HomeMy WebLinkAboutP.R. 25216 CONTRACT WITH HYDROMAX USA FOR THE VALVE ASSESSMENT AND ASSET MANAGEMENT SERVICES.I
(itt n/
nrt rtltu� �
INTEROFFICE MEMORANDUM
Date: October 14, 2024
To: The Honorable Mayor and City Council
Through: Ronald Burton, C.P.M., City Manager
From: Calvin Matthews, P.E., Water Utilities Director
RE: PR No. 25216 - Execute contract with Hydromax USA for the Valve Assessment
and Asset Management Services.
Introduction:
This Agenda Item intends to seek the City Council's approval for executing a contract with
Hydromax USA of Coppell, Texas. The contract provides for valve assessment and asset
management services through TIPS Contract No. 240501 in the total amount of$437,105.80.
Background:
The City of Port Arthur requires reliable information regarding the location, condition, and
operability of water distribution valves to support routine operations, repairs, emergency
response, and asset-management planning. Hydromax USA of Coppell, Texas has submitted a
proposal for valve assessment and asset management through TIPS Contract No. 240501 in the
total amount of$437,105.80. The scope of services includes City-directed valve assessment,
valve exercising, condition documentation, and GPS data collection at the applicable TIPS
contract unit price.
Budget Impact:
The total projected budgetary impact is$437,105.80. Funds are available from CIP Account No.
405-40-000-8516-00-00-000 Project No. WS0037.PJD.
Recommendation:
It is recommended that the City Council approve PR No. 25216, to execute a contract with
Hydromax USA, as discussed/outlined above.
"Remember,we are here to serve the Citizens of Port Arthur"
IF
PR No. 25216
10/14/2026 cm
Page 1 of 3
RESOLUTION NO.
A RESOLUTION AUTHORIZING THE CITY MANAGER TO EXECUTE
A CONTRACT WITH HYDROMAX USA OF COPPELL, TEXAS,
THROUGH TIPS CONTRACT NO. 240501, FOR THE VALVE
ASSESSMENT AND VALVE ASSET MANAGEMENT FOR THE WATER
UTLITIES DEPARTMENT WITH A TOTAL BUDGETARY IMPACT OF
$437,105.80, WITH FUNDING ALLOCATED FROM WATER UTILITES
CIP ACCOUNT NO. 410-40-000-8516-00-00-000, PROJECT NO.
WS0037.PJD.
WHEREAS, the City of Port Arthur requires reliable information regarding the location,
condition, and operability of water distribution valves to support routine operations, repairs,
emergency response, and asset-management planning; and,
WHEREAS, Chapter 271 of the Texas Government Code allows a city, by resolution of
its governing body, to participate in cooperative purchasing programs, such as The Interlocal
Purchasing System(TIPS), as an alternative to formal bid process; and,
WHEREAS, pursuant to Resolution No. 12-008, the City of Port Arthur entered into an
interlocal agreement for cooperative purchasing with TIPS Cooperative Purchasing Program;and,
WHEREAS, Hydromax USA of Coppell, Texas has submitted a proposal, through TIPS
Contract No. 240501 (Exhibit"A"), for valve assessment and valve asset management in the total
amount of$437,105.80; and,
WHEREAS, the proposed services include City-directed valve assessment, valve
exercising, condition documentation, and GPS data collection services at the applicable TIPS
contract unit prices; and,
WHEREAS, the City Council finds the approval of the agreement in the public interest
and supports the efficient operation and maintenance of the City's water utility system.
NOW THEREFORE,BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY
OF PORT ARTHUR, TEXAS:
THAT,the facts and recitals in the preamble are true and correct; and,
PR No. 25216
10/14/2026 cm
Page 2 of 3
THAT, the City Manager of City of Port Arthur is hereby authorized and directed to
execute, in substantially the same form, a one-year contract with Hydromax USA of Coppell,
Texas (Exhibit "A") for the unit prices shown in the proposal, with a total budgetary impact of
$437,105.80, for the same prices as shown in the contract and bid; and,
THAT, the total budgetary impact of$437,105.80 is available in CIP Account No. 410-
40-000-8516-00-00-000, Project No. WS0037.PJD; and,
THAT, a copy of the caption of this resolution be spread upon the minutes of the City
Council.
READ, ADOPTED, AND APPROVED THIS day of
2026 at a Regular Meeting of the City Council of the City of Port Arthur, Texas, by the following
vote: AYES: Mayor
Councilmembers:
NOES:
Charlotte M. Moses
Mayor
ATTEST:
Christe Whitley Ned, TRMC
City Secretary
PR No. 25216
10/14/2026 cm
Page 4 of 4
APPROVED AS TO FORM:
Roxann Pais Cotroneo
City Attorney
APPROVED FOR ADMINISTRATION:
1114)/
Ronald u .on,
City Manager
Suhail Kanwar, P.E.
Director of Public Services
Calvi Matthews, .E.
Water Utilities Director
APPROVED AS TO THE AVAILABILITY
OF FUNDS:
(126
r. L nda(Lyn) o well, ICMA-CM, CGFO
Finance Director
Cmtpk_. 112,dete
Clifton E. Williams Jr. CPPB
Purchasing Manager
Exhibit "A"
Contract with Proposal
CONSTRUCTION CONTRACT
AGREEMENT
[Non-Federally Funded Projects]
THIS AGREEMENT, made this day of 2026a by and between the CITY OF PORT
ARTHUR, a municipal corporation organized under the laws of the State of Texas, hereinafter
called "OWNER", and HYDROMAX USA hereinafter called "CONTRACTOR".
WITNESSETH: That for and in consideration of the payments, terms, conditions, and
agreements set forth herein, OWNER and CONTRACTOR agree as follows:
1. The CONTRACTOR will commence and complete the construction of HYDROMAX USA.
2. The CONTRACTOR will furnish at his own expense all the materials, supplies, tools,
equipment, labor, and other services necessary for the construction and completion of the
Project described herein.
3. The CONTRACTOR will commence the work required by the Contract Documents on or
before a date and will complete the same within consecutive calendar days.
4. The CONTRACTOR agrees to perform all the Work described in the Contract Documents and
comply with the terms therein for the estimated total amount of $437,105.80,as shown
in the Service Proposal.
5. Work, following the Contract dated after the Notice to proceed, the Contractor shall
complete the WORK within 365 consecutive calendar days.
6. The term "CONTRACT DOCUMENTS" means and includes the following:
y AGREEMENT
➢ PROPOSAL
v NOTICE TO PROCEED
6. The OWNER will pay to the CONTRACTOR in the manner and at such times as outlined in
the General Conditions such amounts as required by the Contract Documents.
7. This Agreement shall be binding upon all parties hereto and their respective heirs,
executors,administrators,successors,and assigns.
Page 1 of 2
CONSTRUCTION CONTRACT
AGREEMENT
[Non-Federally Funded Projects]
IN WITNESS WHEREOF, the Parties hereto have executed, or caused to be executed by their
duly authorized officials,this Agreement in two (2) copies, each of which shall be deemed an
original on the date first above written.
APPROVED IN FORM: OWNER:
CONTRACTOR: OWNER:
HYDROMAX USA CITY OF PORT ARTHUR
BY By
NAME NAME
ADDRESS
TITLE
Page 2 of 2
HYDROMAX USA
. 1
. \ %
...,
40 -101
_ elo
4, „A
1 11A1111 i 4111t
• : --, Ai,. 41.44 1. ,.., ,,,,
..._
.„.
-....,
.
. .„..
, —
, •
' 0
1101F411111k e ...1", lin 111. $
. 41
011040 0'111.0 ONO ',:::
O., I
,..... ',, ,..;
City of Port Arthur, Tx ., . .... ,
... ..
Budgetary Proposal for:
Water & Wastewater Asset Management Services .... „
TIPS Cooperative Purchasing Contract#240501
.., .. . .:...,,...
. . . ..... .
._. .
.,., ..
... .
MRO (Maintenance, Repair, and Operations of Facilities and Grounds)Supplies, ,., ... ....„..,
Equipment,Tool Rental,Sales and Services
. . . ,..
....' .•L. -, ' '
Submitted by: -..-- .. .. .
Miles Sommers - -1T4r,..--
'tAzioAlff, Oh
Hydromax USA z. ---,,.!...il. ...,., ,
7:4‘.4411t1.37:. -t).-- !...z.
750 Canyon Drive,Suite 230 i- • i
Coppell,TX 75019 11
.....4., .
i ..
,ji .__ 4,
.... ,
.......„,,,,... ...,„ 4 t
•114PARI 4' ...
1 I
9 . - , t
* , I,
1 i \ I if
4. ,w , .
- .
.. .
' ....
' -
Ile .;...
- '
-- ...,
..--- :
• -.
. .
HydromaxUSA.com
' 1
P .
understand the present I protect the future
THE
October 5,2026
TIPS INTERLOCAL
� x �
PURCHASING
SYSTEM
Jess Liao
Utility Assistant Director AWARDED VENDOR
City of Port Arthur
444 4th St
Port Arthur,Tx 77640
RE:TIPS Contract 240501/Asset Management
Dear Jess,
On behalf of Hydromax USA, I am pleased to submit this budgetary proposal for asset management services using TIPS Contract
240501 MRO Supplies, Equipment,Tool Rental, Sales and Services. Given the excellent qualifications of our team and personnel,
extensive experience and expertise with similar maintenance services programs, and strong regional presence, Hydromax USA is
uniquely qualified and well-positioned to help the City of Port Arthur develop and implement this program.
Established in 2003, Hydromax USA's team of world-class professionals and innovative solutions enable water and wastewater
utilities to accelerate operational excellence, promote the continuity of critical infrastructure, protect the communities they serve,
and invest funding where it matters most. HUSA has additional capabilities in the areas of non-intrusive/non-destructive pipeline
condition assessment, leak detection, sanitary sewer evaluation surveys and multi-sensor inspections to give our clients a full and
accurate picture of its buried infrastructure.Simply put,we help communities thrive!
Our crews have assessed more than 2 million valves,tested, and maintained over 750,000 fire hydrants, and collected 95 million
data points working for water and wastewater utility clients like Houston Water, Nashville Metro Water Services, Orange County
Utilities, and others. Based upon a robust record of performance, our clients recognize that Hydromax USA brings an exceptional
ability to meet their needs for advanced data collection and they select us again and again.
As an ESRI Silver Partner,we have 70+full-time GIS professionals in our data center that specialize in client information management,
condition assessment program analytics, and customer reporting.Our proven processes and best practices in the areas of progress
reporting, risk management and quality assurance help us to plan for and deliver projects on time and within budget.
Should you have any questions regarding the enclosed proposal, please do not hesitate to contact me directly at(817)946-6551 or
Miles.Sommers@hydromaxusa.com. Thank you again for your time and consideration.
Respectfully,
e /</OF:'1
Miles Sommers
Business Development Manager
HydromaxUSA.com 1
understand the present I protect the future
1.0 ADMINISTRATION&TRAVEL
1.0.A Crew Travel/Mobilization
Hydromax USA will charge the Owner for crew travel and mobilization to the project site using a single line item for each crew
member per 8-hour travel day.
1.0.B Lodging and Per Diem
For non-local projects, Hydromax USA will charge the Owner for crew lodging and per diem using a single line item for each crew
member per project workday.
2.0 VALVE ASSESSMENT,MAINTENANCE&INFORMATION MANAGEMENT
2.0.A-Q Valve Operation and Evaluation(Under 4 inches to over 60 inches,including Blow-Off Valves)
Hydromax USA will perform the following services for valves of various sizes in accordance with AWWA Manual M44: Distribution
Valves:Selection, Installation, Field Testing,And Maintenance.
• Locate the valve
• Identify the valve
• GPS the valve location(sub-foot)
• Clean out valve box/vault
• Visually inspect the valve to discover discrepancies that are readily visible from above ground
• Exercise the valve
• All 4"and smaller valves will be exercised manually(one person on a hand key).
• 6"to 10"valves will be exercised manually or with an electric or hydraulic valve exerciser with torque control and automated
turn counter.
• Valves equal to or larger than 12"will be exercised with a hydraulic operated, microprocessor-and torque-controlled valve
exerciser capable of 1,500 ft-lbs of torque.
• Data will be collected utilizing a handheld GPS device capable of providing consistent sub-foot point coordinates.
• Service provider will immediately notify Owner of any valves found closed or broken,or if any unsafe conditions are observed.
• Service provider will provide detailed, written valve exercising processes that will be used by its operating crews that will
include torque limits for every valve type and size anticipated in the scope of this program.
• If the valve fails to cycle at the torque limit,the exercise process will stop immediately.Additional torque may be applied to
the valve,as directed by Owner(with input from the service provider until the valve turns or the operation is suspended again
at a higher torque).
• The bypass valve will be exercised first(if present). If the bypass valve does not operate,the main valve will be exercised to a
%shut position to insure it does not become hydraulically locked in the closed position.
• Mark the valve location with blue marking paint
• Hydromax USA's Instant Notification System will be used to provide alerts for all inoperable or found closed valves. Hydromax
USA's system will be capable of providing simultaneous alerts for up to 10 TIPS Member points of contact.
• Data shall be delivered monthly to the TIPS Member in an ArcGIS compliant format.
2.0.R Valve Cannot Be Located(CNL)
If after searching for fifteen (15) minutes using Owner-provided GPS locations and/or field maps, and the valve is unable to be
found, Hydromax USA will list the valve as CNL(cannot locate). Hydromax USA will provide a separate unit price for CNL valves. If
the CNL valve is located, Hydromax USA will assess the valve and charge the appropriate unit rate for that item.
HydromaxUSA.com 2
understand the present I protect the future
2.0.5 Valve Cannot Be Accessed(CNA)
If after searching for fifteen(15)minutes using Owner-provided GPS locations and/or field maps,and the valve is located but cannot
be accessed for any reason,the Hydromax USA will list the valve as CNA(cannot access). If the CNA valve can be accessed later,
Hydromax USA will assess the valve and charge the appropriate unit rate for that item.
2.0.T Valve Located and Accessed,Not Operated(CNO)
Hydromax USA will locate,create access,obtain a GPS point, and collect information on the valve asset, however at the direction
of the utility,will not operate the valve asset. Hydromax USA will identify these assets as GPS Only. Hydromax USA will provide a
separate unit price for GPS Only valves.
Minor Valve Repairs
Under this program, the service provider will complete minor repairs as they are encountered throughout this program. Minor
repairs are defined as repairs which can return a valve to full operability and do not require backhoe excavation or breaking the
pressure barrier of the water system. While many different repairs may be necessary to restore valves to full operability,the minor
repairs noted in the pricing table will typically be completed by the service provider in a full valve assessment program.
• 2.0.0 Raise valve box to grade up to 18 inches in grass,dirt,and gravel. Hydromax USA shall provide labor to raise a valve
box up to 18 inches to the finished grade in non-asphalt areas using drop-in risers. Materials will be provided by Owner.
• 2.0.V Raise valve box to grade up to 18 inches in asphalt with cold patch. Hydromax USA shall provide labor to raise a valve
box up to 18 inches to the finished grade in asphalt areas using drop-in risers. Cold patch will be used to repair asphalt as
needed. Materials will be provided by Owner.
• 2.0.W Realign valve box in grass,dirt,and gravel. Hydromax USA shall provide labor to realign valve box vertically from a
maximum depth of up to 18 inches in non-asphalt areas. Materials will be provided by Owner.
• 2.0.X Realign valve box in asphalt with cold patch. Hydromax USA shall provide labor to realign valve box vertically from a
maximum depth of up to 18 inches in asphalt. Cold patch will be used to repair asphalt as needed. Materials will be provided
by Owner.
• 2.0.Y Operating nut replacement without excavation. Hydromax USA shall replace valve operating nut without. Hydromax
USA shall remove any existing operation nut pieces from the valve stem and lower section of the roadway box, removing
existing operating nut screws, re-tap the stem (if necessary)and securely install an operating nut. Materials will be provided
by Hydromax USA.
2.0.Z Air Release Valve(ARV)Assessment
The purpose of this maintenance is to ensure proper valve operation, prevent system air blockages,and extend equipment life:
• Visually inspect each ARV for structural integrity, leaks,and signs of corrosion or damage.
• Confirm valve accessibility and verify correct installation orientation.
• Cycle valves(where applicable)to verify proper air release and vacuum break functionality.
• Remove debris,sediment,and blockages from valve internals and surrounding appurtenances.
• Flush the valve as needed to ensure clear air passage.
• Inspect, lubricate moving parts,and replace worn components during initial assessment such as seals,floats,or gaskets, if
applicable. (materials provided in advance by utility)
• Record valve condition,operational status,GPS location,and any maintenance performed.
• Provide report with recommendations for repair or replacement,if needed.
• All work will be conducted in accordance with OEM specifications,industry standards,and safety protocols.
HydromaxUSA.com 3
understand the present I protect the future
3.0 FIRE HYDRANT ASSESSMENT,MAINTENANCE&INFORMATION MANAGEMENT
3.0.A Single Hydrant Testing and Maintenance
Hydromax USA will perform the following services in accordance with AWWA M-17 Manual for Fire Hydrants: Installation, Field
Testing,And Maintenance:
• Locate and access each fire hydrant
• Locate access and exercise fire hydrant isolation valve
• Check fire hydrant nozzle height for correct ground clearance
• Identify make, model,nozzle size and year of hydrant manufacture
• Lubricate operating nut(if appropriate for hydrant make/model)and all nozzle outlets with noncorrosive FDA approved
lubricant
• Open hydrant with nozzle caps in place to check for seal leakage
• Verify that hydrant main(bottom)valve completely closes
• Flow hydrant to maximum rate, record working pressure and calculate flow rate and gallons flushed.
• The use of a calibrated combination pitot gauge and hydrant diffuser is required for all hydrant flushing.
• Close hydrant completely. Back off the operating nut enough to take the pressure off the packing.
• Remove all outlet nozzle caps,clean the threads,check the condition of the gaskets replace as required,and lubricate the
threads.Check the ease of operation of each cap.
• Check outlet nozzle chains for free action on each cap. If the chains bind,open the loop end around the cap until they move
freely.
• Record static pressure
• Re-attach hydrant nozzle caps
• Obtain and record GPS site coordinates of hydrant.
• Document any operational deficiencies and/or miscellaneous findings.
• Hydromax USA's Instant Notification System will be used to provide alerts for all inoperable or low flow hydrants. Hydromax
USA's system will be capable of providing simultaneous alerts for up to 10 TIPS Member points of contact.
• Data shall be delivered monthly to the TIPS Member in an ArcGIS compliant format.
3.0.B. Scope 3.0A above with one-color paint: Scrape, wire brush, and paint hydrant single color. The paint shall be Sherwin-
Williams or approved equal.Coating shall be spray applied to a minimum of a 4 ml dry coat thickness.
3.0.C.Scope 3.0A above with two-color NFPA paint:Scrape,wire brush,paint hydrant two colors per NFPA flow testing color chart.
The paint shall be Sherwin-Williams or approved equal.Coating shall be spray applied to a minimum of a 4 ml dry coat thickness.
3.0.D Two-Hydrant Fire Flow Testing and Maintenance
Hydromax USA will perform maintenance procedures in accordance with AWWA M-17 Manual for Fire Hydrants:Installation, Field
Testing,And Maintenance.Testing under this section will include obtaining the residual pressure from only one"flow hydrant" or
port and will not guarantee achievement of a 10 psi drop as denoted in AWWA M17 or 25% psi drop as denoted in NFPA 291.
Prior to the execution of any Two Hydrant fire flow testing Hydromax USA will develop a digital pairing of hydrants represented in
a standalone GIS layer for submittal and review to the Owner. Digital pairing layer will be visible to field crews during the execution
of the hydrant flow test.
• Locate and access each fire hydrant
• Locate access and exercise fire hydrant isolation valve
• Check fire hydrant nozzle height for correct ground clearance
• Identify make, model, nozzle size and year of hydrant manufacture
HydromaxUSA.com 4
understand the present I protect the future
• Lubricate operating nut(if appropriate for hydrant make/model)and all nozzle outlets with noncorrosive FDA approved
lubricant
• Open hydrant with nozzle caps in place to check for seal leakage
• Verify that hydrant main(bottom)valve completely closes
• Flow hydrant to maximum rate up to 15 minutes or until clear,whichever is less, record working pressure and calculate flow
rate and gallons flushed. If hydrant fails to flow clear in the initial 15-minute flush,contact the TIPS Member.
• Close hydrant completely. Back off the operating nut enough to take the pressure off the packing.
• Remove all outlet nozzle caps,clean the threads,check the condition of the gaskets replace as required,and lubricate the
threads.Check the ease of operation of each cap.
• Check outlet nozzle chains for free action on each cap. If the chains bind,open the loop end around the cap until they move
freely.
• Record static pressure
• Re-attach hydrant nozzle caps
• Inspections will be conducted on adjacent hydrant pairs to facilitate the 2-hydrant fire flow test procedure.
• When the first hydrant is flowed,the second hydrant becomes the M-17"test hydrant"for measurement of residual
pressure drawdown in the system.
• Hydrant inspection pairs will always be chosen to maintain the test hydrant on the upstream side of the system water feed
such as on single feed mains.
• Obtain and record GPS site coordinates of hydrant.
• Document any operational deficiencies and/or miscellaneous findings.
• Hydromax USA's Instant Notification System will be used to provide alerts for all inoperable or low flow hydrants. Hydromax
USA's system will be capable of providing simultaneous alerts for up to 10 TIPS Member points of contact.
• Document all pertinent data into an electronic spreadsheet or database including the following:
o Hydrant ID tag number
o Hydrant address location
o Hydrant GPS site coordinates
o Date of flush or service
o Hydrant brand
o Hydrant model number
o Hydrant year
o Hydrant size
o Hydrant flow rate obtained
o Hydrant static and residual pressures
o Flow at 20 PSI calculation
o Hydrant pressure after 2 minutes of flushing
o Total gallons flushed during service
o Degree of operating difficulty
o Deficiencies and/or repairs required to be immediately reported to the Utility.
• Data shall be delivered to the TIPS Member in an electronic format compatible with ArcGIS/ArcMap system or SQL database.
3.0.E.Scope 3.0D above with one-color paint:Scrape,wire brush, and paint hydrant single color.The paint shall be Sherwin-
Williams or approved equal.Coating shall be spray applied to a minimum of a 4 ml dry coat thickness.
3.0.F.Scope 3.0A above with two-color NFPA paint:Scrape,wire brush, paint hydrant two colors per NFPA flow testing color
chart.The paint shall be Sherwin-Williams or approved equal.Coating shall be spray applied to a minimum of a 4 ml dry coat
thickness
HydromaxUSA.com 5
understand the present I protect the future
3.0G M17 Hydrant Fire Flow Testing and Maintenance
Hydromax USA will perform maintenance procedures in accordance with AWWA M-17 Manual for Fire Hydrants:Installation, Field
Testing,And Maintenance.Testing under this section will include obtaining residual pressure with an effort to achieve a 10 psi drop
as denoted in AWWA M17 using multiple flow hydrant ports or one additional flow hydrant(this procedure is not targeting a 25%
psi drop as denoted in NFPA 291).
Prior to the execution of any fire hydrant fire flow testing maintenance, Hydromax USA will develop a digital pairing of hydrants
represented in a standalone GIS layer to the Owner for submittal and review. This digital pairing layer will be visible to field crews
during the execution of the hydrant flow test.
• Locate and access each fire hydrant
• Locate access and exercise fire hydrant isolation valve
• Check fire hydrant nozzle height for correct ground clearance
• Identify make, model,nozzle size and year of hydrant manufacture
• Lubricate operating nut (if appropriate for hydrant make/model) and all nozzle outlets with noncorrosive FDA approved
lubricant
• Open hydrant with nozzle caps in place to check for seal leakage
• Verify that hydrant main(bottom)valve completely closes
• Flow hydrant to maximum rate up to 15 minutes or until clear, whichever is less, record working pressure and calculate flow
rate and gallons flushed. If hydrant fails to flow clear in the initial 15-minute flush,contact the TIPS Member.
• Close hydrant completely. Back off the operating nut enough to take the pressure off the packing.
• Remove all outlet nozzle caps, clean the threads, check the condition of the gaskets replace as required, and lubricate the
threads.Check the ease of operation of each cap.
• Check outlet nozzle chains for free action on each cap. If the chains bind, open the loop end around the cap until they move
freely.
• Record static pressure
• Re-attach hydrant nozzle caps
• Inspections will be conducted on adjacent hydrant pairs to facilitate the hydrant fire flow test procedure.
• When the first hydrant is flowed, the second or "paired" hydrant becomes the M-17 "test hydrant" for measurement of
residual pressure drawdown in the system, potentially using multiple ports on the flow hydrant or up to one additional flow
hydrant.
• Hydrant inspection pairs will always be chosen to maintain the test hydrant on the upstream side of the system water feed
such as on single feed mains.
• Obtain and record GPS site coordinates of hydrant.
• Document any operational deficiencies and/or miscellaneous findings.
• Hydromax USA's Instant Notification System will be used to provide alerts for all inoperable or low flow hydrants. Hydromax
USA's system will be capable of providing simultaneous alerts for up to 10 TIPS Member points of contact.
• Document all pertinent data into an electronic spreadsheet or database including the following:
o Hydrant ID tag number
o Hydrant address location
o Hydrant GPS site coordinates
o Date of flush or service
o Hydrant brand
o Hydrant model number
o Hydrant year
o Hydrant size
o Hydrant flow rate obtained
HydromaxUSA.com 6
understand the present I protect the future
o Hydrant static and residual pressures
o Flow at 20 PSI calculation
o Hydrant pressure after 2 minutes of flushing
o Total gallons flushed during service
o Degree of operating difficulty
o Deficiencies and/or repairs required to be immediately reported to the Owner.
• Data shall be delivered to the TIPS Member in an electronic format compatible with ArcGIS/ArcMap system or SQL database.
3.0.H.Scope 3.0G above with one-color paint:Scrape,wire brush,and paint hydrant single color.The paint shall be Sherwin-
Williams or approved equal.Coating shall be spray applied to a minimum of a 4 ml dry coat thickness.
3.0.1.Scope 3.0G above with two-color NFPA paint:Scrape,wire brush, paint hydrant two colors per NFPA flow testing color
chart.The paint shall be Sherwin-Williams or approved equal.Coating shall be spray applied to a minimum of a 4 ml dry coat
th
ickness.
3.0.J High Pressure Hydrant Additional Safety Procedures
When a hydrant over 125P51 static pressure is encountered, Hydromax USA will perform the following additional safety procedures
to complete hydrant testing,
• Upon obtaining working pressure, if determined to be over 125 psi,work will halt to complete the following steps.
• Check/tighten hold down bolts at flange.
• Install Hose Monster to hydrant and secure the other end to hitch mounted diffuser or another stationary anchor.
• Proceed with flowing per the above specifications.
• Upon completion check/tighten hold down bolts at flange.
3.0.K.Scope 3.0J above with one-color paint:Scrape,wire brush, and paint hydrant single color.The paint shall be Sherwin-
Williams or approved equal.Coating shall be spray applied to a minimum of a 4 ml dry coat thickness.
3.0.L Scope 3.01 above with two-color NFPA paint:Scrape,wire brush, paint hydrant two colors per NFPA flow testing color chart.
The paint shall be Sherwin-Williams or approved equal.Coating shall be spray applied to a minimum of a 4 ml dry coat thickness.
3.0.M Fire Hydrant Cannot Be Located(CNL)
If after searching for fifteen(15) minutes using Owner-provided GPS locations and/or field maps, and the hydrant is unable to be
found, Hydromax USA will list the hydrant as CNL (cannot locate). Hydromax USA will provide a separate unit price for CNL
hydrants. If the CNL hydrant is located, Hydromax USA will assess the hydrant and charge the appropriate unit rate for that item.
3.0.N Fire Hydrant Cannot Be Accessed(CNA)
If after searching for fifteen (15) minutes using Owner-provided GPS locations and/or field maps, and the hydrant is located but
cannot be accessed for any reason, the Hydromax USA will list the hydrant as CNA (cannot access). If the CNA hydrant can be
accessed later, Hydromax USA will assess the hydrant and charge the appropriate unit rate for that item.
3.0.0 Fire Hydrant Out of Service(005)
If, during fire hydrant testing and maintenance, Hydromax USA determines that a hydrant is out of service (OOS) or should be
designated as such,the crew leader will promptly notify the Owner and install out of service rings or bags as applicable.The hydrant
will remain out of service until necessary repairs are completed and full operability is restored. Once the hydrant is returned to
service, Hydromax USA will perform the required testing and maintenance at the applicable unit rate.
3.0.P Fire Hydrant Minor Repairs
HydromaxUSA.com 7
understand the present I protect the future
Hydromax USA will provide labor in four-hour increments for the following minor fire hydrant repairs. Final scope of work will be
defined by Owner prior to Hydromax USA mobilization and start of project.
• Upper Barrel Repair(labor only). Hydromax USA will repair and/or replace all necessary components within the upper portions
of the hydrant,from the operating nut downwards to the top of the break away(upper barrel)flange,to return the hydrant
to working order. Hydrant rotation shall also be considered as an upper barrel repair.
• Lower Barrel Repair(labor only). Hydromax USA will repair and/or replace all necessary components of the hydrant from the
top of the break away(upper barrel)flange to the bottom of the hydrant foot valve to return the hydrant to working order.
• Hydrant Extension (6-18 inches; labor only). Hydromax USA will raise hydrant six (6) to eighteen (18) inches to ensure the
pumper nozzle is at the required above-grade height per AWWA M-17. Materials provided by Owner.
3.0.Q Fire Hydrant ID Tags
Hydromax USA will furnish and install fire hydrant identification tags during fire hydrant testing and maintenance. If this work is
performed at a time other than during fire hydrant testing and maintenance,then the field technician hourly rate will apply.
3.0.R Fire Hydrant Road Markers
Hydromax USA will furnish and install reflective road markers during fire hydrant testing and maintenance. If this work is performed
at a time other than during fire hydrant testing and maintenance,then the field technician hourly rate will apply.
3.0.S Adder for Dechlorination during Flushing
Additional fee to add dechlorination to hydrant flushing. Contractor will provide dechlorination tablets.
3.0T Adder for 2"d Trip to Hydrant for 2nd Coat Painting or Other Services
Additional fee for return visit to paint hydrants second coat(top coat after primer/2 part epoxy second coat/etc)or other services
as requested.
4.0 FLUSHING SERVICES
• 4.0.A Non-UDF Flushing Services
Hydromax USA will execute hydrant flushing (non-UDF) using a single-person daily rate. Crews will flush hydrants for a pre-
determined amount of time or until achieving a clear white bucket test for water quality. Hydromax USA will collect water
samples for iron concentrations,chlorine residual levels,and turbidity.The Owner will test all water samples via a third-party
testing lab.
• 4.0.B Unidirectional Flushing Services(UDF)
Hydromax USA will execute unidirectional flushing(UDF)program using a two-person daily rate. Crews will flush the sequence
hydrants for up to three (3)water column turnovers or achieve a clear white bucket test for water quality,whichever occurs
first. Hydromax USA will collect water samples for iron concentrations,chlorine residual levels,and turbidity. The Owner will
test all water samples via a third-party testing lab.
5.0 ACOUSTIC LEAK DETECTION
Hydromax USA provides a comprehensive suite of leak detection services designed to help utilities accurately locate leaks,prioritize
repairs, and strengthen operational awareness across their distribution systems. By combining systematic acoustic surveys,
advanced correlation techniques, and continuous monitoring technologies,these services enable utilities to identify hidden leaks
that might otherwise remain undetected within the network—supporting both rapid response to active leaks and longer-term
strategies to reduce water loss and recover lost revenue.
HydromaxUSA.com 8
understand the present I protect the future
• 5.0.A Acoustic Leak Detection—Analysis&Correlating
Hydromax USA provides specialized leak analysis and correlation services to confirm and accurately locate leaks identified
during the acoustic survey process.When an acoustic signature indicative of a potential leak is detected,trained technicians
perform correlation using advanced leak detection equipment to estimate the leak location between access points such as
valves or hydrants.Ground microphone investigations are then conducted to precisely pinpoint the leak location.All confirmed
leaks are documented with GPS coordinates,field observations, and supporting data and are immediately communicated to
the utility to support rapid repair response and operational decision-making..
• 5.0.B Acoustic Leak Detection Program—Metallic(more than 900 miles annually)
This service includes a comprehensive acoustic leak detection survey of metallic water distribution pipelines where annual
survey quantities exceed 900 miles. Hydromax USA field crews perform systematic inspections of hydrants,valves, and other
accessible listening points at typical intervals of approximately 500 feet.Using advanced acoustic listening equipment and GPS-
enabled mobile GIS platforms, technicians systematically inspect system assets while mapping inspection results and
documenting acoustic readings. Potential leak noise signatures are identified, recorded, and spatially mapped to support
further analysis and correlation investigations needed to accurately locate leaks.
• 5.0.0 Acoustic Leak Detection Program—Metallic Pipe(under 900 miles annually)or Non-Metallic Pipe Survey
This service provides acoustic leak detection surveys for smaller programs involving less than 900 miles of metallic pipe
annually or for systems containing non-metallic pipelines such as PVC. For non-metallic pipe systems, Hydromax USA utilizes
a more detailed survey methodology that includes listening points approximately every 200 feet by incorporating service
connections and meter boxes to improve detection sensitivity.Using advanced acoustic listening equipment and GPS-enabled
mobile GIS platforms, technicians systematically inspect system assets while mapping inspection results and documenting
acoustic readings. Potential leak noise signatures are identified, recorded, and spatially mapped to support further analysis
and correlation investigations needed to accurately locate leaks.
• 5.0.D Real-Time Acoustic Leak Detection Monitoring Equipment(Includes 1st Year of Remote Access License)
This item includes the supply of real-time acoustic leak detection monitoring devices designed to convert existing fire hydrants
into smart monitoring nodes capable of continuously monitoring distribution system conditions. Each device includes
integrated acoustic sensors, environmental monitoring capabilities, and wireless communication hardware that transmits
operational data to a secure cloud-based monitoring platform. The equipment package includes the first year of platform
access, which provides automated leak detection analytics, alert notifications, device status monitoring, and dashboard
visualization tools that allow utility personnel to monitor system conditions and respond quickly to emerging leak events.
• 5.0.E Real-Time Acoustic Leak Detection Monitoring Equipment—Deployment/Installation
Hydromax USA will perform field deployment and installation of real-time monitoring devices at designated locations
throughout the distribution system.Installation involves mounting the monitoring unit onto an existing hydrant outlet or other
approved asset without interrupting system operations. Each installed device is activated, configured for cellular
communications,and integrated into the monitoring platform to ensure proper operation and data transmission. Installation
activities include verification of device functionality and confirmation that the monitoring node is successfully communicating
with the cloud-based analytics platform.
• 5.0.F Real-Time Acoustic Leak Detection Monitoring Equipment—Removal/Relocation
This service includes the removal or relocation of previously installed monitoring devices as system priorities evolve. Devices
may be redeployed to new locations identified through ongoing leak detection analysis, operational needs, or changing risk
conditions within the distribution system. Hydromax USA technicians will safely remove the monitoring device,transport it to
HydromaxUSA.com 9
understand the present I protect the future
the new location, reinstall the unit, and reconfigure the device within the monitoring platform to ensure continuous
monitoring and data reporting.
• 5.0.G Real-Time Acoustic Leak Detection Monitoring—License/Access Per Annum for Years 2+
This item provides annual subscription access to the cloud-based monitoring platform following the initial first-year license
included with the monitoring device. The subscription includes continued access to automated acoustic data analysis, leak
event detection algorithms, alert notifications, device status monitoring, and historical data visualization tools. The annual
license ensures ongoing connectivity between field monitoring devices and the analytics platform, allowing the utility to
maintain continuous monitoring capability and rapid response to potential leak events throughout the subscription period.
6.0 WASTEWATER SERVICES
Hydromax USA will provide the appropriate equipment and trained staff to perform the following wastewater cleaning and
inspection services as defined and as approved by Owner prior to Hydromax USA mobilization and start of project.
• 6.0.A Multi-Sensor Inspection(MSI)
Hydromax USA will perform a comprehensive assessment of existing sanitary sewer mains and connections 24 inches in
diameter and larger using Pipeline Assessment Certification Program (PACP) internal closed-circuit television (CCTV), Sonar,
and Multi-Sensor Inspection (MSI)technologies.These inspections will be conducted to digitally document and evaluate the
condition of the wastewater infrastructure.The scope of work includes wastewater pipes located in a variety of environments,
including improved streets, arterial and primary roads, backyards, and unimproved easements. Hydromax USA is equipped
with all-terrain vehicles suitable for accessing challenging terrain,as well as any specialized equipment necessary for safe and
compliant access to elevated manholes, in full accordance with The Loss Control Manual. No cleaning of the sanitary sewers
will be performed prior to CCTV and Sonar inspection unless explicitly requested by the Utility. Hydromax USA will furnish all
labor, including competent PACP-certified technicians, as well as all necessary equipment,tools, accessories, and materials
required to complete the CCTV and Sonar inspections of the designated 24-inch and larger diameter sanitary sewer lines.
• 6.0.B Multi-Sensor Inspection(MSI)Data Processing&Reporting
Hydromax USA will perform a multi-sensor inspection of the wastewater system using advanced technology that
simultaneously captures CCTV video, laser profiling,sonar, and other relevant data to assess the condition and geometry of
the pipe. This comprehensive data set provides insight into structural defects, debris accumulation, sediment levels, and
potential capacity restrictions. Once collected, all inspection data will be securely transmitted to PIPC for processing and
analysis. PIPC will compile the data into a detailed report that includes visual documentation, cross-sectional profiles, and
condition assessments, enabling the utility owner to make informed decisions about maintenance, rehabilitation, or further
investigation.
• 6.0.0 Heavy Wastewater Cleaning
If additional debris or impediments to inspection are observed following the initial light cleaning, Hydromax USA will seek
approval from the Owner to proceed with heavy cleaning. Heavy cleaning will be necessary in sections of pipe containing
significant root intrusion, large accumulations of debris, or several inches of sand and gravel, and will involve the use of
enhanced hydraulic nozzles and root cutters. Notification of the need for heavy cleaning will be submitted immediately.
Hydromax USA will utilize an Instant Notification App to promptly alert the Owner of all heavy cleaning requirements. This
system will be capable of delivering simultaneous alerts to up to 10 client points of contact and will include photographic
documentation of the pipe condition and debris as part of the notification submission.
• 6.0.D Siphon Cleaning&Assessment
Hydromax USA will perform the cleaning and assessment of the wastewater siphon using specialized procedures tailored to
its inverted design and limited access. Most siphons are constructed with multiple barrels, allowing flow to continue through
HydromaxUSA.com 10
understand the present I protect the future
one or more barrels while another is temporarily taken out of service. The process begins with site preparation, safety
protocols,and flow control—typically achieved by plugging the targeted barrel to isolate it for cleaning while maintaining flow
through the remaining active barrels.Crews will access the siphon through existing structures and utilize high-velocity jetting
or mechanical tools to remove accumulated debris,which will be vacuumed and properly disposed of. Following cleaning,the
isolated barrel will be dewatered to allow for a thorough CCTV inspection using robotic or push cameras.The inspection will
be conducted in accordance with NASSCO PACP standards to evaluate the internal condition of the siphon, identifying any
structural or operational defects.All findings,including video documentation and condition assessments,will be compiled into
a detailed report to support ongoing maintenance or rehabilitation planning.
• 6.0.E Manhole Assessment(Level 1)
Hydromax USA will perform a NASSCO MACP (Manhole Assessment Certification Program) Level 1 inspection. This is a
standardized visual assessment performed from the ground surface without confined space entry. It involves collecting a GPS
point, documenting basic structural and operational conditions of a manhole using NASSCO's defect codes. The inspection
includes observations of the frame, cover, chimney, cone, barrel, and invert to identify issues such as corrosion, cracks,
infiltration,and other visible defects.This level of inspection is typically used for preliminary condition assessments or in areas
where access is limited.
• 6.0.F Manhole Assessment(Level 2 w/3D Scan)
Hydromax USA will perform a NASSCO MACP Level 2 manhole inspections using advanced photogrammetry 3D scanning
technology to deliver high-resolution, detailed assessments of manhole conditions.This inspection includes collecting a GPS
point, and capturing structural, operational, and maintenance defects in accordance with NASSCO standards and includes a
full 3D model of the manhole interior.The photogrammetry 3D scan provides precise measurements and visualizations that
enhance condition assessment,asset management,and rehabilitation planning.TREKK 360 camera system or similar utilized.
• 6.0.G Elevated Manhole Access
To safely access a wastewater manhole elevated more than 4 feet above grade, Hydromax USA utilizes a combination of fall
protection equipment,extension ladders,and custom access platforms as needed.Crews first assess site conditions and secure
the area. Fall protection harnesses and anchor points are used in compliance with OSHA regulations.
• 6.0.H Smoke Testing
Hydromax USA will conduct wastewater smoke testing to identify defects such as illicit connections,broken pipes,and inflow
sources within the sanitary sewer system. The process begins with distributing door hangers or notices to all affected
properties at least 24 to 48 hours in advance to inform residents about the upcoming testing and what to expect. During
testing, non-toxic,white smoke is introduced into the wastewater system using a high-capacity blower.As the smoke travels
through the pipes, it escapes through defects such as cracks, open cleanouts, and improper connections, which are then
documented. Each defect location is recorded using GPS to ensure precise mapping and reporting. This data helps utility
owners prioritize maintenance and reduce excessive stormwater inflow into the system. (no plugging or sandbagging)
• 6.0.1 Flow Monitoring
Hydromax USA will conduct wastewater flow monitoring by strategically installing flow meters within the sanitary sewer
system to capture real-time data on flow rates, depth, and velocity over a designated monitoring period. This service is
essential for understanding system performance during dry and wet weather conditions.Our team handles all aspects of the
deployment, including site selection,equipment installation,calibration, maintenance, and data retrieval.The collected data
is compiled into non-engineered reports that include detailed charts, graphs, and summaries, providing municipalities and
engineers with a clear understanding of wastewater capacity,infiltration/inflow patterns,and peak flow conditions to support
planning and decision-making.
HydromaxUSA.com 11
understand the present I protect the future
6.011 Flow Meter Installation for Flow Monitoring
Hydromax USA provides turnkey flow monitoring installation services to support accurate data collection for sewer system
evaluation studies (SSES), infiltration and inflow (I/I) analysis, and capacity assessments. Our experienced field crews install
and maintain advanced flow monitoring equipment in sanitary and storm sewer systems,ensuring reliable, real-time data to
help utilities make informed decisions.
Each installation is performed with a focus on safety, data integrity, and minimal disruption to the system. Our team handles
everything from pre-installation site assessments and equipment calibration to secure installation in manholes and ongoing
data verification.We utilize industry-leading sensors to capture flow depth,velocity,and surcharge conditions in a wide range
of pipe sizes and flow environments.
6.012 Flow Meter Maintenance
Hydromax USA provides comprehensive flow monitoring maintenance services to ensure the accuracy, reliability, and
longevity of deployed flow monitoring equipment. Our experienced field technicians perform scheduled and emergency
maintenance on temporary and permanent flow monitors used in wastewater and stormwater systems.
Services include:
• Site inspections and equipment calibration
• Data quality verification and troubleshooting
• Battery replacement and sensor cleaning
• Firmware updates and hardware repairs
• Relocation or removal of monitors as needed
6.013 Flow Meter Final Report
Hydromax USA's Monthly Flow Monitoring Reports provide a clear,data-driven summary of flow conditions observed at each
monitored site within a sanitary or storm sewer system. Each report is designed to give utility managers, engineers, and
decision-makers a comprehensive view of system performance over the monitoring period.
The report includes:
• Daily Flow Trends:Graphical and tabular data showing average, minimum,and peak flows.
• Rainfall Correlation: Analysis of rainfall data overlaid with flow response to identify potential I&I (Infiltration and
Inflow)patterns.
• Diurnal Patterns: Flow curves illustrating system behavior during typical weekdays and weekends.
• Event Logging: Identification and detailed breakdown of notable flow events, including wet weather spikes or dry
weather anomalies.
• Site Performance Summary:Comparison to historical data or established benchmarks for each metering location.
• Data Quality Assurance: Documentation of meter uptime, sensor calibration status, and any maintenance activities
or data adjustments.
All flow data is collected using calibrated, high-accuracy equipment installed and maintained by Hydromax USA's experienced
field technicians. The result is reliable, actionable data to support capital planning, I&I reduction efforts, and regulatory
compliance.
• 6.0.J Rain Gauge Installation
Hydromax USA will conduct rain gauge monitoring to support comprehensive flow monitoring of wastewater systems. By
strategically installing and maintaining rain gauges throughout the service area,we accurately capture precipitation data that
directly correlates with wastewater flow patterns. This rainfall information is integrated with flow monitoring data to help
HydromaxUSA.com 12
understand the present I protect the future
identify infiltration, inflow, and overall system performance under various weather conditions. Hydromax USA provides non-
engineered, clear, and concise reports summarizing the collected rain gauge and flow data, enabling clients to better
understand system behavior and make informed operational decisions.
• 6.0J1 Rain Gauge Maintenance
Hydromax USA provides comprehensive rain gauge maintenance services to ensure accurate and reliable precipitation data
for municipal stormwater programs, flood forecasting, and regulatory compliance. Our trained field technicians perform
routine inspections, calibrations, and cleanings to eliminate debris, biological buildup, or mechanical faults that can
compromise gauge performance.
• Services include:
• Visual inspection and functional testing of gauges
• Removal of debris and obstructions from collection funnels
• Verification and calibration of tipping mechanisms or electronic sensors
• Data logger checks and battery replacements
• Documentation of service activities and condition reports
• 6.0.K Easement Access
Hydromax USA will apply an additional charge for accessing wastewater manholes located more than 50 feet off the curb of a
paved road during wastewater cleaning,CCTV inspections,or Multi-Sensor Inspection(MSI)services.This fee accounts for the
increased complexity and resource requirements associated with reaching these remote manholes.
To navigate challenging terrains or private properties, Hydromax USA employs specialized equipment such as compact CCTV
systems mounted on all-terrain vehicles and easement cleaning machines.These portable units are designed to access hard-
to-reach areas, ensuring comprehensive inspections even in difficult conditions.
7.0 ADDITIONAL MISCELLANEOUS SERVICES
Hydromax USA may provide the following additional miscellaneous services as defined and as approved by Owner prior to
Hydromax USA mobilization and start of project.
• 7.0.A GIS Data Analyst Support Services
Hourly rate for performing additional GIS support services not specifically defined in other sections of this proposal.
• 7.0.B Confined Space Entry Tech Services
Additional rate per asset to perform services which require confined space entry. Hydromax USA will adhere to related OSHA
requirements.
• 7.0.0 Maintenance of Traffic(MOT beyond arrow boards and cones).
Daily rate for additional MOT required outside of cones, arrow boards, and flashers to perform the required scope of work.
Cones,arrow boards,and flashers are provided as part of our standard temporary MOT.
7.0.C1 Maintenance of Traffic(MOT beyond arrow boards and cones)—Water Services
7.0.C2 Maintenance of Traffic(MOT beyond arrow boards and cones)—Wastewater Services
• 7.0.D Test Cut and Shut-Down Support Services
Hourly rate to provide on-call test cut and shut-down support services to the utility in support of emergency and planned
operations.
HydromaxUSA.com 13
understand the present I protect the future
• 7.0.E Water Services Field Technician
Hourly rate for a single field technician with equipment to perform additional water non-repair services not specifically defined
in other sections of this proposal.
• 7.0.F Wastewater Services Field Crew(VAC)
Hourly rate for a two-person crew with VAC equipment to perform additional services not specifically defined in other sections
of this proposal.Work performed during normal working hours.
• 7.0.G Wastewater Services Field Crew(CCTV)
Hourly rate for a two-person crew with CCTV equipment to perform additional services not specifically defined in other sections
of this proposal.Work performed during normal working hours.
• 7.0.H Wastewater Services Field Technician
Hourly rate for additional wastewater technician to perform services not specifically defined in other sections of this proposal.
Typically, this line item is used to add an additional crew member to a wastewater crew when necessary, and no additional
equipment is needed.Work performed during normal working hours.
• 7.0.1 GPS-only of Assets
Per unit rate to collect sub-foot GPS data only for identified assets. No other information will be collected or provided for work
performed under this line item.The work to be performed while crews are mobilized for the base contract work.
HydromaxUSA.com 14
understand the present I protect the future
8.0 CLARIFICATIONS
• Unless otherwise stated in the proposal, this proposal does not include any payment of prevailing wages or certified
payroll reporting.
• There are no hazardous materials present in the project area.
• On CCTV,Cleaning,and Multi-Sensor projects:
o The unit price quoted for light cleaning and CCTV inspection on a per linear foot(LF) basis is valid only when a
minimum of 2,000 LF of wastewater main is continuous and accessible for uninterrupted inspection and cleaning.
If the total footage falls below 2,000 LF,or if the sections are non-contiguous—necessitating repeated equipment
setup, relocation,or remobilization—the work will be invoiced at the applicable hourly rate.
o This proposal does not include bypass pumping or pipe plugging unless otherwise stated within.
o Client will be responsible for the costs associated with any repairs or extractions that are required due to existing
structural defects or failures.
o This proposal does not include any clearing/grubbing for easement roads or access.
o Customer will provide access to the work site that will be adequately sized for HUSA's equipment and will be a
maximum of fifty(50)feet from manholes that need to be accessed.
o Client will provide a dump location for the debris, within 1 hour drive of the project area and not restricted in
operating hours.
o Client will provide water access within one mile of the work area.
o Hydromax USA will not be responsible for damage or cleaning to residential homes/bathrooms due to debris
backflushing through residential toilets, where the wastewater lateral installation/angle contributes to the
damage or issues with venting at residential homes.
HydromaxUSA.com 15
understand the present I protect the future
9.0 PROGRAM PRICING(REV 3.3.26)
Hydromax USA proposes to perform the following scope of work as defined in the sections above at the for the TIPS pricing
referenced in the table below. It is understood that all quantities are approximate totals and non-binding.
Item# Service Name Service Description Unit TIPS Price EST.QTY Ext.Price
1.0 Administration&Travel
,� n ^ Crew Travel/ 8 Hour Travel Day for Crew Per Person 0 0 0
TC-I'c n Mobilization to Project Site /Pcr Day
Lodging and Per Lodging and Per Dicm for Per Person
S+e n Non Local Project /Pcr Day $200.00 0 0
2.0 Valve Assessment,Maintenance&Information Management
Valve Assessment, AWWA M44 Valve
2.0.A 4 Inch or smaller Assessment,4 Inch or Per Valve $59.48 1,500 $89,220.00
Diameter Valve smaller Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.B 6-inch Diameter Assessment,6-inch Per Valve $61.65 2500 $154,125.00
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.0 8-inch Diameter Assessment,8-inch Per Valve $62.73 2500 $156,825.00
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.D 10-inch Diameter Assessment, 10-inch Per Valve $64.89 50 $3,244.50
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.E 12-inch Diameter Assessment, 12-inch Per Valve $64.89 250 $16,222.50
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.F 14-inch Diameter Assessment, 14-inch Per Valve $64.89 20 $1,297.80
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.G 16-inch Diameter Assessment, 16-inch Per Valve $66.95 100 $6,695.00
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.H 18-inch Diameter Assessment, 18-inch Per Valve $77.25 0 0.00
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.1 20-inch Diameter Assessment,20-inch Per Valve $97.85 40 $3,914.00
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.J 24-inch Diameter Assessment,24-inch Per Valve $118.45 30 $3,553.50
Valve Diameter Valve
HydromaxUSA.com 16
understand the present I protect the future
Valve Assessment, AWWA M44 Valve
2.0.K 30-inch Diameter Assessment, 30-inch Per Valve $180.25 0 0
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.L 36-inch Diameter Assessment, 36-inch Per Valve $200.85 10 $2,008.50
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.M 42-inch Diameter Assessment,42-inch Per Valve $216.30 0 0
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.N 48-inch Diameter Assessment,48-inch Per Valve $270.38 0 0
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.0 54-inch Diameter Assessment,54-inch Per Valve $297.41 0 0
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.P 60-inch Diameter Assessment,60-inch Per Valve $378.53 0 0
Valve Diameter Valve
Valve Assessment, AWWA M44 Valve
2.0.Q Over 60-inch Assessment, Over 60-inch Per Valve $432.60 0 0
Diameter Valve Diameter Valve
Valve Cannot Be AWWA M44 Valve
2.0.R Located(CNL) Assessment,Valve Cannot Per CNL $59.48 0 0
Be Located(CNL)
AWWA M44 Valve
Valve Cannot Be
2.0.5 Accessed(CNA) Assessment,Valve Cannot Per CNA $59.48 0 0
Be Accessed(CNA)
Valve Located and AWWA M44 Valve
2.0.T Accessed, Not Assessment,Valve Located Per CNO $59.48 0 0
Operated(CNO) and Accessed, Not Operated
(CNO)
Valve Raise(up to Valve Raise(up to 18-inches
18-inches in Grass,
2.0.0 Dirt,Gravel; Labor in Grass, Dirt,Gravel; Labor Per Valve $38.63 0 0
Only) Only)
Valve Raise(up to
18-inches in Valve Raise(up to 18-inches
2.0.V Asphalt w/Cold in Asphalt w/Cold Patch; Per Valve $115.36 0 0
Patch; Labor Only) Labor Only)
Valve Realign(up Valve Realign(up to 18-
to 18-inches in
2.0.W inches in Grass, Dirt,Gravel; Per Valve $77.25 0 0
Grass, Dirt,Gravel; Labor Only)
Labor Only)
Valve Realign(up
Valve Realign(up to 18-
to 18-inches in
2.0.X Asphalt w/Cold inches in Asphalt w/Cold Per Valve $230.72 0 0
Patch; Labor Only) Patch;Labor Only)
HydromaxUSA.com 17
understand the present I protect the future
Valve Operating Valve Operating Nut Repair
2.0.Y1 Nut Repair (up to 48-inches;No Per Valve $750.00 0 0
Excavation)
Valve Operating Valve Operating Nut Repair
2.0.Y2 Nut Repair (4'-10'-inches; No Per Valve $1,200.00 0 0
Excavation)
Assessment Services for Air
2.0.Z ARV Assessment Release Valve Per Hour $300.00 0 0
3.0 Fire Hydrant Assessment,Maintenance&Information Management
Fire Hydrant Fire Hydrant Testing and
Testing and
3.0.A Maintenance Maintenance(Single; No Per Hydrant $54.08 0 0
Paint)
(Single; No Paint)
Fire Hydrant
Testing and Fire Hydrant Testing and
3.0.B Maintenance Maintenance(Single;w/ Per Hydrant $61.29 0 0
(Single;w/One- One-Color Paint)
Color Paint)
Fire Hydrant
Testing and Fire Hydrant Testing and
3.0.0 Maintenance Maintenance(Single;w/ Per Hydrant $71.59 0 0
(Single;w/Two- Two-Color NFPA Paint)
Color NFPA Paint)
Fire Hydrant
Testing and Fire Hydrant Testing and
3.0.D Maintenance Maintenance(Two-Hydrant; Per Hydrant $108.15 0 0
(Two-Hydrant;No No Paint)
Paint)
Fire Hydrant
Testing and Fire Hydrant Testing and
3.0.E Maintenance Maintenance(Two-Hydrant; Per Hydrant $115.36 0 0
(Two-Hydrant; One-Color Paint)
One-Color Paint)
Fire Hydrant
Testing and
Fire Hydrant Testing and
Maintenance
3.0.F (Two Hydrant;w/ Maintenance(Two-Hydrant; Per Hydrant $125.66 0 0
Two Color NFPA w/Two-Color NFPA Paint)
Paint)
M-17 Multi-Port/
Multi Hydrant Fire M-17 Multi-Port/Multi-
Hydrant Fire Flow Testing Per Hydrant $180.00 0 0
Maintenance(No and Maintenance(No Paint;
Two-Person Crew)
Paint)
M-17 Multi-Port/ M-17 Multi-Port/Multi-
Multi-Hydrant Fire Hydrant Fire Flow Testing
3.0.H Flow Testing and Per Hydrant $225.00 0 0
Maintenance and Hydrant(One-Color
(One Color Paint) Paint;Two-Person Crew)
HydromaxUSA.com 18
understand the present I protect the future
M-17 Multi-Port/ M-17 Multi-Port/Multi-
Multi-Hydrant Fire Hydrant Fire Flow Testing
3.0.1 Flow Testing and and Maintenance(Two- Per Hydrant $265.00 0 0
Maintenance(Two Color NFPA Paint;Two-
Color NFPA Paint) Person Crew)
Fire Hydrant
Testing and Fire Hydrant Testing and
3.0.J Maintenance(High Maintenance(High Pressure Per Hydrant $81.11 0 0
Pressure; No Paint) over 125 PSI; No Paint)
Fire Hydrant Fire Hydrant Testing and
Testing and Maintenance(High Pressure
3.0.K Maintenance(High Per Hydrant $88.32 0 0
Pressure;One- over 125 PSI;One-Color
Color Paint) Paint)
Fire Hydrant Fire Hydrant Testing and
Testing and
Maintenance(High Pressure
3.0.L Maintenance(High Per Hydrant $98.62 0 0
over 125 PSI;w/Two-Color
Pressure;w/Two- NFPA Paint)
Color NFPA Paint)
3.0.M Fire Hydrant CNL Fire Hydrant Cannot Be Per Hydrant $25.00 0 0
Located(CNL)
3.0.N Fire Hydrant CNA Fire Hydrant Cannot Be Per Hydrant $25.00 0 0
Accessed(CNA)
3.0.0 Fire Hydrant 005 Fire Hydrant Out of Service Per Hydrant $52.50 0 0
(OOS)
Fire Hydrant Minor
Repair(4-Hour Fire Hydrant Minor Repair Per
3.0.P Minimum; No (4-Hour Minimum; No Hour/Per $154.50 0 0
Excavation; Labor Excavation; Labor Only) Person
Only)
3.0.Q Fire Hydrant ID Tag Furnish&Install Fire Per Tag $14.42 0 0
Hydrant ID Tag
Fire Hydrant Furnish&Install Fire
3.0.R Reflective Road Hydrant Reflective Road Per Marker $12.36 0 0
Marker Marker
Adder for
3.0.S Dechlorination Add Dechlorination to Each $9.00 0 0
during Flushing Hydrant Flushing
Adder for 2"d Trip Adder for 2"d Trip to
3.0.T "d
to Hydrant Hydrant fortCoat Each $65.00 0 0
Painting or Other Services
4.0 Flushing Services
Fire Hydrant Fire Hydrant Maintenance Per Day/Per
4.0.A Flushing Services Flushing(Non-UDF; 1- 1-Person $1,236.00 0 0
(Non-UDF) Person Crew;8-Hour Day) Crew
HydromaxUSA.com 19
understand the present I protect the future
Unidirectional Unidirectional Flushing Plan Per Day/Per
4.0.B Flushing Services Execution Services(2- 2-Person $2,472.00 0 0
Person Crew;8-Hour Day) Crew
5.0 Acoustic Leak Detection
Acoustic Leak Acoustical Leak Detection Per
Detection--
5.0.A Analysis& Services-Analysis& Hour/Per $275.00 0 0
Correlating Correlating Person
Acoustic Leak
Detection Program Acoustic Leak Detection
5.0.B -Metallic(more Program-Metallic(more Per Mile $275.00 0 0
than 900 miles than 900 miles annually)
annually)
Acoustic Leak
Detection Program
Metallic Pipe Acoustic Leak Detection- Per
5.0.0 (under 900 miles Program Metallic Pipe Hour/Per $290.00 0 0
annually)or Non- (under 900 miles annually) Person
Metallic Pipe or Non-Metallic Pipe Survey
Survey
Real-Time Acoustic
Leak Detection Real-Time Acoustic Leak
Monitoring Detection Monitoring
5.0.D Equipment Equipment(Includes 1st Per Device $1,650.00 0 0
(Includes 1st Year Year of Remote Access
of Remote Access License)
License)
Real-Time Acoustic
Leak Detection Real-Time Acoustic Leak
Monitoring Detection Monitoring
5.0.E Per Device $60.00 0 0
Equipment-- Equipment--Deployment/
Deployment/ Installation
Installation
Real-Time Acoustic
Leak Detection Real-Time Acoustic Leak
Monitoring Detection Monitoring
5.0.F Per Device $90.00 0 0
Equipment-- Equipment--Removal/
Removal/ Relocation
Relocation
Real-Time Acoustic
Leak Detection Real-Time Acoustic Leak
Monitoring-- Detection Monitoring-- Per
5.0.G Device/Per $100.00 0 0
License/Access Per License/Access Per Annum
Annum for Years for Years 2+ Year
2+
6.0 Wastewater Services
HydromaxUSA.com 20
understand the present I protect the future
Multi-Sensor Multi-Sensor Inspection Per Linear
6.0.A $5.00 0 0
Inspection(MSI) (LiDAR,Sonar,&CCTV) Foot
Multi-Sensor
Inspection(MSI) Multi-Sensor Data Per Linear
6.0.B $3.15 0 0
Data Processing& Processing&Reporting Foot
Reporting
Heaving
6.0.0 Wastewater Heavy Wastewater Cleaning Per Hour $325.00 0 0
Cleaning
Siphon Cleaning& Siphon Cleaning, Per
6.0.D Hour/Per $650.00 0 0
Assessment Dewatering,&Assessment
Crew
Manhole
6.0.E Assessment(Level Manhole Assessment Each $75.00 0 0
1) (MACP Level 1)
Manhole Manhole Assessment
6.0.F1 Assessment(Level (MACP Level 2 w/3D Scan) Each $290.00 0 0
2 w/3D Scan) Depth of>26'
Manhole Manhole Assessment
6.0.F2 Assessment(Level (MACP Level 2 w/3D Scan) Each $365.00 0 0
2 w/3D Scan) Depth of 26'-60'
Manhole Manhole Assessment
6.0.F3 Assessment(Level (MACP Level 2 w/3D Scan) Each $525.00 0 0
2 w/3D Scan) Depth of 61-80'
Elevated Manhole Access Manhole Elevated
6.0.G Access more than 4 Feet Above Each $700.00 0 0
Grade
6.0.H Smoke Testing Smoke Testing&Reports Linear Foot $0.67 0 0
Flow Monitoring Flow Meter Installation for
6.0.11 Each $2,500.00 0 0
Installation Flow Monitoring
Flow Meter Flow Meter Monthly Per
6.0.12 Maintenance Maintenance Check unit/month $500.00 0 0
6.0.13 Flow Meter Final Flow Meter Final Analysis& Each $2,000.00 0 0
Report Report
Rain Gauge
6.0.J Installation Rain Gauge Installation Each $500.00 0 0
Rain Gauge Rain Gauge Monthly Per
6.0J1 $150.00 0 0
Maintenance Maintenance Check Unit/Month
HydromaxUSA.com 21
understand the present I protect the future
Adder for Easement Access Per Linear
6.0.K Easement Access More than 50 Feet off Curb Foot $1.50 0 0
Edge
7.0 Additional Miscellaneous Services
GIS Data Analyst Services in Per
7.0.A GIS Data Services Support of Asset Hour/Per $180.25 0 0
Management Program Person
Confined Space
7 0 B Entry Certified Confined Space Tech Per Asset $257.50 0 0
(Added to Services(2-Person Crew)
Services)
MOT Beyond Maintenance of Traffic
7.0.C1 Arrow Boards and (MOT Beyond Arrow Boards Per Day $1,854.00 0 0
Cones-Water and Cones)-Water
MOT Beyond Maintenance of Traffic
Arrow Boards and
7.0.C2 Cones (MOT Beyond Arrow Boards Per Day $3,200.00 0 0
and Cones)-Wastewater
Wastewater
Test Cut/Shut Valve Tech& Mapping Per
7.0.D Down Service and Services in Support of Hour/Per $242.05 0 0
Ma in Pipeline Repair(1-Person Person
pp g Crew;8-Hour Minimum)
Water Services Water Services Field Per
7.0.E Field Technician- Technician w/Equipment Hour/Per $154.50 0 0
Hourly (Non-Repair) Person
Wastewater Two-Person Wastewater Per
7.0.F Services Field Crew VAC Crew w/Equipment Hour/Per $325.00 0 0
(VAC) (Non-Repair) Crew
Wastewater Two-Person Wastewater Per
7.0.G Services Field Crew CCTV Crew w/Equipment Hour/Per $325.00 0 0
(CCTV) (Non-Repair) Crew
Wastewater Additional Wastewater Per
7.0.H Services Field Technician—No Equipment Hour/Per $150.00 0 0
Technician (Non-Repair) Person
Service to Collect Sub-Foot
7.0.1 GPS-only of Assets GPS Data Only(No Other Each $12.00 0 0
Data Collected)
Total $437,105.80
These are estimated quantities to be used for budgeting.Quantities given by customer are estimates.
HydromaxUSA.com 22
understand the present I protect the future
10.0 PROGRAM CONTRACTING
The TIPS Member must include the Vendor Name and TIPS Contract Name and Number on each purchase order so that
Hydromax USA can report contract use to TIPS.
Vendor Name:Hydromax USA LLC
TIPS Contract Name and Number: TIPS Contract 240501; MRO (Maintenance, Repair, and Operations Of Facilities and
Grounds)Supplies,Equipment,Tool Rental,Sales and Services)
11.0 ACCEPTANCE AND AGREEMENT
TIPS requires its members to execute a vendor agreement prior to the performance of any services. By signing below,the
TIPS Member accepts the scope of work, associated pricing, and supplemental terms and conditions provided herein. Once
signed by both the TIPS Member and Hydromax USA,this document shall constitute an agreement for HUSA to provide the
services as defined above.
Accepted on behalf of TIPS Member City of Port Arthur,Tx:
Signature: Title:
Name: Date:
Accepted on behalf of Hydromax USA LLC:
Signature: Title:
Name: Date:
HydromaxUSA.com 23
understand the present I protect the future
SUPPLEMENTAL TERMS AND CONDITIONS
TIPS CONTRACT 240501 MRO(MAINTENANCE,REPAIR,AND OPERATIONS OF FACILITIES AND GROUNDS)
SUPPLIES,EQUIPMENT,TOOL RENTAL,SALES AND SERVICES
The following terms and conditions(these"Terms")shall apply to all services Hydromax USA LLC("HUSA")performs
for TIPS Members(as defined in Section 1)in connection with the above-referenced TIPS contract:
THESE TERMS ARE AN OFFER BY HUSA TO PERFORM SERVICES(AS DEFINED BELOW)FOR THE TIPS MEMBER SUBJECT
TO THE APPROVAL OF HUSA'S CREDIT DEPARTMENT,AND MAY BE ACCEPTED ONLY ON THESE EXACT TERMS AND
CONDITIONS. THESE TERMS, THE ACCEPTED PROPOSAL (AS DEFINED BELOW) AND ANY OTHER DOCUMENTS
SPECIFICALLY REFERRED TO HEREIN OR THEREIN (COLLECTIVELY,THE"AGREEMENT")CONSTITUTE THE EXCLUSIVE,
COMPLETE AND FINAL AGREEMENT BETWEEN HUSA AND THE TIPS MEMBER AND THERE ARE NO OTHER
AGREEMENTS, REPRESENTATIONS, PROMISES, OR STATEMENTS BETWEEN THE PARTIES EITHER EXPRESSED OR
IMPLIED. THIS AGREEMENT SUPERSEDES AND GOVERNS OVER THE TERMS AND CONDITIONS OF ANY DOCUMENT
PRESENTED,SENT OR ISSUED BY THE TIPS MEMBER. ALL DOCUMENTATION SHALL BE SUBJECT TO CORRECTION OF
STENOGRAPHIC ERRORS. NO VARIATION OF THE AGREEMENT SHALL BE BINDING UPON HUSA UNLESS AND UNTIL
SUCH VARIATION HAS BEEN ACCEPTED IN WRITING BY A DULY AUTHORIZED PERSON ON BEHALF OF HUSA. THIS
AGREEMENT AND ALL DISPUTES AND LEGAL ACTIVITIES SHALL BE GOVERNED BY AND CONDUCTED AS SET FORTH IN
THESE TERMS.
1. DEFINITIONS
a. "Accepted Proposal" means the proposal for Services submitted by HUSA in response to a TIPS posting
that has been accepted by the TIPS Member and agreed between the parties. These Terms are an essential
part of every HUSA proposal and must be executed by each party for a proposal to be deemed accepted.
b. "Person" means (whether or not capitalized) an individual, corporation, business trust, estate, trust,
partnership, association, joint venture, or other legal or commercial entity. This term also includes a
government or governmental subdivision,agency or instrumentality.
c. "TIPS Member" means any public entity or qualifying non-profit that has properly joined or utilizes The
Interlocal Purchasing System("TIPS").
2. SERVICES
The services to be performed by HUSA for the TIPS Member shall be detailed and described in the Accepted Proposal
(the"Services"). Any modifications of the Accepted Proposal and/or any Services set forth therein must be in writing
and agreed between the parties to be effective. All costs of changes to the Accepted Proposal and/or any Services
requested by the TIPS Member will be at the TIP Member's expense,subject to these Terms.
HydromaxUSA.com 24
understand the present I protect the future
3. FEES
a. Fees:The fee("Fee")for the Services shall be as agreed in the Accepted Proposal. Any changes to the Fee
must be in writing and agreed between the parties to be effective;provided, however,that,if the changes
to the Fee results in pricing that is not already included in the TIPS pricing and approved by TIPS,such pricing
will not be effective until it is approved by TIPS. Any changes to the Services requested by the TIPS Member,
or required by law or regulation or deemed necessary by HUSA may cause additional fees and costs.
b. Taxes:The TIPS Member shall be responsible and liable for the payment of all taxes, however designated
or incurred, which are paid or payable as a result of or otherwise in connection with the Agreement,
including, without limitation, federal, provincial and local, excise, sales, use, goods and services, value
added and any taxes or other amounts in lieu thereof, except for any taxes based on HUSA's net income
(collectively,"Taxes"). Notwithstanding the foregoing or anything herein to the contrary,(a)this provision
shall not apply if the TIPS Member is tax-exempt and it promptly provides HUSA with a copy of its tax
exemption certificate or other proof of tax-exempt status,and(b)the laws and regulations regarding Taxes
applicable to the TIPS Member shall control in the event of a conflict.
c. Payment Terms
i. All payments must be made in cash in U.S. Dollars unless otherwise agreed in writing by HUSA. If the
currency conversion rate utilized by the TIPS Member in making any payment results in the payment
of an amount less than the full amount due in U.S. Dollars for any reason (including, without
limitation,a change in the exchange rate between the conversion date and date of actual payment),
the TIPS Member shall pay any such shortfall to HUSA immediately upon HUSA's demand.
ii. When HUSA is engaged to perform full program management including all field correlation activities,
90%of payment is due upon completion of field testing.The remaining 10%is billed upon submission
of a draft report.
iii. All invoices are Net 30 and will be due and payable no later than 60 days from the date of invoice.
iv. All payments made by the TIPS Member shall be calculated without reference to any back charge,
set-off or counterclaim and shall be made free and clear of and without deduction for or on account
of any back charge,set-off or counterclaim.
v. All fees, expenses and other payments under the Agreement shall be paid without giving effect to
any Taxes. If the TIPS Member is required by law to deduct or withhold any amounts with respect to
any Taxes or if any Taxes are required to be paid by HUSA as a result or arising out of the Agreement,
the TIPS Member shall pay HUSA such additional amounts as shall be required so that the net amount
received by HUSA from the TIPS Member after such deduction, withholding or payment shall equal
the amounts otherwise payable to HUSA under the Agreement. If any Taxes are payable with respect
to the Fee paid or payable to HUSA under this Agreement, HUSA will add the amount of such Taxes
to its invoice and the TIPS Member shall pay HUSA such Taxes.
d. Late Payments:Where the TIPS Member fails to pay the Fees in accordance with these Terms, HUSA shall
have the right, in addition to any other rights or remedies available to it,to charge, and the TIPS Member
agrees to pay, interest on such overdue amounts at the rate of the greater of one percent (1.0%) and the
maximum amount permitted by law, per month calculated daily, compounded monthly both before and
after any court judgement in respect of the same from the date such payment was due including attorney
HydromaxUSA.com 25
understand the present I protect the future
fees. In addition, HUSA may suspend the performance of Services if any undisputed Fees are not paid to
HUSA in accordance with this Agreement.
e. TIPS Member Financial Conditions: If, during the period of performance of the Agreement, the financial
condition of the TIPS Member is determined by HUSA not to justify the terms of payment specified, HUSA
may demand full or partial payment in advance before performing (or continuing to perform) under the
Agreement, or satisfactory security or guarantees that invoices will be promptly paid when due, or, at its
option,without prejudice to other lawful remedies, may defer delivery or cancel the Agreement.
f. Cost of Collection:The TIPS Member shall be responsible and liable for paying all costs and expenses
incurred by HUSA associated with any collections and related efforts (including without limitation
reasonable attorneys'fees and costs).
4. WARRANTY
a. HUSA warrants that it will perform the Services in accordance with the specifications agreed in the Accepted
Proposal and in compliance with applicable law. This warranty shall expire twelve (12) months from the
date on which the Services were performed. In the event the Services do not conform to this warranty,
HUSA will reperform such nonconforming Services. If the Services cannot be reperformed, HUSA shall
refund the amount paid by the TIPS Member for such nonconforming Services. The TIPS Member's
exclusive remedy and HUSA's sole obligation under this warranty shall be limited to such reperformance or
refund.
b. HUSA further warrants that any parts provided in connection with the Services will be free from defects.
This warranty shall expire twelve (12) months from the date on which the part was provided by HUSA to
the TIPS Member. In the event a part is defective, HUSA shall,at its sole option,either(1)repair or replace
the defective part or components thereof, or(2) refund the price paid for the defective part to the TIPS
Member. The TIPS Member's exclusive remedy and HUSA's sole obligation under this warranty shall be
limited to such repair,replacement or refund,and shall be conditioned upon HUSA receiving written notice
of any defect within a reasonable period of time after the defect was discovered or by reasonable care
should have been discovered. In no event shall HUSA's liability for such defective part exceed the price paid
by the TIPS Member for such part.
c. DISCLAIMER. EXCEPT AS EXPRESSLY PROVIDED HEREIN,TO THE FULLEST EXTENT PERMITTED BY LAW,HUSA
HEREBY DISCLAIMS ALL WARRANTIES,WHETHER EXPRESS OR IMPLIED,ORAL OR WRITTEN,STATUTORY OR
OTHERWISE,WITH RESPECT TO SUITABILITY,DURABILITY,TITLE,NON-INFRINGEMENT,QUIET ENJOYMENT,
INTEGRATION, MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ALL WARRANTIES
ARISING FROM ANY COURSE OF DEALING, COURSE OF PERFORMANCE OR USAGE OF TRADE. HUSA DOES
NOT REPRESENT OR WARRANT (I) THAT THE SERVICES WILL MEET THE TIP MEMBER'S NEEDS OR
EXPECTATIONS OR WILL BE AVAILABLE FOR USE AT ANY PARTICULAR TIME,OR(II)THAT THE SERVICES WILL
BE SECURE,TIMELY, UNINTERRUPTED OR ERROR-FREE. EXCEPT AS SET FORTH HEREIN,THE SERVICES ARE
PROVIDED STRICTLY ON AN"AS IS,""AS AVAILABLE" BASIS.
5. LIMITATION OF LIABILITY
a. Exclusion of Consequential Damages: IN NO EVENT SHALL HUSA BE LIABLE TO THE TIPS MEMBER OR ANY
THIRD PARTY FOR INDIRECT, SPECIAL, PUNITIVE OR CONSEQUENTIAL DAMAGES, INCLUDING, WITHOUT
HydromaxUSA.com 26
understand the present I protect the future
LIMITATION, ANY DAMAGE OR INJURY TO BUSINESS EARNINGS, LOSS OF DATA, LOST PROFITS OR
GOODWILL, ANY INTERRUPTION, INACCURACY OR ERROR AND/OR PERSONAL INJURY SUFFERED BY ANY
PERSON ARISING FROM AND/OR RELATED WITH AND/OR CONNECTED TO THE SERVICES PROVIDED
UNDER THIS AGREEMENT, WHETHER BASED ON A WARRANTY CLAIM OR ON A CLAIM OR ACTION OF
AGREEMENT,TORT,OR OTHERWISE,EVEN IF HUSA IS ADVISED OF OR SHOULD HAVE BEEN AWARE OF THE
POSSIBILITY OF SUCH DAMAGES.
b. Time Limit for Claims: ANY AND ALL CLAIMS, DEMANDS AND ACTIONS THE TIPS MEMBER HAS OR MAY
HAVE AGAINST HUSA OR ANY OF ITS EMPLOYEES, DIRECTORS, OFFICERS, OR AGENTS ARISING FROM OR
IN CONNECTION WITH THE AGREEMENT MUST BE COMMENCED BY THE TIPS MEMBER WITHIN TWENTY-
FOUR(24) MONTHS OF THE DATE THAT THE CAUSE OF ACTION FIRST AROSE. ANY AND ALL CLAIMS NOT
COMMENCED WITHIN THIS TIME PERIOD WILL BE DEEMED WAIVED AND ABSOLUTELY BARRED. IN NO
EVENT SHALL ANY CLAIM OF THE TIPS MEMBER BE COMMENCED AFTER ANY APPLICABLE STATUTORY
LIMITATION HAS PASSED.
c. Limitation of Damages: IN RESPECT OF ANY CLAIM, DEMAND OR ACTION BY THE TIPS MEMBER AGAINST
HUSA WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR OTHERWISE, INCLUDING A
BREACH BY HUSA OF ANY OF ITS OBLIGATIONS(WHETHER OR NOT A FUNDAMENTAL BREACH), THE TIP
MEMBER'S EXCLUSIVE REMEDY SHALL BE TO RECEIVE FROM HUSA PAYMENT FOR ACTUAL AND DIRECT
DAMAGES UP TO THE LIMIT OF THE APPLICABLE INSURANCE PROVIDED BY HUSA (AS SET FORTH IN
SECTION 7 BELOW) IN CONNECTION WITH ITS SERVICES IN QUESTION. THE TIPS MEMBER
ACKNOWLEDGES AND AGREES THAT: (A)THE ESSENTIAL PURPOSE OF THIS SECTION 5(C) IS TO ALLOCATE
THE RISKS UNDER THIS AGREEMENT BETWEEN THE PARTIES AND LIMIT POTENTIAL LIABILITY;(B)THE FEES
WOULD HAVE BEEN SUBSTANTIALLY HIGHER IF HUSA WERE TO ASSUME ANY FURTHER LIABILITY OTHER
THAN AS SET FORTH HEREIN; AND (C) HUSA HAS RELIED ON THESE LIMITATIONS IN DETERMINING
WHETHER TO PROVIDE SERVICES TO THE TIPS MEMBER.
d. Claims Against HUSA:The TIPS Member acknowledges and agrees that,to the fullest extent permitted by
law,HUSA shall be the TIPS Member's sole and exclusive source for damages arising out of or in connection
with the Services being provided under this Agreement, and no claim shall be brought against any
employees, directors, officers, shareholders or partners of HUSA, unless the claim arises from the fraud,
dishonesty or illegal acts of the person providing the Services.
e. Proportional Liability: If the TIPS Member sustains any Damages (as defined below)for which HUSA and
another person are jointly and severally liable,the TIPS Member agrees that the loss it can recover from
HUSA shall be limited so as to be proportional to HUSA's relative contribution to the fault that caused the
Damages.
6. INDEMNITY
a. To the extent permitted by the laws and constitution of the TIPS Member's State,the TIPS Member agrees
to indemnify, defend and hold HUSA and its employees, directors, officers, shareholders or partners
(collectively, "HUSA Indemnitees") harmless from and against any and all claims, actions, lawsuits,
proceedings, damages, losses, liabilities, penalties, fines, costs, and expenses (including reasonable
attorneys'fees and court costs)(collectively,"Damages")arising from, related to or in connection with the
fraud, gross negligence or willful misconduct of the TIPS Member or its affiliates and its and their
employees,directors,officers,shareholders or partners.
HydromaxUSA.com 27
understand the present I protect the future
b. HUSA agrees to indemnify, defend and hold the TIPS Member harmless from and against any and all
Damages arising from, related to or in connection with the negligence or willful misconduct of HUSA or its
employees,directors,officers,shareholders or partners.
7. INSURANCE
a. Minimum Coverage. HUSA will maintain no less than the following insurance coverages and limits during
the term of this Agreement(each,a"Policy"and collectively,the"Policies").
i. Commercial General Liability ("CGL"): combined single limit of $1,000,000 per occurrence and
$2,000,000 in the aggregate;
ii. Automobile Liability ("Auto"): combined single limit of $1,000,000 with coverage for owned and
leased automobiles. Automobile coverage is only necessary if HUSA's vehicles are used in the
provision of Services hereunder and/or are brought onto the TIPS Member's site;
iii. Worker's Compensation: statutory limits for the jurisdiction in which HUSA provides Services
hereunder;
iv. Employers Liability:$1,000,000 per accident/disease;and
v. Umbrella Liability:$1,000,000 per occurrence and in the aggregate.
b. Additional Insured. HUSA will add the TIPS Member as an additional insured on each of the CGL and Auto
Policy if being used to meet the standard of the General Liability and Automobile Liability.
c. Certificates of Insurance. Upon written request of the TIPS Member, HUSA shall provide the TIPS Member
with current valid certificates of insurance verifying that the insurance requirements have been met and
the Policies are in full force and effect.
d. Notification. All Policies will [not be suspended, voided, cancelled, non-renewed or reduce below the
coverages or limits set out in (a) above unless replaced by a policy with at least the same coverages or
limits as the prior Policy except after thirty (30) days' prior written notice has been given to the TIPS
Member by certified mail,return receipt requested][provide a minimum thirty(30)day endeavor to notify
the TIPS Member,when available,by HUSA's insurer].
e. Damages. The TIPS Member waives all rights against HUSA and its employees, directors, officers,
shareholders or partners for recovery of damages to the extent these damages are covered by the Policies
maintained as required herein.
8. FORCE MAJEURE
HUSA is not responsible or liable for any delays or nonperformance arising from or in connection with any act of the
TIPS Member or any person acting on the TIPS Member's behalf, earth movement, fire, flood, explosion, the
elements,other catastrophes, acts of God,war, riot, civil disturbance, strike, lockout, refusal of employes to work,
labor disputes,shortage,acts of any governmental or regulatory authority substantially affecting HUSA's operations,
in the event HUSA suspends or discontinues business for any reason, or for any other reason beyond HUSA's
reasonable control.
HydromaxUSA.com 28
understand the present I protect the future
9. GOVERNING LAW;VENUE
Each of the TIPS Member and HUSA expressly agree that(a)this Agreement shall be governed by and construed in
accordance with the laws of the State of Texas without regard to the conflict of laws provisions thereof,and(b)any
action or proceeding relating to this Agreement shall be brought exclusively in a State court of competent jurisdiction
located in Denton County,Texas, or, if a Federal Court is legally required,a Federal Court of competent jurisdiction
in the Eastern District of Texas. Each Party hereby irrevocably consents to the jurisdiction of such courts and waives
any objections it may have to personal jurisdiction,venue or forum. In any action or proceeding to enforce rights
under this Agreement,the prevailing party will be entitled to recover costs and attorneys'fees.
10. TERM;TERMINATION
a. Term: This Agreement shall commence as of the date the parties execute these Terms and shall continue
until the completion of HUSA's Services, unless terminated earlier in accordance with this Agreement.
b. Termination for Convenience: Either party may terminate this Agreement at any time by providing thirty
(30)days' prior written notice to the other party.
c. Termination for Cause: This Agreement may be terminated immediately upon written termination from
one party(the"Terminating Party")to the other(the"Terminated Party")if any of the following occur:
i. the Terminated Party defaults in the performance of any of its material duties under this Agreement
and, after written notice of such default,fails to cure such default within thirty(30)days (or, if such
default cannot be cured in such time,does not give within thirty(30)days such assurance of cure as
shall be reasonably satisfactory to the Terminating Party);
ii. the Terminated Party is dissolved(other than pursuant to a consolidation,amalgamation or merger)
or has a resolution passed for its winding-up or liquidation (other than pursuant to a consolidation,
amalgamation or merger);
iii. a court having jurisdiction in the premises shall enter a decree or order for relief,and such decree or
order shall not have been vacated within sixty(60) days, in respect of the Terminated Party in any
involuntary case under any applicable bankruptcy, insolvency or other similar law now or hereafter
in effect, or appoint a receiver, liquidator, assignee, trustee, administrator, sequestrator or similar
official for the Terminated Party or any substantial part of its property or order the winding-up or
liquidation of its affairs;or
iv. the Terminated Party commences a voluntary case under any applicable bankruptcy, insolvency or
other similar law now or hereafter in effect, consents to the entry of any order for relief in an
involuntary case under any such law,consents to the appointment of a receiver,liquidator,assignee,
trustee,custodian,sequestrator or similar official for the Terminated Party or any substantial part of
its property, consents to the taking of possession by any such official or any substantial part of its
property, makes any general assignment for the benefit of creditors or fails generally to pay its debts
as they become due.
Each Party hereunder agrees that,if any of the events specified in clauses(ii),(ii)or(iv)of this Section
9(c)occurs,it shall use reasonable efforts to give written notice thereof to the other Party within five
(5)business days after the occurrence of such event.
HydromaxUSA.com 29
understand the present I protect the future
d. Effect of Termination: Upon termination of this Agreement by any party, HUSA shall immediately cease
the performance of the Services and the TIPS Member shall be liable for payment of all fees, costs and
other expenses and disbursements accrued or incurred up to the date of such termination in accordance
with this Agreement.
11. MISCELLANEOUS
a. Field Representative: A HUSA Field Representative may assist the TIPS Member, however, that
Representative has no authority to bind HUSA in any way. HUSA shall not be held liable or responsible for
any instructions or technical advice in connection with the Services hereunder.
b. Compliance with Laws:HUSA will not undertake any Services that are prohibited by government regulation
or the laws of the United States or the State of Texas or,as the case may be, by government regulation or
the laws of any jurisdiction in which the Services are carried out or in which the TIPS Member is
incorporated or has its principal place of business. HUSA will also not directly or indirectly pay or promise
to pay,or authorize the payment of any money,or give,promise to give or authorize the giving of anything
of value to any person, including any government official, legal professional or person affiliated with a
legal organization or institution,to obtain improper information or secure any improper advantage for the
TIPS Member in the course of carrying out the Services.
c. Relationship of Parties: As between themselves,the parties are independent contractors. Neither party
will be deemed to be an employee, agent, partner, joint venturer, or legal representative of the other
party for any purpose, and neither party will have any right, power, or authority to obligate the other
party.
d. Binding Agreement:This Agreement shall be binding upon and shall endure to the benefit of HUSA and
the TIPS Member and their respective heirs, executors, administrators, receivers, legal representatives,
successors and permitted assigns.
e. Assignment: Notwithstanding anything to the contrary contained herein, the obligations of HUSA under
these Terms may be assigned or delegated to any company affiliated with HUSA, including all subsidiaries
of HUSA and its employees and agents, provided that HUSA shall remain responsible to the TIPS Member
as otherwise provided.
f. Severability: In the event that any provision (or any portion of a provision) of these Terms shall for any
reason be held by a court of competent jurisdiction to be invalid,illegal,or unenforceable for any reason,
such invalidity, illegality or unenforceability shall not affect any other provision hereof and these Terms
shall be construed as if such invalid,illegal or unenforceable provision(or portion of a provision)had never
been contained herein in regards to that particular jurisdiction.
g. Publicity: HUSA may disclose the existence of these Terms, the Agreement or the relationship between
the parties. Without HUSA's prior written consent, the TIPS Member shall not use HUSA's name, logo,
trademark or service mark and shall not issue any press release or otherwise make any public statements
with respect to this Agreement or the contemplated arrangement hereunder.
h. Waiver. No provision of, right or privilege under this Agreement shall be deemed to have been waived by
any act,delay,omission or acquiescence on the part of any party,its agents or employees, but only by an
HydromaxUSA.com 30
p
understand the present I protect the future
instrument in writing duly executed by both parties. No waiver by any party of any breach or default of
any provision of this Agreement by the other party shall be effective as to any other breach or default,
whether of the same or any other provision and whether occurring prior to, concurrent with, or
subsequent to the date of such waiver.
i. Counterparts. This Agreement may be executed in counterparts(which may be exchanged by fax or PDF),
each of which will be deemed an original, but all of which together will constitute the same Agreement.
j. Acoustic Leak Detection
i. Monitoring Equipment Ownership
All SmartCap'" monitoring devices and associated mounting hardware supplied under this
Agreement shall become the property of the TIPS Member upon payment in full of the applicable
invoice. Hydromax USA shall retain no ownership interest in the installed hardware; however, any
embedded firmware and proprietary software contained within the monitoring equipment remains
the intellectual property of the manufacturer and is licensed for use with the monitoring system.
ii. Monitoring Platform License
Access to the monitoring platform and associated data analytics software is provided under a limited,
non-exclusive,non-transferable license for the duration of the applicable subscription term.The TIPS
Member may access and use the monitoring platform solely for internal operational purposes related
to the monitoring and management of its water distribution infrastructure.
iii. The TIPS Member shall not:
• reverse engineer the software platform
• copy or redistribute the software
• grant access to unauthorized third parties
All intellectual property rights in the software platform and analytics systems remain the property of
the manufacturer or its licensors.
iv. Data Transmission and Communications
Monitoring devices transmit data using third-party cellular communication networks and cloud
hosting services. Hydromax USA does not guarantee uninterrupted communications connectivity or
continuous data transmission and shall not be liable for temporary service interruptions caused by
cellular network availability, power disruptions, environmental conditions, or other factors outside
Hydromax USA's control.
v. Platform Renewal
The SmartCap'"" device includes one (1)year of monitoring platform access beginning upon device
activation.Continuation of platform access,automated event detection,and cloud data hosting after
the initial term requires renewal of the annual platform subscription identified in the pricing
schedule. Failure to renew the subscription does not affect ownership of the monitoring device but
may limit access to platform-based analytics and alert functionality.
HydromaxUSA.com 31