PR 24242: PURCHASE OF 150KW GENERATOR WITH PLATFORM AND SECURITY FENCING FOR THE OPERATIONS CENTER
Cir,'of tart rthtt � www.PortArthurTx.E; INTEROFFICE MEMORANDUM Date: March 6, 2025 To: The Honorable Mayor and City Council Through: Ronald Burton, CPM, City Manager From: Flozelle Roberts, EIT,MEng,MBA, CPM, Director of Public Works RE: P.R. 24242 —Purchase of one (1) 150kW Generator with Platform and Security Fencing for the Operations Center from Energy Systems of Houston, Texas, through the Sourcewell Cooperative Purchasing Program Introduction: This agenda item requests the Council's approval to purchase one (1) 150kW generator with platform and security fencing for the Operations Center. Background: The Operations Center houses the Public Works Streets, Drainage, and Solid Waste Divisions and the Parks and Recreation Department's Facilities Maintenance Division. The consistent operation of the Operations Center is vital; therefore, a generator is required during power outages. The Operations Center's renovation project included a bid alternative to move an existing 200kW diesel generator at City Hall and install the equipment with a platform and security fencing at the Operations Center for$251,871.00.The bid alternative was accepted and approved in the construction contract. Energy Systems of Houston, Texas, provided a quote under the Sourcewell Cooperative Purchasing Program to install a 150kW generator with a platform and security fencing for$116,395.00, a cost savings of$135,476.00. "Remember,we are here to serve the Citizens of Port Arthur" 444 4a'Street X Port Arthur,Texas 77641-1089 X 409.983.8182 X FAX 409.983.8294 Staff recommends the purchase and installation of the generator by Energy Systems of Houston, Texas.A deductive change order to move the City Hall generator will be presented to the Council for approval via PR 24213. Budget Impact: Energy Systems of Houston, Texas, which maintains contract number 092222-GNR with the Sourcewell Cooperative Purchasing Program,provided a competitive quote for the installation of a 150kW generator with a platform and security fencing for$116,395.00. The purchase will be funded through the Public Works Administration Buildings Capital Improvement Fund Account, 307-21-049-8512-00-10-000,Project Number BU0001-CON. Recommendation: Staff recommends the approval of PR 24242 authorizing the City Manager to purchase one(1) 150kW generator with platform and security fencing for the Operations Center from Energy Systems of Houston,Texas,through the Sourcewell Cooperative Purchasing Program. • "Remember,we are here to serve the Citizens of Port Arthur" P.O.Box 1089 X Port Arthur,Texas 77641-1089 X 409.983.8101 X FAX 409.982.6743 PR 24242 03/06/2025 FCR Page 1 of 4 RESOLUTION NO. A RESOLUTION AUTHORIZING THE CITY MANAGER TO PURCHASE ONE (1) 150kW GENERATOR WITH PLATFORM AND SECURITY FENCING FOR THE OPERATIONS CENTER FROM ENERGY SYSTEMS OF HOUSTON, TEXAS, THROUGH THE SOURCEWELL COOPERATIVE PURCHASING PROGRAM WITH A BUDGETARY IMPACT OF $116,395.00. FUNDS ARE AVAILABLE IN THE PUBLIC WORKS ADMINISTRATION BUILDINGS CAPITAL IMPROVEMENT FUND ACCOUNT NUMBER 307-21-049- 8512-00-10-000, BU0001-CON. WHEREAS, the Operations Center houses the Public Works Department's Streets, Drainage, and Solid Waste Divisions and the Parks and Recreation Department's Facilities Maintenance Division,which require continuous power to maintain operations and service to the City of Port Arthur; and, WHEREAS,the Operations Center's renovation project included a bid alternative to move an existing 200kW diesel generator at City Hall and install the equipment with a platform and security fencing at the Operations Center for $251,871.00. The bid alternative was accepted and approved in the construction contract; and, WHEREAS, Energy Systems of Houston, Texas, provided a quote under the Sourcewell Cooperative Purchasing Program to install a 150kW generator with a platform and security fencing for$116,395.00, a cost savings of$135,476.00; and, WHEREAS, staff recommends purchasing and installing the generator from Energy Systems of Houston, Texas. A deductive change order to move the City Hall generator will be presented to the Council for approval at a later date; and, WHEREAS, Chapter 271 of the Texas Government Code allows a city, by resolution of its governing body, to participate in cooperative purchasing programs such as the Sourcewell PR 24242 03/06/2025 FCR Page 2 of 4 Cooperative Purchasing Program as an alternative to a formal bid process; and, WHEREAS,pursuant to Resolution No. 13-556,the City of Port Arthur entered into an interlocal agreement for cooperative purchasing with the Sourcewell Cooperative Purchasing Program(formerly National Joint Powers Alliance); and, WHEREAS,Energy Systems of Houston, Texas, is part of the Sourcewell Cooperative Purchasing Program under contract number 092222-GNR and submitted a competitive quote for one(1) 150kW generator for$116,395.00 attached hereto as Exhibit A; BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PORT ARTHUR, TEXAS: THAT,the facts and opinions in the preamble are true and correct; and, THAT,the City Manager of the City of Port Arthur is hereby authorized to purchase one (1) 150kW generator from Energy Systems of Houston, Texas, for$116,395.00; and, THAT, funding for this purchase is available in the Public Works Administration Buildings Capital Improvement Fund Account, 307-21-049-8512-00-10-000, Project Number BU0001-CON; and, THAT, a copy of the caption of this Resolution be spread upon the Minutes of the City Council. READ,ADOPTED,AND APPROVED this the day of ,A.D. 2025, at a meeting of the City of Port Arthur, Texas,by the following vote: Ayes: Mayor: Councilmembers: PR 24242 03/06/2025 FCR Page 3 of 4 Noes: Thurman Bill Bartie Mayor Attest: Sherri Bellard, TRMC City Secretary APPROVED AS TO FORM: Roxann Pais Cotroneo, Esq. City Attorney APPROVED FOR ADMINISTRATION: Oil t -,.. 4rimpoPP Ronald Burton, CP IV." City Manager _,, A ozel - r. Robip T, MEng, MBA, CPM Dire• or .f Pubrks PR 24242 03/06/2025 FCR Page 4 of 4 APPROVED AS TO AVAILABILITY OF FUNDS: Lyn a Boswell,ICMA-CM, MA Director of Finance 1' v LAtite,-1 Clifton 7. Williams, Jr., CPPB Purchasing Manager EXHIBIT A (SOURCEWELL CONTRACT QUOTE) 9 , GENERAC* Sourcewell .x * INDUSTRIAL Awarded Contract Contract#092222 GNR Date: February 24,2025/RV3 City of Port Arthur Public Works Department Brad Brown Drainage Superintendent Brad.brown@portarthurtx.gov-409-549-0738 Reference: OPERATIONS CENTER SG150 w/36"with custom raised frame&fence Project details&narrative: • Partnership to execute a turnkey solution with A&A for(1) 150kw nat gas&(1)400 ATS • A&A is responsible for system sizing and equipment selection based on site walkthrough • Project will follow Sourcewell guidelines under contract#092222-GNR for equipment • Customer Sourcewell Member ID#61648 • Generac Gencoonect#20958210/dp • Turnkey package price only, prices listed below are not intended for individual sale Quantity 1 -Generac Industrial nat Gas 9.0L • 150 kW Rating,wired for 120/208 three phase, 60 Hz • Permanent Magnet Excitation • UL2200/EPA Certified -SCAQMD Certified • Standard Weather Protective Enclosure, Steel • Digital Control • Primary MLCB,80%rated thermal-magnetic,400 Amp • Battery Charger, 10 Amp, NFPA 110 compliant, installed • 110 AH,925 CCA Group 31 Battery,with rack, installed • Block heater STD 1500W • 120V GFCI and 240V Outlet • Std set of 3 Manuals • Standard 2-Year Limited Warranty • Freight to site -offloading by A&A • Basic Start up (after installation is complete) 1 of 4 Quantity 1 -TX Series Automatic Transfer Switch • 400 Amp,3pole, 120/208 VAC three phase,60 Hz,with 2-Wire Start Circuit • 3 Owner's Manuals • Controller and Circuit Breaker Covers, Padlockable, Black • NEMA 3R Enclosure w/Enclosure Heater • Service Entrance Rated • In Phase Only Transfer • Standard two year basic warranty Quantity 1 — Istallation&Services (Item#2 below) • Freight to Site&std start up by EST(after install is complete and nat gas is plumbed) • Customer Training(during the scheduled startup) • Warranty registration • Std steel rigid conduit&copper wire and underground materials will be PVC • Demolition of existing canopy and removal of MTS • Special 36"Riser Skid that matches the genset footprint(bolted to genset in the field) • Fence-installation of 7ft tall(plus 16in barbed wire top,overall height 8.5ft)15'x20' Commercial Grade galvanized chain link fence with barbed twist with 3 row barbed wire top and(1)4ft access walk gate • Concrete-2 ft above finish grade 8'x14'slab dimension • Product offloading,setting and assembly of special risr to genset • Installation Servcies byA&A—Josh Marceaux • Concrete house keeping pad/slab • Requried project trenching • Labor/manpower • Installation materials(pipe,wire and misc) • Permits • Misc. Materials required for install and commision of above described equipemnt. EST provided (1)150kW Industrial Generac generator and (1) 400amp transfer switch. Installation Exclusions:Aluminum Conduit,Generator,ATS,gas meter upgrades and any unforeseen problem with existing circuitry. Sourcewell Awarded Contract i Contract#097197-GNR Sourcewell Proiect Pricing: Item #1 Generac Equipment SG15050 & 400AATS $ 48,995.00 Item #2 Site Services &A&A Installation $67,400.00 Project total investment for the above equipment $116,395.00 (Not including any applicable tax) 2 of 4 Notes Estimated Delivery:Generator—after approved submittals and written release for production. Prices valid for 30 days from above date Terms/Start Up/Delivery: Generac Dealer Startup included (for Generator)—Inspection for warranty and building load transfer test during normal business hours(8AM—5PM).This includes one roundtrip within 150 miles of the Generac dealer's facility during normal business hours;additional mileage and/or testing can be quoted separately.Additional trips required due to incomplete site preparation will be invoiced to the customer at the dealer's prevailing service rate. Clarifications and Exceptions: 1. Offloading and placement of the generator is not included and is the responsibility of the purchaser. 2. EST suppliers and installation vendors will be paid when paid from the City 3. Diesel to be provided by City of Port Arthur) 4. Any unforeseen problems with existing site or electrical circuitry that affect the completion, change is scope of supply and/or projects cost will be invoiced to the End User 5. A&A takes responsibility for sizing the system and turnkey solution.Any errors or emissions in the scope of supply or materials will be the responsibility of A&A 6. This proposal is based on specification of drawings. 7. Generator installation services are not included and are the responsibility of the purchaser. This includes all related mechanical piping(exhaust or fuel systems),electrical conduit and electrical wiring. 8. Generator preventative maintenance services are not included and are the responsibility of the purchaser. 9. NETA acceptance testing, harmonic content testing, insulation resistance testing, infrared scanning and/or ground fault testing are not included in this proposal.Standard factory testing and standard on-site testing at unity power factor are included. 10. Coordination study,3rd party site testing, protective relay calibration,settings,etc.are not included in this proposal. 11. Fuel is not included in this proposal unless specifically listed above. Diesel fuel is required for startup and testing of generator and will be the responsibility of the purchaser. 12. All permitting, including Air Quality Management District(AQMD or APCD),will be the responsibility of the purchaser. 3 of 4 13. Installation of exhaust silencer(if removed for shipping)shall be the responsibility of the installing contractor. 14. Breaker and automatic transfer switch lugs are provided per the factory offerings and submittal information per UL2200 and UL1008 approvals. Projects that require lug changes will be done by others at their expense. 15. Proposal does not include federal, state,or local sates, use,property,TERP,or excise taxes. In lieu of such taxes,the purchaser must provide the seller a tax exemption certificate acceptable to the proper taxing authorities prior to the order being processed 16. Lead times listed in this proposal are an estimate of current factory production schedules and should be verified at time of order release. Lead time: 10-13 Weeks+Installation time Terms and Conditions Net 30 days,subject to review and approval by our Credit Dept. Payment obligations are not dependent or contingent upon the manner in which purchaser may receive payment from others. No retainage against this order will be permitted unless agreed to ahead of time.Warranty is invalid without factory start up. Start up will be done during normal business hours.Additional charges will be applied to start ups requested on weekends or off normal business hours. Sincerely, Chris Johnson Regional Sales Manager—Industrial Sales (713)-416-9500 C_h.ris.johnson@enetgysystems,cPn1. Acceptance of Quote Prior to ordering equipment or services, please sign and return as a confirmation of the above terms and conditions. Customer Signature 4 of 4 SG150 I 9.0 L I 150 kW GENERAC® I INDUSTRIAL INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency Standby Power Rating 150 kW, 188 kVA, 60 Hz • ri it ,.t-Iritte -. 4-1 , ‘ 'As. b.Cin MelWwin9 . tgna¢Ik aM ro.9n parts Image used for illustration purposes only Codes and Standards Powering Ahead Generac products are designed to the following Generac provides superior quality by designing and manufacturing standards:. most of its generator components,such as alternators, enclosures, control systems and communications software. Generac also TI� makes its own spark-ignited engines, and you'll find them on every EIV u VL UL2200, UL508, UL489 Generac gaseous-fueled generator.We engineer and manufacture them from the block up—all at our facilities throughout Wiscon- sin.Applying natural gas and LP-fueled engines to generators re- CSA C22.2 quires advanced engineering expertise for reliability, durability and necessary performance. By designing specifically for these dry, D I N` 9• BS5514 and DIN 6271 hotter-burning fuels,the engines last longer and require less main- tenance. Building our own engines also means we control every step of the supply chain and delivery process, so you benefit from A SAE J1349 single-source responsibility. Plus, Generac Industrial Power's distribution network provides all ILIJO NFPA 37, 70, 99, 110 parts and service so you don't have to deal with third-party suppli- NFPA ers. It all leads to a positive owner experience and higher confi- NEC700, 701, 702,708 dence level. Generac spark-ignited engines give you more options in commercial and industrial generator applications as well as ex- NEMA ICS10, MG1, 250,ICS6, tended run time from utility-supplied natural gas. R' AB1 / ANSI C62.41 r.r irrsw.rrir W N i;=�. IBC 2009,CBC 2010, IBC 2012, ass* a Em=a ASCE 7-05,ASCE 7-10, ICC-ES osbpd AC-156(2012) 1 o1 6 SG150 I 9.0 L I 150 kW GENERAL® INDUSTRIAL INDUSTRIAL SPARK-IGNITED GENERATOR SET AeMIIIII EPA Certified Stationary Emergency STANDARD FEATURES ENGINE SYSTEM ELECTRICAL SYSTEM GENERATOR SET • Oil Drain Extension • Battery Charging Alternator • Internal Genset Vibration Isolation • Air Cleaner • Battery Cables • Separation of Circuits-High/Low Voltage • Fan Guard • Battery Tray • Separation of Circuits-Multiple Breakers • Stainless Steel Flexible Exhaust Connection • Rubber-Booted Engine Electrical Connections • Wrapped Exhaust Piping • Factory Filled Oil and Coolant • Solenoid Activated Starter Motor • Standard Factory Testing • Radiator Duct Adapter(Open Set Only) • 2 Year Limited Warranty(Standby Rated Units) • Critical Silencer/Catalyst ALTERNATOR SYSTEM • Silencer Mounted in the Discharge Hood • UL2200 GENprotect— (Enclosed Only) FUEL SYSTEM • Class H Insulation Material • NPT Fuel Connection on Frame • 2/3 Pitch ENCLOSURE(If Selected) • Primary and Secondary Fuel Shutoff • Skewed Stator • Rust-Proof Fasteners with Nylon Washers to • Permanent Magnet Excitation Protect Finish COOLING SYSTEM • Sealed Bearings • High Performance Sound-Absorbing Material • Closed Coolant Recovery System • Amortisseur Winding (Sound Attenuation Enclosures) • UV/Ozone Resistant Hoses • Full Load Capacity Alternator • Gasketed Doors • Factory-Installed Radiator • Stamped Air-Intake Louvers • 50/50 Ethylene Glycol Antifreeze • Upward Facing Discharge Hoods(Radiator and • Radiator Drain Extension Exhaust) • Stainless Steel Lift Off Door Hinges • Stainless Steel Lockable Handles • RhinoCoat'"-Textured Polyester Powder Coat Paint CONTROL SYSTEM • Date/Time Fault History(Event Log) • ReaVReactive/Apparent Power • lsochronous Governor Control • All Phase AC Voltage • Waterproof/Sealed Connectors • All Phase Currents • Audible Alarms and Shutdowns • Oil Pressure MRNMI • Not in Auto(Flashing Light) • Coolant Temperature • Auto Off/Manual Switch • Coolant Level • E-Stop(Red Mushroom-Type) • Engine Speed GENERAC ®I C • NFPA110 Level I and II(Programmable) • Battery Voltage • Customizable Alarms,Wamings,and Events • Frequency • Modbus®Protocol • Predictive Maintenance Algorithm Alarms and Warnings Digital H Control Panel-Dual 4x20 • Sealed Boards • Oil Pressure Display • Password Parameter Adjustment Protection • Coolant Temperature • Single Point Ground • Coolant Level • 16 Channel Remote Trending • Engine Overspeed • 0.2 msec High Speed Remote Trending • Battery Voltage Program Functions • Alarm Information Automatically Annunciated on • Alarms and Warnings Time and Date Stamped • Programmable Crank Limiter the Display • Snap Shots of Key Operation Parameters During • 7-Day Programmable Exerciser Alarms and Warnings • Special Applications Programmable Logic Full System Status Display • Alarms and Warnings Spelled Out(No Alarm Controller • Power Output(kW) Codes) • RS-232/485 Communications • • 3 Phase Sensing Digital Voltage Regulator Power Factor • 2-Wire Start Capability • kW Hours,Total,and Last Run I— w w PARALLELING CONTROLS • Maximum Power Protection • Optional Programmable Logic Full Auto Back-Up ccnn • Auto-Synchronization Process • Electrically Operated,Mechanically Held Controls(PLS) W • lsochronous Load Sharing Paralleling Switch • Shunt Trip and Auxiliary Contact y • Reverse Power Protection • Sync Check System • Independent On-Board Paralleling 2 of 6 SG150 I 9.0 L I 150 kW GENERAC` INDUSTRIAL INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CONFIGURABLE OPTIONS ENGINE SYSTEM GENERATOR SET CONTROL SYSTEM o Engine Block Heater o Demand Response Rating o NFPA 110 Compliant Level 1 21-Light Remote o Oil Heater o Extended Factory Testing(3 Phase Only) Annunciator o Air Filter Restriction Indicator o IBC Seismic Certification o Remote Relay Assembly(8 or 16) o Radiator Stone Guard(Open Set Only) 0 8 Position Load Center o Oil Temperature Indication and Alarm o Baseframe Cover/Rodent Guard o Remote E-Stop(Break Glass-Type,Surface o Level 1 Fan and Belt Guards(Enclosed Units Only) ENCLOSURE Mount) o Shipped Loose Critical Silencer(Open Set Only) o Weather Protected Enclosure o Remote E-Stop(Red Mushroom Type,Surface o Level 1 Sound Attenuated Mount) FUEL SYSTEM o Level 2 Sound Attenuated o Remote E-Stop(Red Mushroom Type,Flush 6 o NPT Flexible Fuel Line o Level 2 Sound Attenuated with Motorized Mount) o Dual Fuel NG/LPV Dampers o 10A Engine Run Relay o Dual Fuel NG/LPL o Steel Enclosure o Ground Fault Annunciator o Aluminum Enclosure o 100 dB Alarm Flom o AC/DC Enclosure Lighting Kit o 120V GFCI and 240V Outlets ELECTRICAL SYSTEM o Enclosure Heater o Damper Alarm Contacts(Motorized Dampers O 10A UL Battery Charger o Pad Vibration Isolation Only) o Battery Warmer o Up to 200 MPH Wind Load Rating(Contacto Auxiliary Circuit Breaker Contacts to Controller ALTERNATOR SYSTEM Factory for Availability) o Door Open Alarm Switch WARRANTY(Standby Gensets Only) o Alternator Upsizing o 2 Year Extended Limited Warranty o Anti-Condensation Heater o 5 Year Extended Limited Warranty o Tropical Coating o 7 Year Extended Limited Warranty o 10 Year Extended Limited Warranty CIRCUIT BREAKER OPTIONS o Main Line Circuit Breaker o 2nd main Line Circuit Breaker o Shunt Trip and Auxiliary Contact o Electronic Trip Breakers ENGINEERED OPTIONS ENGINE SYSTEM CONTROL SYSTEM o Coolant Heater Ball Valves o Battery Disconnect Switch w o Fluid Containment Pan w GENERATOR SET = ATLERNATOR SYSTEM o Special Testing a O 3rd Breaker System o Battery Box cn 3 of 6 SG150 I 9.0 L I 150 kW GENERAC INDUSTRIAL INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency APPLICATION AND ENGINEERING DATA ENGINE SPECIFICATIONS General Cooling System Make Generac Cooling System Type Pressurized Closed Cylinder# 8 Fan Type Pusher Type V Fan Speed(RPM) G18-2,330/G26-2,386* Displacement-in3(L) 543(8.9) Fan Diameter-in(mm) 22(559) Bore-in(mm) 4.49(114.3) Stroke-in(mm) 4.25(108) Fuel System Compression Ratio G18-10.5:1/G26-9.1:1 * Intake Air Method Turbocharged/Aftercooled Natural Gas,Propane Vapor/ Number of Main Bearings 5 Fuel Type Liquid Connecting Rods Forged Steel Carburetor Down Draft Cylinder Head Cast Iron Secondary Fuel Regulator Standard Cylinder Liners No EnergyFuel Shut Off Solenoid Standard Ignition High nton Type High n Alloy Operating Fuel Pressure-in H2O 7-11 (1.7-2.7) PiOptional Operating Fuel Pressure(LPL)—psi(KPa) 30-312(206-2,151) Crankshaft Type Forged Steel *When designing the external fuel system,assume a 20%safety factor to the upper Lifter Type Hydraulic Roller and lower limit of the specified fuel pressure range to account for site variation and Intake Valve Material Steel Alloy measurement at the generator test port.Refer to Generac 10000046207,latest rev, Exhaust Valve Material Stainless Steel for proper gas supply guidelines(Contact Factory for Details). Hardened Valve Seats Yes Engine Electrical System Engine Governing System Voltage 12 VDC Governor Electronic Battery Charger Alternator Standard Frequency Regulation(Steady State) ±0.25% Battery Size See Battery Index 0161970SBY Lubrication System Battery Voltage 12 VDC Ground Polarity Negative Oil Pump Type Gear Driven *G18 refers to all engines manufactured before August 3rd,2018.G26 refers to all Oil Filter Type full Flow Spin On Cartridge engines manufactured after August 3rd,2018. Crankcase Capacity:qt(L) G18-8.5(8.0)/G26-9.5(10.0) * I— W W = ALTERNATOR SPECIFICATIONS c' C, W Standard Model K0150124Y26 Standard Excitation Permanent Magnet rL cn Poles 4 Bearings Single Sealed Ball Field Type Revolving Coupling Direct Drive Insulation Class-Rotor H Prototype Short Circuit Test Yes Insulation Class-Stator H Voltage Regulator Type Full Digital Total Harmonic Distortion <5% Number of Sensed Phases All 4 of 6 Telephone Interference Factor(TIF) <50 Regulation Accuracy(Steady State) ±0.25% SG150 I 9.0 L I 150 kW GENERAC INDUSTRIAL INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency OPERATING DATA POWER RATINGS G18,G26-Natural Gas* G26-Propane/Dual Fuel* Three-Phase 120/208 VAC @0.8pf 144 kW Amps:600 kW Amps:558 Three-Phase 120/208 VAC @0.8pf 150 kW Amps:521 140 k Amps:486 Three-Phase 120/240 VAC @0.8pf 150 kW Amps:452 140 kW Amps:422 Three-Phase 277/480 VAC @0.8pf 150 kW Amps:226 140 kW s:211 Three-Phase 346/600 VAC @0.8pf 150 kW Amps:181 140 kW Amps. 69 MOTOR STARTING CAPABILITIES(skVA) skVA vs.Voltage Dip 277/480 VAC 30% 208/240 VAC 30% K0150124Y26 327 K0150124Y26 250 K0200124Y21 478 K0200124Y21 361 FUEL CONSUMPTION RATES* Natural Gas—scfh (m3/hr) Propane fh (m3/hr) Propane Liquid—gal/hr(Lph) Percent Load Standby Percent Load bland Percent Load Standby 25% 668(18.9) 25% 280(7.9) 25% 6.7(25.4) 50% 1,127(31.9) 50% 430(12.2) 11.4(43.2) 75% 1,583(44.8) 75% 573(16.2) 75% 15.7(59.4) 100% 2,042(57.8) 100% 720(20.4) 100% ) *1.5X maximum site rated fuel consumption should be used f)r gas supply design practices.Refer to Generac 10000046207,latest rev.,for more information or contact factory for details. COOLING Standby Air Flow(Fan Air Flow Across Radiator) cfm(m3/hr) 5,598(158.5) Coolant Flow gpm(Lpm) 27.5(104) Coolant System Capacity gal(L) 6.3(24.0) Maximum Operating Air Temperature on Radiator °F(°C) 122(50) Maximum Operating Ambient Temperature(Before Derate) See Bulletin 0199270SSD Maximum Radiator Backpressure in H2O(kPa) 0.5(0.12) COMBUSTION AIR REQUIREMENTS Standby Flow at Rated Power cfm—(m3/min) 343(9.7) ENGINE EXHAUST Standby Standby Rated Engine Speed RPM 1,800 Exhaust Flow(Rated Output) cfm(m3/min) 1,206(34.1) Horsepower at Rated kW** hp 229 Maximum Exhaust Backpressure inHG(kPa) 0.75(2.54) Piston Speed ft/min(m/min) 1,275(389) Exhaust Temp(Rated Output-Post °F(°C) 1,440(782) BMEP psi(kPa) 185(1,277) Silencer) w **Refer to"Emissions Data Sheet"for maximum bHP for EPA and SCAOMD permitting purposes. ti c.1 W fZ VJ Deration—Operational characteristics consider maximum ambient conditions.Derate factors may apply under atypical site conditions. Please contact a Generac Power Systems Industrial Dealer for additional details.All performance ratings in accordance with BS5514 and DIN6271 standards. Standby-See Bulletin 0187500SSB 5 of 6 SG150 I 9.0 L I 150 kW GENERAC INDUSTRIAL INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency DIMENSIONS AND WEIGHTS* OPEN SET(Includes Exhaust Flex) 1741% IIII L x W x H-in(mm) 116.5(2,959)x 49.7(1,262)x 55.6(1,412) ----� s H 2,946(1,336) (, Weight-lbs p..o . .. a-- • 0. II•r 1 L w MN MN WEATHER PROTECTED ENCLOSURE ME L x W x H-in(mm) 143.0(3,631)x 50.4(1,280)x 68.2(1,732 IMIZas ..&t . n Weight-lbs Steel:3,843(1,743) w Aluminum:3,384(1,535) limilll III' III H 1111 LEVEL 1 ACOUSTIC ENCLOSURE ISCIIIIIIIMMINEIMMIMIIIIIIN Ili, Lx Wx H-in(mm) 143.0(3,632)x 50.4(1,280)x 91.7(2,329) w Weight lbs Steel:4,321 (1,960) Aluminum:3,592(1,629) a me . B 0 to o LEVEL 2 ACOUSTIC ENCLOSURE w . a.. .. L x W x H-in(mm) 144.53(3,671)x 40.46(1,027.8)x 80.88(2,054.3) I w Weight-lbs Steel:3,789(1,719) Aluminum:3,207(1,455) *All measurements are approximate and for estimation purposes only. YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER I— uw W Z N U W Cl- cop Specification characteristics may change without notice.Dimensions and weights are for preliminary purposes only.Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. 6 of 6 Generac Power Systems,Inc. I S45 W29290 HWY.59 I Waukesha,WI 53189 I generac.com Part No.0K6450 ©2024 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev. K 11/01/2024 GENERAC ( INDUSTRIAL H-100 CONTROL PANEL The Quiet-TestTM'H-100 Control Panel is a digital microprocessor electronic controller that integrates all engine i .1 - and transfer switch functions into a single control system. 1111111 . • Digital Controls for All Saftey Shutdowns • Isochronous Governor Control GE____..E_ RRAC ® ® • Digital 3 Phase Sensing Voltage Regulator ® • Sealed Digital Circuit Board r J • Mates with HTS Transfer Switch and Any 2-wire Start ATS 5 • Alarm and Event Logging • - LOCFUSES ATED • Built-in Diagnostics INSIDE Ns..../ • Internal PLC Features • Two 4-line x 20 Displays • Shutdowns • Full System Status -Overvoltage • 3 Phase Sensing Digital Voltage Regulator -Overspeed • Remote Ports -Low Oil Pressure -RS-232 -High Coolant Temperature -RS-485 -Low Coolant Level -CANbus • Emergency Stop • Waterproof Connections • On/Off/Manual Switch • Built-in PLC • Not in Auto Flashing Light • Full Range Standby Operation • Audible Alarm for Fault Condition • Full System Status • Transfer Switch Logic Communicates with HTS -3 Phase AC Volts Transfer Switch -3 Phase Amps • Selectable Low Speed Exercise -kW • Temperature Range:-40°to+70°C -Power Factor -Reactive Power Codes and Standards -Oil Pressure • UL 508 -Water Temperature • Configurable to NFPA 110,Level 1 or 2 -Water Level -Oil Temperature(Optional) The generator set parameters can be manipulated and -Fuel Pressure monitored without standing in front of the control panel with -Engine Speed GenLink®software.The Generac H-100 control panel also -Battery Voltage wmonitors and controls transfer switch functions when used -Alternator Frequency with the HTS transfer switch. -Time • Monitors Utility Voltage -Date • Monitors Generator Voltage -Transfer Switch Status • Timer for Line Interrupt Delay in -Run Hours • Timer for Engine Warmup o -Service Reminders • Timer for Minimum Engine Run Time cc -Trending • Timer for Return to Utility Position z -Fault History(Alarm Log) • Timer for Engine Cooldown CL -121-Function for Full Generator Protection • Built-in Exerciser Timer(7 Day) o • Remote Communications • Additional 2-wire Start Controls for Any 2-wire Q • Programmable Auto Crank Transfer Switch w z w 1 OF Part No.0172110SBY Rev.F 02/08/23 GENERAL' I INDUSTRIAL k- ALTERNATOR DATA SHEET K0150124Y26 General Characteristics Voltages (V) 208/240 and 480 Number of Leads 12 Frequency(Hz) 60 Winding Type Reconnectable Phases 3 Air Flow(cfm) 1,000 Speed(rpm) 1,800 Total Harmonic Distortion(%) <5 Excitation System PMG Largest Single Harmonic Value(%) <3.5 Insulation Class H Telephone Interference Factor(TIF) <50 Winding Pitch 2/3 Reference Part Number 10000024485 Ratings at 0.8 pf based on 40°C Ambient 80°C Rise 105°C Rise 120°C Rise 150°C Rise Voltage(V) kW kVA kW kVA kW kVA kW kVA 208/240 115 144 138 172 150 187 160 200 480 115 144 138 172 150 187 160 200 Base Data at 480V,187 kVA,1800 RPM,60 Hz,3 Phase Description Value Description Value Stator Resistance, Line to Neutral,High Wye 0.0250 T"d, Direct Axis Subtransient Short Circuit Time 0.008 Connection(0) Constant(s) Rotor Resistance(0) 2.200 T'do,Direct Axis Transient Open Circuit Time 1.235 Constant(s) Exciter Stator Resistance-PMG(0) 5.5 Ta,Short Circuit Time Constant of Armature Winding 0.018 Exciter Rotor Resistance-PMG(0) 0.5155 (s) Excitation Winding Resistance-PMG(0) 1.3334 Phase Sequence CCW-NDE T1,T2,T3 Xd,Direct Axis Synchronous Reactance (p.u.) 3.03 Voltage Balance,L-L or L-N(%) 2.5 X2,Negative Sequence Reactance(p.u.) 0.27 Deviation Factor(%) 7 XO,Zero Sequence Reactance(p.u.) 0.03 High Wye Connection,Sustained 3-Phase Short 300 Circuit Current(%)-PMG only X'd,Direct Axis Transient Reactance(p.u.) 0.21 - X/R 7 X"d,Direct Axis Subtransient Reactance(p.u.) 0.16 Short Circuit Ratio 0.40 Xq,Quadrature Axis Synchronous Reactance(p.u.) 1.33 Heat Rejection (BTU/hr) 100%Rated Load,480V, T'd,Direct Axis Transient Short Circuit Time 0.8pf,120°C Temp.Rise 64,660 Constant(s) 0.054 Reference:Mil-STD-705B All Ratings are Nominal a Lc, c cc 0 CC w CD 10F2 Generac Power Systems,Inc. I P.O.Box 8 I Waukesha,WI 53187 Bulletin No.A0000186207 P:(262)544-4811©2019 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev.B 025/15/19 GENERAC& I INDUSTRIAL ALTERNATOR DATA SHEET K0150124Y26 sKVA 10% 15% 20% 25% 30% 35% 480 V @ 0.3PF 77 120 169 223 292 361 480 V @ 0.6PF 94 139 192 251 327 403 208/240 V @ 0.3PF 59 89 127 167 223 270 208/240 V @ 0.6PF 67 103 144 189 250 298 Efficiencies 480 @ 0.8 PF 480 @ 1.0 PF 208/240 @ 0.8PF 208/240 @ 1.0 PF 20%Rated Power* 79.9 81.1 80.8 81.8 40%Rated Power* 86.6 88.4 86.7 88.5 60%Rated Power* 88.4 90.9 87.8 89.9 80%Rated Power* 88.8 91.7 87.7 90.2 100%Rated Power* 88.8 92.1 87.4 90.4 *Rated Power value is rating kW at 120°C Winding Temp Rise and 0.8pt LOG LOG Decrement Curve Balanced 3-Phase Short Circuit Decrement&Thermal Damage Current Limit Curves 100000 -., — — _ . ..-.::.,•• l0000 -- - ,-r - t- . —^-- 208V Decrement Curve i ; ! -- 480V Decrement Curve c •»—240V Decrement Curve m a moo ----208V Thermal DEEE rve a — I I , 1 ----�480V Thermal D240V Thermal Drve Ij i j t I j i 208V Control System Shutdown 1 1 - i l l 1 I _ I I= ' 11 ( I 11 I —480V Control System Shutdown ; 7 I I i 100 1, I — 240V Control System Shutdown Q 1. r -I f � _ T I 1 t -1.� � --1 i .. ', ec --__ -+ - -r +, I 1 1— I t _. T_-' _ Z 4 I I � I a 1.0 _.�—____- --- -._— N 0.001 0.010 0.100 1.000 10.000 = O Time(s) co 20F2 Generac Power Systems,Inc. I P.O.Box 8 I Waukesha,WI 53187 Bulletin No.A0000186207 P:(262)544-4811©2019 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev.C 04/25/19 GENERAC' I INDUSTRIAL INDUSTRIAL GENSET - BATTERY INDEX •Warranty by Exide Corp.•Exide e-mail:tbgna@exide.com•800-782-7848 National Hot line INDUSTRIAL SPARK-IGNITED GENSETS-AVAILABLE BATTERIES GENERAC PART* Engine System Voltage Battery Quantity 058208 077483 058665 061119 061104 BT0015A02 (Group 24F) (Group 26) (Group 27F) (Group 31) (Group 8D) (Group 8D) G2.4 12 1 X G4.5 12 1 X X G9.0 12 1 X X G14.2 24 2 X G21.9 24 2 X G25.8 24 2 X G33.9 24 4 X G49.0 24 4 X X INDUSTRIAL DIESEL GENSETS-AVAILABLE BATTERIES GENERAC PART# 058665 061119 061104/ BT0015A02 Engine System Voltage Battery Quantity (Group 27F) (Group 31) (G�oup 8D) (Group 8D) D2.2 Perkins 12 1 X X D3.3 Perkins 12 1 X D4.5 FPT 12 1 X D6.7 FPT 100,130kW 12 1 X D6.7 FPT 150,175kW 12 2 X D8.7 FPT 24 2 X D10.3 FPT 24 2 X X D12.9 FPT 24 2 X X D12.5 Perkins 24 2 X D15.2 Perkins 24 2 X D16.0 Volvo 24 _ 2 X X D18.1 Perkins 24 2 X D30.6 Perkins 24 2 X X D33.9 MHI 24 2 X X D37.1 MHI 24 4 X X D49.0 MHI 24 4 X X 065.4 MHI 24 4 X X DIMENSIONS(in)NOMINAL Part Number Group Number* Nominal CCA @ 0°F L W H 058208 24F 525 6.75 10.63 9.00 077483 26 525 6.75 8.25 7.75 058665 27F 700 6.75 12.50 9.00 061119 31 925 6.75 13.00 9.40 061104/BT0015A00 8D 1,200 11.00 20,80 10.00 n BT0015A02 8D 1,400 11.00 20.80 10.00 -. 0 All batteries are 12V,6 cell construction,lead calcium type. c-c�. For 24V systems,batteries are wired in series. 0 -- X Battery available with electrolyte and installed in genset. LLI w *BC'Group Size reference. F- m 1 OF Generac Power Systems,Inc.1 P.O.Box 8 I Waukesha,WI 53187 Part No.0161970580 P:(262)544-4811 0 2024 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev.P 3/12/24 GENERAC' I INDUSTRIAL GENERATOR ENCLOSURES GENERAC INDUSTRIAL { DESCRIPTION GENERAC POWER SYSTEMS'generator enclosures provide year-round weather protection for your power equipment.Engineered with functionality and value in mind,the enclosure design benefits are unique in that the enclosures utilize dimensionally matched components for either a weather protective configuration or a sound attenuated/acoustic configuration.With common components used between design,modification and on-site upgrades can be accomplished with ease. The enclosure design offers several benefits over the"standard enclosures"of other manufacturers.Generac's enclosures have been created with the goal of maximizing the customer's product performance satisfaction while maintaining the functionality of reducing exterior noise levels and discouraging product tampering. Although others may require a"premium"for a self-enclosed exhaust system,rugged steel panel construction or protective polyethylene washers under all exterior panel fasteners,Generac includes these and several other features on every enclosure configuration.Be sure to compare.Generac Enclosures offer additional design enhancement extras that other"standard enclosures"do not. W CC ti J V W 1 OF 3 Doc No.0163180SBY Rev.E 06/10/19 GENERAC ( INDUSTRIAL GENERATOR ENCLOSURES Heavy Gauge,Stainless Post-Free Twin Doors Steel,Partial Pin Hinges with Provide Large,Unobstructed Nylon Spacers Service Access Durable,Corrosion-Free, illP Removable Doors Gasket-Free,Interconnected Roof - Panel Joint Drip-Free,Maintenance-Free «� i14, a i t — v.:--- -,x Two-Point Door Latch System Lockable Turn and Tuck Ensures Proper Seal Stainless Steel Latch Preventing Water Ingress �'"�:_ I Handle and Sound Egress , s Corrosion-Free, Non- Protruding and Secure 'Y 1 1 11 --- 1,,, Dense,Closed-Cell Foam Insulation with i Reflective Silver Mylar Layercc Improved Sound Attenuation Without Damaging = Effects From Radiant Heat Exposure c) J U w w 2 OF 3 Doc No.0163180SBY Rev.E 06/10/19 GENERAC` I INDUSTRIAL EATON CIRCUIT BREAKER DATA Standard (80% Rated) Thermal-Magnetic AMPS VOLTS ACCESSORIES EATON PART NUMBER SERIES FRAME GENERAC PART NUMBER No Accessories KG3350 0H9320TA00 350 Shunt Trip and Aux.Contacts KG3350Al2S43 OH9320TABO K-Frame No Accessories KG3400 0H9321TA00 400 Shunt Trip and Aux.Contacts KG3400Al2S43 OH9321TAB0 No Accessories LG3450 0H9322TA00 450 Shunt Trip and Aux.Contacts LG3450Al2S03 0H9322TAB0 No Accessories LG3500 L-Frame 0H9323TA00 500 Shunt Trip and Aux.Contacts LG3500Al2S03 0H9323TAB0 600 No Accessories LG3600 0H9324TA00 Shunt Trip and Aux.Contacts LG3600Al2S03 C 0H9324TAB0 , 700 No Accessories MDL3700 0H9325TA00 Shunt Trip and Aux.Contacts MDL3700A06S02 0H9325TAB0 M-Frame 800 No Accessories MDL3800 0H9326TA00 Shunt Trip and Aux.Contacts MDL3800A06S02 0H9326TAB0 900* 600 No Accessories NG3900 0H9327TA00 Shunt Trip and Aux.Contacts NG3900Al2S03 0H9327TAB0 No Accessories NG31000 0H9328TA00 1,000* N-Frame Shunt Trip and Aux.Contacts NG31000Al2S03 0H9328TAB0 No Accessories NG31200 0H9329TA00 1,200* Shunt Trip and Aux.Contacts NG31200Al2S03 0H9329TAB0 No Accessories RGH316033MY22 OH9360EANO 1,400* Shunt Trip and Aux.Contacts RGH316033MA12S21Y22 OH9360EANB No Accessories RGH316033MY22 0H9361 EANO 1,600* Shunt Trip and Aux.Contacts RGH316033MA12S21Y22 OH9361EANB No Accessories RGH320033M G RG-Frame 0H9367EAN0 2,000* Shunt Trip and Aux.Contacts RGH320033MA12S21 OH9367EANB No Accessories RGH325033M 0H9368EAN0 2,500* Shunt Trip and Aux.Contacts RGH325033MA12S21 OH9368EANB *LS-type electronic trip breaker equipped with RMS 310+trip unit. I C4 Cr W Q W Cr co F— C-) Cr C..) 20F2 Generac Power Systems,Inc. I P.O.Box 8 I Waukesha,WI 53187 Part No.0189370SSD iP:(262)544-4811©2020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev.F 4/3/20 GENERAC' I INDUSTRIAL BATTERY CHARGER 10 amp The Generac 10 amp 12/24 volt battery charger is = ; designed to work with Generac Industrial Controls and the G8601 to provide the ultimate in automatic battery voltage maintenance. ^:'"y The 10 amp charger has automatic float and equalize •-l-- , l `'. control.It precisely monitors the batterys voltage and G . r e • ,r ' automatically activates the correct charging mode.The mo , j I charge rate is limited and controlled to efficiently and } -., +. t r,t r - i `• I ` safely maintain ideal battery levels underr. I • ' .- 4", ' a�• • --= !* ':11 varying conditions. WO '~" ;;;., 0 .•:, ) --"... . t The equalize system uses a control circuit to limit 1 . charging current to 10 amps.When battery voltage -+ J `1 t drops below a preset level,charging current increases to ` '. 1 5 amps and then to the 10 amp charge rate if needed. j ••� ,,,ram 11'-11.. 4,f"E 1 :1 a !� When the battery reaches maximum charge,the charger t + . ,� i 1" -- -- ) s. s , - 4) — �� switches to float mode to suPM/1 st enough current to maintain the battery at or above 13/26 volts.Battery voltage and charging current are read at the control panel digital display. i3 ' 0 Battery charger shown from inside of control panel enclosure. Connections are made via an attached harness. Specifications 10A Nominal Input 120 VAC Operating AC Line Voltage Range 108 to 132 VAC Input AC Line Frequency 50/60 Hz Battery Fuse 15 A Nominal Charge Rate 10 A Equalize Voltage 13.8/27.6 V Float Voltage 13.0/26.0 V Current @ Equalize to Float Transition 5 A Battery Under-voltage shutdown 11/22 V LED Indicators Yes AC Line Voltage Green LED Battery Connected and Charging Yellow LED Battery Current Drain 30 mA AC Line Connection i Connector Plug Battery Connection ! Connector Plug Control Connection AC Power Fail Form Relay Form C 2 A Rating N CUL Recognized {Yes o cc NFPA 110 Compliant Yes z 0 AGM Compatible Yes L.) UL1236 Yes 0 a CSA 22.2 No.107 Yes cc z W i01i Generac Power Systems,Inc. I P.O.Box 8 I Waukesha,WI 53187 Part No.0191900SBY P:(262)544-4811 ©2023 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev.G 11/30/23 GENERAC I INDUSTRIAL COOLANT HEATER OPTION 1500 WATT, 120VAC C®US CE SPECIFICATIONS: LISTED VOLTAGE: 120VAC 127[5.0] 06.35[0.25] 108[4.25] (4)PLACES HEAT POWER: 1500W FIXED THERMOSTAT:60°-80°F • �, _38.1[1.50] HEATING ELEMENT: INCOLOY 800 76.2 O MAXIMUM PRESSURE:90 PSI (620 kPa) 1168 [3.0] [4.6] PLUG NEMA STD: 5-15P HOSE BARB TO FIT DIMENSIONS:mm[INCHES] OUTLET 5/8"I.D.HOSE (2)PLACES • • AllikAML MIAMI 170.2 [6.7] INLET 200.7 [7.9] 45.7[1.8] y O cc O V O H a cc W W C. 1OF1 Generac Power Systems,Inc. I P.O.Box 8 I Waukesha,WI 53187 Part No.0849180 P:(262)544-4811 ©2015 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. 05/13/15 GENERAC' I INDUSTRIAL WEATHER PROTECTED ENCLOSURE G9.OL Generac, SG/MG150 60Hz NO-LOAD, dB(A) DISTANCE: 7 METERS MICROPHONE OCTAVE BAND CENTER FREQUENCY(Hz) LOCATION 31.5 63 125 250 500 1,000 1 2,000 4,000 8,000 dB(A) FRONT 32 49 65 67 74 74 68 61 52 78 RIGHT 33 50 70 67 75 81 74 67 60 82 REAR 33 53 65 64 73 72 65 57 48 76 LEFT 34 51 65 68 77 82 76 67 60 84 AVERAGE 33 51 66 67 75 77 71 63 55 80 60Hz FULL-LOAD, dB(A) DISTANCE: 7 METERS MICROPHONE OCTAVE BAND CENTER FREQUENCY(Hz) LOCATION 31.5 63 125 250 500 1,000 2,000 4,000 8,000 dB(A) FRONT 30 57 70 70 77 75 71 64 57 • 80 RIGHT 33 53 75 — 70 76 81 75 69 63 : 84 __ REAR 32 56 72 66 74 73 65 59 53 78 LEFT _ 34 56 72 71 78 81 76 69 63 83 AVERAGE 32 56 72 69 76 77 72 65 59 81 RIGHT . 86 • • 84i FRONT I ® REAR 82 sow -� /,� 78 / LEFT , . 76 74 FRONT RIGHT REAR LEFT I • All positions at 23 feet(7 meters)from side faces of generator set. • Test conducted on a 100 foot diameter asphalt surface. • Sound pressure levels are subject to instrumentation,installation and testing conditions. • Sound levels are±2 dB(A). a cc a 0 0 z 0 tart Generac Power Systems,Inc. I P.O.Box 8 I Waukesha,WI 53187 Part No.0K9452A P:(262)544-4811©2020 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev.C 10/21/20 TX301 Series Transfer Switch GENERAC® INDUSTRIAL 100 —400 Amps Contactor Type Open and Delayed Transition Service Entrance Rated qty (1 ) 400A , 120/208 3p/4w 3pole NEMA3R SER • Automatic Transfer Switch • 100—400 A, up to 480 VAC, 60 Hz, 100%Current Rated CIENEGC • Single or Three Phase • 2,3, or 4 Poles • UL Type 1 or Type 3R • Open and Inphase or Open with Delayed Transition • ETL Listed to UL 1008 • High Withstand and Closing Ratings Image used for Illustration purposes only Codes and Standards Description Generac's patented* contactor is featured in the TX contactor (11). ETL Listed type transfer switch, which is a double-throw robust switch construction with inherent interlocks for safe positive transfer gij NFPA 70, 99, 110 between power sources. Featuring a transition time of less than NFPA 20 milliseconds, this high speed transfer is ideal for all applications, including motor load applications. The contacts are nec NEC 700, 701, 702, 708 silver composite for long life, resisting pitting or burning. The switches are rated for full load transfers in mission critical, OSHPD and Seismic Certified CBC emergency, legally required, and optional power systems. 2019, CBC 2016, IBC 2018, IBC 2015, The microprocessor based controller provides the customers �� OS i7pu IBC 2012, IBC 2009,ASCE 7-10, with the flexibility to program a comprehensive group of set —"" ASCE 7-16, ICC-ES AC-156 points to match the application needs. The controller has two programmable inputs and one programmable output as standard and is available with optional expansion boards for up to four programmable inputs and outputs. The LCD displays real time and historical information with time-stamped events. The integrated plant exerciser can be configured in off, daily, day of week, biweekly, and monthly intervals with user selectable run time. Standard features of the controller include three phase sensing on both sources, phase unbalance, phase reversal, load shed, emergency inhibit, and communications. W_ Ui W N O X H 1 of 3 *Patent Number:US 11,227,728 82 TX Series Transfer Switch GENERAC INDUSTRIAL TXC-100 Automatic Transfer Switch Controller • Automatic Transfer Switch Controller • Up to 480 VAC,50/60 Hz • Single and Three Phase • cETLus Recognized Component • Tested to UL 1008 • • l.. 112 IC=•,_._♦ O G O • • it • oao • um Image used for illustration purposes only Codes and Standards Description Not all codes and standards apply to all configurations.Contact Generac's TXC-100 microprocessor based controller provides factory for details. customers with the flexibility to program a comprehensive group of set points to match the application needs.The controller has 2 cETLus Recognized per UL 1008 programmable inputs and 1 programmable output as standard and is available with an optional expansion board for up to 4 NFPA 37, 70, 99, 110 programmable inputs and outputs. The LCD displays real time 0703 and historical information with time-stamped events. The NFPA integrated plant exerciser can be configured in off, daily, day of nec NEC 700, 701, 702, 708 week, biweekly, and monthly intervals with user selectable run time. Standard features of the controller include three phase sensing on both sources, phase unbalance, phase reversal, emergency inhibit, and communications. TX301 Series Transfer Switch GENERAC' INDUSTRIAL 100—400 Amps Contactor Type• Open and Delayed Transition • Service Entrance Rated STANDARD FEATURES GENERAL VOLTAGE AND FREQUENCY SENSING CONTROLS • Small Footprint,Results in Easy Mounting and • Three Phase Under and Over Voltage Sensing on • Front Programmable Control Reduces PPE Needs Installation for Reduced Time and Costs Normal and Emergency Sources and Arc Flash Hazard • Cable Entry is Top or Bottom(400A Units are • Under and Over Frequency Sensing on Normal • Built in Battery Backup-Increases Switch Reliability Bottom Only) and Emergency and Reduces Switch Transition Time to • Double-Throw,Stored Energy Transfer Mechanism • Selectable Settings:Single or Three Phase Voltage Alternate Source • Can be Electrically Isolated while Energized • Sensing on Normal,Emergency and Load 60 Hz • Battery Backup Able to Power the Controller for up • Graphical LCD-Based Display for Programming, • Phase Sequence Sensing for Phase Sensitive Loads to 60 Minutes in the Event of No Source Availability System Diagnostics and Help Menu Display Mimic • Accessible USB Port for Easy Data Downloads, • Diagram with Source Available and Connected Firmware Updates without Requiring PPE,Reducing Start Circuit the Risk of Arc Flash LED Indicator • Method of Transfer:Open with Inphase Transition • 2-Wire Start • All Amp Nodes Offered with Delayed Transition • Mechanically Interlocked to Prevent Connection of • 3-Wire Start From C Contact for Circuit Monitoring • Temper Programmable through Control for Desired Both So roes Temperature and Humidity Settings • Both Sod RTU Communications • Front Accessible Customer Connections • TXC 100 Controller Digital Outputs • Time-Stamped Event History Log • Operating Temperature-4°to 158°F • Signal Before Transfer(Elevator) • Programmable Exerciser Daily,Weekly, (-20°to 70°C) • General Alarm Bi-Weekly,Monthly • Removable Top and Bottom Plates for Ease of Entry • Voltage Agnostic* Digital Inputs • High Withstand and Closing Ratings • Heater Kit Standard on All 3R Enclosures • Emergency Inhibit(Permissive&Load Shed) • Auxiliary Output Includes:Two Wire Start,Signal • Go to Emergency(Demand Response) Before Transfer,Fault,and a Programmable • Manual Generator Retransfer Relay Output • Auxiliary Input Includes:Permissive Inputs (24 VDC) • General Alarm Indication • 2 Year Standard Warranty • IBC 2018,2015,2012,2009 *480 V 3-Wire Systems Must be Specified at Time of Ordering for Transformer Kit to be Included CONFIGRUABLE OPTIONS • Chicago Code Kit • 2 Year Extended Limited Warranty Engineered Options • 3R Padlockable Cover for Controller(Standard on • 5 Year Basic Limited Warranty • Transient Voltage Surge Suppressor(TVSS) 3R Enclosure) • 5 Year Extended Limited Warranty • 3R Padlockable Cover for Service Entrance Breaker • 7 Year Extended Limited Warranty • Manual Generator Retransfer Switch (Standard on 3R Enclosures) • 10 Year Extended Limited Warranty • Go to Emergency Switch • CTs for Integrated Metering • Generator Battery Backup for Controller Conversion Kits • Heater Option for Temperature and Humidity Control • 480 V Transformer Kit for 3-Wire Systems (Standard on 3R Enclosure) • Time Delay in Neutral Transition(TDN),or Inphase • UL Type 1 to Type 3R Kit with a Default to Time Delay in Neutral Transfer • Expandable Input/Output Board Module Includes: 4 Relay Outputs and 4 Optically Isolated Inputs • IBC Seismic Certified/Seismic Rated EE W O M 2of3 TX301 Series Transfer Switch GENERAC INDUSTRIAL 100 -400 Amps Contactor Type • Open and Delayed Transition • Service Entrance Rated UNIT DIMENSIONS* .0„3.,m 014 0. ee po e, 20P 47- O 0Q® 0Q0 WITS a"" 8 . Ili ... Il Io ° 9 hrii (rraI u ID ID ID ^+ - , i. o H'j:e JI1IJi ' �i L�,I o I� Mill L_ ` M 19 ° 0 M I r 0 . . . 01 Y i�� r e q - -xx IF 111111 t L 111 _ r I . '---[+ o +l I -_ (+ 0 +-I I ravel 2010790 100-200A 300-400A Service Entrance Rated,Contactor Type,Open and Delayed Transition,100-400 A in(ram) Cu/AI lbs(kg) Description A B C D E F G H J Kt L M N P Normal Standby Load Neutral Ground (Height) (Height) (Width) (Depth) (Dim) (Dim) (Dim) (Dim) (Dim) (Dim) (Dim) (Dim) (Dim) (Dim) 75°C Wire 75. Wi$6 wire 75'C Wire Connection Connection Weight 100ASER 51.3 47.5 21.2 12.0 9.5 10.6 38.3 14.5 12.6 1.5 1.7 10.1 5.8 3.1 (1)3/0-6 (1)2/0-14 (1)2/0-14 (5)2/0-14 (6)2/0-14 154.3 TYPE 1 (1,303) (1,206) (538) (305) (242) (268) (973) (369) (320) (38) (44) (257) (148) (79) (70) 100ASER 51.3 47.5 21.2 13.9 9.5 10.6 38.3 14.5 12.6 1.5 1.7 10.1 5.8 3.1 (1)3/0-6 (1)2/0-14 (1)20-14 (5)2/0-14 (6)20-14 158.7 TYPE 3R (1,303) (1,206) (538) (355) (242) (268) (973) (369) (320) (38) (44) (257) (148) (79) (72) 150A SER 51.3 47.5 21.2 12.0 9.9 10.9 38.3 14.5 12.6 1.5 1.7 10.1 5.8 3.3 (1)250-6 (1)250-6 (1)250-6 (5)350-6 (5)350-6 165.3 TYPE 1 (1,303) (1206) (538) (305) (253) (279) (973) (369) (320) (38) (44) (257) (148) (84) (75) 150ASER 51.3 47.5 21.2 13.9 9.9 10.9 38.3 14.5 12.6 1.5 1.7 10.1 5.8 3.3 (1)250-6 (1)250-6 (1)250-6 (5)350-6 (5)350-6 169.8 TYPE 3R (1,303) (1,206) (58) (355) (253) (279) (973) (369) (320) (38) (44) (257) (148) (84) (77) 200ASER 51.3 47.5 21.2 12.0 9.9 10.9 38.3 14.5 12.6 1.5 1.7 10.1 5.8 3.3 (1)250-6 (1)250-6 (1)250-6 (5)350-6 (5)350-6 165.3 TYPE 1 (1,303) (1,206) (538) (305) (253) (279) (973) (369) (320) (38) (44) (257) (148) (84) (75) 200A SER 51.3 47.5 21.2 13.9 9.9 10.9 38.3 14.5 12.6 1.5 1.7 10.1 5.8 3.3 (1)250-6 (1)250-6 (1)250-6 (5)350-6 (5)350-6 169.8 TYPE 3R (1,303) (1,206) (538) (355) (253) (279) (973) (369) (320) (38) (44) (257) (148) (84) (77) 300A TYPE 1 ER (1 305) (1,206) (860) (305) (253) (297) (228) (192) (562) (46) (59) (222) (166) (84) (2)600-2/0 1.4 47.5 33.9 12.0 9.9 11.7 9.0 7.6 22.1 1.8 2.3 8.7 6.5 3.3 (2)250-1/0 (2)250-1/0 (10)26 MCM 41/0 (5)350-6 or (118) 6 TYPE 3RR (1,305) (1,206) (860) (355) (2 3) (297) (228) (192) (562) (46) (59) (222) (166) (84) (2)600-7J0 (2)250 1/0 (2)250-1/0 ((10)250 MCM 41/0 (5)350-6 21 or 0) TYPE 1 ER (1 3 5) (1,206) (860) (305) (253) (297) (228) (192) (562) (46) (59) (222) (166) (84) (2)600-2 0 (2)250 0-1/0 (2)-4 or (1)250 1/0 (10)Z 0 MMCM M-41/0 or (5)350-6 (118) .6 TYPE 3RR (1,305) (1,206) (880) (355) (253) (297) (228) (192) (562) (46) (59) (222) (166) (84) ('600-21D (2)250-1/0 (2)250 1/0 (10)250 MM 41/0 or ()350 6 (120)12 t K Dimension for 100-200A 2-Pole Configuration is 3(75).K Dimension for 300-400A 2-Pole Configuration is 3.6(92) UL 1008 Withstand and Closing Ratings Ampere Rating Specific Breaker(kA)** Service Entrance(kA) Fuse Rating(Class J) Fuse Size W 100 35 35 35 kA 200 A LU 150 42 42 100 kA 200 A C6 200 42 42 100 kA 200 A p 300 65 65 100 kA 400 A M X 400 65 65 100 kA 400 A ~ *All measurements are approximate and for estimation purposes only.Specification characteristics may change without notice.Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings. **See Specific Breaker List available on GENconnect. 3 of 3 Generac Power Systems,Inc. I P.O.Box 8 I Waukesha,WI 53189 Part No.A0000416970 P:(262)544-4811©2022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Rev.D 11/21/2022 i x - K§1 dN o w —c. i ....tg— 00iir CP gas Ntga Zo -O o - WIN 4: li sE i „ d © Oy $ -I JpM s e t -- - ` _ 11 .4Cr'••y -Z ':=3 . 1.9 It W (..2.. tar l'i �._�•j ° S IR 44 �i. w Sit ta I.�� • f �m - H 1 �i F �� ' ...., r..., ,.... ....„ ...5. . i lit i I f 80 .r... 11' 1 ,.I 'arF sW g .... :o _ o� N 111 13§ I.r N'` 1 I �R a fag Wa Nag 0 M M $ m^ - �sFu lgF Q ii : .., - 2 .4--I < cod jJj jw tz4: 2 i tF �< 2 ..r.a w6 F= -Wo<m_ N 11 = t`dW_"%5 o owtw�� ��W a y = w o�No ? �f 1 �► oaw�o�w w - No= =<Woow� . i � n oo.i 2, Wog a-'11 - � g-tT.1= m m2Wo 1' gg �E o« w- � . ..Eaw eta tC n't,","< oo tootoow< .-.E.m -�4m 1 _ g ai W (:: m '>w2 oN " "<"V"1-gmHi Wa zo.iu .;.: . _ wO" Wo d W: s -- ., t i l o>a� Q u} _ oW rc.n awwu-O `:"".2 IIfA � _ � • 0o mm>i w -- - worm iaL ox OsFw o x -- Q ON4:t*r OJE n._ v, i-m��'=i0ima 2LL< wOii�u, -<:.,j gl VWQ �n Q .E.n:'oe ,:. - 8�3 I:JCI tffa,a uo, giii _ oor�1 Im :,o <FFoz ,�W" . �"J(J o.-woo - <o6�-_,i oao.o=.w _ s., ,,. g9 i / 0 �_+ �j oi��arc Wizw _ ar-c`oa <wzWh'�w�2�o 3 atgg `toin // _`oa��zii - zoc�w-.n Eiu <.�-cswi :. �<w�LLr_ °- -- o«oom<cw 'uW�usm<W Eomx<w<:moo o'"0 7$3� CC W v M cc I— ." Q o < COa �W M �' YFjt S N tp ll !it IIV' D W O N a. W ="o �o =N r �' : z m`�N z r • a R F g • N'0,1. . H z I• S� `o 0 0 0 �M W z o O F �a N_ • *� ' �� ♦vim Z� W`F.2o - = 4 7. = : 3 . . , e 0 0 - . 1 V 0 en a. > . / a RE,: ...., ..... — . V , E R. _,_ I wi 11 .-ig. • ,,, 14 • i 11:::: 0 1 -g 0 enPf M I •I^ ° ram) ,.,, 0 • 0 6 1 [1 0 a ffw '0.- ROf Vvl / 1 1 _4_ Y :ii 1.... . . ••1 I ril g : :: VIOWi / I I 01 .MI7 Q� g -0,8 N ies ! ..W. igt CO I < co I I- Ws_ s _ W i7 O N N O o CL ps ',T. W � Z I 0� �NN a-\ o - XO 0\_NVZ •.V\ O Z O . G_. O C7 O- M . tM Z O _ g 0 4 n. CD CO Z.', - NwH m ■11111Ell NI MI 1 -- - W 51 = = _ 19 1 __a • • —• , I- an Yr o Y Ma • • • i A e a 0 A A • . • a az S§ ig N N • • .21 us _ • O 0 M _ , _ M o e 11 $ /• ^�Q \ O'i N N •/V R J 8 (13 S 88 \ . . . . g T C: HoL s .. rc .., am x El s �11�UVVV��LVLU�JIII� a -cito W . SyyV WF Stilt O s JW 0n 014[00.55] 350[13.78] y 08[00.31] r 20[0.79] 9 O O ,c 3R COVERS �� �. ON 3R (��= UNITS 1 1 0 ONLY • ri r1 r' " L_,.. - tiJ L-- 1...I ) �1----`J----1� `� "� J O 0 0 , 111 6L OQ 0 O 1 O • J a4. ' IL l.J O O 01 0 S0� S� O D U f 0 0 o O O O 1 „F„ - „M„ ( ) O O O 0 + 20[0.79]-f ALL DIMENSION ARE.mm[inches] HEIGHT HEIGHT WIDTH DEPTH DIM DIM DIM DIM DIM DIM DIM DIM DIM DIM DESCRIPTION "A" "B" "C" "D" "E" "F" "G" "H" "J" '.K•. "C' •,M.. N "P.. WEIGHT 1305 1205 860 305 251 297 228 192 562 46 59 222 166 84 118kg 300A SER NEMA 1 [51.38] [4746] [33.86] 112.00] [9.90] [11.70] [8.97] [7.56] [22.13] [1.81] [2.32] [8.73] [6.52] [3.32] 259.61bs 1305 1205 860 355 251 297 228 192 562 46 59 222 166 84 120kg 300A SER NEMA 3R - [51.38] [47 46] [33.86] [13.99] [9.90] [11.70] [8.97) [7.56] [22.13] [1.81] [2.32] [8.73] [6.52] [3.32) 264.01bs 1305 1205 860 305 251 297 228 192 562 46 59 222 166 84 118kg 400A SER NEMA 1 [51.38] [47.46] [33.86] [12.00] [9.90] [11.70] [8.97] [7.56] [22.13] [1.81] [2.32] [8.73] [6.52] [3.32] 259.61bs 1305 1205 860 355 251 297 228 192 562 46 59 222 166 84 120kg 400A SER NEMA 3R [51.38] [47.46] [33.86] [13.99) [9.90] [11.70] [8.97] [7.56] [22.13] [1.81] [2.32] [8.73] [6.52] [3.32] 264.0Ibs REVISION:D ID TX SWITCH SERVICE ENTRANCE 3-POLE 300A-400A REVISION DATE:10/06/2020 A0000430689(DRAIMNG:A0000561085) NOT TO SCALE Generac Power Systems 2 Year (2B) Limited Warranty for Industrial Transfer Switch Systems For the period of warranty noted below,which begins upon the successful start-up and/or on-line activation/registration of the unit,Generac Power Systems, Inc. "Generac"warrants that its transfer switch will be free from defects in material and workmanship for the items and period set forth below. Generac will, at its discretion, repair or replace any part(s)which, upon evaluation, inspection and testing by Generac or an Independent Authorized Service Dealer, is found to be defective.Any equipment that the purchaser/owner claims to be defective must be evaluated by the nearest Independent Authorized Service Dealer. Warranty Coverage in Year(s):1 Warranty Coverage in Year(s):2 Parts,Labor and Limited Travel Limited Parts Only Guidelines: 1. Unit must be registered and proof of purchase available. 6. Enclosures are warranted for the first year of ownership only. 2. Any and all warranty repairs and/or concerns must be performed Damage caused after receipt of generator is the responsibility of and/or addressed by an Independent Authorized Service the owner and is not covered by this warranty.Nicks,scrapes, Dealer,or branch thereof.Repairs or diagnostics performed by dents or scratches to the painted enclosure should be repaired individuals other than Independent Authorized Service Dealers promptly by the owner. not authorized in writing by Generac will not be covered. 7. Proof of performance of all required maintenance must be 3. Warranty is transferable between ownership of original available. installation site. 8. Travel allowance is limited to 300 miles maximum or seven and 4. Generac may choose to repair,replace or refund a piece of a half(7.5)hours maximum(per occurrence,whichever is less) equipment in its sole discretion. round trip from the nearest Independent Authorized Service 5. Warranty only applies to permanently wired and mounted units. Dealer.Any additional travel required will not be covered. The following will NOT be covered by this warranty: 1. Costs of normal maintenance(i.e.associated part(s), 10.Steel enclosures that rust as a result of improper installation, adjustments.installation or start-up). location in a harsh or salt water environment,or are scratched 2. Damage to the transfer switch system caused by accidents, where the integrity of applied paint is compromised. shipping,handling or improper storage. 11.Fuses,light bulbs and any related labor. 3. Damage/failures caused by operation with loads or installations 12.Units sold,rated or used for"Prime Power,""Trailer Mounted"or other than what's recommended or specified by Generac. "Rental Unit"applications as defined by Generac.Contact an Unauthorized modification/misapplication will not be warranted Independent Authorized Service Dealer for definitions. unless authorized by Generac in writing. 13.Failures caused by any act of God or external cause including 4. Rental equipment used while warranty repairs are being without limitation,fire,theft,freezing,war,lightning,earthquake.. performed and/or any extraordinary equipment used for removal windstorm,hail,water,tornado,hurricane,or any other matters and/or reinstallation of transfer switch(i.e.cranes,hoists,lifts, which are reasonably beyond the manufacturers control. et.al.). 14.Shipping costs associated with expedited shipping. 5. Planes,ferries,railroad,buses,helicopters,snowmobiles,snow- 15.Any incidental,consequential or indirect damages caused by cats,off-road vehicles or any other mode of transport deemed defects in materials or workmanship,or any delay in repair or not standard by Generac. replacement of the defective part(s). 6. Failures due to normal wear and tear,accident,misuse,abuse, 16.Any unit built/manufactured prior to 2014 models, neglect,improper installation,or improper sizing. 17.Overtime,holiday or emergency labor. 7. Damage to any covered components or consequential damages 18.Living or travel expenses of person(s)performing service, caused by the use of a non-OEM part will not be covered by this except as specifically included within the terms of a specific unit warranty. warranty period. 8. Damage related to rodent,reptile,and/or insect infestation. 9. Repairs or diagnostics performed by individuals other than Independent Authorized Service Dealers not authorized in writing by Generac. THIS WARRANTY SUPERSEDES ALL OTHER WARRANTIES,EXPRESSED OR IMPLIED.SPECIFICALLY,GENERAC MAKES NO OTHER WARRANTIES AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.ANY IMPLIED WARRANTIES WHICH ARE ALLOWED BY LAW, SHALL BE LIMITED IN DURATION TO THE TERMS OF THE EXPRESS LIMITED WARRANTY PROVIDED HEREIN. SOME JURISDICTIONS DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS,SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.GENERAC'S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S)AS STATED ABOVE.IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC'S NEGLIGENCE.SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS.YOU COULD ALSO HAVE OTHER RIGHTS UNDER APPLICABLE LAW. FOR AUSTRALIA ONLY: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. FOR NEW ZEALAND ONLY: Nothing in this warranty statement excludes, restricts or modifies any condition, warranty right or remedy which pursuant to the New Zealand Legislation(Commonwealth or State)including the Fair Trading Practices Act of 1986 or the Consumer Guarantees Act 1993("CGA")applies to this limited warranty and may not be so excluded,restricted or modified.Nothing in this statement is intended to have the effect of contracting out of the provisions of the CGA,except to the extent permitted by that Act,and these terms are to be modified to the extent necessary to give effect to that intention.If you acquire goods from Generac Power Systems or any of its authorized resellers and distributors for the purposes of a business,then pursuant to section 43(2)of the CGA,it is agreed that the provisions of the CGA do not apply. GENERAC POWER SYSTEMS,INC. • P.O.BOX 8 • Waukesha,WI,USA 53187 Ph:(888)GENERAC(436-3722) • Fax:(262)544-4851 To locate the nearest Independent Authorized Service Dealer and to download schematics,exploded views and parts lists visit our website:www.generac.com Part No.0J4302 Revision H(4/21)