HomeMy WebLinkAboutPR 22422 AUTHORIZING AN AGREEMENT WITH INDUSTRIAL AND COMMERIAL MECHANICAL TO REPLACE TWO HVAC UNITS THE DEPARTMENT CLUB Memorandum City of Port Arthur, Texas Robert A. "Bob"Bowers Civic Center To: The Honorable Mayor and City Council Through: Ron Burton,City Manager From: Adam J Saunders,Civic Center Dir RE: Proposed Resolution No. P.R. 22422 REQUEST: The Department Club needs two new HVAC units. It has been determined that two of the current units that cool and heat the building have failed and need replacement. Industrial and Commercial Mechanical (ICM) of Beaumont, Texas can do this work for $25,629.33 out of Civic Center Building Maintenance Account Number 001-15-043-5312-00-20-000. ANALYSIS/CONSIDERATION: Two of the current HVAC units at the Department Club need replacement. ICM of Beaumont,Texas has provided a price for this work under the Buyboard cooperative contract # 638-21 in the amount of $25,629.33 out of account number 001-15-043-5312-00-20-000. RECOMMENDATION A resolution authorizing the City Manager to enter into an agreement with Industrial and Commercial Mechanical of Beaumont,Texas to replace two HVAC units at the Department Club in the amount of $25,629.33. Funds available in account number 001-15-043-5312-00-20-000. BUDGETARY AND FISCAL EFFECT Funds available in Civic Center Building Maintenance account number 001-15-043-5312-00-20-000. STAFFING EFFECT None PO 22422 P.R. No. 22422 03/03/2022 AJS PAGE 1 of 3 RESOLUTION NO. A RESOLUTION AUTHORIZING THE CITY MANAGER TO ENTER INTO AN AGREEMENT WITH INDUSTRIAL AND COMMERCIAL MECHANICAL OF BEAUMONT, TEXAS THROUGH BUYBOARD COOPERATIVE PURCHASING PROGRAM CONTRACT NO. 638-21 TO REPLACE TWO HVAC UNITS AT THE DEPARTMENT CLUB IN THE AMOUNT OF $25,629.33. FUNDS AVAILABLE IN ACCOUNT NUMBER 001-15-043-5312-00-20-000. WHEREAS, the Department Club needs two new HVAC units to replace the current, failed units for the cooling and heating of the building; and WHEREAS, Industrial and Commercial Mechanical of Beaumont, Texas can do this work for $25,629.33; and WHEREAS, Industrial and Commercial Mechanical of Beaumont, Texas has a cooperative contract with Buyboard; and, WHEREAS, Chapter 271 of the Local Government Code allows a city, by resolution of its governing body, to participate in cooperative purchasing programs, such as Buyboard, a purchasing cooperative, as an alternative to a formal bid process; and WHEREAS, per Resolution No. 02-341, the City entered into an interlocal agreement for cooperative purchasing with the Buyboard Cooperative Purchasing Program("Buyboard"). NOW THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PORT ARTHUR: Section 1. That the facts and opinions in the preamble are true and correct. Section 2. That, the City Manager is hereby authorized to enter into an agreement with Industrial and Commercial Mechanical of Beaumont, Texas through Buyboard Cooperative Purchasing PO 22422 Program Contract No. 638-21 to replace two HVAC units at the Department Club in the amount of $25,629.33, in substantially the same form as attached hereto as Exhibit"A". Section 3. That, a copy of the caption of this Resolution be spread upon the Minutes of the City Council. READ, ADOPTED, AND APPROVED, this day of March 2022, A.D., at a Regular Meeting of the City Council of the City of Port Arthur, Texas by the following vote: AYES: Mayor: Councilmembers: NOES: Thurman"Bill"Bartie, Mayor ATTEST: Sherri Bellard, City Secretary APPROVED AS TO FORM: Valecia Ti eno, City Attorney APPROVED FOR ADMINISTRATION: Ronald Burton, City Manager PO 22422 APPROVED AS TO FUND AVAILABILITY: Kandy Daniel, r Clifton Williams, CPPB Interim Director of Finance Purchasing Manager • PO 22422 EXHIBIT A • CITY OF PORT ARTHUR-DEPARTMENT CLUB AT 1924 LAKESHORE DR. PORT ARTHUR-ICM PROPOSAL TO FURNISH AND INSTALL 2-CARRIER FANCOIL UNITS HEATPUMP COND UNITS AND LINESETS Industrial and Commercial r00000111110111111111111111, Mechanical TACIA23943C 4445 Westpark Avenue Beaumont,TX 77705 Phone(409)842-3737 Fax (409)842-3738 February 21,2022 CITY OF PORT ARTHUR TEXAS 444 4TH STREET 1 PORT ARTHUR,TX 1 77640 ATTN: Adam Saunders-CITY OF PORT ARTHUR-DEPARTMENT CLUB-1924 LAKESHORE DRIVE. Subject: CITY OF PORT ARTHUR-DEPARTMENT CLUB-ICM PROPOSAL TO FURNISH AND INSTALL A QTY OF 2-5 TON INDOOR FAN/COIL UNITS WITH 10KW ELECTRIC HEAT AND COPPER LINE-SETS Includes OPTION for Installing a qty of 2 New 5 Ton Carrier Heat Pump Condensing units Mr.Saunders, Please note that PROPOSAL IS BASED ON utilizing the attached-scope of work-Provided to ICM: • Replace existing units number 1 and 3 to connect back to existing condensing units • Replace existing unit#1 with 5 ton Ruud 14 seer straight cool with connecting sub electric heating 12Kw 230V and connect to conductors/disconnect noted on construction document. • Replace existing unit#3 with 5 ton Ruud 14 seer straight cool with connecting sub electric heating 2Kw 230V and connect to conductors/disconnect noted on construction document. Industrial Commercial Mechanical is pleased to offer the following proposal TO FURNISH AND INSTALL 2-5 TON INDOOR FAN COIL UNITS WITH NEW REFRIGERANT LINE-SETS AND 10 KW ELECTRIC HEATERS INCLUDES AS LISTED BELOW; Item QTY Description 1. 2 CARRIER FX4DNF061L00 14 SEER S TON FAN/COIL UNITS,INSTALLED VERTICAL IN EXISTING CLOSET AREAS. 2. 2 PROPOSAL INCLUDES QTY OF 2-7/8"X SOFT AND 3/8"X 50FT COPPER REFRIGERANT LINESETS WHICH WILL BE FURNISHED AND INSTALLED FROM FAN COIL UNITS OUT TO AREA WHERE EXISTING CONDENSING UNITS(PROVIDED BY CUSTOMER)WILL BE FURNISHED AND RECONNECTED BY OWNERS EXISTING JOB AC REPRESENTATIVE. 3. 2 PROPOSAL INCLUDES QTY OF 2-CARRIER 10KW 240VAC 1PH.ELECTRIC STRIP HEATERS,INSTALLED IN EACH 5 TON INDOOR FAN/COIL UNITS.(See note attached for supplying larger Heat Strip Units) 4. 2 FIBER-BOARD DUCT SUPPLY PLENUMS-ATTACHED 1-ON TOP OF EACH NEW AIR HANDLER UNIT. 5. 1 LOT 1"WALL INSULTUBE-TUBING INSULATION,INSTALLED ON EACH SYSTEM LINE-SET 6. 2 MEN HVAC TECHNICIANS LABOR-TO INSTALL AIR HANDLERS IN EXISTING VERTICAL CLOSET AREA,WITH OWNER'S CARPENTRY REPRESENTATIVE PROVIDING ANY MODIFICATIONS OR WOODWORK,THAT MAY BE NEEDED,INCLUDES ANY PLATFORM MATERIALS OR SUPPORT PLATFORM MODIFICATIONS. 7 2 INCLUDES QTY OF 2-CARRIER MODEL 25HCE460AP03 14 SEER HEAT PUMP CONDENSING UNITS INCLUDES MATERIALS AND LABOR TO FURNISH AND INSTALL 1 HEAT PUMP OUTDOOR UNIT,TO EACH OF THE NEW 5 TON INDOOR FAN/COIL UNITS AND NEW REFRIGERANT LINE-SETS.THIS WORK INCLUDES PROVIDING INSTALL AND START UP WITH NEW R410A REFRIGERANT FOR EACH NEW HEAT PUMP SYSTEM. 8 2 OPTION INSTALLING HEAT PUMP OUTDOOR UNITS-ALSO INCLUDES FURNISH AND INSTALLING 2 NEW NON-PROGRAMMABLE DIGITAL TP-N-721 THERMOSTATS TO CONTROL HEAT PUMP SYSTEMS TACLA 23943C-Regulated by the Texas Department of Licensing and Regulation PO Box 12157 Austin,TX 78711 1-800-803-9202,512-463-6599 CITY OF PORT ARTHUR-DEPARTMENT CLUB AT 1924 LAKESHORE DR. PORT ARTHUR-ICM PROPOSAL TO FURNISH AND INSTALL 2-CARRIER FANCOIL UNITS HEATPUMP COND UNITS AND LINESETS Page 2- Proposal continued ITEMS NOT INCLUDED IN PROPOSAL > Any Changes or Modifications,other than specified as part of proposal,or proposed scope of work. > Any Changes or Work delays;due to problems beyond our control. > Warranty of any items not furnished and installed by ICM > Any Electrical work or electrical wiring to equipment is furnished by owner's Electrical representative This includes replacement of any wiring which may not be large enough to support new equipment. > Any Plumbing work for AC condensate drain piping,is furnished by owner's Plumbing representative. > Supply and Return Air Ductwork is being installed by existing AC Contractor,working for the owner's General Contracting construction company and is NOT INCLUDED in the work provided by ICM. > Any woodworking materials or modifications cutting,or framing are provided by Owner's Carpentry representative. Outdoor units AC support slabs and/or steel ANTI-THEFT cage equipment,is not included in proposed work. Scope of Work—CLARIFICATIONS: ICM is asked to furnish materials and labor to install a quantity of 2—5-ton, indoor Fan/Coil units with Electric heating in the existing vertical closet platform locations at the Department Club. The original indoor Fan coil units and outdoor condensing units and refrigerant line-sets have previously been removed by General contractors existing AC representative. ICM will furnish and install 2-new indoor 5—Ton Fan/Coil units, with new Copper line-sets extended outside-to be connected to a quantity of 2—NEW Carrier 5-Ton 14 SEER Heat Pump Condensing units Any extended supply and/or return air Ductwork including grills associated with these AC systems are being furnished and installed by the owners General Contracting AC Company working on this Job. !CM will be providing labor or materials for the Startup,of these New Heat Pump AC units PRICE TO PERFORM THE PROPOSED WORK-INCLUDING 2 NEW HEATPUMP OUTDOOR UNITS Labor $ 9860.00 Materials $ 15,769.33 Total $ 25,629.33 Sales Tax is Not Included ADDENDUM -to Furnish Larger-15 to 20 KW Heat Strip Kits,for both Indoor Fan Coil units ADD$400.00 to Total Price Proposed listed above. ***This will require Electrical Modifications for the size Electrical Wiring that will supply these Heating Strip Kits. THIS PROPOSAL IS VALID FOR 30 DAYS-FROM THE DATE OF PROPOSAL INDUSTRIAL&COMMERCIAL MECHANICAL IS AN AWARDED VENDOR FOR BUYBOARD CONTRACT#638-21. BUY BOARD PRICING IS UTILIZED WITH THIS PRESENTED PROPOSAL FOR REPAIRS. Thank you for your request for this proposal. We would appreciate the opportunity to provide these services.Please let me know if you would like to proceed with the proposed service repair,and what purchase order number we will utilize,for our billing for services. As always,we thank you for your business and the opportunity to provide our services. Regards, Jerry F. Johnson TACLA 23943C-Regulated by the 7 etas Department of Licensing and Regulation PO Box 12157 Austin,TX 78711 1-800-803-9202,512-463-6599