Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PR 24957: CONTRACT WITH CHOPAIR FOR THE INSTALLATION OF INDUSTRIAL FANS
t rthuy— t' Texas www.PortArthurTx.gov INTEROFFICE MEMORANDUM Date: June 15,2026 To: The Honorable Mayor and City Council Through: Ron Burton, CPM,City Manager From: Chandra Alpough, CPM, CPRP,Director of Parks and Recreation RE: P.R. 24957—Contract with ChopAir for the Installation of Industrial Fans at the Downtown Pavilion Introduction: The intent of this Agenda Item is to request the City Council's approval of P.R. No. 24957., authorizing the City Manager to enter into a contract with ChopAir of Kansas City, Missouri, 1 for the installation of High-Volume, Low-Speed Fans at the Downtown Pavilion in the amount of$27,689.00. Background: The City of Port Arthur Parks and Recreation Department operates the Downtown Pavilion as a community venue for public events,festivals,recreational programming,and special gatherings. Installing industrial high-volume,low-speed fans would improve air circulation, enhance patron comfort, reduce heat buildup within the Pavilion, and increase the Pavilion's usability during periods of elevated temperatures. The Parks and Recreation Department solicited quotations from multiple vendors for the purchase and installation of HVLS fans at the Downtown Pavilion, and the quote tabulation is attached hereto as Exhibit "A". After evaluating the quotations received, ChopAir, of Kansas , City, Missouri, submitted the lowest responsive quote and best value to the City in the amount of$27,689.00 for the turnkey installation of two(2)24-foot Epic Colossus Industrial HVLS fans in the main Pavilion area and two (2) Chop20 fans in the stage area, including all necessary mounting hardware, controllers,electrical connections, and related installation services. 4 Budget Impact: Funding in the amount of$27,689.00 is available for this purpose in the Parks and Recreation Capital Improvement Account Number 307-25-06.7-8525-00-10-000 PR0029.OTH.FAN Recommendation: It is recommended that the City Council approve P.R. No.24957,authorizing the City Manager to enter into a contract with ChopAir of Kansas City, Missouri, for the installation of High-Volume, Low-Speed Fans at the Downtown Pavilion in the amount of$27,689.00. "Remember,we are here to serve the Citizens of Port Arthur" P.O.Box 1089 X Port Arthur,Texas 77641-1089 X 409.983.8182 X FAX 499.983.8294 P. R. #24957 06/15/2026 ca-tnr RESOLUTION NO. A RESOLUTION AUTHORIZING THE CITY MANAGER TO EXECUTE A CONTRACT WITH CHOPAIR OF KANSAS CITY, MISSOURI, FOR THE PURCHASE AND INSTALLATION OF HIGH-VOLUME, LOW- SPEED (HVLS) FANS AT THE DOWNTOWN PAVILION IN THE AMOUNT OF $27,689.00; FUNDING AVAILABLE IN PARKS AND RECREATION CAPITAL IMPROVEMENT ACCOUNT NUMBER 307- 25-067-8525-00-10-000 P R0029.OTH.FAN WHEREAS, the City of Port Arthur Parks and Recreation Depattuuent operates the Downtown Pavilion as a community venue for public events, festivals, recreational programming,and other civic gatherings; and WHEREAS, the installation of High-Volume, Low-Speed (HVLS) fans at the Downtown Pavilion will improve air circulation, enhance patron comfort, reduce heat accumulation within the facility, and increase the Pavilion's usability during periods of elevated •`; temperatures; and WHEREAS, the Parks and Recreation Depai(Anent solicited quotations from multiple vendors for the purchase and installation of HVLS fans at the Downtown Pavilion, and the quote tabulation is attached hereto as Exhibit"A"; and WHEREAS, after evaluating the quotations received; ChopAir, of Kansas City, Missouri, submitted the lowest responsive quote- and best value to the City in the amount of $27,689.00 for the turnkey installation of two (2) 24-foot Epic Colossus Industrial HVLS fans in the main Pavilion area and two (2) Chop20 fans in the stage area, including all necessary mounting hardware,controllers, electrical connections,and related installation services; and WHEREAS, the City Council finds that awarding the contract to ChopAir is in the best interest of the City, attached hereto as Exhibit"B";and WHEREAS, funding for this project is available in the Parks and Recreation Capital Improvement Account No.307-25-067-8525-00-10-000 P R0029.OTH.FAN NOW THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PORT ARTHUR,TEXAS: Section 1. That the facts and opinions in the preamble are true and correct. P.R.#24957 06/15/2026 ca-tnr Section 2. The City Manager is hereby authorized to execute a contract, attached hereto as Exhibit "B", with ChopAir, of Kansas City, Missouri, for the purchase and installation of two (2) 24-foot Epic Colossus Industrial HVLS fans in the main Pavilion area and two (2) Chop20 fans in the stage area, including all associated mounting hardware, controllers, electrical connections,and related installation services,in the total amount of$27,689.00. • Section 3. Funding for this project is available in the Parks and Recreation Capital Improvement Account No. 307-25-067-8525-00-10-000, P R0029.OTH.FAN Section 4. That a copy of the caption of this Resolution be spread upon the Minutes of the City Council. READ, ADOPTED AND APPROVED THIS day of , A.D., 2026, at a Regular Meeting of the City Council of the City of Port Arthur,by the following vote: AYES: (Mayor) Councilmembers: NOES: 1I Charlotte M. Moses Mayor ATTEST: Christe Whitley Ned City Secretary VASOST FORM: ' Roxann Pais Cotroneo, Esq. City Attorney P. R. #24957 06/15/2026 ca APPROVED AS TO ADMINISTRATION: /llk Ron Burton, CP City Manager Chandra Alpough, CPM Director of Parks and Recreation APPROVED AS TO AVAILABILITY OF FUNDS: girn..Boswe Director of Finance Clifto Williams, CPPB Purchasing Manager Exhibit "A" 1 i Y i 1 I cii cc G xL 3.1E 00 4 V o Gs ad a d 1 I 00 cri W 0 5 liti ccn a 'S Coo • 0 p� ° a ,,-1N et i.4 N o M o Htio apbW oft a ca on o el . t' CO a .0 r VD,, U U 2 GS 0 .,-1 a •� �o rn rn a) A F.T.4 C c �' H cG ;\�1to_ ► a V i L Q O Z � U EXHIBIT "B" r OF-Iqo Fix. IR WE ' RE YOUR BIGGEST FAN ChopAir Quote - City of Port Arthur - Pavilion updated 6 122026 (REVO) �I City of Port Arthur Reference:20260612-175704679 Port Arthur,TX 77640 Quote created:June 12,2026 p Quote expires:September 10,2026 'Quote created by:Dave Barroni Johnny Brown Business Development'; johnny.:brown@portarthurtx.gov li dave@chopaircoin 409-983-8166 +17135040933 • I • Comments from Da e Barron • Sales Tax to b added Unless Tax Exempt&Proper Paperwork Is Provided Prior To Order Release I • Leadtime is 2 to 3 weeks Notes: -The qty(1)24�T Colossus Fan in Center of Pavilion and qty(2)Chop20 Fans in.tage area your price would be$19, 39.00 -(plus tax if not exempt) Products&Services Item&Description SKU Qty Epic Colossus Industrial HVLS Fan-24 FT Diameter,460-480V/30;Black Color Package EPIC-CIF- 2 HVLS-1&2(Installed in Main Pavillion Area) 24-43-B Industrial HVLS Fan;2-Stag Helical Gearbox;2.0 HP;5 Airfoils:NEMA 1 DisconnectNFD Assembly;Saf ty Cable &Guy Wires;Lifetime Parts arranty;15-Year M i chanical Warranty;7-Year Electrical Warranty 1-Year C ntrols Warranty 1-Year Labor Warr nty;UL Listed;MICA Certified I i � I I Item&Description SKU Qty ChopAir Chop20 Fan- tandard White with Blue Blades CHOP- 2 '[2]Chop20 HVHS Fan;20"Diameter;240V/10(Stage Area) CAHF-20 20"EC Motor Fan — ChopAir ChopFan Adjustable Mount-up to 6'Length CHOP-CF- 2 Chop20 Mount Kits(Stage Area) { AM6 ChopAir ChopFan Adjustable Mount-up to 6'Length ChopAir Chop Multi Fan ControllerCHOP- 1 Controller for Chop20 Fans(Stage Area) i MFC • Controls up to 2 groups of 2 l fans per group. • Item&Description SKU Qty Mechanical+Electrical Installation Mechanical+Electrical Installation Scope of Work: • Turnkey installation(2)24'Epic Colossus fa'is. • Installation of fans usin I-Beam kits. • Installation of VFD's o ide of blade sweep • Installation of individua controllers to be wittfin 100'of fan location. • Installation of(1)240V 1 phase circuit to supply fans. • Termination of all elect cal inside of panel a lnd inside of VFD's. • Turn on circuit and test fans in forward and averse for 15 minutes. • Turnkey installation of )20"Chop20 HVHS fans. Installation of fans using adjustable 6ft mount. • • Installation of(1)Chop it controller to be wi hin 100'of fans. • ChopAir will supply a 32'scissor lift. • All work areas need to oe clear and accessible by lift. • Additional labor hours lay apply with site a ailability and restrictions. ` • Work out of scope is n•t included. • Change orders settled:s incurred. Exclusions: • Permits. • After normal business ours. • Spotter for equipment. • Any other equipment t.perform work safely. • Fire Alarm. • Warranty on any existi g wiring,devices,or-quipment or that supplied by others. • The warranty does not•uarantee the condition/suitability of existing circuitry. • Any repairs or modiftca ions to existing circu try that are not on this quote. One-time subtotal $26,989.00 1 Shipping&Handling $700.00 Total $27,689.00 Purchase terms By signing this agreemen,you are acknowledging that you have accepted the Terms&Con itions of Sales in the link below: Terms&Conditions of Sa es-https://www.chopair.com/terms-and-conditions/ ! 1 Signature Signature Date Printed name Questions?Contact me Dave Barron Business Development dave@chopair.com +17135040933 ChopAir 1519 West 16th Street Suite 100 Kansas City, MO 64102 USA LOCATION: Port Arthur, TX 1!1 pi\ R. OWNER/DEVELOPER: • Port Arthur Pavillion DWG:, 002807 Drawn By:PL REV:O SCALE NTS SHEET INDEX: I.COVER SHEET 2.Fan Layout& Airflow Design-2 Fan Option 3.Fan Layout& Airflow Design-I Fan Option LEGEND Dave Barron' Business Development 17131504-0933 ---.--- P 9 dave@chopair.com I. [2] Epic Colossus I-1VLS Gear Box Drive Fan;240V/I0; 24ft Diameter;Black Colo Package;I-Beam Mounting Kit;Tags: HVLS-1, HVLS-2 2. Nominal Airflow Diameter - I l0ft 3. General Airflow Diameter - 130ft 4. Red Boxes = Main Electrical Panel/ Electrical Sub Panels 5. Peak Height = 33' 6" 6. Eave Height = 30' 6" 7. Peak Beam Height = 30' 8" 8.Eave Beam Height = 25' 10" I.[2] Chop120 HVHS Fan;20" 9. 3ft Extension Tube drops fan 24' 8"AFF Diameter; 40V/l0;Standard 48ft 24R Adustabl Mount;Multifan 1—Aaoa ch...p 2 +�. 23R4 Controller Tag: Cho 20-I, Cho 20-2 Man j ---""'- �f "-"_lir \. 2. Hang ro ghly 15ft AFF oeawaal Pawl\ '"Elecbicd -5� Electrical' /,(_, Sub Pale1 -fW5� I Sub Patel + \ iGP- "^tlwp20-1\\ f\ I /' -1-- I 1 1 1- 1 1 i 1 ' 1 1 1 � \1 ' bleb.1 1 ' 1 I 1 1 I ( ' 1 t I Ten 30n-�1 i 1 i 1--,j 1 `. n-Itln l l i `��- l ' i i I FNLS-2� i I 249 St, . \ , ; Electrical ,^\ Electrical 5 138R Sub Panel \i \/ Sub Patel / I 1 Ten \\ / 0118R ..` 0 241[J \ `' '�i %\, ..I-- ' -1 a,c I nu. _ \ --------- % \ ------------- ,/ a,aa CHOP/AIR •�_____i I-�__,_ --- ,i0. w"Port Arthur Pavillion 181R �u>sm msa 00 *xus oo�v...sucnrau 0�� 0 O22807 I0 ,nrta,rtom y� i I I I.[I] Epic Colossus HVLS Gear Box Dri r Fan;240V/10;24ft Diameter;Black Color Package;1-Beam Mounting Kit;Tags: HVLS-I 2. Nominal Airflow Diameter - I IOft 3.General Airflow Diameter - 130ft 4.Red Boxes = Main El ctrical Panel/ Electrical Sub Panels 5.Peak Height= 33' 6" 6.Eave Height = 30' 6" 7. Peak Beam Height= 30' 8" I.[2] Chop2 l HVHS Fan;20" 8. Eave Beam Height = 25' 10" Diameter;2,OV/I0;Standard 9. 3ft Extension Tube d-ops fan 24' 8" AFF Adjustable Mount; Multifan Controller;Tag:Chop20-I,Chop20-2 1 stye-1 tlwp20.2 —24n-.- Man dr`�J5n-5 231t.4in 2. Hang roughly 15ft AFF �Eleci trPanelica Electrical Sub Panel' � -I Sub Patel / r 1 ran % \ ; 1 ' i ' 33f6 I } i n ` * t I 73n 3af i t ' 1 FNLS-I ' 41-10in 241t Stands \ \J ' \ ` 1 ,1 1 • I 1 leant• ; 1 • �a,;� I 78ft Sub Panel : Sub Pmte1 i 0 24R '`�'- r-' ' / i^.c 0 3 �.' ----- / ,^ I CHOP�IR 0 130ft ___ . 191ft /' "^" 1 Port Arthur Pavilion uaraofati m aemawsnrm Dr- 0028070 1 a-.•nisr I.••Jwv �a { 1 i E EPIC FANS COLOSSUS INDUSTRIAL HVLS FAN PRODUCT SPECIFICATIONS ,,, ,N. ,.. . itv. ,,-....40,:c, .4k.• ,N-431--...,,,sb-k%,s,,,..„.. Ailii& ,,,,,,,1.-.~-',".„. -,-, Z *,,4tx./..- id. , \ klii.,-10",:tikt. N.:k-v.."11vV-ti:.10.,,,Eittlillittk,'- '‘',--, ‘", -.ATPc". _ 1%, \ ......,---0,_A;lk, -NV.i... itilio, ,1/4 'Nt..,. - ilk, t \N. Ow ., ‘ fir / - `�1 �, �,� : F L ...fi iv t41\411 • \ \ i ..0400.00. '417. '-1*„4ii. r ,.. . \ _re-1 _ -.44.,,,. -- . - 1,-- , gb., -..,____*,,t:Olv+,. iiirivv-v,..1.4, -- 1 ' \ P:_---- -..N/, 41kv-t":', .,„,,, A' ----5*,,NV r --.,i,..*-• '111fr.6.1W - t,,,,,..01314k,-,,ov.Av. I a .,,tea �►''-- �o.� =a -- 1�4 �' / 1Ft��` s�►--- ' frik /1 41*- ' lie-, ...Ahliit,„ t.,..,.1 1>---1, , , . . „ _ *sm. ���, ``l.-R\�1 A2 -- -� ;, �i ,,N - , 91 � a� i �_dm �ors ��•.?� \►,� 4t \t P, g vost ;Vfie � 3�a ai s+� fr:� a� � �r_ ���- ti 1► i( \1" O� �`z}1 � 4. M#, " 7✓l+ ��i�a".„�..a S"' i t +�� �� �� .\ �,��" \tf al\ � ," ..+� L�. S,"ati, �� •�+._ ,s���5a:'. ` 1R, y4�+$I �r>.o a��Ti� '�i �- ��- +' ^►� use. ti@'>>aL ♦ rit# n ram+* Tc•� 1 ` sir .F Jro y� ,tir , ■ ♦ -..-�, x+' ' ,r^. - lv" ..rb��Y1`ri� -a►�iy1i�, , \Iwo ''' <�■':. `" 1 k6T� `"..: .. ".,.vw^,�c .7.a,,r t r r �. r�i...r e�� �Iw� -IP ����y��. �r � �s�'�rc•�c" ,�, "•S � �� .a +7..='� n .v 6�'-( c•.R Erl1 P� �`` ir..:. �• _I")G`_•. / �� t' �o-s x y,. 'r ,�-pYa L + s..s. v �• \i r1.^^` i cz-. F/�!.i,.ys>to .x,.; .-'^a ■ �Y �ti ,... • ` „ r. --"a ems._.>7 �-ar= �- �� ,rn:e�^- .',•.a.r�o;•c-- ,, i ce, 6�••- �-4uy'�G �f-R^ MFLa .. _ l{{ u� I • 1 -mew. �'" r -'---•_•- . AIM l `Z MA� I �W' :> ' T- - ,;. + , n .1ffilla ilitta, ,MIMI i �- -;_ ,. II _M p�� ' Mkt 1 i { I3 kif.�'= ' '�'. = --� B 9 �` emit i l I I I i him. yi rY 4 ,,,, SrFS ) I s. 4 �♦ pi _Ti q�- . ,�'- - _ s�i t JWd Li-1 _ I�; r ix c� ( law it-NEK I r r�L� rl. i :� �, I Y r�s �. �_1 _;,�_." T .-.ie. — •- .1 ti Ut 1 .. 1 . Te,au i,'-_ .`4 . 1- -z .`���,^art K•r 4`t fl 1`_- '�~t• i a ... .pi f Project Information Construction or Engineering Approval Job Name Port Arthur Pavillion Address Port Arthur, TX By Company Contractor Distributor ChopAir Address Model.24' Quantity 2 Voltage/Phase 240V/10 Date lin CO3US MADE IN USA LISTED Epicfan.com E506041 0 EPIC FANS COLOSSUS INDUSTRIAL HVLS FAN PRODUCT SPECIFICATIONS VFD PANEL T /.4.______ 12" ' SINGLE OR t3osmml�---32./ A MULTI FAN _ _ I TOUCH SCREEN :� I � PANEL 4014._ .,0,_ 7"[177 mm1 45/8" [118 mm) r .) 4 Q 0.1/- \\\ 135 mml eifZn to74"°�2 ... :%%\gl 4 1%‘‘ \t, itil f >� 29"I736 mm1 81/4- 3 4�Q . t210 mml (76 mm1 !-1��1 am- •____ ► I Enter Fan Diameter 24' ELECTRICAL SIZING CHART FAN SIZE I 8 FT-20 FT I 24 FT Input Voltage 200V-240V,1PH, 200V-240V,3PHj 360V-480V,3PH, 200V-240V,10H, 00V-240V,3PH, 360V-480V,3PH, 50/60 HZ 50/60 HZ 50/60 HZ 50/60 HZ 150/60 HZ 50/60 HZ System FLA 5A fa 230V,1PH, 2.5A fa 230V,3130, 2.5A 0460V,3PH, 6.79A fa 230V,1PH, 6.79A fa 230V,3PH, 3.4A fa 460V,3PH, b0HZ 60HZ 60HZ 60HZ 60HZ 60HZ Fuse KTKR25 KTKR15 KTKR10 KTKR25 KTKR15 KTKR10 Motor HP 1.5 HP,1.12KW I 1.5 HP,1.12 KW' 1.5 HP,1.12KW 2.0 HP,1.49K,W 2.0 HP,1.49KW 2.0 HP,1.49KW Motor Voltage 230V,60 HZ I 230V,60 HZ 460V,60 HZ 230V,60 HZ 230V,60 HZ 460V,60 HZ Motor FLA 4.0A I 4.0A 2.OA 5.43A 5.43A 2.72A MCA* 21.75A I 13.13A 7.38A 21.75A 13.13A 7.38A *MCA is the Minimum Circuit Ampacity.In accordance with NEC 430.1221A1,MCA is calculated as 125%of the rated input current of the VFD. CONSTRUCTION GENERAL COMPONENTS 1 SAFETY COMPONENTS Frame Black Powder Coat/Welded Steel Fabrication Steel Hub Plate Hub Assembly ', 6061-T6 Aluminum I able Galvanized 1/4"x 7 x 19 Steel Safety F Blade Struts(Invertible) Clear Zinc/High Tensile Steel Aircraft Grade Cable , Blades Anodized/6063-T6 Aluminum res Galvanized 1/8"x 7 x 19 Steel Guy V Aircraft Grade Cable Blade End Winglets Aluminum 3003-H14 Rotor Ret4ning Ring Zinc Plated/3/16 A569 Steel MOUNTING HARDWARE Standard Mount I Universal I-Beam Clamp w/Swivel Joint&7"Drop Laminated Wood Beam Clamp[Optionil1 Brackets Extra Wide/Thick I-Beam Mount(Optioaal) " Consult Factory Additional Drop Extensions[Optional} Up to 10 FT in 1 FT Increments ront Solns or ri c spout wringEngineered Solutions O EPIC FANS products 4F Engineered maybe the subjutio ect of se one ores morethe U.S.ghtto and/hangeor foreign ecifi,issuedcations and/andordes pendingignswith,designnotice and/or and utilityithout patents.incur 1En4 andobligations.Epic Fans4Front as wordsEngineer and logos luti are C US registered trademarks belonging to ASSA ABLOY Entrance Systems AB or other companies controlled by the same organization. OASSA ABLOY Entrance Systems.All Rights Reserved.Part of ASSA ABLOY LISTED 1612 Hutton Drive,Suite 140•Carrollton,Tx 75006,USA•Tel:866-696-2464•Fax:972-389-4224•HVLSFans©epicfan.tom•www.epicfan.com ESF-CIHVLS-1124 E506041 ,, EPIC FAIIIIS COLOSSUS INDUSTRIAL HVLS FAN PRODUCT SPECIFICATIONS Control Options Mechanical Options I] Wired Touch Screen E Mounting Extensions 3 FT/ M ❑ Wired Touch Screen with Temperature Control 0 Extra Wide Beam Plate inch wide beam ❑ Multi Fan Remote (2-6) Fans 0 Powder Coated Blades RAL Color O Slave Remote 0 Powder Coated Frame & Mount RAL Color ❑ NEMA 4X Remote Enclo ure 0 Powder Coated Winglets RAL Color O NEMA 4X VFD Enclosure 0 Corrosion Resistant Package **consult factory ❑ iFan 4.3(12 Fans Max/3 Gr ups Max) •12OVPowerRequlred I! Black Anodized BIa es 0 Silver Anodized Blades O Humidity/Temperature Sensor 0 BACnet TCP/IP ❑p Black Motor Covers 0 Silver Motor Covers ❑ iFan 7.0(24 Fans Max/4 Gr ups Max) •120VP werRequired 0 Laminated Wood Be m Brackets ❑ BACnet TCP/IP 0 H idity/Temperature Sensor ❑ Truss Span Mountin Kit(consult factory) ❑ BACnet MSTP 0 W b Server offfand crease th 7em•unt 0 Z-Purlin Mounting Ki (consult factory) O iFan 10.0(30 Fans Max/4 Groups Max) •120VPDwer Requaed Model Normal Industrial 0 BACnet TCP/IP 0 Humidity/Temperature Sensor Fan Size H nging Weight RPM Number Spacing •qn decrease the amount ❑ BACnet MSTP 0 Web Server offansonthesystem• EF08-155 8 FT 1.5 HP 14 tbs.173 kg) 55 feet 198 ❑ BMS Interface Card EF10-155 10 FT 1.5 HP 1f73 Lbs.182 kg) 60 feet 154 ❑ Modbus TCP/IP 0 BACnet TCP/IP EF12-155 12 FT 1.5 HP 11 lbs.(86 kg) 65 feet 125 ❑ BACnet MSTP ❑ Slave Remote EF14-155 14 FT 1.5 HP 1139 tbs.I86 kg) 70 feet 106 EF16-155 16 FT 1.5 HP 1 I?8 lbs.194 kg) 90 feet 92 Voltage EF18-155 18 FT 1.5 HP 206 lbs.1101 kg) 95 feet 81 ❑ 208V Single Phase 0 460-480V 3 Phase EF20-155 20 FT 1.5 HP 214 lbs.1105 kg) 100 feet 72 i 240V Single Phase 0 575V 3 Phase EF24-205 24 FT 2.0 HP 241 tbs.1107 kg) 110 feet 60 ❑ 208-240V 3 Phase Standard Blade Colors Fire Panel O Standard 0 Networked BLACK SILVER Industrial HVLS Fan Warranty: Please See Full Warranty Outline Located in the HVLS Users Manual Mechanical Etectrica� Labor Standard iFan BMS 1 I terface Accessory Remote Controls C�rd Sensors 15 Years 7 Years 1 Year 1 Year 1 Year 1 Year 1 Year 4Front Engineered Solutions reserves the right to change specifications and designs without notice and without incurrin obligations.4Front Engineered Solutions O EPIC FANS products maybe the subject of one or more U.S.and/or foreign,issued and/or pending,design and/or utility patents.Epic and Epic Fans as words and logos are C-03 us registered trademarks belonging to ASSA ABLOY Entrance Systems AB or other companies controlled by the same organization. ©ASSA ABLOY Entrance Systems.All Rights Reserved.Part of ASSA ABLOY LISTED 1612 Hutton Drive,Suite 140•Carrollton,TX 75006,USA•Tel:866-696-2464•Fax:972-389-4224•HVLSFans@epicfan.com•www.epicfan.com ESF-CIHVLS-1124 E505041 k ,.- `- -- — - -- 0 EPIC FANSCOLOSSUS INDUSTRIAL HVLS FAN AMCA CHART Fan Calculated Calculated an CFM*Tested' Voltage/Phase/ Large Diameter Stand* Electrical Input Direction Reversible? Diameter %°of Max %of Max PM to ANSI/AMCA Frequency Ceiling Fan-Ceiling Power Power[Watts]at tft) CFM RPM Standard 230i Fan Energy Index [Watts] Standard 15 HVLS• : [CFEI) Air Density 8 23% 26% 151 9,283 208 V/Single Phase 6 45 Forward Yes 43% 44% 187 17,084 208 V/Single Phase 1.81 6 110 Forward Yes 62% 63% 1125 24,614 208 V/Single Phase 6 237 Forward Yes 81% 81% 1162 32,233 208V/Single Phase 6 456 Forward Yes 100% 100% I199 39,570 208 V/Single Phase 1.26 6 778 Forward Yes 10 25% 28% 142 14,202 208 V/Single Phase 6 57 Forward Yes 43% 46% 168 24,750 j 208 V/Single Phase 1.62 6 133 Forward Yes 63% 64% 195 35,736 208 V/Single Phase 6 283 Forward Yes 81% 82% 1122 46,522 208 V/Single Phase 6 527 Forward Yes 100% 100% 1149 57,124 j 208 V/Single Phase 1.2 6 890 Forward Yes 12 22% 25% 131 17,779 208 V/Single Phase 6 44 Forward Yes 42% 44% 188 33,749 208 V/Single Phase 1.89 6 124 Forward Yes 62% 63% 178 50,068 208 V/Single Phase 6 295 Forward Yes 82% 81% [101 65,641 208 V/Single Phase 6 584 Forward Yes 100% 100% I124 80,156 208 V/Single Phase 1.28 6 1002 Forward Yes 14 23% 27% 28 23,773 208 V/Single Phase 6 51 Forward Yes 43% 45% 46 43,842 208 V/Single Phase 1.71 6 145 Forward Yes 62% 63% 65 63,794 j 208 V/Single Phase 6 335 Forward Yes 81% 82% 84 83,480 j 208 V/Single Phase 6 653 Forward Yes 100% 100% 103 102,927 208 V/Single Phase 1.22 6 1142 Forward Yes 16 18% 25% 23 23,479 208V/Single Phase 6 52 Forward Yes 40% 43% 40 50,905 208 V/Single Phase 1.64 6 148 Forward Yes 61% 62% 57 77,582 208 V/Single Phase 6 346 Forward Yes 80% 80% 74 102,461 j 208 V/Single Phase 6 687 Forward Yes 100% 100% 92 127,604 208 V/Single Phase 1.23 6 1214 Forward Yes 18 23% 27% 21 34,416 208 V/Single Phase 6 59 Forward Yes 42% 44% 34 63,414 208 V/Single Phase 1.58 6 170 Forward Yes 61% 62% 48 93,275 208 V/Single Phase 6 395 Forward Yes 81% 81% 63 123,351 208V/Single Phase 6 771 Forward Yes 100% 100% 78 151,781 i 208 V/Single Phase 1.15 6 1342 Forward Yes 20 23% 25% 18 41,327 j 208 V/Single Phase 6 52 Forward Yes 41% 43% 31 73,461 208 V/Single Phase 1.76 6 156 Forward Yes 61% 61% 44 108,969 208 V/Single Phase 6 386 Forward Yes 80% 81% 58 143,336 208 V/Single Phase 6 786 Forward Yes 100% 100% 72 179,224 208 V/Single Phase 1.14 6 1634 Forward Yes 24 21,% 25% 15 50,474 208V/Single Phase 6 60 Forward Yes 38% 44% 26 93,186 208 V/Single Phase 1.53 6 180 Forward Yes 59% 64% 38 145,476 208 V/Single Phase 6 459 Forward Yes DO% 81% 48 196,274 208 V/Single Phase 6 932 Forward Yes 100% 100% 59 245,291 208 V/Single Phase 1.14 6 1720 Forward Yes 4Front Engineered Solutions certifies that the Industrial model 8'-24'shown herein is Ucensed to bear the AMCA seaL ThIe�ratings shown are based on i'i�•• 0 the tests andprocedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certified Ratings Program. �-. tit AMCA Certified tabors seal applies at free deUvery only.Performance ratings do not included the effects of appurentances(accessories). • .21 [21 1_ hiliki.. El f 4Front Engineered Solutions reserves the right to change specifications and designs without notice and without incurrin obligations.4Front Engineered Solutions products may be the subject of one or more U.S.and/or foreign,issued and/or pending,design and/or utility patents.Epi and Epic Fans as words and logos are `+ (2, us registered trademarks belonging to ASSA ABLOY Entrance Systems AB or other companies controlled by the same organization. EPIC FANS ©ASSA ABLOY Entrance Systems.All Rights Reserved.Part of ASSA ABLOY LISTED 1612 Hutton Drive.Suite 140•Carrollton.TX 75006.USA•Tel:866-696-2464•Fax:972-389-4224•HVLSFans r©epicfan.Eom•www.epicfan.com ESF-CIHVLS-1124 E505041 t- __..... -- y TECHNICAL SPECIFICATIONS CHOP IR WE RE YOUR BIGGEST FAN CHOP20 i,. .., liEt offp , • 20" HVHS FAN ..,;.. . i� ?jr� , 1 ,•• , C-3 s. -Q I• . The Chop20 line of fans are all perfectly tuned,infinitely variable speed,and are built with the highest quality components - .� available.The new 2025 model's internal components have - , received 3rd-party independent testing indicating an expected O 20+year lifespan.The fan speed is infinitely variable,without the _: use of a VFD,so customers can fine tune exact airflow rates to I optimize human and animal comfort.3rd party energy use andmu airflow independent testing is conducted at BESS Laboratories at the University of Illinois. Ni3 r - - -. CD1 I I I I l i I I I a I '8 `r ',,, '' I tt `I, � . fir ' ` w r#I ; y rf7, i ) I a • i i •• y� P - R n" • 1 1 NbIpc., ® I I. 1 I 1 I ADJUSTABLE WALL MOUNT ADJUSTABLE CEILING MOUNT CHOPAIR CONTROLLER 1 I I CD SPECIFICATIONS 0 CFM(FREEAIR) I 6100@TOP SPEED OSCILLATING NO = CD RPM 200-1800 FIXED ORPORTABLE FIXED O MOTOR ENCLOSURE TEAO POWER(HP) 42 M IP RATING 66 NAMEPLATE AMPS 57/3.71 3.0 r--.. PHASE I 1 CFMCALCULATION ANSI/AMCA 230 99 Co SPEEDS INFINITELY VARIABLE LIFE EXPECTANCY MOTOR-20YEARS Cr) VFD REQUIRED. NO WARRANTY 3 YEARS Cr) SPEED CONTROL 0-10V SIGNAL MOUNT TYPE WALL OR CEILING -P CAD CFM/WATT(THRUST) I 247AVGIVARIABLE MOTORCOLOR WHITE OR BLACK 1 C) CORD 6'INCLUDED!NO PLUG GUARD COLOR WHITE OR BLACK CO �) VOLTAGE 120/208-230/277 APPLICATION INDUSTRIAL, c_ri GUARD MATERIAL I POWDER COATED STEEL MISTING RING COMPATIBLE GUARD SPACING I 1/2-1UL507 RATED FREQUENCY 50/60H2 BLADE MATERIAL I GLASS REINFORCED NYLON 0-10VIMPEDANCE 11,5000HMS BLADE DIAMETER 20` MFG LOCATION NEBRASKA SHIPPING WEIGHT I 29 LBS COUNTRY OF ORIGIN USA SHIPPING DIM I 24 X 24 X18 TESTING LOCATION UNIVERSITY OF ILLNOIS I LABORATORY TEST RESULTS • ;` IN CHOP IR WE RE YOUR BIGGEST FAN ' '_.,ftoix . 1 4', CH 0 P2O •, .1::i. . _ , "1 .01, ,...L.:41., , 20" HVHS FAN 'i �_ .. CD , = AIR FLOW DIAGRAM O ) 73 1 I k 3432 FPM +843 FPM 479 F M _.—----.>--_ 1 NI, I sI I I. CI:il a01 iii M Z?r4 FPM 177 FPM i .` i I I lU I ._ a { L t I 1 1 i _ i I 20' I 20' 40' 60' 80` 100' I I I 'I. I I I r LAB RESULTS UNIVERSITY OF ILLINOIS DEPARTMENT OF AGRICULTURAL AND BIOLOGICAL ENGINEERING THRUST MEASURED EFFICACY SD ➢IMPELLER THRUST AMBIENT EFFICIENCY AIRFLOW CFM) CENTERLINE POWER RPM VOLTS AMPS INPUT POWER .(THRUST (IN) THRUST(LBF) RATIO(LBF/ (THRUST VELOCITY KW/ (KW) CFMfVi) (FPM) = 10.91/ 02 502 121 1771 1<01 492 0415 .1190 101 1_10 Q I20 2 S 62 12 4 1691 1201 4 49 0 371 4020 10.8 1240 n CD II 207 397 140 15:9 1'06 343 0283 '720 112 1120 0 M I. 20 2 3 09 15 5 1362 1201 .b 0 2 3290 16..4 1060 I 00 0. 2 35 173 1193 1.0 4 178 0136 2880 211 860 CO 6O vIC, 202 136 210 873 1205 0A- 000 2100 34:9 6'0 -P CAD I 1 202 022 223 553 120 019 Ue' 889 883 180 D O_ TEST CONDITIONS: INSTRUMENTATION: T(WB):53.5 TEMPERATURE AND BAROMETRIC PRESSURE: T(DB):68.5 VAISALA INDIGO 520 POWER MEASUREMENT 1 BAROMETRIC PRESSURE,(IN.HG):29.51 PHASE:VALHALLA 2101 POWER MEASUREMENT 3 PHASE:VALHALLA 2301 TACHOMETER:NOVA PRO 100 LOAD CELL:OMEGA LC703-50 1 CENTERLINE VELOCITY:TSI VELOCICALC VANE ANEMOMETER 8324 w _ . — _..__-- i INSTALLATION INSTRUCTIONS CHOP 'ii' U�1 _ � WE RE YOUR BIGGEST FAN , 1 \Ike . 444;. cHop20 ., • „ . 20" HVHS FAN C7 , . . = INSTALLATION (STEPS 1-4: MOUNTING) 0 1 1 I 1 11.0 1 1 I � I 1 I. 1 1 1 1 1 .1 ) 1 STEP 1 s, t 1 1 1 • I 1 STEP 2 } '� 1 C=1 I I I 1.25'BRACKET TUBE 0 { 1 TO CEILING BRACKET USING � I 1 ATTACH 1°SQUARE TUBE TO � � 1 I PROVIDED FLANGE HEAD Q I I I FAN BRACKET USING - I I BOLTS AND NUTS. I I PROVIDED FLANGE HEAD " i SECURELY MOUNT BRACKET a I I I BOLTS AND NUTS. ;. - i 1 IN DESIRED LOCATION. 4 I I I ... i; I Q I I I 1 I I I I I I i I I I I I I 1 I I I I I I I I STEP 3 I I I .1- I I I I INSERT I°SQUARE TUBE 'i I I I , ATTACHED TO THE FAN INTO I I I. I THE PREVIOUSLY MOUNTED , , I 1.25"SQUARE TUBE. I I I ADJUST FAN HEIGHT STEP 4 I ENSURING AT LEAST 5°OF ,-\ 1 I j I CD I TUBE OVERLAP. p 1. I I ENSURE ALL HARDWARE IS I _ 1 INSTALL FLANGE HEAD BOLTS � t 1 1 TIGHT PRIOR TO CONNECTING 1 0 1 AND NUTS TO SECURE FAN IN `� I I 1 TO ELECTRICITY. I -� , PLACE ADJUST FAN ANGLE AS ;,no I I I n , DESIRED BY LOOSENING -Q , , 1 I I FLANGE HEAD BOLT IN THE . 9{ , , I HALF MOON SLOT ON THE FAN. I „'ENSURE ALL HARDWARE IS Nib., I I I n. 1 TIGHT PRIOR TO CONNECTING I I ! 1 I TO ELECTRICITY"' I I I I I I I I I I I — i CO I I Cr). I I � i 1 I a, i 1 I I I 1 �) 1 1 W 1 STEP 5 1 01 WIRING-SEE NEXT PAGE. I I 1 1 I I I I I I • I I I I I I r-. ----..._-- ._. .....� _ ..__—T.�------ - . ----- -- - - +...�, INSTALLATION INSTRUCTIONS !l4rfi ` • CHOP � N\N WE RE Y cHop20 GUR BIGGEST FAN, .,, 'l ,, 1 20" HVHS FAN c.D , , INSTALLATION (STEP 5: WIRING) ! I =0 I ,I3 CI-i0PAIR STRONGLY RECOMMENDS THE USE OF A LICENSED ELECTRICIAN FOR THE INSTALLATION OF ALL CHOPAIR , N)' ' PRODUCTS.IMPROPER INSTALLATION VOIDS ALL PRODUCT W RRANTIES AND ABSOLVES CHOPAIR FROM DAMAGES OR O INJURIES THAT MAY OCCUR AS A RESULT. I I I • r r -- - POWER:L1 j 1 I ' ll POWER:NEUTRAL 1 POWER:GROUND I l 4.... .iiii N - _, ' 1 C7 LOW VOLTAGE+:0-10V ' = 1 1 O. • 6 LOW VOLTAGE-:0-10V j ' n I ' *DAISY CHAIN/T CONNECT UP TO 20 FANS I , TOGETHER PER GROUP FOR MULTIPLE FAN I , •n *NOTE,CHOP20 FANS ONLY OPERATE ON SPEED CONTROL , 120V POWER SO THEY DO NOT HAVE RED 1 M ' LEADS TO CONNECT OR DISCONNECT. — 1 208-277V OPERATION I SAFE TO OPERATE ON ZANY VOLTAGE ,. Co FROM 120-277V. RED LEADS DISCONNECTED FOR 208+V i, 1 6) 120V OPERATION ' Cr) ' -P ' RED LEADS CONNECTED FOR 120V I i I I CA). I I �. 1� LIQUID TIGHT FITTINGS SHOULD BE USED ON ALL CONDUIT AND JUNCTION BOXE� I' UI TO MAINTAIN ALL BVS'RODUCTS'IP66 SEAL RATING. I ' 1 i i 1 ' --- - -. -.--- -- -.-.--- -.=------- ......____ ___. _ ,_.. _ -, INSTALLATION INSTRUCT ONS = CHOP IR r ;5$ ���!}�y, WE RE YOUR BIGGEST FAN 1.,q) CHOP20 ‘4, FAN 20" HVHS OPERATION CD ONCE FANS ARE SECURELY INSTALLED,AND WIRING HAS BEEN PROPERLY CONNECTED,CONSTANT HIGH VOLTAGE SIf IOULD BE SUPPLIED TO THE FANS.THE FANS WILL NOT RUN,OR CONSUME ANY ENERGY,UNTIL A 0-10V SIGNAL IS PROVIDED. ' 11 ) **0-10V LOW VOLTAGE WI ES CAN BE DAISY CHAINED/T CONNECTED,TO CONTROL I O GROUPS OF UP TO 20 FANS AT ONCE.CONNECTING MORE THAN 20 FANS CAN RESULT ' IN LINE LOSS AND VARIATI NS IN FAN SPEED WITHIN THE GROUP. ' 0-10V SIGNAL CAN BE PR VIDED BY ENVIRONMENTAL CONTROLLER OR BY CHOPAIR'S MULTIFAN CONTROLLER. I I VOLTAGE TO START VARIES BY MODEL BUT MOST WILL BEGIN RUNNING ONCE ' SUPPLIED WITH 1.5+V. I AS ADDITIONAL VOLTAGE IS SUPPLIED,FAN SPEED WILL INCREASE UNTIL A MAXIMUM IS REACHED AT 10V. ' NOTE,THE INTERNAL CO TROLS OF ALL B S FANS CAN SAFELY ACCEPT UP TO 13V. I ANY VOLTAGE HIGHER TH N 13V WILL DAMAGE INTERNAL CONTROLS AND VOID ALL WARRANTIES. ' I ' I. I. MAINTENANCE OCCASIONAL CLEANING IS THE ONLY MAINTENANCE REQUIRED.ALL FAN AND MOUNT COMPONENTS ARE DESIGN ED TO LAST 20 YEARS IN THE FIELD WITH PROPER I n CLEANING. LIKE ALL FANS,THE CHOP IR LINE OF FAN PERFORM THEIR BEST WHEN CLEAN.FANS WILL COLLECT DUST ANDIDEBRIS AT DIFFERENT RATES DEPENDING ON THE ENVIRONMENT THEY ARE LACED.IF YOU NOTICE THEY ARE DIRTY,SIMPLY SPRAY ' CO THEM OFF WITH WATER TO REMOVE DIRT AND DEBRIS.THE FRONT COVER CAN BE REMOVED,IF NECESSARY,IBY CUTTING THE SINGLE ZIP TIE.REINSTALL THE FRONT AND � v COVER AFTER CLEANING INSTALL A NEW ZIP TIE TO SECURE THE COVER. THE CHOPAIR LINE OF FADS ARE DESIGNEE,TO TAKE SOME ABUSE.HOWEVER,IF W REPAIRS BECOME NECESS RY DUE TO AN ACCIDENT,THEY ARE 100%SERVICEABLE. , CA I ' - ' EMAIL BOBBY@CHOPAI .COM OR CALL 816)643-3875 FOR ANY NEEDEDCrI ' v REPLACEMENT PARTS. I ' CALL DAVE FOR TECHNICAL ASSISTANCE AT(402)534-2015-EXT 100 OR AFTER HOURS AT(402)366-1913. I ' i INSTALLATION INSTRUCTIONS i CH�� I� - F i WE RE YOUR' UIGGEST FAN CONTROLLERI _ .........,.„0„..,_ ,:„." ,....,,,, ,,,,. ADJUSTABLE SPEED MULTI-FAN ,.. .. . ., . .R-, ^.. • n . = INSTALLATION THE USINGOTHE ENCLOSED ED WPPCOACCKI MOUNTED TO MOST SURFACES 0 t 'CI� STEP 2 � I I I t I, I I CONNECT BLUE LOW VOLTAGE I 14444:1 I STEP 1 I I POSITIVE FAN WIRES TO I I I CORRESPONDING BLUE LOW 7,,, ;'. I I I VOLTAGE TERMINALS ON BASE i CM BEFORE OR AFTER MOUNTING- I i PLATE. I � ' I REMOVE FRONT '1 '. t I REMOVING 4 ACORN NUTS I 1 CONNECT BLACK LOW VOLTAGE . I I LOCATED IN EACH CORNER OF I I NEGATIVE FAN WIRES TO I THE FRONT PLATE. I I CORRESPONDING BLACK LOW { I I I I VOLTAGE TERMINALS. I I PENETRATE THE BOX IN DESIRED I I -- �'` I I LOCATIONS TO CONNECT TO I 1 'LOW VOLTAGE WIRES MAY BE IA. T ._ ,.,_,_t'_•Y ; I 120V AC POWER CORD AND LOW i DAISY CHAINED FOR UP TO 20 I 1 VOLTAGE FAN WIRES. FANS PER GROUP A OR GROUP B. ' II' 1 I DO NOT EXCEED 40 FANS TOTAL 1 I I I PER CONTROLLER. I I I I I I I REPLACE FRONT COVER. I I I I I I I I I I I I I I 'I .1 I I I I OPERATION r I i SPECIFICATIONS i` ] I • TURN ON THE TOGGLE SWITCH 1 I I 'IP66SFAIFD-SUITABLEFOR I I ON THE FRONT PLATE FOR THE .j 1 I OUTDOOR USE 1 n I CORRESPONDINGAREA/GROUP, ... ..�q POWER INPUT-PLUGSINTO I _ y 1 I STANDARD 120V WALL OUTLET 1 ADJUST FAN SPEED UP OR ' -- ', I 1 UL*POWER OUT-0-12VMULTI I C t DOWN USING SILVER DIAL THE I I CHANNEL(LOW VOLTAGE TO FAN 1 I DIAL MUST BE SET TO THE !1/41.11 �$' I I CONTROU 1n.1 MINIMUM SPEED OF2.5TOTURN q'- :,._._' I I *DESIGNED,ENGINEERED,AND I I THE FANS ON. • �- ^ . I I ASSEMBLED IN THE USA I = 1 1 1 1 • 1 I i I C. I I I .1 0. I I I I 00 C C, -It. GJ cz 00 y cii I 1