HomeMy WebLinkAboutPR 24717: PURCHASING OF CHEMICAL PUMPS FOR THE WATER TREATMENJT PLANT City of 'r— „rr rthu r Texas INTEROFFICE MEMORANDUM Date: December 23, 2025 To: The Honorable Mayor and City Council Through: Ronald Burton, CPM, City Manager From: Calvin Matthews, P.E., Director of Utilities RE: PR 24717—Purchasing of Chemical Pumps for the Water Treatment Plant Introduction: The intent of this Agenda Item is to seek City Council's approval to purchase(6)Watson Marlow peristaltic chemical pumps and(10)replaceable pump heads with Environmental Improvements Inc. of Houston, TX, in the total amount of$49,585.00. This is a sole-source provider and is considered to offer a fair and reasonable price for the required work. Background: The Water Treatment Plant operates several chemical feeding pumps that are responsible for treating drinking water. The existing pumps are over 11 years old and require upgrades and replacement to significantly increase reliability for processes that ensure continuous public health and safety, as well as to facilitate integration into the existing System Control and Data Acquisition program in use. Environmental Improvements Inc. of Houston,TX has provided a sole-source quote for(6)Watson Marlow peristaltic chemical pumps and(10)replaceable pump heads in the amount of$49,585.00. Budget Impact: Budget impact is $49,585.00 for the chemical pumps and replaceable pump heads at the Water Purification Plant. Funding is available in Account No.410-40-210-5318-00-00-000,Equipment Maintenance. Recommendation: It is recommended that the City Council approve P. R. No. 24717, authorizing the purchase of chemical pumps and replaceable pump heads at the Water Treatment Plant as described and outlined above. "Remember,we are here to serve the Citizens of Port Arthur" P. R.No. 24717 12/22/2025 CS-TNR RESOLUTION NO.- A RESOLUTION AUTHORIZING THE CITY MANAGER TO PURCHASE SIX (6) WATSON MARLOW PERISTALTIC CHEMICAL FEED PUMPS AND TEN (10) REPLACEABLE PUMP HEADS FROM SOLE SOURCE PROVIDER ENVIRONMENTAL IMPROVEMENTS, INC. OF HOUSTON, TEXAS, IN AN AMOUNT NOT TO EXCEED $49,585.00. FUNDING IS AVAILABLE IN ACCOUNT NO. 410-40-210-5318-00-00-000 (EQUIPMENT MAINTENANCE). WHEREAS, the City's Water Treatment Plant relies upon chemical feed pumps to properly treat drinking water and ensure compliance with public health and safety standards; and WHEREAS, the existing chemical feed pumps have been in service for more than eleven (11) years, have exceeded their reliable functional lifespan, and are in need of replacement to maintain operational integrity and system reliability; and WHEREAS, replacement of these pumps will significantly improve reliability for critical treatment processes and will allow seamless integration with the City's existing System Control and Data Acquisition(SCADA) system; and WHEREAS, Environmental Improvements, Inc. of Houston, Texas has provided a sole- source quotation for six (6) Watson Marlow peristaltic chemical feed pumps and ten (10) replaceable pump heads in the total amount of$49,585.00, attached hereto as Exhibit"A"; and WHEREAS,Environmental Improvements,Inc.has demonstrated a history of dependable service to the City and is the sole authorized provider for this equipment; and WHEREAS, the City Council finds that this purchase is necessary and in the best interest of the City to ensure the continued safe and reliable treatment of the City's drinking water supply. NOW THEREFORE,BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PORT ARTHUR,TEXAS: P. R.No. 24717 12/22/2025 CS-TNR THAT,the facts and opinions in the preamble are true and correct; and, THAT, the City Manager is hereby authorized to purchase six (6) Watson Marlow peristaltic chemical feed pumps and ten (10) replaceable pump heads from Environmental Improvements,Inc. of Houston,Texas,in the total amount not to exceed$49,585.00(Exhibit"A"); and, THAT, this purchase shall be funded by the Utility Operations Account No. 410-40-210- 5318-00-00-000 (Equipment Maintenance); and, THAT a copy of the caption of this resolution be spread upon the minutes of the City Council. READ, ADOPTED AND APPROVED THIS day of , 2026 at a Regular Meeting of the City Council of the City of Port Arthur, Texas,by the following vote: AYES: Mayor ; Councilmembers: NOES: Charlotte M. Moses Mayor ATTEST: Sherri Bellard City Secretary P. R. No. 24717 12/22/2025 cs Page 3 of 3 APPROVED AS TO FORM: Roxann Pais Cotroneo City Attorney APPROVED FOR ADMINISTRATION: -trx Ronald urton, C City Manager Ji .ei Y1,z411, Suhail Kanwar, P.E. Director of Public Services Calvin Matthews, P.E. Water Utilities Director APPROVED AS TO THE AVAILABILITY OF FUNDS: Lynn yn) Boswel , MA ICMA-C Finance Director ,(- AA: Clifton . Williams Jr. CPPB Purchasing Manager Exhibit "A" (Sole Source Letter and Quote) :WATSON MARLOW Innovation in full flow. . . Watson-Marlow Bredel Alitea Flexicon MasoSine To Whom It May Concern From Bill Schiller Copies Date 16 OCT 2025 Subject Environmental Improvements, Inc. Exclusive Representation in State of Texas This memo will confirm to all parties that Environmental Improvements, Inc. (E12) is the exclusive environmental representative for Watson Marlow Pumps Group in the state of Texas. This includes the municipal, state, and federal water and wastewater treatment markets for all Watson Marlow tubing pumps and Bredel hose pumps. Should you wish to contact Environmental Improvements, Inc., please do so at one of the following offices: •Environmental Improvements, Inc. Environmental Improvements, Inc. 1183 Brittmore, Suite 100 517 North Kealy Houston, TX 77043 Lewisville, TX 75057 713-461-1111 972-436-2536 blake(a ei2water corn fwillmsIa ei2dallas.corn Environmental Improvements, Inc. 235 Trademark Drive Buda, TX 78610 512-295-3733 phenegar(c�ei2austin.com Please do not hesitate to contact me if you need further assistance. I Regards. 111/.91a. William D. Schiller District Sales Manager. Environmental Division Office: 281-890-6290 Fax: 281-890-6235 Cell: 713 299 5455 bschiller(c�wmbpumps.corn Watson-Marlow, Inc. •37 Upton Technology Park • Wilmington, MA 01887•www.watson-marlow.com• (978)658-6168 2 environmental EI improvements Inc. 1183 Brdtmoore RD 100 Quotation Houston.TX 77043 ph 713.461.1111 Customer: City of Port Arthur DATE: 1/12/26 Attn: Jeff Wyble DELIVERY: 3-4 Weeks Phone: (409)548-1076 TERMS: Net 30 Email: jeff.wvbleatportarthurtx.Qov FOB: Factory We are pleased to have the opportunity to offer you the following quotation.Please sign and fax back along with your purchase order or alternate method of payment. ;Item Qty Article Part Number Description unit Extended Coagulant 1 2 0M6.605T.GRA Watson Marlow Qdos H-Flo(Drive Only) $ 7,210.00 $ 14,420.00 115VAC,Universal+Controls 4-20mA 2 4 0M3.8200.PFP ReNu 600 pumphead Santoprene(158 GPH) $ 785.00 $ 3,140.00 /PFPE 5 bar(36 psi) Sodium Hydroxide 3 2 0M6.605T.GRA Watson Marlow Qdos H-Flo(Drive Only) $ 7,210.00 $ 14,420.00 115VAC,Universal+Controls 4-20mA 4 4 0M3.7200.PFP ReNu 300 pumphead Santoprene(79.4 GPH) $ 785.00 $ 3,140.00 /PFPE 5 bar(36 psi) Polymer(Emulsion) 5 2 0M0.355L.GRA Qdos 60 PU Universal+ $ 5,350.00 $ 10,700.00 115VAC, 15.9 GPH,at 75 PSI 6 2 0M3.3500.PFP ReNu pumphead-Spare-PU Tubing w/PFPE $445.00 $ 890.00 7 1 Freight Freight&Tariff to Port Arthur $ 2,875.00 $ 2,875.00 Total $49,585.00 By signing below you authorize Environmental Improvements,Inc.to provide the above mentioned items. Thank you, Blake Roye Signature Date Print Austin Dallas Houston Tulsa qdos 20 30 60, 120 and CWT qdc)s • . Perh taltic Metering --FEATURES AND BENEFITS Watsor1-Marlow Pumps. • Flow rates 0.1-2000m1/min (0.001-31.7USGPH) and up to ,i,_ 7 bar(100psi) RMS pressure , • 32 A . • ReNu pumphead provides accurate, linear and repeatable flow : Y^ A • Process uptime is maximised with no gas-locking, no valve,,. -•- blocking and rapid no-tools pumphead replacement '$ • Fluid recovery ensures operator safety and avoids chemical waste • Flow control up to 20000:1 with ±1%accuracy #:. • Manual, analogue, PROFIBUS or contact mode functionality available • PROFIBUS Bus speed 9.6-1,500 kb/s • Compatible with 12-24V DC I� /� }`y,2 [{YEAR S lsokr_/ a m...(maua ion 61 Full RRailT V vGt PERFORMANCE qdos pump typical flow rates qdos I qdos remote Speed(rpm) Flow ml/min(USGPH)• Speed(rpm) Flow ml/min(USGPH)• qdos 20 0.017-55 0.1-333(0.001-5.3) 0 034-55 0.2.333(0.003-5.3) qdos 20 PU 0.017.55 0.1484(C.001-7.67) NA NA qdos 30/qdos CWT 0.025-125 0.1-500(0.001-7.93) 0.078-125 0.3-500(C.005-7 93) qdos 60 0.013-125 __ _ 0.1-1000(0.001-15.85) 0.078-125 0.6-1000(0.01-15.85) qdos 120 0.006-125 0.1.2000(0.001-31.7) 0.078-125 _1.25-2000(0.02-31.7) *accuracy±1%,repeatability±0 5% Flow rate with discharge pressure for ReNu pumpheads Suction gauge Discharge gauge Suction gauge Elscharge gauge pressure/psi pressure/psi pressure/psi pressure/psi -15 -10 -5 0 0 20 40 60 80 100 -15 -10 -5 0 0 20 40 80 00 100 2200 ' 22000 { --- ,r 2000 !� 30 2000 '32 — 1600 1800 ��—28 1800 2630 2g 1400 22 �, 140Q 20 ] E — gdos�0- — gdos30- �22 ▪ 1200 c z 1200 —Santoprene orSE85—. Santoprene -.20 ar ° e ' 18 a or Tubn Tubin On 18 a+ ., 1000 -xa a_..> gym.,; - 18 .* 1000 _ 9 _ 9 b —.18 A —14 m 800 Santoprene or 3 4 o SE85 Tubing Santoprene 100 0 o soD qdos OMIT — qdos OW 10 ; 0 w G00 u (r 8 LL 800 Fe 400 PU Tubing 8 400 3 200 2 200 f2 -1 -0.5 0 0 1 2 3 4 5 8 7 -1 -0.5 0 0 1 2 3 4 5 8 7 Suction gauge Discharge gauge Suction gauge D scharge gauge pressure/bar pressure/bar pressure/bar aressure/bar qdos 120 qdos 30/qdos CWT i gdos 60 qdos 20 I,qdos 20 PU K" `i *' 0 ' - . • - .- • _ . . , qdos 20 qdos 30 qdos 60 I qdos 120 qdos CWT Ingress rating IP66 Enclosure Watertight/dustproof Humidity Non-condensing 5%-95% Temperature(Santoprene) N/A 5C-45C(41 F-113F) N/A Temperature(SEBS and PU) 5C-40C(41F-104F) N/A N/A Temperature(EPDM) N/A 5C-40C(41F-104F) Drive weight 4.6 kg(101b 2oz) 4.1 kg(91b 1oz) 4.6 kg(10ib 2oz) Pumphead weight 1.1 kg(2Ib 7oz) 0.95kg(21b 2oz) 1.1kg(2lb 7oz) 2.2kg(4Ib 140z) Control ratio±1%accuracy 3330:1 5000:1 10000:1 20000:1 5000:1 Control ratio(Remote) 1600:1 N/A Noise <70dB(A)at lm Standard CE,NSF 61,cETLus,IRAM 5 Mark,C-Tick,CSA Switch mode power supply -100-240V 50-60Hz 190VA Country specific plug options Power supply options 12-24v DC power supply Typical 12V current(100W).10A Typical 24V current(100W)=SA Terminal connectors:M8(5/16")studs(hole diameter 8.33mm(0.328") MATERIALS OF CONSTRUCTION Component Material qdos 20 I qdos 30 I On 60 I qdos 120 I qdos CWT Keypad Polyester Drive casework 20%Glass filled PPE/PS Drive shaft Stainless steel 440C Pumphead enclosure 30%Glass filled PPO/PS I 40%Glass filed PPS 130%Glass filled PPO/PS 40%Glass filled PPS Rotor PP(gdos 20 PU)/Glass Glass filled nylon Stainless steel filled nylon Rotor bearings Steel,stainless steel(optional—contact Watson-Marlow applications) Tube* PU(max 4 bar.60 psi)/ ll I Santoprene(max 7 bar,100 psi)/SEBS(max 4 bar,60 psi) N/A SEBS(max 7 bar,100 psi) Membrane* N/A [Polypropylene 111 EPDM puomphead hydraulic PVDF(SEBS or PU) I Polypropylene(Santoprene)1 Polypropylene(Santoprene)or I Polypropylene Polypropylene(Santoprene) or PVDF(SEES) PAN(SEES) I(Santoprene) ene) or PVDF(SEES) Hydraulic connectors Polypropylene(standard)PVDF(optional) Lubricant* PFPE based *It is the users responsibility to comply with local health and safety regulations,including ensuring chemical compatibility between the duty fluid,the tube and lubricant contained in the ReNu Pumphead.For guidance refer to www.gdospumps.com. TECHNICAL DATA . 1 Operational modes Manual Remote PROFI11U5 Universal UMversal+ Manual • • PROFTBUS—bus speed 9.6-1,500 kb/s • Contact • • 4-20mA • Fault reporting • _ • Features Manual Remote PROFIhUS Universal Universal+ Numerical flow display • Numerical speed display • • • Fluid level monitor ' • • Ii Max(prime) Auto restart(after power restored) • _ • Fluid recovery Leak detection • • 3.5"(88.9mm)colour TFT display • j - • LED Pump status icons • f E NICAt •A A C e HUED _ " .- Control methods Manual Remote PRORBUS Univerftl Universal* Input/Output Options* L L L or I I.or R Manual control capability i • _ i 4-20mA input • • -"J 4-20mA Input two point calibration , 4-20mA output • Contact Input(pulsefbatch) •L or 1 •I.or R 0 Run stop input • Run status output L Alarm output L Four configurable relay outputs R Remote fluid recovery • • PRORBUS Manual Remote PROFtsUs Universal Universal. Speed set point 0 Speed feedback Flow calibration function • --N- Hours run Revolution counter 0 Leak detection Low fluid level alarm Diagnostic feedback • 1 Security Manual Remote PROFIBUS Untwesfal Universal* Keypad lock • • PIN lock to protect set up • Power supply options Manual ; Remote PROFIBUS Unlvemal Universal+ 12-24V DC • ' I -100-240V AC j ' •Control options-Universal and Universal.models Variant Standard pump(L) Input 5-24V DC Output Open collector Variant Relay Module(R) ,Input 5-24V DC or 110V AC Output Contact rating 110VAC,4A 30V DC,4A Y t 9 $ R A �' ;: _ !� " H { eii 7 I li. 1-4( I kk B D F Note:Pumphead appearance and fluid port positions may differ between models. Modal A R C D E-Optional f 6 H I relay modules (H or R) qdos 20 234mm(9.2) 214mm(8.4") 104.8mm(4.11 266mm(10.5") !43mm(1,7") 173mm(6.8') 40mm(1.6'} 140mm(S.5') 10mm(0.4") i • qdos 30 234mm(9.2") 214mm(8.4") 71,5mm(2.8") 233mm(9.2") i 43mm(1.7") 173mm(6.81 40mm(1.6") 140mm(5.5") lomm(0.41 r qdos 60 234mm(9.2") 214mm(8.41 104.8mm(4.1") 266mm(10.5") i 43mm(1.T) 173mm(6.8") 40mm(1.6") 140mm(5.5") lomm(0.41 qdos 120 234mm(9.2") 214mm(8.4") 104.8mm(4.11 266mm(10.5") i 43mm(1.7") 173mm(6.8") 40mm(1.6") 140mm(5.51 10mm(0.4") I I galas CWT 234mm(9.2) 1214mm(8.4") 117.9mm(4.6") 291 rnm(11.5") 143mm(1.7") 173mm(6.8") 40mm(1.6") 140mm(5.51 lomm(0.4") ORDER INFORMATION 0 M 0 • • • • G • • Moroi Model Plug options ' .7;;0..2' Fluid path Inateriali ,. ti,.,,,., .y '.'1; a- .•c: !: tla-mat Pttmphea0 L.Eurt-. ,, t For guidance on chemical o - F,.,. compatibility see 4. r - >t orientation' l7 m R .. wvrN.gdospumps tom A F, IP1:;; I_ 1... Is. i•„i o ,., Digital I/O typo -. v Manual,Remote and PROFIBUS models ~ 73 universal and Universal.model. Pumphead product codes T. 3 ; Description Partcode o ••Iss.,Ar ",,,,, ReNu 20 pumphead PU/PFPE 4 bar(60ps1) 0M3.1500.PFP 7 ReNu 20 pumphead SEBS/PFPE 7 bar(100psi) DM3.1800.PFP o v, ReNu 30 CWT pumphead EPDM/PEEK/PFPE 7 ar(100 psi) 0M3.5700.PFP 3 ReNu 30 pumphead Santoprene/PFPE 7 bar(11)psi) 0M3.2200.PFP ry ReNu 30 pumphead SEES/PFPE 4 bar(60ps1) 0M3.2800.PFP ry ReNu 60 pumphead Santoprene/PFPE 7 bar(1appsi) 0M3.3200.PFP cn *The pumphead side location Is required when ordering.The left/right ReNu 60 pumphead SEBS/PFPE 4 bar �' perspective assumes the user Is looking at the front of the pump.The pump P P (60ps1) 0M3.3800.PFP c in the dimensions diagram Is considered a pumphead located to the left. ReNu 120 pumphead Santoprene/PFPE 4 bar(Cps') 0M3.4200.PFP tJ AN flow rates shown were obtained pumping water at 20C(68F)with zero suction and delivery heads.qdos drives are i ; g, not ATEX rated and should not be used within explosive atmospheres. r wmftCCm Disclaimer.The information contained in this document is believed to be correct but Watson-Marlow Limited accepts ".<., u- ..-.. �. -...,.= y in no liability for any errors it contains and reserves the right to alter specifications without notice.It is the users f_ ;.; 0 M' info@wrnftg.como responsib airy to ensure product sultabiFh�yy for use within their application.Watson-Marlow,Qdos,ReNu,LoadSure. C +44(0)1326 370370 7 of a...w�"..........�.."...d.......o .r w�""..�u.1... i...a...• rr•e,me en,w a er•n,lee or'c,w.... ,C.,F,:,,•_.» 0 c2azi .. Qdos H - FLO tyl il F=L.0 W Pumps Qdos metering pump . Features and benefits • Qdos*H-FLO offers flow rates up to 600 L/h and pressure capability up to 7 bar • RFID Pumphead detection ensures confirmation of correct pumphead ., - • Revolution counter for pumphead service maintenance • One common pump drive with several pumphead options for changing process conditions and chemistries AO ▪ Network integration,control and communication options include EtherNet/IP, it PROFIBUS and PROFINET • Optional pressure sensing kit with configurable alarms for process monitoring - _ 4 Performance (Maximum) Pumphead Flow rate Discharge pressure Fluid temperature ReNu 150 Santoprene 150 L/h(39.6 USGPH) 7 Bar(100 PSI) 45°C(113°F) ReNu 300 Santoprene 300 L/h(79.4 USGPH) 5 Bar(73 PSI) 45°C(113°F) ReNu 300 SEBS 300 L/h(79.4 USGPH) 4 Bar(58 PSI) 40°C(104°F) ReNu 600 Santoprene 600 L/h(158.5 USGPH) 2.5 Bar(36 PSI) 45°C(113°F) Performance curve inlet pressure PSI Discharge pressure PSI -15 -10 -5 0 0 20 40 60 80 100 -175 600 150 500 -125 d CO - 100 y 7 m tu 300 75 a ReNu 300 sei..3:,, tc Se Santoprene or ""`""'`" 200 SEBS -50 100 ReNu 150 -25 Santoprene 0 .- I -1 -0.5 0 0 1 2 3 4 5 f 7 Inlet pressure bar Discharge pressure bar EN-US-Version 2.0 v- Technical Specification Max,flow rate 1 600 L/h Max.flow rate' 158.5 USGPH Min.flow rate' 0.12 L/h Min.flow rate' 0.032 USGPH Max.operating pressure 2 7 bar Max.operating pressure 2 100 PSI Ambient Temperature Range 4 to 45°C Ambient Temperature Range 39 to 113°F Weight 3 15 kg Weight 3 33 lbs Control types Manual,Universal,Universal+,EtherNet/IP,PROFIBUS,PROFINE' Power supply 100-240 VAC 50-60 Hz 350 VA Ingress rating IP66,NEMA 4X humidity 80%up to 31 °C,88°F,decreasing linearly to 50%at 40°C,104°t Noise <70dB(A)at 1 m Max.altitude 2000 m Standards UL 61010-1:2012 Ed.3,CAN/CSA-C22.2 NO.61010-1-12(R2022),E71160204-1:2018, CC 47CFR(Part 15),EN 61326-1:2021,EN 301 489-1 (17), NSF 61,IkoHS, PSE 'Minimum and maximum flow depends upon pumphead,flow unit and method of control. 2 Maximum pressure depends upon pumphead 3 Combined weight of drive with pumphead fitted,maximum for range shown Qdos H-FLO dimensions ;1 • . _ =w.: • gin: Q m E o_......r,,....F-,.s_ zN. K H 7... I F � • F - • I • C • - D C; 1 • A B C D E F mm in mm In mm in mm in mm in mm in 276.0 10.866 35.0 1.378 224.0 8.819 260.0 10.236 33.7 1.327 !91.5 11.476 G H I J K L mm in mm in mm in mm in mm in mm in 380.0 14.961 118.7 4.673 334.3 13.161 394.2 15.520 332.3 13.083 432.0 18.976 EN-US-Version 2.0 V' Control options Operational modes Manual Universal Universal+ EtherNet/IP PROFIB S PROFINET Manua' • • • • • • Bus Network Communication • • • Contact mode • • 4-20 mA • • Fault reporting • • • • • • \ Features Manual Universal Universal+ EtherNet/IP PROFIB S PROFINET R9D pumphead detection • • • • • • 11 Numerical flow display • • • • • • Numerical speed display • • • • • • Fluid level monitor • I • • • • Max(prime) • • • • • • Auto restart(after power restored) • • • • • • Fluid recovery • • • • • • Leak detection • • • • • • 5"(127 mm)colour TFT display • • • • • • Pressure sensing(optional • • • • • pressure sensor) IControl methods Manual Universal Universal+ EtherNet/IP PROFIB • PROFINET Input/Output options M or T M or T M M M 11 Manual control capability • • • • • • 4-20 mA input&calibration • • 4-20 mA output • 111 Contact input(pulse/batch) • • Pressure Sensor input(pressure • • • • • sensor purchased separately) IManual speed adjustment range* 1900:1 1900:1 1900:1 1900:1 1900:1 1900:1 Minimum drive shaft adjustment speed increment 0.1 0.1 0.1 0.1 0.1 0.1 4-20 mA resolution 2184:1 2184:1 Run stop input • • • • • Run status output • • Alarm output • • Two configurable relay outputs • • • • • Four configurable relay outputs • Remote fluid recovery input • • • • • *Speed adjustment range depends upon pumphead chosen,maximum shown III EtherNet/IP,PROFIBUS and Manual Universal Universal+ EtherNet/IP PROFIB S PROFINET PROFINET functions Speed set point • • • Speed feedback • • • Flow calibration function • • • Hours run • • • Revolution counter • • • �■1 Leak detection • • • Low fluid level alarm • • • Diagnostic feedback • • • Pressure sensing(optional • • • pressure sensor) Security Manual Universal Universal+ EtherNet/IP PROFIB S PROFINET Keypad lock • • • • • • PIN lock to protect setup • • • • • • Input/Output control connection options-Universal and Universal+models only M:M12 connectors T:User-wired cable gland conn tors Input Analogue:4-20 mA,Digital:24V IEC61131-2 Type 3 Analogue:4-20 mA,Digital:24V IEC61131-2 T iiie 3,AC:110VAC IIOutput Analogue:4-20 mA,Digital:Relay-CO 1A 24VDC Analogue:4-20 mA,Digital:Relay-CO SA 110 •C,SA 30VDC EN-US-Version 2.0 t�. Materials of construction Wetted by Potential of Potential of the process being wetted by being wetted by fluid the operating operating the environment or pumphead to a spillage the point of tubing failure Pumphead Part Material ReNu Santoprene ReNu SEBS Santoprene SEBS • • • GF PP PVDF ■ ■ • Fluid path PVC-U • • • FKM • • • GFPPE+PS • • PC • • NBR • • Pumphead enclosure • • Stainless steel Santoprene • • PP • • GF PA6 • Santoprene • HDPE • Pumphead internals • Steel Silicone • PFPE based lubricant • Polyester • Information labels PET • Drive Part Material GF PPE+PS • PC • Polyester • PA6 • NBR • Drive enclosure Silicone • Santoprene ■ Stainless steel • Zinc alloy,nickel plated, • (M12 connector(M)model only) FKM(M12 connector(M)model only) • Polyester • Information labels PET • Power cable(product code PVC(outer sheath) • ending in A) Power cable(product code PCP(outer sheath) • ending in B,C,D,E,K,R,U) Drive internals Mixture of materials,including Aluminium* *The drive enclosure has been tested to IP66 and NEMA 4X.Chemical incompatibility with any of the above lisle materials,physical damage,misuse or failure to follow Watson-Marlow instructions could result in loss of ingress protection and ex ose the internal components of the drive to chemicals used in the fluid path or environment.Aluminium contained within the dri,e may react aggressively with these chemicals. EN-US-Version 2.0 Drive product code 0 M 6 6 0 G E � ■ C 7 A B C D Input/Output Pumphead •wer plug Model connectors orientation p 9 3:Manual Models:Manual,PROFIBUS, L:Left A: S 4:Universal EtherNet/IP,PROFINET R:Right B: :razil 5:Universal+ models C: ' iss 7:PROFIBUS D: dia,South Africa 8:EtherNet/IP M:M12 Connectors E: t ropean 9:PROFINET K: ustralia Models:Universal, R: rgentina Universal+ U: K M:M12 connectors T:User-wired cable gland connectors Pumphead product code Description Pr'duct code ReNu 150 pumphead Santoprene/PFPE 7 bar(100 psi) ,M3.6200.PFP ReNu 300 pumphead Santoprene/PFPE 5 bar(73 psi) 1M3.7200.PFP ReNu 300 pumphead SEBS/PFPE 4 bar(58 psi) 1 M3.7800.PFP ReNu 600 pumphead Santoprene/PFPE 2.5 bar(36 psi) iM3.8200•PFP Disclaimer: All flow rates shown were obtained pumping water at 20°C(68°F}with zero suction and delivery heads.The information contained in is document is believed to be correct but Watson-Marlow Limited accepts no liability for any errors it contains and reserves the right to alter specifications wit •ut notice.It is the user's responsibility to ensure product suitability for use within their application.Watson-Marlow,LoadSure.Rumps'',PureWeld XL,Bioprerie Marprene are registered trademarks of Watson-Marlow Limited.Tn-Clamp is a registered trademark of Alfa Laval Corporate AB.GORE and STA•PURE are regist ed trademarks of W.L. Gore and Associates,Please state the product code when ordering pumps and tubing. wmfts.com/global ❑•'• 0 '._4 • FL. o. 18 July 2023 EN-US-Version 2.0