm 25mm 7.9 kg. 11.11 kg. MEM MOM MIMS sEnsus DS-W-OMR-00-00-0611-03-A -,:;.,,,E,,,,,;,,,,1:!,4„4,;,,-, Page 3 of 3 •I'','' k . OMNI R2: 1-1/2" and 2" Sizes SPECIFICATIONS SERVICE Measurement of potable and reclaim water. FLANGE U.S.ANSI 016.1/AWWA Class 125 Operating temperature range of 33°F(.56°C)-150°F(65.6°C) CONNECTIONS OPERATING 1-1/2": 2-150 GPM(.45-34 m3/hr) REGISTER Fully electronic sealed register with programmable registration RANGE 2": 2.5-200 GPM(.56-45 m'/hr) (Gal./Cu.Ft./Cu.Mtr./Imp.Gal/Acre Ft.) (100%±1.5%) 2"without Strainer: 2.5-200 GPM(.56-45 m3/hr) Programmable AMR/AMI reading output Guaranteed 10 year battery life LOW FLOW 1-1/2": .75 GPM(.17 m'/hr) NSF Maincase: Coated Ductile Iron (95%-101.5%) 2": 1.0 GPM(.23 m'/hr) APPROVED Measuring Chamber: Thermoplastic 2"without Strainer: 1.0 GPM(.23 m'/hr) MATERIALS Rotor"Floating Ball": Thermoplastic Radial Bearins: Hybrid Thermolastic PRESSURE 1-1/2": 6.7 psi @ 150 GPM(0.46 bar @ 34 m'/hr) Thrust Bearings: Sapphire/Ceramic Jewel LOSS 2": 7.0 psi @ 200 GPM(.48 bar @ 45 m'/hr) Magnets: Ceramic Magnet MAXIMUM Strainer Screen: Stainless Steel OPERATING 200 PSI(13.8 bar) Strainer Cover: Coated Ductile Iron PRESSURE Test Plug: Coated Ductile Iron Headloss Curves 1.5'"R2 Pressure Loss Curve with Strainer 1.5"R2 Accuracy Curve c 14 -go .,_, .,.. .. ,..,_ -. .. .. -,..1 1Et . . ;.-1-�... 901.5 u 1.110110.11111.1111111111111.11.111111C.1w 'li a I ■■ ■■1111x■■1111■■■11■■5. 1■■■1111■■■■ _ �( TIrT - -I ----- 90.5 0.15125 7 15 30 s0 so 100 1111 0.751.25 7 15 50 50 00 106 150 Rate of Flow(GPM) Rate of Flow(GPM) 2"R2 Pressure Loss Curve with Strainer 2"R2 Accuracy Curve ^ .. ... ._....... _ _ .. _..._.__ 10Z 0192 L ie0 ; - 1111", CL-0, 10 ._. 11■■■■1111111111111111 g c 1111■■■■■11■■■■ ���....; "_". ,+ ■■■■■■■I■■■11■ @ 1>a .. _ a OBS g 4 ■■■■■111111■■■11 �,, yg 97(.40.""+.7„.........0 - ....._-,..-._w ■■■■■11■■■■■■ �IIO■ 4 .. 2 111/1t111111.E..I.MMsetam"'' • 01.01.5 7 15 30 50 e0 100 11011 01.01.5 7 15 30 50 00 100 200 Rats of Flow(13PIA) Rate of Flow(GPU? 2"R2 Pressure Loss Curve without Strainer 10 ■■ ,_ 1111 , _. -I IIIz 1 1_ II +0 1.0 1.5 7 15 30 50 SO ra0 zoo Rate of!=low{GPM) ©All products purchased and services performed are subject to Sensus'terms of sale,available at either;http://na.sensus.com/TC/TermsConditions.pdf or 1-800-METER-IT.Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only,and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT.FURTHERMORE,THERE ARE NO IMPLIED WARRANTIES,INCLUDING WITHOUT LIMITATION,WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY.ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. 8601 Six Forks Road,Suite 700 Raleigh,NC 27615 swim 1-800-638-3748 SEriSLIS www.sensus.com/water DS-W-OMT-00-00-0611-03-A OMNITM T2 1-1/2", 2", 3", 4", 6", 8" and 10" OMNI T- Meter Description 1-1/2",2",3",4",6",8" and 10"Sizes The OMNI 12 meter operation is based on advanced Floating Ball Technology(FBT). C `" 5EnsUs nnn,iU V /sinsus sEnsus COOna{ nn UVn .0 GAL x:a= ° GAL Totalization Mode AMR/AMI Mode Resettable Test Mode Features CONFORMANCE TO STANDARDS sure o-ring, testing port and a convenient upper and lower flow ranges capable on The OMNI T2 meter meets and far ex integral strainer. only the OMNI T2 meter. ceeds the most recent revision of AW WA Standard C701 class II standards. Each OMNI ELECTRONIC REGISTER STRAINER meter is performance tested to ensure The OMNI T2 electronic register consist The OMNI T2 with the"V"shaped integral compliance. All OMNI meters are NSF/ of a hermetically sealed register with an strainer using a stainless steel screen ANSI Standard 61, Annex F and G ap- electronic pickup containing no mechani- along with Floating Ball Technology(FBT) proved. cal gearing.The large character LCD dis- create a design that gives far improved ac- plays AMR,Totalization and a Resettable curacy even in those once thought ques- PERFORMANCE Test Totalizer. OMNI register features; tionable settings. A removable strainer The patented measurement principles AMR resolution units that are fully pro- cover permits easy access to the screen grammable, Pulse output frequency that for routine maintenance. of the OMNI T2 meter assure enhanced are fully programmable, Integral customer accuracy ranges, an overall greater ac data logging capability, Integral resettable MAINTENANCE curacy, and a longer service life than any accuracy testing feature compatible with other comparable class meter produced. The OMNI T2 meter is designed for easy The OMNI T2 meter has no restrictions the UniPro Testing Assistant Program, maintenance. Should any maintenance as to sustained flow rates within its con- Large, easy-to-read LCD also displays be required, the measuring chamber tinuous operating range. The floating ball both forward and reverse flow directions and / or strainer cover can be removed measurement technology allows for flows and all with a 10 year battery life guaran independently.Parts and ora replacement up to its rated maximum capacity without tee. measuring chamber may be utilized in the affecting undue wear or accuracy degra- MAGNETIC DRIVE event repairs are needed. Replacement dation when installed in any orientation. Measuring Chambers Exchange are Meter registration is achieved by utilizing available for the OMNI 12 meters and CONSTRUCTION a fully magnetic pickup system. This is may also be utilized for retrofitting to The OMNI 12 meter consists of two basic accomplished by the magnetic actions of competitive meters to achieve increased assemblies; the maincase and the mea- the embedded rotor magnets and the ultra accuracy and extended service life. sensitive register pickup probe. The only surfing chamber.The measuring chamber moving component in water is the "float- AMR/AMI SYSTEMS: assembly includes the "floating ball" im- ing ball"impeller. peller with a coated titanium shaft, hybrid Meters and encoders are compatible with axial bearings, integral flow straightener MEASURING ELEMENT current Sensus AMR/AMI systems. and an all electronic programmable regis- ter with protective bonnet. The maincase The revolutionary thermoplastic, hydro GUARANTEE: is made from industry proven Ductile Iron dynamically balanced impeller floats be Sensus OMNI T2 Meters are backed with an approved NSF epoxy coating. tween the bearings. The Floating Ball Maincase features are; easily removable Technology (FBT) allows the measuring by "The Sensus Guarantee." Ask your measuring chamber, unique chamber element to operate virtually without fric Sensus representative for details or see seal to the maincase using a high pres- tion or wear, thus creating the extended Bulletin G-500. sEnsus D .. l ,1 lid-'',''2 1 - \ P 2 , 5 OMNI T2: 1-1/2", 2", 3", 4", 6", 8" and 10" Sizes OMNI T2: 1 1/2"-6" • D A Register with Pulse and AMRMeasuring ` • Chamber J -, C • Assembly Strainer Cover ' € • Test N,� 1-I. � �/�l� „�� / 'ii/..4( T.✓1, r Plug a °° .. 0000000000°°00o-�.»> 1= t\\���t�� ---- i00000000c °- B 000000000 Direction ,,,,, „c � �I y A of Flow - - � . c �i, ®L 7 - - p.............: 000Alft, 1 ^ E �zi'w;Vit;?�. \:'�����. ..�:�., »tio` F-Bolt Circle \\�� ;;, 2 G-No.of Bolts H-Size of Bolts Maincase T Rotor Strainer Screen OMNI T2: 8" -10" < D s Test Port(J) Register 7 7 -1 fD,- T • , r' - -Ch- _r _I _ 1 k. -II . r-.:--- 1131. o---( --- - -- Direction �I:d!1 B �'� 4P, of Flow '111,11.4 t,-,�rlr TF-Bolt Circle 1111II ___: G-No. of Bolts ?/. „/ H-Size of Bolts . Rotor I Maincase DIMENSIONS AND NET WEIGHTS Meter and Normal Net Shipping Connections A B C D E F G H J pP g Pipe Size Operating Range Weight Weight 1-1/2" 1.25 gpm 200 gpm 13" 7-7/8" 15/16" 5-1/8" 2-5/16" 4" 5/8" 1" 18.8 lbs. 22.5 lbs. DN 40mm .28 m'/hr 45 m'/hr Flanged 330mm 200mm 24mm 130mm 59mm 102mm 2 16mm 25mm 8.53 kg.. 10.20 kg. 2" 1.5 gpm 250 gpm 17" 7-7/8" 1" 5-3/4" 2-5/16" 4-1/2" 3/4" 1-1/2" 27.4 lbs. 34.5 lbs. DN 50mm .34 m'/hr 57 m'/hr Flanged 432mm 200mm 25mm 146mm 59mm 114mm 2 19mm 40mm 12.42 kg. 15.65 kg. 2"without Strainer 1.5 gpm 250 gpm Flanged 10" 7-7/8" 1" 5-3/4" 2-5/16" 4-1/2" 2 3/4" N/A 17.4 lbs. 24.5 lbs. DN 50mm .34 m'/hr 57 ma/hr 254mm 200mm 25mm 146mm 59mm 114mm 19mm 7.9 kg. 11.11 kg. 3" 2.5 gpm 650 gpm 19" 8-3/4" 3/4" 7-7/8" 4-1/8" 6" 5/8" 2" 48.5 lbs. 57.4 lbs. DN 80mm 57 '/hr 148 m'/hr Flanged 432mm 222mm 19mm 200mm 105mm 153mm 4 m16mm 50mm 22.00 kg. 26.04 kg. 4" 3.0 gpm 1250 gpm 23" 11-3/16" 15/16" 9-1/8" 4-3/4" 7-1/2" 5/8" 2" 67.9 lbs. 75.8 lbs. DN 100mm .68 m'/hr 284 m'/hr Flanged 584mm 284mm 24mm 232mm 121mm 191mm 8 16mm 50mm 30.80 kg. 34.38 kg. 6" 4 gpm 2500 gpm 27" 13-1/4" 15/16" 11" 5-3/4" 9-1/2" 3/4" 2" 140 lbs. 165 lbs. DN 150mm .91 m'/hr 568 m'/hr Flanged 685mm 336mm 24mm 279mm 146mm 242mm 8 19mm 50mm 52.3 kg. 61.6 kg. 8" 5 gpm 3500 gpm 30-1/8" 15" 11/16" 13-1/2" 6-3/4" 11-3/4" 3/4" 471 lbs. 521 lbs. DN 200mm 1.1 m'/hr 795 m'/hr Flanged 765 mm 381 mm 17 mm 343 mm 172 mm 300 mm 8 19 mm 2 NPT 214 kg. 236 kg. 10" 6 gpm 5500 gpm Flanged 41-1/8 19" 11/16" 16" 8-1/2" 14-1/4" 12 7/8" 2,,NPT 685 lbs. 745 lbs. DN 250mm 1.4 m'/hr 1249 m'/hr 485mm 17mm 406mm 216mm 362mm 22mm 311 kg. 338 kg. sEnsus DS-W-OMT-00-00-0611-03-A Page 3 of 5 OMNI T2: 1-1/2", 2", 3", 4", 6", 8" and 10" Sizes SPECIFICATIONS SERVICE Measurement of potable and reclaim water. Operating temperature range of 33°F(56°C)-150°F(65.6°C) OPERATING 1-1/2": 1.25-200 GPM(.28-45 m3/hr) RANGE 2"and 2"without Strainer: 1.5-250 GPM(.34-57 m3/hr) (100%±1.5%) 3": 2.5-650 GPM(.57-148 m3/hr) 4": 3-1250 GPM(.68-284 m3/hr) 6": 4-2500 GPM(.91-568 m3/hr) 8": 5-3500 GPM(1.1-795 m3thr) 10": 6-5500 GPM(1.4-1249 m3/hr) LOW FLOW 1-1/2": .75 GPM(.17 m3/hr) (95%-101.5%) 2"and 2"without Strainer: 1.0 GPM(.23 m3/hr) 3": 1.5 GPM(.34 m3/hr) 4": 2.0 GPM(.45 m3/hr) 6": 2.5 GPM(.57 m3/hr) 8": 4 GPM(0.9 m3/hr) 10": 5 GPM(1.1 m3/hr) MAXIMUM 1-1/2": 160 GPM(36 m3/hr) CONTINUOUS 2"and 2"without Strainer: 200 GPM(45 m3/hr) OPERATION 3": 500 GPM(114 m3/hr) 4": 1000 GPM(227 m3/hr) 6": 2000 GPM(454 m3/hr) 8": 3500 GPM(795 m3/hr) 10": 5500 GPM(1249 m3/hr) MAXIMUM 1-1/2": 200 GPM(45 m3/hr) INTERMITTENT 2"and 2"without Strainer: 250 GPM(57 m3/hr) OPERATION 3": 650 GPM(148 m3/hr) 4": 1250 GPM(284 m3/hr) 6": 2500 GPM(568 m3/hr) 8": 4700 GPM(1067 m3/hr) 10": 7000 GPM(1590 m3/hr) PRESSURE 1-1/2": 6.9 psi @ 160 GPM(48 bar @ 36 m3/hr) LOSS 2"and 2"without Strainer: 7.0 psi @ 200 GPM(.48 bar @ 45 m3/hr) 3": 5.1 psi @ 500 GPM(.35 bar @ 114 m3/hr) 4": 8.7 psi @ 1000 GPM(.60 bar @ 227 m3/hr) 6": 8.2 psi @ 2000 GPM(.56 bar @ 454 m3/hr) 8": 5.1 psi @ 3500 GPM(.35 bar @ 795 m3/hr) 10": 7.2 psi @ 5500 GPM(.50 bar @ 1249 m3/hr) MAXIMUM OPERATING 200 PSI(13.8 bar) PRESSURE FLANGE U.S.ANSI B16.1/AWWA Class 125 CONNECTIONS REGISTER Fully electronic sealed register with programmable registration (Gal./Cu.Ft./Cu.Mtr./Imp.Gal/Acre Ft.) Programmable AMR/AMI reading and pulse outputs Guaranteed 10 year battery life NSF Maincase: Coated Ductile Iron APPROVED Measuring Chamber: Thermoplastic MATERIALS Rotor"Floating Ball": Thermoplastic Radial Bearings: Hybrid Thermoplastic Thrust Bearings: Sapphire/Ceramic Jewel Magnets: Ceramic Magnet Strainer Screen: Stainless Steel Strainer Cover: Coated Ductile Iron Test Plug: Coated Ductile Iron atlEireal MINIM sEnsus c==,_\, _oc.IT-,-,{,-( )-(),-i 1 u --, F,Kr_ 4 of 5 OMNI T2: 1-1/2", 2", 3", 4", 6", 8" and 10" Sizes Headloss Curves 1.5"T2 Pressure Loss Curve with Strainer 1.5"T2 Accuracy Curve =:- 14 102 U) - 101.5 • ••••••..............„ 0 10 -,100 O >. 0 8 99 J , 98.5 2 6 A...............'.........:..../. : , '5 98 • • . . , , = 4 u 97 to O 2 96 A: 0 95 0.751.25 7 15 30 50 80 100 160 200 0.75 1.25 7 15 30 50 80 100 160 200 Rate of Flow(GPM) Rate of Flow(GPM) 2" T2 Pressure Loss Curve with Strainer 2" T2 Accuracy Curve ▪ 14 102 U) 101.5 a 12 ,,101 • - . ......."""""Y ...... O 10 e-100 - ...- .............. . >, 3 8 o 99 12 98.5 2 6 - 3 98 . O 4 8 97 - _ 0 g; 2 • 4 96 = a 0 95 0 1.01.5 7 15 30 50 80 100 200 250 0 1 01.5 7 15 30 50 80 100 200 250 Rate of Flow(GPM) Rate of Flow(GPM) 2" 12 Pressure Loss Curve without Strainer — 14 (I) 0_ 12 14,) to 2 6 - O 4 0 O 2 o PC 0 0 1.0 1.5 7 15 30 50 80 100 200 250 Rate of Flow(GPM) 3" 12 Pressure Loss Curve with Strainer 3" T2 Accuracy Curve _..--- 14 102 u) 101.5 0_ 12 . .101 ,.I.. >, o 99 98.5 2 6 g 98 0 T 2 < 96 = a_ 0 95 0 1.52.5 10 50 100 200 300 400 500 650 0 152.5 10 50 100 200 300 400 500 650 Rate of Flow(GPM) Rate of Flow(GPM) 4" T2 Pressure Loss Curve with Strainer 4"T2 Accuracy Curve .1.: 14 102 (.0 101.5 a 12 ..........47/./ .--101 ,- m 10 . .?--100 r Imm .............,.... 0 O 8 , u 99 J 98.5 E 6 g 98 = 4 8 97 w cl! 2 < 96 = a 0 95 0 10 50 100 200 300 600 1000 1250 02.03.0 10 50 100 200 300 600 1000 1250 Rate of Flow(GPM) Rate of Flow(GPM) .... www, sEnsus .`'-t) .1T_;,i 1):i_fL.11-0-',-t1 P:r,c5pi'5 OMNI T2: 1-1/2", 2", 3", 4", 6", 8" and 10" Sizes Headloss Curves -- 14 6" T2 Pressure Loss Curve with Strainer 6"T2 Accuracy Curve 102 d12 101 101.5 y 10 y 100fl �� O 8 . a, 6 SI 98 98.5 v 97 a�• 4 Q y 2 96 d 0 95 0 25 50 100 500 1000 1500 2000 2500 0 2.54.0 25 50 100 500 1000 1500 2000 2500 Rate of Flow(GPM) Rate of Flow(GPM) 8"T2 Pressure Loss Curve with Strainer 8"T2 Accuracy Curve U) 6zir101 • 101.5 w 5 100 ~e o 4 t.: - 3 98 98.5 3 j 2 u f.1 97 N w 1 < 96 a• 0 95 0 25 50 100 500 1000 2000 3500 0 4 5 25 50 100 500 1000 2000 3500 Rate of Flow(GPM) Rate of Flow(GPM) 10"T2 Pressure Loss Curve with Strainer 10"T2 Accuracy Curve 12 102 a_ 10 -.101 - • - 101.5 a 8 , 100 �� O 7 . _ u 99 JR - 98.5 w 5 . . . . 13 98 7 3 _ _ (,) 97 . a a 1 - < 96 - a` 0 - - 95 0 25 50 100 500 1000 2000 4500 5500 0 3 6 25 50 100 500 2500 3500 4500 5500 Rate of Flow(GPM) Rate of Flow(GPM) ©All products purchased and services performed are subject to Sensus'terms of sale,available at either;http://na.sensus.com/TC/TermsConditions.pdf or 1-800-METER-IT.Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only,and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT.FURTHERMORE,THERE ARE NO IMPLIED WARRANTIES,INCLUDING WITHOUT LIMITATION,WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY.ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. 8601 Six Forks Road,Suite 700 Raleigh,NC 27615 1-800-638-3748 SE Ii 5u S www.sensus.com/water DS-W-OMC-00-00-0611-03-A ®IIIIIII OMNITM C2 1-1/2-, 2', 3", 4", 6", 8" and 10" OMNI C- Meter Description 1-1/2", 2", 3",4", 6", 8"and 10" Sizes The OMNI C2 meter operation is • ,t - based on advanced Floating Ball >. Technology(FBT). 4 � � � � i_ sinsus /5Ef15U5` GAL x10 sEnsus i s nnnuT-1 nnu eu 0 GAL X rC.w^"., GAL Totalization Mode AMR/AMI Mode Resettable Test Mode Features CONFORMANCE TO STANDARDS maincase using a high pressure o-ring, STRAINER The OMNI 02 meter meets and far testing port and an AWWA compliant The OMNI 02 with the AWWA compliant exceeds the most recent revision of strainer. "V" shaped strainer using a stainless AWWA Standard 0701 and C702 class OMNI ELECTRONIC REGISTER steel screen along with Floating Ball II.Additionally,the meter does not require Technology (FBT) create a design that a valve to meet these standards. Each The OMNI 02 electronic register is gives far improved accuracy even in meter is performance tested to ensure hermetically sealed with an electronic those once thought questionable settings. compliance. All OMNI meters are NSF/ pickup containing no mechanical gearing. A removable strainer cover permits ANSI Standard 61, Annex F and G The large character LCD displays easy access to the screen for routine approved latest standards. AMR, Totalization and a Resettable maintenance. Test Totalizer. OMNI register features; PERFORMANCE AMR resolution units that are fully MAINTENANCE The patented measurement principles programmable, Pulse output frequency The OMNI 02 meter is designed for easy of the OMNI C2 meter assure enhanced that are fully programmable, Integral maintenance. Should any maintenance accuracy ranges, an overall greater customer data logging capability, Integral be required, the measuring chamber resettable accuracy testing feature accuracy, and a longer service life compatible with UniPro Testing Assistant and / or strainer cover can be removed than any other comparable class meter independently.Parts and or a replacement produced. The OMNI 02 meter has no Program, Large, easy-to-read LCD also measuring chamber may be utilized in the restrictions as to sustained flow rates displays both forward and reverse flow event repairs are needed. Replacement within its continuous operating range.The directions and all with a 10 year battery Measuring Chambers are available for floating ball measurement technology life guarantee. the OMNI 02 meters and may also be allows for flows up to its rated maximum MAGNETIC DRIVE utilized for retrofitting to competitive capacity without undue wear or accuracy meters to achieve increased accuracy degradation when installed in any Meter registration is achieved by utilizing and extended service life. orientation. a fully magnetic pickup system. This is accomplished by the magnetic actions AMR/AMI SYSTEMS: CONSTRUCTION of the embedded rotor magnets and the Meters and encoders are compatible with The OMNI 02 meter consists of two ultra sensitive register pickup probe. The current Sensus AMR/AMI systems. basic assemblies; the maincase and only moving component in water is the the measuring chamber. The measuring "floating ball"impeller. GUARANTEE: chamber assembly includes the "floating MEASURING ELEMENT Sensus OMNI 02 Meters are backed ball" impeller with a coated titanium by "The Sensus Guarantee." Ask your shaft, hybrid axial bearings, integral The revolutionary thermoplastic, hydro Sensus representative for details or see flow straightener and an all electronic dynamically balanced impeller floats Bulletin G-500. programmable register with protective between the bearings. The Floating Ball bonnet. The maincase is made from Technology (FBT) allows the measuring industry proven Ductile Iron with an element to operate virtually without fric- approved NSF epoxy coating. Maincase tion or wear, thus creating the extended features are; easily removable measuring upper and lower flow ranges capable on chamber, unique chamber seal to the only the OMNI 02 meter. sEnsus DS-W-OMC-00-00-0611-03-A Page 2 of 5 OMNI C2: 1-1/2", 2", 3", 4", 6", 8" and 10" Sizes OMNI C2: 1 1/2"-6" D y. A - Register with OM Pulse and AMR ' ,- r- — Measuring - �-C � 1 Chamber Assembly Strainer Cover -i J i anymn4'4 j �—,. .� r �......- „t,...„, T ........=.____:7___...... est ;.„.,, ..,,, .;„.„ 4...,Ala Plug 21.1 ._.____,... ,_,,,„., ‘,,, ,, ._,.........c--,11-. , _ K.MM(.1 ) })k8, B a0( MO Direction \ 1111;eK I V>h Diy of Flow >�' • 11 it E F-Bolt Circle ���a_s ������.�����a��. I\.I I. I G-No.ofBolts ���������u� H-Size of Bolts L Maincase LA ..- v C2 Rotor -Strainer Screen OMNI C2:8”-10" Test Port(J) 4 D y A - Register 17-1-- Direction ILIM111 B „ of Flow E • �� F-Bolt Circle {G-No.of Bolts I. �4 iy H-Size of Bolts //J Rotor FA _ Maincase DIMENSIONS AND NET WEIGHTS Meter and Normal Connections A B C D E F G H Net Shipping Pipe Size Operating Range Weight Weight 1-1/2" .5 gpm 200 gpm 13" 7-7/8" 15/16" 5-1/8" 2-5/16" 4" 5/8" 1" 18.8 lbs. 22.5 lbs. DN 40mm .11 m3/hr 45 m'/hr Flanged 330mm 200mm 24mm 130mm 59mm 102mm 2 16mm 25mm 8.53 kg.. 10.20 kg. 2" .5 gpm 200 gpm 15-1/4" 7-7/8" 1" 5-3/4" 2-5/16" 4-1/2" 3/4" 1" 25.4 lbs. 32.5 lbs. DN 50mm .11 m'/hr 45 m3/hr Flanged 387mm 200mm 25mm 146mm 59mm 114mm 2 19mm 25mm 11.39 kg. 14.74 kg. 3" 1 gpm 500 gpm 17" 8-3/4" 3/4" 7-7/8" 4-1/8" 6" 5/8" 1" 45 lbs. 72.8 lbs. DN 80mm .23 m3/hr 114 m3/hr Flanged 432mm 222mm 19mm 200mm 105mm 153mm 4 16mm 25mm 20.41 kg. 33.02 kg. 4" 1.5 gpm 1000 gpm 20" 11-3/16" 15/16" 9-1/8" 4-3/4" 7-1/2" 5/8" 1-1/2" 64.9 lbs. 72.8 lbs. DN 100mm .34 m3/hr 227 m'/hr Flanged 508mm 284mm 24mm 232mm 121mm 191mm 8 16mm 40mm 29.44 kg. 33.02 kg. 6" 3 gpm 2500 gpm 24" 13-1/4" 15/16" 11" 5-3/4" 9-1/2" 3/4" 1-1/2" 130 lbs. 155 lbs. DN 150mm .68 m3/hr 5687 m3/hr Flanged 610mm 336mm 24mm 279mm 146mm 242mm 8 19mm 40mm 48.5 kg. 57.8 kg. 8"DN 4 gpm.91 2700 gpm Flanged 30-1/8" 15" 11/16" 13-1/2" 6-3/4" 11-3/4" 8 3/4" 2"NPT 471 lbs. 521 lbs. 200mm m3/hr 614 m3/hr 765 mm 381 mm 17 mm 343 mm 172 mm 300 mm 19 mm 214 kg. 236 kg. 10" 5 gpm 4000 gpm Flanged 41-1/8 19" 11/16" 16" 8-1/2" 14-1/4" 12 7/8" 2"NPT 685 lbs. 745 lbs. ON 250mm 1.1 m3/hr 908 m3/hr 1045mm 485mm 17mm 406mm 216mm 362mm 22mm 311 kg. 338 kg. sEnsus DS-W-OMC-00-00-0611-03-A Page 3 of 5 OMNI C2: 1-1/2", 2", 3", 4", 6", 8" and 10" Sizes SPECIFICATIONS SERVICE Measurement of potable and reclaim water. Operating temperature range of 33°F(56°C)-150°F(65.6°C) OPERATING 1-1/2": .5-200 GPM(.11-45 m3/hr) RANGE 2": .5-200 GPM(.11-45 m3/hr) (100%±1.5%) 3": 1.0-500 GPM(.23-114 m3/hr) 4": 1.5-1000 GPM(.34-227 m3/hr) 6": 3-2000 GPM(.68-454 m3/hr) 8": 4-2700 GPM(0.91-614 m3'hr) 10": 5-4000 GPM(1.1-908 m3/hr) LOW FLOW 1-1/2": .25 GPM(.06 m3/hr) (95%-101.5%) 2": .25 GPM(.06 m3/hr) 3": .5 GPM(.11 m3/hr) 4": .75 GPM(.17 m3/hr) 6": 1.5 GPM(.34 m3/hr) 8": 2.5 GPM(0.57 m3/hr) 10": 3.5 GPM(0.8 m3/hr) MAXIMUM 1-1/2": 160 GPM(36m3/hr) CONTINUOUS 2": 160 GPM(36 m3/hr) OPERATION 3": 400 GPM(91 m3/hr) 4": 800 GPM(182 m3/hr) 6": 1600 GPM(363 m3/hr) 8": 2700 GPM(614 m3/hr) 10": 4000 GPM(908 m3/hr) MAXIMUM 1-1/2": 200 GPM(45 m3/hr) INTERMITTENT 2": 200 GPM(45 m3/hr) OPERATION 3": 500 GPM(114 m3/hr) 4": 1000 GPM(227 m3/hr) 6": 2000 GPM(454 m3/hr) 8": 3400 GPM(773 m3/hr) 10": 5000 GPM(1136 m3/hr) PRESSURE LOSS 1-1/2": 6.9 psi @ 160 GPM(48 bar @ 36 m3/hr) 2": 4.3 psi @ 160 GPM(.30 bar @ 36 m3/hr) 3": 3.2 psi @ 400 GPM(.22 bar @ 91 m3/hr) 4": 6.4 psi @ 800 GPM(.51 bar @ 182 m3/hr) 6": 5.5 psi @ 1600 GPM(.56 bar @ 363 m3/hr) 8": 4 psi @ 2700 GPM(.27 bar @ 614 m3/hr) 10": 4.5 psi @ 4000 GPM(.31 bar @ 908 m3/hr) MAXIMUM OPERATING 200 PSI(13.8 bar) PRESSURE FLANGE U.S.ANSI B16.1/AWWA Class 125 CONNECTIONS REGISTER Fully electronic sealed register with programmable registration (Gal./Cu.Ft./Cu.Mtr./Imp.Gal/Acre Ft.) Programmable AMR/AMI reading and pulse outputs Guaranteed 10 year battery life NSF Maincase: Coated Ductile Iron APPROVED Measuring Chamber: Thermoplastic MATERIALS Rotor"Floating Ball": Thermoplastic Radial Bearings: Hybrid Thermoplastic Thrust Bearings: Sapphire/Ceramic Jewel Magnets: Ceramic Magnet Strainer Screen: Stainless Steel Strainer Cover: Coated Ductile Iron Test Plug: Coated Ductile Iron sEnsus MINIM DS-„':--,J :C- , J.,-,?t ':-i; Page 4ot5 OMNI C2: 1-1/2", 2", 3", 4", and 6" Sizes Headloss Curves 1.5" C2 Pressure Loss Curve with Strainer 1.5"C2 Accuracy Curve 14 102 C12 tot 101.5 N 10 _ '100flT m99 9898.5 8j 97 96 a` 0 95 0.25 1 7 15 30 50 80 100 160 200 0 25 1 7 15 30 50 80 100 160 200 Rate of Flow(GPM) Rate of Flow(GPM) 2" C2 Pressure Loss Curve with Strainer 2” C2 Accuracy Curve --- 14 102 U)- ,- 12 . _ - - .101 1016 N 10 °100 '.........i. a 8 _ A 98 u 99 . _ - - _ 98.5 d- 6 . _ -" y 2 d 0_ 0- 95 0 1.0 1.5 7 15 30 50 80 100 200 0.25 1 7 15 30 50 80 100 160 200 Rate of Flow(GPM) Rate of Flow(GPM) 3" C2 Pressure Loss Curve with Strainer 102 3" C2 Accuracy Curve - 14 - 0. 12 _ 101 - - - - 101.5 y 10 . '-,7.100 -•*•.".'1 . . • r r. y 6 3 98 98.5 g 4 9° 97 d 2 Q 96 d 0 95 0 t52.5 10 50 100 200 300 400 500 0.5 1.0 10 50 100 200 300 400 500 Rate of Flow(GPM) Rate of Flow(GPM) 4" C2 Pressure Loss Curve with Strainer 4" CZ Accuracy Curve - 14 102 d^ 12 _ _ 101 101.1 a 10 - `✓...7.100 _ , 1 ► �� O 8 - . 0 99 _ . y- 6 . . _ 7 98 98.: g 4 O 97 W V IZd 2 < 96 Q. 0 95 0 10 50 100 200 300 600 1000 0 1 1.5 10 50 100 200 300 600 1000 Rate of Flow(GPM) Rate of Flow(GPM) 6"C2 Pressure Loss Curve with Strainer 6"C2 Accuracy Curve c 14 102 a_ 12 - ----101 tot: a 10 • •9 100 r r .,,",�," -I g 99 98.' E 6 3 98 7 4 oU 97 a 2 Q 96 a_ 0 95 0 25 50 100 500 1000 1500 2000 0 1.5 3.0 25 50 100 500 1000 1500 2000 Rate of Flow(GPM) Rate of Flow(GPM) sEnsus '�jsT ' &'.' ,. 4+ DS-W-OMC-00-00-0611-03-A , ; �° ::', Page 5 of 5 ;:' FIf.= OMNI C2: 8" and 10" Sizes Headloss Curves 8"C2 Pressure Loss Curve with Strainer 8"C2 Accuracy Curve N 7 102 — —1 — —— - 1.__-- ------ 10 a.. 6 , . -101 - o N 5 —100 N O 4 ' fl , , , , J y3 2 d1 96 d 0 95 0 25 50 100 500 1000 2000 3000 0 3 6 25 50 100 500 1000 2000 3000 Rate of Flow(GPM) Rate of Flow(GPM) 10"C2 Pressure Loss Curve with Strainer 10"C2 Accuracy Curve 7 102 L---- _.---------1----1--- 101.5 0. 6 101 • w 5 • °100 1 ....r...... w O 4 • U 99 m — 98.5 ED. 3 - 3 98 3 2 - U 97 w U w 1 _ Q 96 O 0- 0 95 0 25 50 100 500 1000 2000 3000 4000 0 3 6 25 50 100 500 1000 2000 3000 4000 Rate of Flow(GPM) Rate of Flow(GPM) ©All products purchased and services performed are subject to Sensus'terms of sale,available at either;http://na.sensus.com/TC/TermsConditions.pdf or 1-800-METER-IT.Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only,and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT.FURTHERMORE,THERE ARE NO IMPLIED WARRANTIES,INCLUDING WITHOUT LIMITATION,WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY.ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. 8601 Six Forks Road,Suite 700 Raleigh,NC 27615 > ' 1-800-638-3748 5 E n 5 u S ,• "" www.sensus.com/water MEM DS-W-OMN-H2-00-1013-01-A OMNITM H2 Fire Hydrant Meter Data Shed Description The OMNI H2 meter operation is based on advanced Floating — Ball Technology (FBT). The operating range is from 10 to ✓snsus` 550 gallons per minute (2.3 to = COO bq �{� 124.9 m3/h) with registration ri. " l l i' ■■ "GAL• "'k�++F yl,f' *�SERSIJ5 A GAL• 10 " En5u5\'s accuracy of 100% ± 1.5% of vron nnn n'nn actual throughput. uuO.�I GAL z r0.,.., ? •t GAI. Totalization Mode AMR/AMI Mode Resettable Test Mode Features CONFORMANCE TO STANDARDS seal to the maincase using a high pressure friction or wear, thus creating the The OMNI H2 meter is based on o-ring, and a convenient integral strainerextended upper and lower flow ranges advanced Floating Ball Technology. A variable orifice is positioned at the rear capable on only the OMNI H2 meter. Each meter is performance tested to of the maincase which limits the maximum ensure compliance. flow of water through the meter to protect STRAINER it from overspeeding which could occur The OMNI H2 with the"V"shaped integral PERFORMANCE when the outflow exits to atmosphere. strainer using a stainless steel screen The meter is intended for measuring OMNI ELECTRONIC REGISTER along with Floating Ball Technology(FBT) water from a fire hydrant or other 2 create a design that gives far improved non permanent installations. The meter The OMNI H electronic register consist accuracy. A removable strainer cover of a hermetically sealed register with an permits easy access to the screen for comes equipped with standard fire hose electronic pickupcontainingno mechani-swivel couplings and a register lid locking routine maintenance. cal gearing. The large character LCD bar as standard equipment. The patent displays AMR, Totalization and a MAINTENANCE ed measurement principles of the OMNI Resettable Test Totalizer. OMNI reg H2 meter assure enhanced accuracy The OMNI H2 meter is designed for easy ranges, an overall greater accuracy and a ister features include: AMR resolution maintenance. Should any maintenance longer service life than any other units that are fully programmable, inte be required, the measuring chamber comparable class meter produced. The gral customer data logging capability, and / or strainer cover can be removed OMNI H2 meter has no restrictions as to integral resettable accuracy testing fea independently. Parts and / ora replace- ture compatible with the UniPro Testing sustained flow rates within its continu- ment measuring chamber may be utilized Assistant Program, large easy-to-read ous operating range. The floating ball LCDthatdisplaysbothforwardand reverse in the event repairs are needed. Replace- measurement technology allows for ment Measuring Chambers are available flows up to its rated maximum capacity flow directions, and a 10-year battery life for the OMNI H2meters. without affecting undue wear or accuracy warranty. degradation when installed in any MAGNETIC DRIVE AMR/AMI SYSTEMS: orientation. Meters and encoders are compatible with Meter registration is achieved by utiliz- CONSTRUCTION ing a fully magnetic pickup system. This current Sensus AMR/AMI systems. The OMNI H2 meter consists of two basic is accomplished by the magnetic actions GUARANTEE: assemblies: the maincase and the mea- of the embedded rotor magnets and the surfing chamber. The measuring cham- ultra sensitive register pickup probe. The Sensus OMNI H2 Meters are backed ber assembly includes the "floating ball" only moving component in water is the by -The Sensus Guarantee." Ask your impeller with a coated titanium shaft, "floating ball"impeller. Sensus representative for details or see hybrid axial bearings, integral flow Bulletin G-500. straightener and an all electronic MEASURING ELEMENT programmable register with lockable The revolutionary thermoplastic, hydro bonnet. The maincase is made from dynamically balanced impeller floats cast aluminum with an enamel coating. between the bearings. The Floating Ball Maincase features include: easily remov- Technology (FBT) allows the measur- able measuring chamber,unique chamber ing element to operate virtually without MAIM E DS-W-OMN-H2-00-1013-01-A4d� Page 2 of 4 . `!' OMNI H2 Fire Hydrant Meter C F E A y- „,,,,.,i• k „ 6, ., r , .,, i' 1 (`y zi .,„,_ , =__.4. Uhl AIM-1EB �4- ^ - ■ � 11-11 I' r - r ,_d —__Iii41 2. � — 1 l i- _ Optional 2” Gate Valve 4.0011.111. 114-'-'..-.. Optional Support Bracket __ _ CY DIMENSIONS AND NET WEIGHTS Meter and Normal Net Shipping Connections A B C D E F pp g Pipe Size Operating Range Weight Weight 3"DN 10-550 gpm Couplings 16" 13" 7" 3.25" 19.5" 25.6" 22 lbs. 26 lbs. 80 mm 2.3-124.9 m'/hr 406.4 mm 330.2 mm 178 mm 82.6 mm 495 mm 650 mm 9.98 kg 11.79 kg sEnsus .111111111111111 DS-W-OMN-H2-00-1013-01-A -■ Page 3 of 4 SPECIFICATIONS SERVICE Measurement of potable and reclaim water. Operating temperature range of 33°F(56°C)-150°F(65.6°C) OPERATING RANGE 10-550 gpm(2.3-124.9 m'/hr) (100%±1.5%) MAXIMUM INTERMITTENT 650 gpm(147.6 m'/hr) OPERATION PRESSURE LOSS 90 psi at 400 gpm MAXIMUM OPERATING 150 psi(10.3 bar) PRESSURE HOSE 2-1/2"-7-1/2"NST Threads(78P-3.4 mm)(National Standard Fire Hose COUPLINGS Coupling thread)furnished unless otherwise specified.Complete thread specifications must be furnished for special fire hose fittings. REGISTER Fully electronic sealed register with programmable registration (Gal./Cu.Ft./Cu.Mtr./Imp.Gal/Acre Ft.) Programmable AMR/AMI reading 10 year battery life warranty MATERIALS Maincase: Cast Aluminum Measuring Chamber: Thermoplastic Rotor"Floating Ball": Thermoplastic Radial Bearings: Hybrid Thermoplastic Thrust Bearings: Sapphire/Ceramic Jewel Magnets: Ceramic Magnet Strainer Screen: Stainless Steel Strainer Cover: Cast Aluminum OPTIONS Available with: •2"Gate valve on outlet end •Techno-check reverse flow check valve •Adjustable support rod assembly •Blank cover for maincase FLOW Limits flow through meter to 400 gpm at 60 psi(90 m3h at 4 bar) RESTRICTIONS SPECIFICATIONS FOR SPECIAL FIRE HOSE COUPLING THREADS See page 2 of H2 configurator. TECHNO-CHECK VALVE The Techno-Check Valve is a reverse flow check valve for the OMNI H2 fire hydrant meter. This is an optional feature that should be identified as a requirement at the time the order is placed. Techno-check Valves must be installed at the factory. sEnsus DS-W-OMN-H2-00-1013-01-A Page 4 of 4 OMNI H2 Headloss Curves H2 Pressure Loss Curve 10 9 Cl) 8 0 6 J 5 a' 4 V) 3 " 2 o_ 1 0 c 0 5 10 25 50 100 150 200 250 300 350 x10 Rate of Flow (GPM) H2 Accuracy Curve 102 101.5 101 100 99 • - 98.5 98 o 97 U < 96 95 94 0 10 25 50 100 150 200 250 300 350 Rate of Flow (GPM) WARRANTY ©All products purchased and services performed are subject to Sensus'terms of sale, available at either; http://na.sensus.com/ TC/TermsConditions.pdf or 1-800-637-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT. FURTHERMORE,THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION,WARRANTIES AS TO FIT- NESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFI- CALLY PERMITTED HEREIN IS PROHIBITED. 8601 Six Forks Road,Suite 700 Raleigh,NC 27615 44101.111 1-800-637-3748 5 E n S u S www.sensus.com/water OMNITM F2 4 . 6.. 8. and 10 OMNI F Meter Description 4",6",8"and 10"Sizes The OMNI F2 meter operation is �: > • based on advanced Floating Ball _ /si`nsus'� Technology(FBT). , ,� ;• ,,,�nL3�y 006.0 : O GAL G • :g 'SEnSUS • ; — Guu.vuu.0 Totalization Mode AMR/AMI Mode Resettable Test Mode Features CONFORMANCE TO STANDARDS seal to the maincase using a high pres- STRAINER The OMNI F2 meter meets and far exceeds sure o ring, testing port and a convenient The OMNI F2 meter includes the Sensus the most recent revision of AWWA integral strainer with optional drain/debris designed "V" shaped UL Listed/FM ap- flushingStandard C703 class II. Additional) ports. Additionally, proved strainer which utilizes a stainless the meter does not require a valve to steel screen along with Floating Ball Tech- OMNImeet these standards. Each meter is ELECTRONIC REGISTER, nology(FBT)to create a design that gives performance tested to ensure compliance. The OMNI F2 electronic register is her- far improved accuracy even in those once All OMNI meters are NSF/ANSI Standard metically sealed with electronic pickup thought questionable settings. A remov- 61, Annex F and G approved. The OMNI containing no mechanical gearing. The able strainer cover permits easy access F2 meter is UL(Underwriters Laboratories) large character LCD displays AMR, To- to the screen for routine maintenance. Listed and FM(Factory Mutual)approved talization and a Resettable Test Totalizer. Optional drain ports, located at the back for use on fire protection and domestic OMNI register features; AMR resolution lower corners of the strainer body, allow water applications. units that are fully programmable, Pulse for easy discharging of debris without the output frequency that are fully program- need to remove the cover. PERFORMANCE mable, Integral customer data logging The patented measurement principles of capability, Integral resettable accuracy MAINTENANCE the OMNI F2 meter assure enhanced ac- testing feature compatible with the UniPro The OMNI F2 meter is designed for easy curacy ranges, an overall greater accura- Testing Assistant Program, Large, easy maintenance. Should any maintenance cy,and a longer service life than any other to read LCD also displays both forward be required,the measuring chamber and/ and reverse flow directions and all with a comparable class meter produced.The F2 or strainer cover can be removed inde- meter has no restrictions as to sustained 10 year battery life guarantee. pendently. Parts and or a replacement flow rates within its continuous operat- measuring chamber may be utilized in the ing range. The floating ball measurement MAGNETIC DRIVE event repairs are needed. Replacement technology allows for flows up to its rated Meter registration is achieved by utilizing Measuring Chambers are available for the maximum capacity without undue wear or a fully magnetic pickup system. This is OMNI F2 meters. accuracy degradation. accomplished by the magnetic actions of the embedded rotor magnets and the ultra AMR/AMI SYSTEMS CONSTRUCTION sensitive register pickup probe. The only Meters and encoders are compatible with The OMNI F2 meter consists of two basic moving component in water is the "float- current Sensus AMR/AMI systems. assemblies; the maincase and the mea- ing ball"impeller. suring chamber. The measuring chamber MEASURING ELEMENT GUARANTEE assembly includes the "floating ball" im- Sensus OMNI F2 Meters are backed peller with a coated titanium shaft, hybrid The revolutionary thermoplastic, hydro by "The Sensus Guarantee." Ask your axial bearings, integral flow straightener dynamically balanced impeller floats be Sensus representative for details or see and an all electronic programmable regis- tween the bearings. The Floating Ball Bulletin G-500. ter with protective bonnet. The maincase Technology (FBT) allows the measuring is made from industry proven Ductile Iron element to operate virtually without fric- with an approved NSF epoxy coating. tion or wear, thus creating the extended Maincase features are; easily removable upper and lower flow ranges capable on measuring chamber, unique chamber only the OMNI F2 meter. sEnsus DS-W-OMF-00-00-0611-02-A Page 2 of 3 OMNI F2: 4", 6", 8" and 10" < D , Measuring Chamber Register with Assembly Pulse and AMR —' r C F Strainer Cover d -.- Test Test _ Q\�c—��N.�\� Plug t 1�^tl� .. �m ,, §1; m- Direction i b0000 0000°. . ._ � ,V •oo• .0000 ,1/ + Iof Flow I i„ . i i -MO 1 0op®®001 opoo• ? 0%•r"--1�i', m 0000r 1 i0000 /i a , 0 / . \ •.' F-Bolt Circle G-No.of Bolts Maincase Strainer H-Size of Bolts Strainer Screen F Rotor DIMENSIONS AND NET WEIGHTS Meter and Normal Net Shipping Standard Connections A B C D E F G H J pp 9 Pipe Size Operating Range Weight Weight Fireline 4” 1.5 gpm 1000 gpm 33" 13-11/16" 15/16" 17-1/2" 4-3/4" 7-1/2" 5/8" 2" 212 lbs. 252 lbs. 51-7/8" DN 100mm .34 m'/hr 227 m'/hr Flanged 838mm 348mm 24mm 446mm 121mm 191mm 8 16mm 50mm 96 kg. 115 kg. (1317mm) 6" 3.0 gpm 2000 gpm 45" 15-3/4" 15/16" 22-3/8" 5-3/4" 9-1/2" 3/4" 2" 394 lbs. 449 lbs. 67-5/8" DN 150mm .681 m'/hr 454 m'/hr Flanged 1143mm 400mm 24mm 569mm 146mm 242mm 8 19mm 50mm 179 kg. 204 kg. (1717mm) 8" 4 gpm 3500 gpm 53" 18-1/2" 11/16" 31" 6-3/4" 11-3/4" 3/4" 2" 736 lbs. 786 lbs. 77" DN 200mm .91 m3/hr 795 m'/hr Flanged 1346mm 470mm 17mm 787mm 172mm 298mm 8 19mm NPT 334 kg. 357 kg. (1956mm) 10" 5 gpm 5500 gpm 68" 22-1/4" 11/16" 37-1/3" 8-1/2" 14-1/4" 7/8 2" 1155 lbs. 1215 lbs. 90" DN 250mm 1.1 m3/hr 1249 m'/hr Flanged 1727mm 565mm 17mm 947mm 216mm 362mm 12 22mm NPT 524 kg. 551 kg. (2286mm) 'Standard Fireline lay length with optional spool piece added. SPECIFICATIONS SERVICE Measurement of potable and reclaim water. PRESSURE 4": 6.4 psi @ 1000 GPM(.60 bar @ 227 m'/hr) Operating temperature range of 33°F(56°C)-150°F(65 6°C) LOSS 6": 6.7 psi @ 2000 GPM(.56 bar @ 454 m'/hr) 8": 5 psi @ 3500 GPM(.34 bar @ 795 m'/hr) OPERATING 4": 1.5-1000 GPM(34-227 m'/hr) 10" 7 psi @ 5500 GPM(48 bar @ 1249 m'/hr) RANGE 6": 3.0-2000 GPM(.34-227 m3/hr) (100%±1.5%) 8": 4-3500 GPM(0.91-795 m'/hr) MAXIMUM 10": 5-5500 GPM(1.1-1249 m'/hr) OPERATING 175 PSI(12 bar) PRESSURE LOW FLOW 4": .75 GPM(.06 m3/hr) (95%-101.5%) 6": 1.5 GPM(.06 m'/hr) FLANGE U.S.ANSI 816.1/AW WA Class 125 8": 2.5 GPM(0.57 m3/hr) CONNECTIONS 10": 3.5 GPM(0.8 m'/hr) REGISTER Fully electronic sealed register with programmable registration UL MINIMUM 8": 97%@ 3 GPM(0.68 m3/hr) (Gal./Cu.Ft./Cu.Mtr./Imp.Gal/Acre Ft.) FLOW 10": 97%@ 4 GPM(0.9 m3/hr) Programmable AMR/AMI reading and pulse outputs Guaranteed 10 year battery life MAXIMUM 4": 1000 GPM(227 m3/hr) CONTINUOUS 6": 2000 GPM(454 m'/hr) NSF Maincase: Coated Ductile Iron OPERATION 8": 3500 GPM(795 m'/hr) APPROVED Measuring Chamber: Thermoplastic 10"' 5500 GPM(1249 m'/hr) MATERIALS Rotor"Floating Ball": Thermoplastic Radial Bearings: Hybrid Thermoplastic MAXIMUM 4": 1250 GPM(284 m3/hr) Thrust Bearings: Sapphire/Ceramic Jewel INTERMITTENT 6": 2500 GPM(568 m'/hr) Magnets: Ceramic Magnet OPERATION 8": 4700 GPM(1067 m3/hr) Strainer Screen: Stainless Steel 10": 7000 GPM(1590 m3/hr) Strainer Cover: Coated Ductile Iron Test Plug: Coated Ductile Iron sEnsus • DS-W-O M F-00-00-0611-02-A Page 3 of 3 • OMNI F2: 4", 6", 8" and 10" Head loss Curves 4" F2 Pressure Loss Curve with Strainer 4" F2 Accuracy Curve - 14 102 0. 12 ---.101 - 101.5 N 10 - 100 • an O 8 - • U 99 J 2 98.5 ` 6 0 98 - = 4 cvi 97 - - - da2 , Q 96 • ` 0 95 0 10 50 100 200 300 600 1000 0 .5 1.5 10 50 100 200 300 600 1000 Rate of Flow(GPM) Rate of Flow(GPM) 6°F2 Pressure Loss Curve with Strainer 6°F2 Accuracy Curve 14 102 0. 12 .--101 101.5 w 10 6 100 . , im J 8 c.) 99 y 6 A 98 . . 98.5 0 w 4 o 97 a i 2 Q 96 d 0 95 0 25 50 100 500 1000 1500 2000 0 1 3.0 25 50 100 500 1000 1500 2000 Rate of Flow(GPM) Rate of Flow(GPM) 8"F2 Pressure Loss Curve with Strainer 8"F2 Accuracy Curve - 10 102 a101.5--101 101.5 a, 6 , . , e 100 Wm...." O 4 c.) 99 J R 98.5 ED. 3 .Z• . 98 a 2 0L) 97 m 1 Q 96 a 0 95 0 25 50 100 500 1000 2000 3500 0 3 6 25 50 100 500 1000 2000 3500 Rate of Flow(GPM) Rate of Flow(GPM) 10°F2 Pressure Loss Curve with Strainer 10"F2 Accuracy Curve - 12 102 Cl) 10 101 101.5 N 8 F 100 �� O 6 99 5 R 98 98.5 N 3 v 97 ami 1 Q 96 a 0 95 • 0 25 50 100 500 1000 2500 4500 5500 0 3 6 25 50 100 500 1000 2500 4500 5500 Rate of Flow(GPM) Rate of Flow(GPM) ©All products purchased and services performed are subject to Sensus'terms of sale,available at either;http://na.sensus.com/TC/TermsConditions.pdf or 1-800-METER-IT.Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. This document is for informational purposes only,and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT.FURTHERMORE,THERE ARE NO IMPLIED WARRANTIES,INCLUDING WITHOUT LIMITATION,WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY.ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. 8601 Six Forks Road,Suite 700 Immo Raleigh,NC 27615 1-800-638-3748 5 E n 5 u 5 www.sensus.com/water Sensus Limited Warranty G-500820 I.General Product Coverage XI.Sensus Registers... Sensus USA Inc.("Sensus")warrants its products and parts to be free from defects in are warranted to be free from defects in material and workmanship from the date of Sensus material and workmanship for one(1)year from the date of Sensus shipment and as set shipment for the periods stated below or until the applicable registration for AVWVA forth below. All products are sold to customer("Customer)pursuant to Sensus'Terms Repaired Meter Accuracy Standards,as set forth above,are surpassed,whichever occurs of Sale,available at:sensus.com/TC("Terms of Sale"). first: II.SR II®and accuSTREAM""5/8",3/4"&1"Meters... 5/8°thru 2"SR,SR II,PMM,accuSTREAM Standard Registers 25 years are warranted to perform to AWWA New Meter Accuracy Standards for five(5)years 5/8"thru 2'SR,SR II,PMM,accuSTREAM Encoder Registers 10 years from the date of Sensus shipment or until the registration shown below, whichever Electronic Communication Index(ECI) 10 years occurs first.Sensus further warrants that the SR II meter will perform to at least AWWA Repaired Meter Accuracy Standards for fifteen (15) years from the date of Sensus All HSPU,IMP Contactor,R.E.R.Elec.ROFI 1 year shipment or until the registration shown below,whichever occurs first: Standard and Encoder Registers for:"W Turbo and Propeller Meters 1 year New Meter Accuracy Repair Meter Accuracy OMNI Register with Battery 10 years 5/8"SR II Meter and 500,000 gallons 1,500,000 gallons XII.Sensus Electric Meters... accuSTREAM Meter 3/4"SR II Meter and are warranted to be free from defects in material and workmanship for one(1)year from accuSTREAM Meter 750,000 gallons 2,250,000 gallons the date of Sensus shipment. Spare parts and components are warranted to be free from defects in material and workmanship for one(1)year from the date of Sensus shipment. 1"SR II Meter and 1,000,000 gallons 3,000,000 gallons accuSTREAM Meter Repaired or refurbished equipment repaired by Sensus is warranted to be free from defects in material and workmanship for ninety(90)days from the date of Sensus shipment or for III.SR®5/8",3/4"&1"Meters... the time remaining on the original warranty period,whichever is longer. are warranted to perform to AWWA New Meter Accuracy Standards for one(1)year XIII.Batteries,iPERL System Components,AMR and FlexNet""System AMI Interface from the date of Sensus shipment.Sensus further warrants that the 5/8",3/4"and 1"SR Devices... meter will perform to at least AW WA Repaired Meter Accuracy Standards for fifteen(15) years from the date of Sensus shipment or until the registration shown below,whichever are warranted to be free from defects in material and workmanship from the date of Sensus occurs first: shipment for the period stated below: Repair Meter Accuracy Electronic TouchPad 10 years 5/8"SR Meter 1,500,000 gallons RadioReade MXU(Model 505C,51 OR or 520R)and Batteries 20 years' 3/4"SR Meter 2,250,000 gallons Act-Pak®Instrumentation 1 year 1"SR Meter 3,000,000 gallons TouchReade Coupler and AMR Equipment 1 year IV.SR 1-1/2"&2"... FlexNet Water or Gas SmartPoint""Modules and Batteries 20 years' are warranted to perform to AWWA New Meter Accuracy Standards for one(1)year Hand Held Device 1 year from the date of Sensus shipment.Sensus further warrants that the 1-1/2"and 2"SR Vehicle Gateway Base Station 1 year meter will perform to at least AWWA Repaired Meter Accuracy Standards for ten(10) FlexNet Base Station(including the Metro and M400 base stations) 1 year years from the date of Sensus shipment or until the registration shown below,whichever Echo Transceiver 1 year occurs first: Remote Transceiver 1 year Repair Meter Accuracy iConA and FlexNet Electricity SmartPoint Module 1 year 1-1/2°SR 5,000,000 gallons iPERL System Battery and iPERL System Components 20 years` 2"SR 8,000,000 gallons Residential Electronic Register 20 years' V.PMM®5/8",3/4",1"Meters... *Sensus will repair or replace non-performing: are warranted to perform to AWWA New Meter Accuracy Standards for one(1)year from the date of Sensus shipment.Sensus further warrants that the 5/8",3/4",and 1" •RadioRead®MXU(Model 505C,510R and 520R)and Batteries, PMM meter will perform to at least AWWA Repaired Meter Accuracy Standards for •FlexNet Water or Gas SmartPoint Modules (configured to the factory setting of six fifteen(15) years from the date of Sensus shipment or until the registration shown transmissions per day under normal system operation of up to one demand read to each below,whichever occurs first: SmartPoint Module per month and up to two firmware downloads during the life of the Repair Meter Accuracy product)and batteries, 5/8"PMM 1,500,000 gallons •Residential Electronic Register with hourly reads,and 3/4°PMM 2,000,000 gallons •iPERL System Batteries,and/or the iPERL System flowtube,the flow sensing and data 1"PMM 3,000,000 gallons processing assemblies, and the register ("iPERL System Components") with hourly reads VI.PMM 1-1/2",2"Meters... at no cost for the first ten (10) years from the date of Sensus shipment, and for the are warranted to perform to AWWA New Meter Accuracy Standards for one(1)year remaining ten(10) years, at a prorated percentage, applied towards the published list from the date of Sensus shipment.Sensus further warrants that the 1-1/2",and 2"PMM prices in effect for the year product is accepted by Sensus under warranty conditions meter will perform to at least AWWA Repaired Meter Accuracy Standards for ten(10) according to the following schedule: years from the date of Sensus shipment or until the registration shown below,whichever Years Replacement Price Years Replacement Price occurs first: 1—10 0% 16 55% Repair Meter Accuracy 11 30% 17 60% 1-1/2"PMM 5,000,000 gallons 12 35% 18 65% 2"PMM 8,000,000 gallons 13 40% 19 70% VII.iPERLT"Water Management Systems... 14 45% 20 75% that register water flow are warranted to perform to the accuracy levels set forth in the 15 50% >20 100% iPERL Water Management System Data Sheet available at sensus.com/iperl/datasheet Note:Software supplied and licensed by Sensus is warranted according to the terms of the or by request from 1-800-METER-IT, for twenty(20)years from the date of Sensus applicable software license agreement. Sensus warrants that network and monitoring shipment. The iPERL System warranty does not include the external housing. services shall be performed in a professional and workmanlike manner. VIII.Maincase... XIV.Return... of the SR,SR II and PMM in both standard and low lead alloy meters are warranted to Sensus'obligation,and Customer's exclusive remedy,under this Sensus Limited Warranty be free from defects in material and workmanship for twenty-five(25)years from the is,at Sensus'option,to either(i)repair or replace the product,provided the Customer(a) date of Sensus shipment.Composite and E-coated maincases will be free from defects returns the product to the location designated by Sensus within the warranty period;and(b) in material and workmanship for fifteen(15)years from the date of Sensus shipment. prepays the freight costs both to and from such location; or (ii) deliver replacement components to the Customer,provided the Customer installs,at its cost,such components IX.Sensus"W"Series Turbo Meters,OMNI"Meters and Propeller Meters... in or on the product(as instructed by Sensus), provided, that if Sensus requests, the are warranted to perform to AWWA New Meter Accuracy Standards for one(1)year Customer(a)returns the product to the location designated by Sensus within the warranty from the date of Sensus shipment. period;and(b)prepays the freight costs both to and from such location. In all cases, if Customer does not return the product within the time period designated by Sensus,Sensus X.Sensus accuMAG' Meters... will invoice,and Customer will pay within thirty days of the invoice date,for the cost of the are warranted to be free from defects in material and workmanship,under normal use replacement product and/or components. and service,for 18 months from the date of Sensus shipment or 12 months from startup, The return of products for warranty claims must follow Sensus' Returned Materials whichever occurs first. Authorization(RMA)procedures.Water meter returns must include documentation of the 8601 Six Forks Road,Suite 700 _ Raleigh,NC 27615 SEiiSIJ5 1-800-638-3748 Customer's test results.Test results must be obtained according to AWWA standards and must specify the meter serial number. The test results will not be valid if the meter is found to contain foreign materials. If Customer chooses not to test a Sensus water meter prior to returning it to Sensus,Sensus will repair or replace the meter,at Sensus' option, after the meter has been tested by Sensus. The Customer will be charged Sensus' then current testing fee. Sensus SmartPoints modules and MXU's returned must be affixed with a completed return evaluation label. For all returns, Sensus reserves the right to request meter reading records by serial number to validate warranty claims. For products that have become discontinued or obsolete("Obsolete Product"),Sensus may, at its discretion, replace such Obsolete Product with a different product model ("New Product"),provided that the New Product has substantially similar features as the Obsolete Product. The New Product shall be warranted as set forth in this Sensus Limited Warranty. THIS SECTION XIV SETS FORTH CUSTOMER'S SOLE REMEDY FOR THE FAILURE OF THE PRODUCTS, SERVICES OR LICENSED SOFTWARE TO CONFORM TO THEIR RESPECTIVE WARRANTIES. XV.Warranty Exceptions and No Implied Warranties... This Sensus Limited Warranty does not include costs for removal or installation of products,or costs for replacement labor or materials,which are the responsibility of the Customer. The warranties in this Sensus Limited Warranty do not apply to goods that have been: installed improperly or in non-recommended installations; installed to a socket that is not functional,or is not in safe operating condition,or is damaged,or is in need of repair; tampered with;modified or repaired with parts or assemblies not certified in writing by Sensus,including without limitation,communication parts and assemblies; improperly modified or repaired (including as a result of modifications required by Sensus);converted;altered;damaged;read by equipment not approved by Sensus;for water meters,used with substances other than water,used with non-potable water,or used with water that contains dirt, debris, deposits, or other impurities; subjected to misuse, improper storage,improper care,improper maintenance,or improper periodic testing (collectively, "Exceptions."). If Sensus identifies any Exceptions during examination,troubleshooting or performing any type of support on behalf of Customer, then Customer shall pay for and/or reimburse Sensus for all expenses incurred by Sensus in examining, troubleshooting, performing support activities, repairing or replacing any Equipment that satisfies any of the Exceptions defined above. The above warranties do not apply in the event of Force Majeure,as defined in the Terms of Sale. THE WARRANTIES SET FORTH IN THIS SENSUS LIMITED WARRANTY ARE THE ONLY WARRANTIES GIVEN WITH RESPECT TO THE GOODS, SOFTWARE LICENSES AND SERVICES SOLD OR OTHERWISE PROVIDED BY SENSUS. SENSUS EXPRESSLY DISCLAIMS ANY AND ALL OTHER REPRESENTATIONS, WARRANTIES, CONDITIONS, EXPRESSED, IMPLIED, STATUTORY OR OTHERWISE, REGARDING ANY MATTER IN CONNECTION WITH THIS SENSUS LIMITED WARRANTY OR WITH THE TERMS OF SALE, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY,NON-INFRINGEMENT AND TITLE. SENSUS ASSUMES NO LIABILITY FOR COSTS OR EXPENSES ASSOCIATED WITH LOST REVENUE OR WITH THE REMOVAL OR INSTALLATION OF EQUIPMENT. THE FOREGOING REMEDIES ARE CUSTOMER'S SOLE AND EXCLUSIVE REMEDIES FOR THE FAILURE OF EQUIPMENT, LICENSED SOFTWARE OR SERVICES TO CONFORM TO THEIR RESPECTIVE WARRANTIES. XVI.Limitation of Liability... SENSUS'AGGREGATE LIABILITY IN ANY AND ALL CAUSES OF ACTION ARISING UNDER, OUT OF OR IN RELATION TO THIS AGREEMENT, ITS NEGOTIATION, PERFORMANCE, BREACH OR TERMINATION (COLLECTIVELY "CAUSES OF ACTION") SHALL NOT EXCEED THE TOTAL AMOUNT PAID BY CUSTOMER TO SENSUS UNDER THIS AGREEMENT. THIS IS SO WHETHER THE CAUSES OF ACTION ARE IN TORT, INCLUDING, WITHOUT LIMITATION, NEGLIGENCE OR STRICT LIABILITY,IN CONTRACT,UNDER STATUTE OR OTHERWISE. AS A SEPARATE AND INDEPENDENT LIMITATION ON LIABILITY, SENSUS' LIABILITY SHALL BE LIMITED TO DIRECT DAMAGES. SENSUS SHALL NOT BE LIABLE FOR: (I) ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES; NOR(II)ANY REVENUE OR PROFITS LOST BY CUSTOMER OR ITS AFFILIATES FROM ANY END USER(S),IRRESPECTIVE OF WHETHER SUCH LOST REVENUE OR PROFITS IS CATEGORIZED AS DIRECT DAMAGES OR OTHERWISE; NOR (III) ANY IN/OUT COSTS; NOR (IV) MANUAL METER READ COSTS AND EXPENSES;NOR(V)DAMAGES ARISING FROM MAINCASE OR BOTTOM PLATE BREAKAGE CAUSED BY FREEZING TERMPERATURES, WATER HAMMER CONDITIONS,OR EXCESSIVE WATER PRESSURE. "IN/OUT COSTS°MEANS ANY COSTS AND EXPENSES INCURRED BY CUSTOMER IN TRANSPORTING GOODS BETWEEN ITS WAREHOUSE AND ITS END USER'S PREMISES AND ANY COSTS AND EXPENSES INCURRED BY CUSTOMER IN INSTALLING,UNINSTALLING AND REMOVING GOODS. "END USER" MEANS ANY END USER OF ELECTRICITY/WATER/GAS THAT PAYS CUSTOMER FOR THE CONSUMPTION OF ELECTRICITY/WATER/GAS,AS APPLICABLE. The limitations on liability set forth in this Agreement are fundamental inducements to Sensus entering into this Agreement. They apply unconditionally and in all respects. They are to be interpreted broadly so as to give Sensus the maximum protection permitted under law. To the maximum extent permitted by law, no Cause of Action may be instituted by Customer against Sensus more than TWELVE(12)MONTHS after the Cause of Action first arose. In the calculation of any damages in any Cause of Action, no damages incurred more than TWELVE(12)MONTHS prior to the filing of the Cause of Action shall be recoverable. 8601 Six Forks Road,Suite 700 Raleigh,NC 27615 s E n s■u.s 1-800-638-3748 Andrea Davis 8601 Six Forks Road T:919-424-8995 �. Director, Raleigh,NC 27615 F:919-424-8976 S E n5 U 5 Channel Marketing andrea.davis@sensus.com wvw.sensus.com November 10, 2016 RE: Texas Distributors To Whom It May Concern: Sensus, USA is pleased to announce that Aqua Metric is the exclusive Authorized Distributor of Sensus products for Port Arthur, TX . Please contact Aqua Metric for all of your Sensus needs. Purchasing Sensus, USA products from the authorized distributor for your area ensures that your products will be properly supported and warranted. We look forward to the opportunity of providing your firm with quality water measurement equipment and support in the near future. Please feel free to contact me at andrea.davisCa�sensus.com regarding this or any other matter. Sincerely Andrea Davis Sensus, USA Director, Channel Marketing