Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
P.R. 25265 - PURCHASE TWO NEW 1500 GPM TYPE I FIRE ENGINE APPARATUS.
----a Pir City of f�r.1 ort rthu�_ Teur, www.PortArthurTx.gov INTEROFFICE MEMORANDUM Date: November 5, 2026 To: The Honorable Mayor and City Council Through: Ron Burton, CPM, City Manager From: Antonio O. Mitchell, Interim Fire Chief RE: PR 25265, Purchase of two New 1500 GPM Type I Fire Engine Apparatus Introduction: The Fire Department requests City Council approval authorizing the City Manager to purchase two (2) Pierce Type I fire engines from Siddons-Martin Emergency Group of Denton, Texas, with offices in Port Arthur, Texas, through the Texas BuyBoard Cooperative Purchasing Program,in the total amount of$1,798,272.00. Background: The Fire Department has identified the need to replace aging fire apparatus that has reached the end of its useful frontline service life. The continued operation of aging,maintenance-intensive fire engines undermines fleet reliability, increases maintenance demands, and may compromise the Department's ability to consistently maintain operational readiness. Historically, the City has utilized custom-built fire apparatus to accommodate the Department's substantial emergency call volume, demanding operational workload, and specialized operational requirements. However, custom-built fire engines are associated with extended manufacturing and delivery timelines, which may range from four(4)to five(5)years. In consideration of the City's current financial constraints and the Department's immediate fleet replacement needs, the Fire Department has determined that purchasing two (2) standardized, non-custom Pierce Type I fire engines is a prudent interim strategy. The proposed acquisition is expected to yield approximately $1.6 million in savings compared to the anticipated cost of a comparable custom-built apparatus, with an estimated delivery timeframe of March 2027. "Remember,we are here to serve the Citizens of Port Arthur" P.O.Box 1089 X Port Arthur,Texas 77641-1089 X 409.983.8101 X FAX 409.982.6743 City of ort rthu�_ Texas www.Po rtArt h u rTx.gov The proposed purchase will allow the City to address critical fire apparatus replacement needs without incurring substantial costs and extended delivery delays associated with custom-built fire engines. The standardized, pre-engineered apparatus will provide the Department with several operational and financial advantages,including: • Cost Savings: The acquisition is expected to generate approximately $1.6 million in direct savings compared to the anticipated cost of comparable custom-built fire engines. • Expedited Delivery: An anticipated March 2027 delivery will substantially reduce the procurement delays associated with custom-built apparatus. • Fleet Standardization: Standardized equipment will promote personnel familiarity, facilitate cross-training, and improve operational consistency among fire crews. • Maintenance Efficiency: Common equipment platforms will simplify spare-parts procurement, streamline maintenance, and reduce potential repair-related downtime. • Operational Readiness: Replacing aging apparatus will strengthen fleet reliability and support the Department's ability to maintain effective frontline emergency response capabilities. Although custom-built apparatus remains the Department's preferred long-term procurement approach because of the City's high emergency call volume, demanding operating conditions, and unique service requirements,the proposed purchase represents a fiscally responsible interim solution. The Department anticipates returning to custom-built apparatus when the City's financial position permits. The purchase will be made through the Texas BuyBoard Cooperative Purchasing Program pursuant to Chapter 271 of the Texas Local Government Code and the City's existing interlocal cooperative purchasing agreement authorized by Resolution No. 02-341. Utilizing the cooperative purchasing program allows the City to purchase the apparatus through an established cooperative contract without conducting a separate competitive solicitation, provided the applicable statutory and contractual requirements are satisfied. Budget Impact: The total purchase price for the two(2)Pierce Type I fire engines is $1,798,272.00. Funds were budgeted in FY 2026-2027 in Capital Improvement Account Number 625-19-047-8522-00-10- 000 "Remember,we are here to serve the Citizens of Port Arthur" P.O.Box 1089 X Port Arthur,Texas 77641-1089 X 409.983.8101 X FAX 409.982.6743 City of r�rt rthu � Texas www.PortArthurTx.gov Recommendation: Staff recommends that the City Council approve the resolution authorizing the City Manager to purchase two (2) Pierce Type I fire engines from Siddons-Martin Emergency Group of Denton, Texas, through the Texas BuyBoard Cooperative Purchasing Program, in the total amount of $1,798,272.00, with funding available in the FY 2026-2027 Capital Improvement Fund, Account Number 625-19-047-8522-00-10-00. "Remember,we are here to serve the Citizens of Port Arthur" P.O.Box 1089 X Port Arthur,Texas 77641-1089 X 409.983.8101 X FAX 409.982.6743 P.R.No. 25265 11/17/2026 aom-tnr RESOLUTION NO. A RESOLUTION AUTHORIZING THE CITY MANAGER TO PURCHASE TWO (2) PIERCE TYPE I FIRE ENGINES FOR THE CITY OF PORT ARTHUR FIRE DEPARTMENT FROM SIDDONS-MARTIN EMERGENCY GROUP OF DENTON, TEXAS, THROUGH THE TEXAS BUYBOARD COOPERATIVE PURCHASING PROGRAM, IN THE TOTAL AMOUNT OF $1,798,272.00; AND PROVIDING FOR FUNDING FROM THE FY 2026-2027 CAPITAL IMPROVEMENT FUND, ACCOUNT NUMBER 625-19-047- 8522-00-10-00. WHEREAS, the City of Port Arthur Fire Department has identified the need to acquire two (2) Type I fire engines to address critical fleet replacement needs, maintain operational readiness, and ensure the continued delivery of effective fire suppression and emergency response services; and WHEREAS,the Fire Department has determined that the existing fire apparatus requiring replacement has reached the end of its useful frontline service life and is scheduled for retirement from frontline service and/or disposition through public auction; and WHEREAS, the Fire Department, in coordination with the Finance Department, has evaluated available procurement options and determined that the acquisition of two (2) standardized, non-custom Pierce Type I fire engines through the Texas BuyBoard Cooperative Purchasing Program represents a cost-effective and fiscally responsible approach to addressing the City's immediate apparatus replacement needs; and WHEREAS, although the Fire Depaitiuent has historically utilized custom-built fire apparatus to accommodate the Department's operational demands, current municipal financial considerations warrant the acquisition of standardized, pre-engineered apparatus that will satisfy the Department's essential operational requirements while reducing the financial burden associated with custom-built equipment; and WHEREAS, the proposed acquisition is expected to generate approximately $1,600,000.00 in savings compared to the anticipated cost of comparable custom-built apparatus and provides an estimated delivery timeframe of March 2027, thereby substantially reducing the extended procurement and delivery delays, which may otherwise range from four (4) to five (5) years for custom-built fire engines; and WHEREAS,the acquisition of standardized fire apparatus will promote fleet consistency, facilitate personnel familiarity and cross-training, simplify parts procurement,reduce maintenance and repair delays, and improve the Department's ability to maintain reliable frontline emergency response capabilities; and P.R. No. 25265 11/17/2026 aom-tnr WHEREAS, notwithstanding the Department's preference for custom-built apparatus to address its substantial call volume, demanding operational workload, and unique service requirements, the proposed acquisition represents a prudent interim procurement strategy that balances the Department's operational needs with the City's current fiscal considerations, without compromising the City's commitment to public safety; and WHEREAS, the Department anticipates returning to the acquisition of custom-built fire apparatus when the City's financial position permits, while recognizing that the proposed standardized apparatus will provide the necessary frontline response capabilities in the interim; and WHEREAS, Chapter 271 of the Texas Local Government Code authorizes local governments to participate in cooperative purchasing programs through interlocal agreements, permitting the acquisition of goods and services through competitively awarded cooperative P g q contracts in lieu of conducting a separate competitive procurement, provided the applicable statutory requirements are satisfied; and WHEREAS, pursuant to Resolution No. 02-341, the City of Port Arthur entered into an interlocal agreement authorizing its participation in the Texas BuyBoard Cooperative Purchasing Program; and WHEREAS, Siddons-Martin Emergency Group, of Denton, Texas, is an authorized vendor under the applicable BuyBoard cooperative purchasing contract,and the proposed purchase is supported by the contract pricing documentation attached hereto as Exhibit A; and WHEREAS, the Fire Department recommends that the City Council authorize the City Manager to execute the necessary purchase documentation and complete the acquisition of two(2) Pierce Type I fire engines from Siddons-Martin Emergency Group in the total amount of $1,798,272.00; and WHEREAS, sufficient funds for this acquisition are budgeted and available in the FY 2026-2027 Capital Improvement Fund, Account Number 625-19-047-8522-00-10-00; and WHEREAS, the City Council finds that authorizing this purchase is in the best interest of the City and its residents because it will address critical fire apparatus replacement needs, strengthen emergency response capabilities, and promote the responsible expenditure of public funds. NOW THEREFORE,BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PORT ARTHUR,TEXAS: Section 1. That the facts and opinions in the preamble are true and correct. Section 2. The City Manager is hereby authorized to execute the necessary purchase documents and take all actions reasonably necessary to purchase two(2)Pierce Type I fire engines P.R.No. 25265 11/17/2026 aom- tnr for the City of Port Arthur Fire Department from Siddons-Martin Emergency Group of Denton, Texas, through the Texas BuyBoard Cooperative Purchasing Program, in the total amount not to exceed$1,798,272.00. Section 3. The purchase authorized herein shall be funded from the FY 2026-2027 Capital Improvement Fund, Account Number 625-19-047-8522-00-10-00, subject to the availability and proper appropriation of funds. Section 4. That a copy of the caption of this resolution shall be spread upon the Minutes of the City Council. READ, ADOPTED AND APPROVED on this day of November, A.D., 2026, at a Regular Meeting of the City Council of the City of Port Arthur, Texas, by the following vote: AYES: Mayor: Councilmembers: NOES: Charlotte M. Moses Mayor ATTEST: Christe Whitley Ned, City Secretary P.R. No. 25265 11/17/2026 aom- tnr APPROVED AS TO FORM: Roxann Pais Cotroneo, City Attorney APPROVED FOR ADMINISTRATION: ;7,7 y / / el:/ t(M1/1444&(_--4:747 IC44 16 Antonio Mitchell, Intenm Fire Chief ek v ‘ ►,c. Ron Burton, ity Manager APPROVED AS TO AVAILABILITY OF FUNDS: oOpLyn oswe 1 FinancrereV , 6/441QL‘ Clifton Williams, CPPB Purchasing Manager P.R.No. 25265 11/17/2026 aom- tnr EXHIBIT A Siddons-Martin Emergency Group, LLC 1506 Interstate 35 W Denton,TX 76207-2402 GDN P115891 TxDMV Dealer License No. A173067 rjr 1 November 04, 2026 �u j`J�` ����nl rj EMEMMENtlegf &'eup Antonio Mitchel, Deputy Chief CITY OF PORT ARTHUR P.O. BOX 1089, PORT ARTHUR,TX 77641 Proposal For:2026 Port Arthur Saber Pumpers Siddons-Martin Emergency Group, LLC, is pleased to provide the following proposal to CITY OF PORT ARTHUR. Unit(s)will comply with all specifications attached and made a part of this proposal. Total price includes delivery FOB and training on the operation and use of the apparatus. Description Amount Qty. 1- 46171-Pierce-Custom -Saber FR-Pumper,2nd Gen Unit Price -$898,136.00 Delivery within 6-9 months of ordered date Quote- 0013187 -0 Vehicle Price $898,136.00 46171—Unit Total $898,136.00 Qty. 1- 46169-Pierce-Custom -Saber FR-Pumper,2nd Gen Unit Price-$898,136.00 Delivery within 6-9 months of ordered date Quote-0013185- 2 Vehicle Price $898,136.00 46169—Unit Total $898,136.00 008201 Page 1 of 4 November 04, 2026 Subtotal $1,796,272.00 HGAC FS12-23 (FIRE) $2,000.00 Total $1,798,272.00 Price guaranteed until 11/06/2026. Prepayment Discount:To receive the prepayment discount(s), if quoted, above, the Customer must pay the applicable prepayment invoice in full within forty-five (45) days of the invoice date, unless otherwise agreed in writing by Siddons-Martin Emergency Group, Additional: Pricing is valid for stock Saber pumpers,job 46171 and 46169, which are identical pumpers. These are Pierce stock units and are sold on a first come, first serve basis. A signed Proposal Letter or PO is needed in order to claim either of these. Taxes:Tax is not included in this proposal. If the purchasing organization is not exempt from sales tax or any other applicable taxes and/or the proposed apparatus does not qualify for exempt status, it is the duty of the purchasing organization to pay any and all taxes due. Balance of sale price is due upon acceptance of the apparatus at the factory. Payment Terms: Unless otherwise specifically noted and agreed upon in writing by Siddons-Martin Emergency Group, all invoices are net due upon delivery and acceptance of the apparatus. Any alternate payment terms must be expressly approved in advance and documented in a signed agreement or purchase order executed by both parties. Payments not received when due shall be subject to the late fee provisions stated below, accruing from the date payment was due until paid in full. Siddons-Martin Emergency Group reserves the right to delay delivery, withhold release of title or documentation, or impose additional charges if agreed payment terms are not met. Title and ownership of the apparatus shall not transfer to the Customer until full payment has been received by Siddons-Martin Emergency Group. If the apparatus and any associated loose equipment, poly components, or upfitting items are purchased under a single purchase order, Siddons-Martin Emergency Group will invoice for the total purchase price upon Customer's acceptance of the apparatus, excluding any ancillary, incidental, or non-essential outstanding items. For purposes of this Agreement, "outstanding items" may include, without limitation, loose equipment, accessories, minor apparatus upfitting, punch-list items, or post-delivery buildout components that do not materially impair the Apparatus's intended operational use. If Customer requests delivery of loose equipment, poly components, or upfitting items prior to delivery of the apparatus, Siddons-Martin Emergency Group may condition such early delivery on advance payment of the total purchase price or written confirmation that such payment has been authorized by Customer. 008201 Page 2 of 4 November 04, 2026 Late Fee: A late fee of.033%of the sale price will be charged per day for overdue payments beginning ten (10) days after the payment is due. After 30 days, the late fee increases to .044% per day until the payment is received. Cancellation: In the event this proposal is accepted then cancelled or terminated by the Customer before completion of the order (meaning before final acceptance, delivery, and payment in full for the apparatus), Siddons-Martin Emergency Group may assess a cancellation fee as liquidated damages to recover costs incurred. All cancellations must be submitted in writing and signed by an authorized representative of the Customer. The following schedule will be applied based on the stage of completion at the time of cancellation: (A) 10% of the Purchase Price after the order is accepted and entered by the manufacturer; (B) 20%of the Purchase Price after completion of preliminary engineering drawings prepared for Customer review ("Approval Drawings"), whether or not the Customer has yet approved such drawings; (C) 30%of the Purchase Price upon any material requisition or the start of production. (D) If cancellation occurs after the apparatus has entered the production process, the Customer will be responsible for the difference between the Purchase Price and any resale price obtained by Siddons-Martin Emergency Group, plus any costs incurred by Siddons-Martin Emergency Group to conduct such resale. Siddons-Martin Emergency Group will make reasonable efforts to mitigate such costs through resale to another purchaser. For purposes of this section, "Purchase Price" means the total sale price of the apparatus, exclusive of taxes and any approved change order items not yet invoiced. The cancellation fee will increase accordingly as costs are incurred through engineering, materials procurement, or manufacturing. invoices for cancellation fees are due within thirty (30) days of issuance. Any unpaid balance thereafter will accrue interest or late fees at the same rates and in the same manner as provided under the Late Fee section of this proposal. Persistent Inflationary Environment Notification: If the Producer Price Index of Components for Manufacturing [www.bls.gov Series ID: WPUID6112] (the "PPI") has increased at a compounded annual growth rate greater than 5.0%from the date of acceptance of this proposal letter(the "Order Month") and 14 months prior to the anticipated Ready for Pickup Date (the "Evaluation Month"), then the proposal price may be increased by an amount equal to any increase exceeding 5.0%for the time period between the Order Month and the Evaluation Month. Siddons-Martin Emergency Group and Pierce Manufacturing will provide documentation of such an increase and the updated price for the customer's approval before proceeding with completion of the order along with an option to cancel the order. Due to global supply chain constraints, any delivery date contained herein is a good faith estimate as of the date of this order/contract. Delivery updates will be made available, and a final delivery date will be provided as soon as possible. Force Majeure: Siddons-Martin Emergency Group shall not be liable for any failure or delay in the performance of its obligations if such failure or delay is due to causes beyond its reasonable control, including but not limited to acts of God, war, natural disasters, armed conflicts, acts of terrorism, 008201 Page 3 of 4 November G4, 2026 labor disruptions, supply chain disruptions, governmental mandates, or any other events that are unforeseeable and unavoidable by Siddons-Martin Emergency Group. Should Siddons-Martin Emergency Group encounter such force majeure event, it shall promptly notify Customer in writing and shall use all reasonable efforts to mitigate the effects of the force majeure event and resume the performance of its obligations as soon as practicable. Purchase price may be subject to new or increased tariffs, duties, taxes, or other governmental charges levied against, or made applicable to, the vehicle or any component thereof after the date of this proposal. Should such fees be enacted prior to order completion, Siddons-Martin Emergency Group reserves the right to revise the final cost to reflect the additional fees and will provide notice of any such adjustment. Acceptance:To ensure the above stated terms and conditions are understood and adhered to, Siddons-Martin Emergency Group, LLC requires an authorized individual from the purchasing organization sign and date this proposal and include it with any purchase order. Upon signing of this proposal, the terms and conditions stated herein will be considered binding and accepted by the Customer. The terms and acceptance of this proposal will be governed by the laws of the State of Texas. No additional terms or conditions will be binding upon Siddons-Martin Emergency Group, LLC unless agreed to in writing and signed by a duly authorized officer of Siddons-Martin Emergency Group, LLC. Fria nCf I, I � �"�r() , the authorizednrepresentative of CITY OF PORT ARTHUR, agree to purchase the proposed and agree to the terms of this proposal and the specifications attached hereto. Customer Authorized Representative/y/i0076 Sales Representative C7 P dawyt, 11/4/26 ig ature and Date Signature and Date V.uiYi Q't a/ €:6 �l '798afiay68 008201 Page 4 of 4 November 04, 2026 ir pt@v Fire and Rescue Apparatus One (1) Year Material and Workmanship Basic Apparatus Limited Warranty 1.LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the Buyer: (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions, drivelines,axles,water pumps and generators;with respect to all such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable warranties,if any,made by the respective manufacturers thereof; Portions of the apparatus manufactured by Pierce shall be (b)any vehicle,chassis,or component,part,attachment or accessory damaged by Coverage: free from defects in material and workmanship misuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic environment,improper maintenance,accident,crash,or force majeure such as natural disaster,lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been repaired,altered or assembled in any way by any person or entity other than Pierce Warranty Begins: The date the apparatus is placed in service,or 60 days from which,in the sole judgment of Pierce,adversely affects the performance,stability or the original buyer Invoice date,whichever comes first purpose for which it was manufactured;or (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Twelve(12)months. during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced(a)without prior written approval of the Pierce Customer Service Department;or(b)at a facility which has not been approved by Pierce as to technical capability. Any repairs,modifications,alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty. 2.DISCLAIMERS OF WARRANTIES THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. 3.BUYER'S EXCLUSIVE REMEDY. Conditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: period,and such nonconformity is not due to misuse,neglect,accident or improper No specific exclusions apply maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also and shall make the product available for inspection by Pierce or its designated agent.At Paragraphs the request of Pierce,any allegedly defective product shall be returned to Pierce by 2 thru 4 Buyer for examination and/or repair.Buyer shall be responsible for the cost of such transportation,and for risk of loss of or damage to the product during transportation. Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) any nonconforming or defective parts.Repair or replacement shall be made only by a facility approved in advance in writing by Pierce.THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL,SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER, WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the foregoing,Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages,penalties, with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues,loss of vehicles or products or any associated normal to the particular model.Normal service means service which does not subject the equipment,cost of substitute vehicles or products,down-time,delay damages,any other product to stresses or impacts greater than normally result from careful use.If the Buyer types of economic loss,or for any claims by any third party for any such damages. discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surely Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if any) or to the warranties(if any)made by any manufacturer(other than Pierce)of any part, component,attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0008 Cummins Warranty Worldwide Fire Apparatus/Crash Trucks .33 Coverage Owner Products Warranted Responsibilities This Warranty applies to new diesel Engines sold by Cummins and delivered to the first user on or after Owner is responsible for the operation and April 1, 2007, that are used in fire apparatus truck and maintenance of the Engine as specified in Cummins crash truck* applications Worldwide. Operation and Maintenance Manuals. Owner is also Base Engine Warranty responsible for providing proof that all recommended of the maintenance has been performed. failures The Base Engine Warranty covers any Engine which result, under normal use and service, Before the expiration of the applicable Warranty, from a defect in material or factory workmanship Owner must notify a Cummins distributor, authorized (Warrantable Failure). This Coverage begins with the dealer or other repair location approved by Cummins sale of the Engine by Cummins and ends five years or of any Warrantable Failure and make the Engine 100,000 miles (160,935 kilometers), whichever occurs available for repair by such facility. Except for Engines first, after the date of delivery of the Engine to the first disabled by a Warrantable Failure, Owner must also user. deliver the Engine to the repair facility. Engine aftertreatment components included in the Service locations are listed on the Cummins Worldwide Cummins Critical Parts List (CPL) and marked with a Service Locator at cummins.com. Cummins part number are covered under Base Engine Owner is responsible for the cost of lubricating oil, Warranty. antifreeze, filter elements and other maintenance items Additional Coverage is outlined in the Emission provided during Warranty repairs unless such items Warranty section. are not reusable due to the Warrantable Failure. These Warranties are made to all Owners in the Owner is responsible for communication expenses, chain of distribution and Coverage continues to all meals, lodging and similar costs incurred as a result of subsequent Owners until the end of the periods of a Warrantable Failure. Coverage. Owner is responsible for non-Engine repairs and for "downtime" expenses, cargo damage, fines, all , Cummins applicable taxes, all business costs and other losses resulting from a Warrantable Failure. Responsibilities Owner is responsible for a $100 (U.S. Dollars) deductible per each service visit under this plan in the 3rd, 4th and 5th years of Base Engine Warranty. The Cummins will pay for all parts and labor needed to deductible will not be charged during the first 2 years repair the damage to the Engine resulting from a of the Base Engine Warranty. Warrantable Failure.Cummins will pay for the lubricating oil, antifreeze, I....i m i tat i o n s filter elements, belts, hoses and other maintenance items that are not reusable due to the Warrantable Cummins is not responsible for failures or damage Failure. resulting from what Cummins determines to be abuse Cummins will pay for reasonable labor costs for or neglect, including, but not limited to: operation Engine removal and reinstallation when necessary to without adequate coolants or lubricants; overfueling; repair a Warrantable Failure. overspeeding; lack of maintenance of lubricating, Cummins will pay reasonable costs for towing a cooling or intake systems; improper storage, starting, vehicle disabled by a Warrantable Failure to the warm-up, run-in or shutdown practices; unauthorized nearest authorized repair location. In lieu of the towing modifications of the Engine. expense, Cummins will pay reasonable costs for Any unauthorized modifications to the aftertreatment mechanics to travel to and from the location of the could negatively effect emissions certification and void vehicle, including meals, mileage and lodging when Warranty. the repair is performed at the site of the failure. Cummins is also not responsible for failures caused by incorrect oil, fuel or diesel exhaust fluid or by water, dirt or other contaminants in the fuel, oil or diesel exhaust fluid. ErnIssIon This Warranty does not apply to accessories supplied by Cummins which bear the name of another company. Such non-warranted accessories include, but V\/arranty are not limited to: alternators, starters, fans, air conditioning compressors, clutches, filters, transmissions, torque converters, vacuum pumps, Products Warranted power steering pumps, fan drives and air compressors. This Emission Warranty applies to new Engines Cummins branded alternators and starters are covered marketed by Cummins that are used in the United for the first two years from the date of delivery of the States" in vehicles designed for transporting persons Engine to the first user, or the expiration of the Base or property on a street or highway. This Warranty Engine Warranty, whichever occurs first. applies to Engines delivered to the first user on or after Failures resulting in excessive oil consumption are not September 1, 1992. covered beyond the duration of the Coverage or Coverage 100,000 miles (160,935 kilometers) or 7,000 hours from the date of delivery of the Engine to the first user, Cummins warrants to the first user and each whichever of the three occurs first. Before a claim for subsequent purchaser that the Engine is designed, excessive oil consumption will be considered, Owner built and equipped so as to conform at the time of sale must submit adequate documentation to show that by Cummins with all U.S. federal emission regulations consumption exceeds Cummins published standards. applicable at the time of manufacture and that it is free from defects in material or factory workmanship which Failures of belts and hoses supplied by Cummins are would cause it not to meet these regulations within the not covered beyond the first year from the date of longer of the following periods: (A) Five years or delivery of the Engine to the first user or the duration 100,000 miles (160,935 kilometers) of operation, of the Warranty, whichever occurs first. whichever occurs first, as measured from the date of Parts used to repair a Warrantable Failure may be new delivery of the Engine to the first user or (B) The Base Cummins parts, Cummins approved rebuilt parts or Engine Warranty. repaired parts. Cummins is not responsible for failures If the vehicle in which the Engine is installed is resulting from the use of parts not approved by registered in the state of California, a separate Cummins. California Emission Warranty also applies. A new Cummins or Cummins approved rebuilt part Limitations used to repair a Warrantable Failure assumes the identity of the part it replaced and is entitled to the Failures, other than those resulting from defects in remaining Coverage hereunder. material or factory workmanship, are not covered by Cummins Inc. reserves the right to interrogate this Warranty. Electronic Control Module (ECM) data for purposes of Cummins is not responsible for failures or damage failure analysis. resulting from what Cummins determines to be abuse CUMMINS DOES NOT COVER WEAR OR WEAROUT or neglect, including, but not limited to: operation OF COVERED PARTS. without adequate coolants or lubricants; overfueling; overspeeding; lack of maintenance of lubricating, CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL cooling or intake systems; improper storage, starting, OR CONSEQUENTIAL DAMAGES. warm-up, run-in or shutdown practices; unauthorized THIS WARRANTY AND THE EMISSION WARRANTY modifications of the Engine. SET FORTH HEREINAFTER ARE THE SOLE Any unauthorized modifications to the aftertreatment WARRANTIES MADE BY CUMMINS IN REGARD TO could negatively effect emissions certification and void THESE ENGINES. CUMMINS MAKES NO OTHER Warranty. WARRANTIES, EXPRESS OR IMPLIED, OR OF Cummins is also not responsible for failures caused by MERCHANTABILITY OR FITNESS FOR A incorrect oil, fuel or diesel exhaust fluid or by water, PARTICULAR PURPOSE. dirt or other contaminants in the fuel, oil or diesel This Warranty gives you specific legal rights, and you exhaust fluid. may also have other rights which vary from state to Cummins is not responsible for non Engine repairs, state. "downtime" expenses, cargo damage, fines, all applicable taxes, all business costs or other losses resulting from a Warrantable Failure. CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. * Airport operated crash trucks and fire department operated trucks employed to respond to fires, hazardous material releases, rescue and other emergency-type situations. ** United States includes American Samoa, the Commonwealth of Northern Mariana Islands, Guam, Puerto Rico and the U.S. Virgin Islands. o Cummins Inc. Box 3005 Columbus,IN 47202-3005 U.S.A. Bulletin 3381161 Printed in U.S.A.Rev.08/09 ©2001 Cummins Inc. -) 0 TRW COMMERCIAL STEERING SYSTEMS / /IVW 800 HEATH STREET • (✓ LAFAYETTE,INDIANA 47904 1 PRODUCT WARRANTY v UG I. WARRANTY: The Commercial Steering Systems group of TRW,Inc.,hereinafter referred to as"CSS",warrants that each new product supplied by CSS to its customer,when properly installed,used and maintained,shall be free from defect in material and 11 workmanship for the period specified below: U ,0 (A) CSS Product installed in New On-highway Motor Vehicle 0 C) i Within twelve(12)months after date of delivery of such vehicle to the original retail purchaser,or before such vehicle has been L driven one hundred thousand(100,000)miles,whichever event shall first occur. J 1 (B) CSS Product installed in New Agricultural,Turf,Industrial,or Construction Vehicles and Related Equipment C Within twelve(12)months after date of delivery of such vehicle/equipment to the original retail purchaser or before such 1 vehicle/equipment has been operated for two thousand(2000)hours or fifty thousand(50,000)miles,whichever occurs first. c i (C) CSS Product installed in New End Product,Not Specifically Mentioned in Classifications(A)or(B)Above and All Other Off-Highway/Severe Applications 3 U Within six(6)months after date of delivery of the original equipment manufacturer's end product to the original retail purchaser. C,) II. REMEDY: Customer's sole remedy under the foregoing warranty is limited to correction by means of repair,replacement or issuance of credit,at the option of CSS,of any product which is: J (A) Returned to CSS within the specified warranty time period,with prior notice to,and the written consent of,CSS,with i t transportation and handling charges prepaid,together with a statement describing the alleged defect,the part number,model C) number and application,and mileage or hours of use of such product;and (B) Upon examination,determined by CSS not to conform to the warranty. Cl q III. Any product which is repaired or replaced under this warranty will be returned to customer prepaid. Disposition of any product determined not to be covered by this warranty will be at the customer's expense. J U L IV. CSS will not be liable for any repairs,replacements,or adjustments to any product or any cost of labor performed by or at the request of customer without the express prior written consent of CSS. V. EXCEPTIONS: The provision of this warranty shall not apply to any CSS product which is used for a purpose for which it is not , Cl designed,or which shall have been repaired or altered in any way,or which has been subject to misuse,negligence or accident, ' 0 neglect of normal maintenance services,so as,in the judgement of CSS to adversely affect its performance and reliability. In no case will the CSS warranty exceed the standard published warranty of its customer in terms of time and/or distance. In all events,the CSS warranty will expire thirty(30)months after the date of manufacture as stamped on the Product. In the case of hydraulic equipment, Voperation with unapproved fluid or temperatures voids this warranty. uv VI. EXCLUSION OF ALL OTHER REMEDIES AND LIMITATION OF LIABILITY: Customer's sole and exclusive remedy under the n foregoing warranty shall be for the repair,replacement or issuance of credit with respect to a defective product,as set forth and described above. Other provisions hereof notwithstanding,CSS shall not be liable to Customer,or any successor in interest, C, beneficiary or assignee of Customer,based upon any claim against CSS,whether in contract,warranty,negligence,strict liability, 0 _ 1 C`, indemnity or otherwise,for any special,consequential,incidental or other damages relating in any way to the design,manufacture, n sale,installation or other use of any product purchased from CSS. f 0 U VII. EXCLUSION OF ALL OTHER WARRANTIES: THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY BY CSS AND IS 1 IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND REPRESENTATIONS,WHETHER ORAL,WRITTEN,EX- - PRESSED,IMPLIED OR STATUTORY,INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. L TRW COMMERCIAL STEERING SYSTEMS Revised November2001 1 pte,icea __ Fire and Rescue Apparatus 0. Lifetime Fifty (50) Year Structural Integrity Custom Chassis Frame 1.LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the purchaser who first puts the product in service("Buyer"): (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions, drivelines,axles,water pumps and generators;with respect to all such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable warranties,if any,made by the respective manufacturers thereof; (b)any vehicle,chassis,or component,part,attachment or accessory damaged by Custom chassis frame rail manufactured by Pierce shall be misuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic Coverage: free from defects in material and workmanship environment,improper maintenance,accident,crash,or force majeure such as natural disaster,lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been repaired,altered or assembled in any way by any person or entity other than Pierce which,in the sole judgment of Pierce,adversely affects the performance,stability or purpose for which it was manufactured;or Warranty Begins: The date of the original purchase invoice(issued when the product ships from the factory). (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Fifty(50)Years during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: (Expected Life of Apparatus) bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced(a)without prior written approval of the Pierce Customer Service Department;or(b)at a facility which has not been approved by Pierce as to technical capability.Any repairs,modifications,alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty. 2.DISCLAIMERS OF WARRANTIES THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. 3.BUYER'S EXCLUSIVE REMEDY. Conditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: This warranty applies to the frame rails only,crossmembers period,and such nonconformity is not due to misuse,neglect,accident or improper are excluded. maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also This warranty does not apply to damage caused by corrosion. and shall make the product available for inspection by Pierce or its designated agent.At Paragraphs the request of Pierce,any allegedly defective product shall be retumed to Pierce by 2 thru 4 Buyer for examination and/or repair.Buyer shall be responsible for the cost of such transportation,and for risk of loss of or damage to the product during transportation. Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) any nonconforming or defective parts.Repair or replacement shall be made only by a facility approved in advance in wilting by Pierce.THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL,SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER, WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the foregoing,Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages,penalties, with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues,loss of vehicles or products or any associated normal to the particular model.Normal service means service which does not subject the equipment,cost of substitute vehicles or products,down-time,delay damages,any other product to stresses or impacts greater than normally result from careful use.If the Buyer types of economic loss,or for any claims by any third party for any such damages. discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surety Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if any) or to the warranties(if any)made by any manufacturer(other than Pierce)of any part, component,attachment or accessory that is incorporated into or attached to the vehicle. 12/10/2024 WA0013 Dana Holding Corporation DANA Commercial Vehicle Products Group Grace Lake Corporate Center 1 Village Center Drive Van Buren Township,Michigan 48111 www.dana.com New for 2011! Dana Holding Corporation is pleased to announce a change in our standard warranty for fire/rescue vehicles. All steer and drive axles will now come with a 5 year / 100,000 mile warranty. For further information, please go to www.roadranger.com. Dana Holding Corporation is working with chassis manufactures to supply a 24K front steer beam with a 5 W drop. We have listened to your requests for a slightly higher GAWR for single axle aerials. Not all fire stations can accommodate a long wheel base application. This allows manufactures to meet the limited length requirements for smaller fire houses. Please submit your requests through our website. Please indicate on the application your need for 24K GAWR. Finally, our drive axles will accommodate simultaneous auxiliary braking. Dana axles are built tough and were design with Telma retarders in mind. Submit your application for single or tandem designation. Dana Holding Corporation will work with you to provide the best drive train solution with the best warranty in the fire/rescue industry. For additional information please contact: Alan Manzon Account Manager - Specialty Markets Dana Holding Corporation One Village Center Dr. Van Buren Twp. , MI 48111-5711 Phone: (734) 629-1141 Cell: (269)312-3220 Alan.manzon@dana.com Fire and Rescue Apparatus Three (3) Year Material and Workmanship Meritor Wabco ABS Brake System Limited Warranty 1.LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the Buyer. (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions, drivelines,axles,water pumps and generators;with respect to ah such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable warranties,if any,made by the respective manufacturers thereof; The Meritor Wabco ABS brake system shall be covered by Coverage: Meritor Wabco as indicated in the attached Meritor Wabco (b)any vehicle,chassis,or component,part,attachment or accessory damaged by warranty coverage description misuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic environment,improper maintenance,accident,crash,or force majeure such as natural disaster,lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been repaired,altered or assembled in any way by any person or entity other than Pierce The date of the original purchase invoice(issued when the which,in the sole judgment of Pierce,adversely affects the performance,stability or Warranty Begins: product ships from the factory).p purpose for which it was manufactured;or (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Three(3)Year during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced(a)without prior written approval of the Pierce Customer Service Department;or(b)at a facility which has not been approved by Pierce as to technical capability. Any repairs,modifications,alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty. 2.DISCLAIMERS OF WARRANTIES THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. 3.BUYER'S EXCLUSIVE REMEDY. Conditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: period,and such nonconformity is not due to misuse,neglect,accident or improper The exclusions listed in the attached Meritor Wabco warranty maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also description shall apply. and shah make the product available for inspection by Pierce or its designated agent.At Paragraphs the request of Pierce,any allegedly defective product shall be returned to Pierce by 2 thru 4 Buyer for examination and/or repair.Buyer shall be responsible for the cost of such transportation,and for risk of loss of or damage to the product during transportation. Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) any nonconforming or defective parts.Repair or replacement shall be made only by a facility approved in advance in writing by Pierce.THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL,SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER, WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the This limited warranty shall apply only if the product is properly maintained in accordance foregoing,Pierce specifically disclaims any liability for property or personal injury with Pierce's maintenance instructions and manuals and is used in service which is damages,penalties,damages for lost profits or revenues,loss of vehicles or products or normal to the particular model.Normal service means service which does not subject the any associated equipment,cost of substitute vehicles or products,down-time,delay product to stresses or impacts greater than normally result from careful use.If the Buyer damages,any other types of economic loss,or for any claims by any third party for any discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days such damages. after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surety Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if any)or to the warranties(if any)made by any manufacturer(other than Pierce)of any part,component,attachment or accessory that is incorporated into or attached to the vehicle. 2/25/2013 WA0232 WARRANTY MODEL YEAR 2021 VEHICLES A11111111 ,.... w+yam _ n .. K,. - 1 -_..r_ _ yy a ..- ,,,.„ . ,... .,........,,,..,,,,, _: , v t i�iR Y Y k ,_ ‘ . I� _ .. n:}1,,,,,,,t, ,. tl:.}�Ycy' -:if _ ...,vim. a ec '1; '''''''';' . .'''''.6:,''' fx I ', 4 N. ,: x . Warranty coverage is essential to protecting your investment,But understanding the full details of your coverage can be challenging.This straightforward approach allows you,our valued customer,to better understand how your specific vehicle applications will be covered in your region.Our component warranty coverage is provided according to vocation/usage categories listed below. • Linehaul covers high mileage operation(over 60.000 miles/year)on well-maintained major highways of concrete or asphalt construction. •General Service covers moderate mileage operations(less than 60,000 miles/year)on well-maintained public roads(less than 10 percent off-road)typically with less than three(3)stops per mile. •Heavy Service(Vocational)covers vehicles with more than 10 percent off-road OR moderate to frequent starts/stops typically with more than three(3)stops per mile. •Off-Highway Service covers lower mileage operations.Vehicles are not typically licensed for highway use. How to Read Warranty Coverage (Example) Number of Years Mileage(in thousands)Unl=Unlimited P=Parts Only P&L=Parts&Labor 300 •The standard aftermarket warranty for WABCO products -including WABCO Original parts,WABCO Rernan Solutions. ProVia quality attermarket parts and WABCO retrofit solutions-is one year, parts only from in-service date when purchased from. F i t bi for networks or its affiliates and/or subsidiaries. wABCO WARRANTY - MODEL YEAR 2021 VEHICLES LINEHAUL/GENERAL SERVICE WARRANTY INFORMATION LINEHAULJGENERAL SERVICE VEHICLES •Aerial Ladder Truk • Flatbed •Livestock Hauler •Refrigerated Freight •Aerial Platform • Front Engine Commercial • Meat Packer •School Bus •Ambulance Chassis • Moving Van • Stake Truck •Auto Hauler • Front Engine Integral •Municipal Truck •Tanker • Beverage Truck Coach • Pipe Hauler •Tanker Truck • Bulk Hauler •General Freight • Platform Auto Hauler •Triples •Chip Hauler(Truck) •Grain Hauler •Pumper •Tour Bus •Cross Country Coach • Intercity Coach • Rear Engine Integral Coach •Wrecker • Doubles • Intermodal Chassis • Recreational Vehicles LINEHAUL TYPICALLY IS GENERAL SERVICE TYPICALLY IS • High mileage operation (over 60,000 miles/year) • Moderate mileage operations(less than 60,000 miles/year) •Well maintained major highways of concrete or •Well maintained public roads(less than 10%off-road) asphalt construction • Less than three(3)stops per mile WABCO Components' WABCO Components'(cunt-) Air Management Safety Air Brake Valves OnGuardACTIVE"' Trailer Lift Axle Control Valve 1/100/P&L On Lane" Trailer Control Line Filter' OnLaneALERT5 Air Compressors(ALL)2 2/200/P&L OnSide5 Air Dryers(ALL) 3/300/P&L Trailer SateStartTM Aerodynamics Trailer TailGUARDTM Telematics OptiFloe TrailerSkirt ThallerCASTTM Telematics Devoe 1100/P&L OptiFlow'Trailer Tail and AutoTail Wheel End Solutions Braking Systems EasyFitTM Slack Adjuster ABS Anti-Lock BrakingSy stems Air (Anti-Lock MAXXUSTm Truck Air Disc Brake 5/5 .-,- ABS(Anti-Lock Braking IVTM -Wheel Module 6 Electronic Braking Systen IVTM -All Otl-.- _' ducts Electronic Stability Conn _ . 3/300/P&L Pan 1'and 1 -.r Disc Bral<< nIiP and Unl/L Roll Stability Control(R'c- Pan 22 Air Disc Brake -„,P .r-' I ',- Trailer Roll Stability Supr. r RSS, TRISTCPT"' D Act. R Trailer ABS(Anti-Lock Braking Systeir TRIS Ac,t.z. : Driveline Suspension Control tJNISTOPTM Actuator -. Clutch Controls :::i2: .... Level no ;.Ives Trailer MA\'X22TTM Air Disc Brake ..P and 1 1/100/P&L OptiR - - anated Manual Transmission(AMT) OptiRide=Electronically Controlled Air Suspension 3l300iP&L (ECAS) 1 ZF and vVABCO branded components.-WABCO compressors installed on Cummins,Mercedes,and DDC engines are not warranted or serviced by ZF.Please contact your respective dealer/distributor of those engines for warranty and servicing.'An extended warranty of 4/400/P will apple when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve. HEAVY SERVICE (VOCATIONAL) WARRANTY INFORMATION HEAVY SERVICE VEHICLES WABCO Components' •;`airport Rescue Fire(ARF) •Michigan Special Air Management •Airport Shuttle Steel Hauler •Asphalt Truck • Michigan Special Air Brake Valves • Block Truck Waste Vehicle Ts oopressors(ALL)2 • Bottom Dump Trailer • Municipal Dump ii,r,ers ALL Combination • Newspaper Delivery •Cementing Vehicle • Package DeliveryTrailer Control Line Filter' • City Bus • Pick-up and Delivery Braking Systems •Commercial Pick-Up • Rapid Intervention ABS(Anti-Lock Braking System)Air '3/300/P&L •Concrete Pumper Vehicle(RIV) • Construction Material Hauler • Rear Loader ABS Anti-Lock Braking System)Hydraulic _ _"=!%P&L •Crash Fire Rescue(CFR) • Recycling Truck Electronic Braking System(EBS) • Mixer •Residential Pick-Up/Waste Electronic Stability Control+ES • Demolition • Rigging Truck T;ailr live' 300/P&L • Drill Rig • Roll-Off • Dump •Scrap Truck Roll Stcr; tral(RSS) • Emergency Service •Semi-End Dump Trailer Roil Stacility Support(ASS) • Equipment Hauling • Sewer Septic Vacuum Driveline Suspension Control • Flatbed Trailer Hauler •Shuttle Bus • Flatbed Truck •Side Loader OptiRide5"Electronically Controlled Air Suspension 2/200/P&L •Fracturing Truck a Snowplow/Snowblower (ECAS) • Front Loader •Steel Hauling Leveling Valves 1/100/P&L •Geophysical Exploration •Tanker Clutch Controls 2/200/P&L • Hopper Trailer Combinations •Tank Truck Safety • Landscaping Truck •Tractors with Pole Trailers • Liquid Waste Hauler •Tractor/Trailer with Jeeps OnGuardACTIVE® • Log Hauling •Transfer Dump OnLane= • Lowboy •Transfer Vehicle cOnLane`cE, • Michigan Special •Transit Bus 3/300/P&L Gravel Trains a Trolley On51 e • Michigan Special • Utility Truck Trailer SafeStartTM Log Hauler •Winch Truck Trailer TailGUARDTM Telematics HEAVY SERVICE TYPICALLY IS TrailerCASTTM Telematics Device 3/300/P&L •On/Off road vocations(10 ;r more off-road)OR Wheel End Solutions •Moderate to frequent starts crops typically more than three(3) EasyFitTM Slack Adjuster 2/200/F stops per mile M MA)C4IJS Air Disc Brake 1/Unl/P&L :. IVTM -Wheel Module 6/P r, 0: i —mu k IVTM -All Other Products Pan 22, 19 and 1'Air Disc Brake 1 Unl,P&L i • _ . Trailer MAXX22TTM TRISTOPTM D Actuator w/IBV sae • TRISTOP L Actuator ___ _ 1,,,,,„,„ UNISTOPT"-'Actuator 1_SF and WABCO branded components.2 WABCO compressors Installed on Cummins,Mercedes,and DDC engines are not warranted or serviced bv'F.Please contact your respective dealeridistributor of those engines for warranty and servicing.3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used In combination with a WABCO Trailer ABS valve. WARRANTY - MODEL YEAR 2021 VEHICLES INDUSTRIAL/OFF-HIGHWAY SERVICE WARRANTY INFORMATION INDUSTRIAL AND OFF-HIGHWAY SERVICE TYPICALLY IS WABCO Components' • L;. V r iireage iperat<,r Air Management •Vehicles are not typically licensed for highway use Air Brake Valves i Jra Compressors : _L)2 2/UnLP Market Common Application Types Air Dryers(ALL Fertilizer Spreader,Tractor,Heavy Duty Ag Agriculture Trailers,Harvester,Sprayer.Skid Loader,Silage Brake Actuation Bagger,Slurry Wagons,Grain Cart Air/Hydraulic --Lruators Pushback Tractor,Towing Tugs„Aircraft Master Cylinders Airport Support Tractor,Refueling Trucks,Food ServiceIr.—: F Baggage Tractors,De-Icing Equipment, Remote Actuators Runway Clearing Equipment Slave and Wheel Cylinders All-Terrain Crane,Rough Terrain Crane, Two Fluid Actuators Excavator,Compactor,Wheel Loader.Road Roller,Motor Grader,Articulated Dump Truck. Brake Locks Construction Rubber Tire Road Roller,Backhoe Loaders, Haul Trucks,Scraper Rough Terrain Forklift_;. Brake Locks(ALL) Trenchers,Drills Electric Brake Locks - Forestry Logging Forwarder,Kidder,Loaders,Yard Lever Locks Forklifts.Harvesters Fellers Braking Systems Port Tractor.Rail Yard Spotter,Stevedoring Tractor,Trailer Spotter,Yard Jockey.Scissor 2,ES(Anti-Lock Braking System)Air Material Har ,60`1 Lift,Straddle Carner,Manlift,Forklift,Boom Lift ABS(Anti-Lock Braking System)Hydraulic Telebandlers,Aerial Work Platforms Specialized Mining,Excavator,Haul Truck, Driveline Suspension Control Mining Underground Loader,Service Trucks,Wheel Clutch Controls Loaders.Scrapers,Load Haul Dumps, Leveling Valves Personnel Transports,Bolters,Scalers Street Sweeper,Utility Tractor.Utility Trucks. Electrohydraulics&Controls Municipal Tree Trimmers,Dump Trucks,Tow Trucks.Flat Electronic Pedals Bed Trucks.Winch Applications }ydraulic Brake Valves(EBV) 2,Unlil- Fracturing Trailer.Injecter Heads,Top Drives. Oil&Gas Jack/Litt Boats,Wireline Trucks,Load-On Pressure Switches Load-Off Hydraulic Braking Solutions Railcar Mover.Track Layers,Grinders,Plattr" Accumulator Charging Valves Rail Crane.Locomotive Railcars,Ballast Equipment. '� g ' Winch Applications Hydraulic Throttle Controls and Switches Modulating Brake Valves Wheel End Solutions EasyFitTM Slack Adjuster Caliper Disc Brakes MAO(USrM Air Disc Brake WII": � Multiple Disc Brakes ri. IVTM Wheel Module � �' y IVTM -All Other Products Pan 22. 19 and 17 Air Disc.Brake " - TRISTCPTM D Actuator w IBV TRISTOPTM D Actuator UNISTOPTM Actuator 1,'. 'EF and WAECO branded components.2 WABCO compressors installed on Cummins,Mercedes,and DDC engines are not warranted or ser.riced by:F.Please contact'your respective dealer.distributor of those engines ror warranty and servicing.3 Equivalent hours or service limit:2,000 hours ror all components. TERMS AND CONDITIONS COVERAGE EXCLUSIONS PRODUCT DESCRIPTION ABS, ELECTRONIC STABILITY CONTROL (ESC), ALL PRODUCTS ROLL STABILITY CONTROL (RSC), OPTIRIDE®, ONGUARD®AND ONLANE®, COLLECTIVELY This Warranty shall not apply tc the following, but not "ELECTRONICS" limited to: (1)damage to the product or its component parts caused by incorrect use, installation, maintenance or Failure of electronic components due too✓ervoltage repair, including without limitation (a) improper fit of mating condition, improper grounding, electrostatic discharge components or brackets, damaged threads, cut, broken, (ESD), improper shielding, electromagnetic interference chafed. pinched or otherwise damaged wiring (sensors, (EMI), or other wiring or installation issues. Malfunctions and harnesses and connectors), (b) sensors damaged during failure codes caused by other electronic subsystem failures removal when seized in block, or associated with sensor (data bus, engine, transmission, dashboard, etc.) adjustments/alignments, and (c) damage resulting from the use or installation of non-genuine WABCO components or HYDRAULIC COMPONENTS materials; (2) damage to the product, its component parts. For certain components, brake fluid DOTS or DOT4 is or diminished product or component part performance due used as the operating medium. Use of any other fluid will to incorrect operation, deviation from approved conditions void all warranties associated with that component. For or misapplication; (3) any unauthorized disassembly of the hydraulic braking applications the brake fluid is considered product or its component parts including without limitation a maintenance item. Maintenance intervals are listed in TB- (a)obliterated, defaced or missing WABCO or WABCO 1367. name plate, serial numbers or label identifying the device as a ZF product or WABCO component, (b) changes to sealed COVERAGE LIMITATIONS adjusting screws, and (c) opening or attempted repair of PRODUCT DESCRIPTION non-serviceable components; (4) malfunction of the component due to internal contamination of the ALL PRODUCTS vehicle system including without limitation (a)water and Any claim beyond 60 days from date of repair will not be other contamination damage that is due to the use of a accepted or honored under this warranty program. non-genuine air dryer cartridge or(b)valve failures due to contamination in air system, (5)complaints associated Products purchased on an incomplete vehicle (glider)are with noise, (6) damage resulting from corrosion (including limited to one year, 1/Unl/P. oxidation of electrical devices and connections). For vehicles that operate full- or part-time outside of the AIR DRYERS United States and Canada, a 1-Year/Unlimited Miles parts Mounting brackets(see vehicle OEM). Desiccant cartridge only(1 Unl/P)will apply. housing only. TOOLBOX PLUSTM DIAGNOSTIC SOFTWARE AIR SYSTEM COMPONENTS Proper diagnostics of WABCO Electronics may require the Normal wear items; Gladhand seals, dash valve knobs, latest version of TOOLBOX PLUST". Additional labor due to use of an outdated version of TOOLBOXTM software valve actuation handles, treadles, pedals. and/or the time to purchase or install the latest version of TOOLBOX PLUSTM are not covered under product warranty. WARRANTY - MODEL YEAR 2021 VEHICLES TERMS AND CONDITIONS (1) What is Covered by this Commercial Warranty? the OEM new truck and/or trailer dealer.The duration and mileage ZF CV Systems North America LLC and its North American coverage of this warranty cannot exceed the coverage extended subsidiaries and affiliates(ZF)warrant to the owner("Owner")that the to the first Owner_arter his or her initial designation of vocational components listed in this publication,which have been installed by an rise.Coverage under ZF's warranty requires that the application of Original Equipment Manufacturer("OEM")as original equipment will be products be properly approved pursuant to OEM and ZF,approvals. free from detects in material and workmanship.This warranty coverage begins from the original in-service date to the limits provided and runs concurrently with any warranties provided by OEMs and/or (3) What is the Cost of this Warranty?There is no charge to the Owner for any distribution agreements and/or any service contracts that cover this warranty. the components listed in this publication,if any.It the components listed in this publication are covered by an OEM warranty and/or (4) What is not Covered by this Warranty'?In addition to the items listed on service contract,then the OEM's warranty ands'or service contract "Coverage Exclusions,"this warranty does not cover normal wear and shall supersede ZF's warranty and Owner shall comply with all OEM's tear,or service items;nor does it cover a component that fails. warranty and/or service contract requirements for claims under such malfunctions or is damaged as a result of(a)improper handling. OEM's warranty and/or service contract until those agreements expire. storage,installation.adjustment,repair or modification including Once those agreements expire and provided the ZF warranty has not the use of unauthorized attachments or changes or modification in the expired under the terms stated above,the ZF warranty will be in effect vehicle's configuration,usage,or vocation from that which was until its expiration date. originally approved by SF,(b)accident,fire or other casualty,natural disaster,road debr is,negligence,misuse,abuse,or improper use Warranty coverage ends at the expiration of the applicable time period (including loading beyond the specified maximum vehicle weight or from the date of vehicle purchase by the first Owner,or,the applicable altering engine power settings to exceed the brake system capacity), mileage limitation,whichever occurs first.Duration of coverage varies or (c)improper or insufficient maintenance(including deviation from by component and vocation as detailed previously in this publication. maintenance intervals.approved lubricants,or lube levels).This Some components are warranted for parts only and the Owner warranty does not cover any component or part that is not sold by ZF. must pay any labor costs associated with the repair or replacement of the component.Other components are warranted for both parts (5) To obtain service.It the owner discovers within the applicable coverage and reasonable labor to repair or replace the subject component. period a defect in material or workmanship,the Owner must promptly Additional diagnostic time due to use of an outdated version of give notice to either ZF or the dealer from which the vehicle was TOOLBOXIM' time to purchase or install latest version of TOOLBOXTM purchased.To obtain service,the vehicle must be taken to any are the responsibility of the authorized SF distributor networks and are participating OEM dealer or ZF distributor networks'servicer.The not covered under product warranty.Components installed as dealer or ZF authorized servicer will inspect the vehicle and contact ZF replacements under this warranty are warranted only for the remainder for an evaluation of the claim.When authorized by ZF.the dealer or ZF of the original period of time or mileage under the original warranty. authorized servicer will repair or replace during the term of this warranty any defective WABCO component covered by this warranty. (2) Designation of Vocational Use Required.To obtain warranty coverage. (6) Disclaimer of Warranty and Limitation of remedies.TO THE Mr1XIMUM each Owner must notify SF through the OEM new truck and/or trailer EXTENT PERMITTED BY LAW.THE LIMITED WARRANTY SET dealer of the intended vocational use of the vehicle into which the FORTH HEREIN IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WABCO components have been incorporated prior to the vehicle in- WARRANTIES.EXPRESS OR IMPLIED,ARISING BY OPERATION OF service date,This notification may be accomplished by registering the LAW OR OTHERWISE, INCLUDING,WITHOUT LIMITATION.ANY vehicle through your OEM new truck and/or trailer dealer or with ZF IMPLIED WARRANTY'OF MERCHANTABILITY OR FITNESS FOR A directly.Failure to notify ZF of(I)the intended vocational use of the PARTICULAR PURPOSE AND/OR WARRANTY FOR HIDDEN OR vehicle or(II)a change in vocational use from that which was LATENT DEFECTS,AND IN NO EVENT WILL ZF OR ANY OF ITS originally designated,will result in the application of a one year. AFFILIATES BE LIABLE FOR DIRECT,INDIRECT, INCIDENTAL. unlimited mileage,parts only warranty(1.UnI;P)from the initial in- PROGRESSIVE,SPECIAL.OR CONSEQUENTIAL DAMAGES OF ANY service date.A second Owner and each subsequent Owner must KIND. also notify ZF as to the intended vocational use of the vehicle.This notification can be sent directly to ZF or through .gip �• 7) Legal action.Any legal action or claim arising from or related to this Warranty,in contract or otherwise,must be commenced within one year from the accrual of that cause of action,or be barred forever..Any dispute arising in connection with this agreement shall be governed by and construed according to the laws of the State of Michigan and be ,. ; brought,heard and determined exclusively in either the Circuit Court " for the County of Oakland,State of Michigan or the United States District Court for the Eastern District of Michigan.The parties stipulate that the referenced venues are convenient. (8) Remedy.The exclusive remedy under this warranty shall be the repair or replacement of the defective component at s option.ZF reserves r,= the right to require that all applicable covered components are available and/or returned to ZF for review and evaluation.THE MAXIMUM LIABILITY.IF ANY.OF ZF FOR ALL DAMAGES,INCLUDING WITHOUT LIMITATION CONTRACT DAMAGES,BREACH OF WARRANTY,NEGLIGENCE.STRICT s LIABILITY,OR OTHER TORT, IS LIMITED TO AN AMOUNT NOT TO "" EXCEED THE PURCHASE PRICE OF THE PRODUCT and where ;t^.Xt ,C indicated in the product and application warranty information above. .;, the inclusion of labor is limited to the standard repair time.THE ,° `-m PARTIES ACKNOWLEDGE AND AGREE THAT THE LIMITATION — OF DAMAGES PROVISION SET FORTH IN THIS PARAGRAPH SURVIVES BETWEEN THE ORIGINAL END USER AND ZF EVEN IF THE EXCLUSIVE REMEDY SET FORTH ABOVE IS DEEMED TO FAIL OF ITS ESSENTIAL PURPOSE ZF may change the design cr make 4 ,,., improvements to its Products without incurring any warranty obligation for previously manufactured Product. '.. „ : . (Y) Entire Agreement.This Is the entire agreement between ZF and the °"'~ Y ` Owner about warranty and no,ZF employee.or dealer is authorized to make any additional warranty on behalf of ZF unless in writing and Ile •' signed by an authorized representative of ZF. 2 • • For further product details contact your distributor or the WABCO Customer Care Center at 855-228-3203. About ZF Friedrichshafen AG ZF is a global technology company and supplies systems for passenger cars,commercial vehicles and industrial technology,enabling the next generation of mobility.ZF allows vehicles to see, think and act. In the four technology domains Vehicle Motion Control, Integrated Safety.Automated Driving, and Electric Mobility,ZF offers comprehensive solutions for established vehicle manufacturers and newly emerging transport and mobility service providers.ZF electrifies different kinds of vehicle's.With its products,the company contributes to reducing emissions and protecting the climate. ZF,which acquired WABCO Holdings Inc.on May 29,2020, now has 160.000 employees worldwide with approximately 260 locations in 41 countries. In 2019,the two then-independent companies achieved sales of€36.5 billion(ZF and$3.4 billion(WABCC). For more information,visit:www.wabco-na.com 2021 7F CV Systems North America LLC- All rights reser,ad-SP13'5/2.2021 WABCO z_.�.n . .._,._. ,,z ✓.-use - 0 �� Fire and Rescue Apparatus Ten (10) Year Structural Integrity Custom Cab Limited Warranty 1.LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the Buyer (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions, drivelines,axles,water pumps and generators;with respect to all such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable warranties,if any,made by the respective manufacturers thereof; Coverage: The Pierce Custom Cab shall be free from structural failures (b)any vehicle,chassis,or component,part,attachment or accessory damaged by caused by defects in material and workmanship misuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic environment,improper maintenance,accident,crash,or force majeure such as natural disaster,lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been repaired,altered or assembled in any way by any person or entity other than Pierce The date of the original purchase invoice(issued when the which,in the sole judgment of Pierce,adversely affects the performance,stability or Warranty Begins: product ships from the factory).P ry). purpose for which it was manufactured;or Ten(10)Years (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: 100,000 Miles bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced(a)without prior written approval of the Pierce Customer Service Department;or(b)at a facility which has not been approved by Pierce as to technical capability. Any repairs,modifications,alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty. 2.DISCLAIMERS OF WARRANTIES THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. 3.BUYER'S EXCLUSIVE REMEDY. Conditions and This warranty applies only to the cab tubular support and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: mounting structures and other structural components of the period,and such nonconformity is not due to misuse,neglect,accident or improper cab of the vehicle model,as Identified in the Pierce maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also specifications for the Fire and Rescue Apparatus. and shall make the product available for inspection by Pierce or its designated agent.At Paragraphs the request of Pierce,any allegedly defective product shall be retumed to Pierce by 2 thru 4 This warranty does not apply to damage caused by corrosion. Buyer for examination and/or repair.Buyer shall be responsible for the cost of such transportation,and for risk of loss of or damage to the product during transportation. Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) any nonconforming or defective parts.Repair or replacement shall be made only by a facility approved in advance in writing by Pierce.THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL,SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER, WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the foregoing,Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages,penalties, with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues,loss of vehicles or products or any associated normal to the particular model.Normal service means service which does not subject the equipment,cost of substitute vehicles or products,down-time,delay damages,any other product to stresses or impacts greater than normally result from careful use.If the Buyer types of economic loss,or for any claims by any third party for any such damages. discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surety Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if any) or to the warranties(if any)made by any manufacturer(other than Pierce)of any part, component,attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0012 .h� � Fire and Rescue Apparatus Ten (10) Year Pro-Rated Paint and Corrosion Cab Amite"waUas 1.LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the Buyer: (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions, drivelines,axles,water pumps and generators;with respect to all such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable Exterior surfaces of the cab painted by Pierce shall be free warranties,if any,made by the respective manufacturers thereof; from blistering,peeling,corrosion or any other adhesion (b)any vehicle,chassis,or component,part,attachment or accessory damaged by Coverage: defect caused bydefective manufacturingmethods orpaint misuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic material selection. environment,improper maintenance,accident,crash,or force majeure such as natural disaster,lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been repaired,altered or assembled in any way by any person or entity other than Pierce The date of the original purchase invoice(issued when the which,in the sole judgment of Pierce,adversely affects the performance,stability or Warranty Begins: product ships from the facto P rY) purpose for which it was manufactured;or (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Ten(10)Years during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is This limited warranty is applicable to the vehicle in the repaired or replaced(a)without prior written approval of the Pierce Customer Service following percentage costs of warranty repair,if any: Department;or(b)at a facility which has not been approved by Pierce as to technical capability. Any repairs,modifications,alterations or afternarket parts added after Topcoat Durability&Appearance:Gloss,Color Retention& manufacture without the authorization of Pierce may void this warranty. Cracking 2.DISCLAIMERS OF WARRANTIES 0-72 months 100% 73-96 months 50% THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE 97-120 months 25% WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, Integrity of Coating System:Adhesion,Blistering/Bubbling INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY 036 months 100% WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES 37-84 months 50% ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. , 85-120 months 25% 3.BUYER'S EXCLUSIVE REMEDY. Conditions and If theproduct fails to conform to the warrantyset forth in paragraph 1 duringthe warranty Exclusions: Corrosion:Dissimilar Metal and Crevice P 9 P 0-36 months 100% period,and such nonconformity is not due to misuse,neglect,accident or improper 37-48 months 50% maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also 49-72 months 25% and shall make the product available for inspection by Pierce or its designated agent.At Paragraphs the request of Pierce,any allegedly defective product shall be returned to Pierce by 73-120 months 10% 2 thru 4 Buyer for examination and/or repair.Buyer shall be responsible for the cost of such Corrosion Perforation transportation,and for risk of loss of or damage to the product during transportation. 0-120 months 100% Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) any nonconforming or defective parts.Repair or replacement shall be made only by a This limited warranty applies only to exterior paint.Paint on facility approved in advance in writing by Pierce.THIS REMEDY SHALL BE THE the vehicle's interior is warranted only under the Pierce Basic EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. One Year Limited Warranty. , 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Items not covered by this warranty include: Notwithstanding anything to the contrary herein or in any agreement between Pierce and (a)Damage from lack of maintenance and cleaning (proper Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, y cleaning and maintenance procedures are detailed in the INCIDENTAL,SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER, Pierce operation and maintenance manual). WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (b)UV paint fade. (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW (c)Any cab not manufactured by Pierce. OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the foregoing,Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages,penalties, with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues,loss of vehicles or products or any associated normal to the particular model.Normal service means service which does not subject the equipment,cost of substitute vehicles or products,down-time,delay damages,any other product to stresses or impacts greater than normally result from careful use.If the Buyer types of economic loss,or for any claims by any third party for any such damages. discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surety Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if any) II or to the warranties(if any)made by any manufacturer(other than Pierce)of any part, component,attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0055 PGetce q Fire and Rescue Apparatus 54 Months Material and Workmanship Camera System Limited Warranty 1.LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the Buyer: (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions, drivelines,axles,water pumps and generators;with respect to all such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable This limited warranty covers repairs to correct any defect warranties,if any,made by the respective manufacturers thereof; related to materials or workmanship of the Sharpvision (b)any vehicle,chassis,or component,part,attachment or accessory damaged by Coverage: camera system installed on the apparatus occuringduringthE Y PPmisuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic warranty period. environment,improper maintenance,accident,crash,or force majeure such as natural disaster,lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been repaired,altered or assembled in any way by any person or entity other than Pierce Warranty Begins: The date of delivery. which,in the sole judgment of Pierce,adversely affects the performance,stability or purpose for which it was manufactured;or (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Fifty-Four(54)months during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced(a)without prior written approval of the Pierce Customer Service Department;or(b)at a facility which has not been approved by Pierce as to technical capability. Any repairs,modifications,alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty. 2.DISCLAIMERS OF WARRANTIES THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. 3.BUYER'S EXCLUSIVE REMEDY. Conditions and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: period,and such nonconformi is not due to misuse,neglect,accident or improper This limited warranty does not apply to related wire ty harnesses,cables,and connectors,which are covered by the maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also Pierce one(1)year basic apparatus limited warranty. and shall make the product available for inspection by Pierce or its designated agent.At Paragraphs the request of Pierce,any allegedly defective product shall be returned to Pierce by 2 thru 4 Buyer for examination and/or repair.Buyer shall be responsible for the cost of such transportation,and for risk of loss of or damage to the product during transportation. Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) any nonconforming or defective parts.Repair or replacement shall be made only by a facility approved in advance in writing by Pierce.THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL,SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER, WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the foregoing,Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages,penalties, with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues,loss of vehicles or products or any associated normal to the particular model.Normal service means service which does not subject the equipment,cost of substitute vehicles or products,down-time,delay damages,any other product to stresses or impacts greater than normally result from careful use.If the Buyer types of economic loss,or for any claims by any third party for any such damages. discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surety Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if any) or to the warranties(if any)made by any manufacturer(other than Pierce)of any part, component,attachment or accessory that is incorporated into or attached to the vehicle. 1/11/2011 WA0188 43 nIM MPJFelf0l-0.1M eJiEelNNIFJPKOgel(el(elfe!(elfelMfelUpMlMINielrelNEJMlhJNVA JIMlUMNIBIMPTEelEelfelfellelfelfelNEIPJFIRIPM1'MPIWY L LI 2 NEW PRODUCT WARRANTY EAlli PARTICIPATING OEM SALES G m. . Transmission. DISTRIBUTOR SALES 2- Z LIMITED WARRANTY ON NEW ALLISON AUTOMATIC TRANSMISSIONS E M. USED IN EMERGENCY VEHICLE APPLICATIONS 2 2 G m m- G Allison Transmission will provide for repairs or replacement,at its option,during the warranty period of each new Allison transmission G Glisted below that is installed in an Emergency Vehicle in accordance with the following terms,conditions,and limitations. G G WHAT IS COVERED M" G • WARRANTY APPLIES—This warranty is for new Allison transmission models listed below installed in an Emergency Vehicle and G G G is provided to the original and any subsequent owner(s)of the vehicle during the warranty period. El ir • REPAIRS COVERED—The warranty covers repairs or replacement,at Allison Transmission's option,to correct any transmission G G malfunction resulting from defects in material or workmanship occurring during the warranty period. Needed repairs or replacements G G will be performed using the method Allison Transmission determines most appropriate under the circumstances. G• 57 TOWING—Towing is covered to the nearest Allison Transmission Distributor or authorized Dealer only when necessary to prevent G G further damage to your transmission. G C G G • PAYMENT TERMS—Warranty repairs,including parts and labor,will be covered per the schedule shown in the chart contained in G g section"APPLICABLE MODELS,WARRANTY LIMITATIONS,AND ADJUSTMENT SCHEDULE." 9 7 • OBTAINING REPAIRS—To obtain warranty repairs,take the vehicle to any Allison Transmission Distributor or authorized Dealer gi E within a reasonable amount of time and request the needed repairs. A reasonable amount of time must be allowed for the Distributor or G E Dealer to perform necessary repairs. M. M. G • TRANSMISSION REMOVAL AND REINSTALLATION—Labor costs for the removal and re-installation of the transmission, G C when necessary to make a warranty repair,are covered by this warranty. G C • WARRANTY PERIOD—The warranty period for all coverages shall begin on the date the transmission is delivered to the first retail G C purchaser,with the following exception: E C G Demonstration Service-A transmission in a new truck or bus may be demonstrated to a total of 5000 miles(8000 kilometers). G C If the vehicle is within this limit when sold to a retail purchaser,the warranty start date is the date of purchase. Normal warranty G C services are applicable to the demonstrating Dealer. Should the truck or bus be sold to a retail purchaser after these limits are 9 r reached,the warranty period will begin on the date the vehicle was first placed in demonstration service and the purchaser will be G G entitled to the remaining warranty. G C G G APPLICABLE MODELS,WARRANTY LIMITATIONS,AND ADJUSTMENT SCHEDULE G G G WARRANTY LIMITATIONS ADJUSTMENT CHARGE TO BE . G O APPLICABLE (Whichever occurs first) PAID BY THE CUSTOMER 2 C MODELS Transmission Miles G C Months Parts Labor G C Or Kilometers G C MT,MD G C 3000,3200,3500,3700 0-24 No Limit No Charge No Charge C HT with Hydraulic Controls 0-24 No Limit No Charge No Charge 2 C 2 r AT,1000 SeriesTm,2000 SeriesT'6, E 2400 SeriesTm 0-36 No Limit No Charge No Charge G G C E C HT with Electronic Controls 0-60 No Limit No Charge No Charge G ✓ HD 71 1000 EVS,2100 EVS,2200 EVS G C 2350 EVS,2500 EVS,2550 EVS, G 3000 EVS,3500 EVS,4000, 0-60 No Limit No Charge No Charge G C 4000 EVS,4500,4500 EVS,4700, M" C 4700 EVS,4800,4800 EVS ff C G C 7 EPage l of 2 I C G C 2 o N'A J ilAallalelleJiNf liololaioifgJfololiJolpoldRIMMIrJiolularrgIfe.Ifelfialfial0Ifelf0J0101ialPIME1N(rJfialfiaJfeJfiaJ0J(0JI-JIglEIelCelIMPIBlleJlelfcNJMME 1/43 PIreJfeIONIFJOIMl,eJPIEIiMeMEIFI llNBIMIEIMPIPJMININIPIfell UfeJfMMEINJfelfel JFEIMIPIONORININFMNiMMlNIMPIOJIMEJIeI;NelfelfEVATI IA 12 E WHAT IS NOT COVERED G E • DAMAGE DUE TO ACCIDENT,MISUSE,or ALTERATION—Defects and damage caused as the result of any of the following G G are not covered: G G G — Flood,collision,fire,theft,freezing,vandalism,riot,explosion,or objects striking the vehicle; G E — Misuse of the vehicle; G G — Installation into unapproved applications and installations; 3 C G — Alterations or modification of the transmission or the vehicle,and G G — Damage resulting from improper storage(refer to long-term storage procedure outlined in the applicable Allison Service Manual) G 2 — Anything other than defects in Allison Transmission material or workmanship G G NOTE: This warranty is void on transmissions used in vehicles currently or previously titled as salvaged,scrapped,junked,or totaled. G G G � G • CHASSIS,BODY,and COMPONENTS—The chassis and body company(assemblers)and other component and equipment manufacturers E G are solely responsible for warranties on the chassis,body,component(s),and equipment they provide. Any transmission repair caused by an G G alteration(s)made to the Allison transmission or the vehicle which allows the transmission to be installed or operated outside of the limits E G defined in the appropriate Allison Installation Guideline is solelythe responsibility of the entitymakingthe alterations E _C�1� Po tY ()• E • DAMAGE CAUSED by LACK of MAINTENANCE or by the USE of TRANSMISSION FLUIDS NOT RECOMMENDED in G G the OPERATOR'S MANUAL—Defects and damage caused by any of the following are not covered: G G g_ — Failure to follow the recommendations of the maintenance schedule intervals applicable to the transmission; G — Failure to use transmission fluids or maintain transmission fluid levels recommended in the Operator's Manual. G 1 • MAINTENANCE—Normal maintenance(such as replacement of filters,screens,and transmission fluid)is not covered and is the E. owner's responsibility. .50 G • REPAIRS by UNAUTHORIZED DEALERS—Defects and damage caused by a service outlet that is not an authorized Allison G C G M. Transmission Distributor or Dealer are not covered. G 73 of OTHER THAN GENUINE ALLISON TRANSMISSION PARTS—Defects and damage caused by the use of parts that are -G C • not genuine Allison Transmission parts are not covered. G c z • EXTRA EXPENSES—Economic loss and extra expenses are not covered. Examples include but are not limited to: loss of vehicle G E use;inconvenience;storage;payment for loss of time or pay;vehicle rental expense;lodging;meals;or other travel costs. 2 C • "DENIED PARTY"OWNERSHIP—Warranty repair parts and labor costs are not reimbursed to any participating or non-participating E C OEMs,dealers or distributors who perform warranty work for,or on behalf of,end users identified by the United States as being a"denied G Cparty"or who are citizens of sanctioned or embargoed countries as defined by the U.S.Department of Treasury Office of Foreign Assets Control. Furthermore,warranty reimbursements are not guaranteed if the reimbursement would be contrary to any United States export control G C laws or regulations as defined by the U.S.Department of Commerce,the U.S.Department of State,or the U.S.Department of Treasury. g ET OTHER TERMS APPLICABLE TO CONSUMERS AS DEFINED by the MAGNUSON-MOSS WARRANTY ACT G C c C This warranty gives you specific legal rights and you may also have other rights which vary from state to state. G gAllison Transmission does not authorize any person to create for it any other obligation or liability in connection with these transmissions. G G ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE APPLICABLE TO G C THESE TRANSMISSIONS IS LIMITED IN DURATION TO THE DURATION OF THIS WRITTEN WARRANTY. G G PERFORMANCE OF REPAIRS AND NEEDED ADJUSTMENTS IS THE EXCLUSIVE REMEDY UNDER THIS WRITTEN G G WARRANTY OR ANY IMPLIED WARRANTY. ALLISON TRANSMISSION SHALL NOT BE LIABLE FOR INCIDENTAL OR E CONSEQUENTIAL DAMAGES(SUCH AS,BUT NOT LIMITED TO,LOST WAGES OR VEHICLE RENTAL EXPENSES) 3 C RESULTING FROM BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.** E C **Some states do not allow limitations on how long an implied warranty will last or the exclusion or limitation of incidental or G 71 consequential damages,so the above limitations or exclusions may not apply to you. G C OTHER TERMS APPLICABLE TO OTHER END-USERS C THIS WARRANTY IS THE ONLY WARRANTY APPLICABLE TO THE ALLISON TRANSMISSION MODELS LISTED G El C ABOVE AND IS EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES,EXPRESS OR IMPLIED,INCLUDING ANY 9 • IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ALLISON G C TRANSMISSION DOES NOT AUTHORIZE ANY PERSON TO CREATE FOR IT ANY OTHER OBLIGATION OR LIABILITY G C IN CONNECTION WITH SUCH TRANSMISSIONS. ALLISON TRANSMISSION SHALL NOT BE LIABLE FOR INCIDENTAL G G OR CONSEQUENTIAL DAMAGES RESULTING FROM BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY. 5. ✓ QUESTIONS a G If you have any questions regarding this warranty or the performance of warranty obligations,you may contact any Allison Transmission G E.G Distributor or Dealer or write to: E C G 3- Allison Transmission,Inc. G' C P.O.Box 894 G C Indianapolis,IN 46206-0894 G Attention: Warranty Administration PF-9 I C ECG c 3. C Form SE0616EN(201009) G GPage 2 of 2 El G E o fe]oIdragrorgife1rCIInlfelrBraimielfelidiaigso fe igroIagingla relnrrJim retfgl(olatainamfolir immiar IMliaoloroi,roligniffllollel(m!'elleJargliel(aJnuolfg0 Fire and Rescue Apparatus Five (5) Year Material and Workmanship - Transmission Oil Cooler Three (3) Year Collateral Damage Coverage Limited Warranty 1.LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the Buyer (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions, drivelines,axles,water pumps and generators:with respect to all such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable warranties,if any,made by the respective manufacturers thereof; The transmission cooler shall be free from component or Coverage: structural failures caused by defects in material and/or (b)any vehicle,chassis,or component,part,attachment or accessory damaged by workmanship. Collateral damage up to$10,000 per misuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic occurrence is available for the first three(3)years. environment,improper maintenance,accident,crash,or force majeure such as natural disaster,lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been { repaired,altered or assembled in any way by any person or entity other than Pierce Warranty Begins: The date of delivery to the first retail purchaser, which,in the sole judgment of Pierce,adversely affects the performance,stability or purpose for which it was manufactured;or (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Five(5)Years on Oil Cooler and three(3)years on collateral during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: damage coverage bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced(a)without prior written approval of the Pierce Customer Service Department;or(b)at a facility which has not been approved by Pierce as to technical capability. Any repairs,modifications,alterations or aftermarket parts added after ( manufacture without the authorization of Pierce may void this warranty. This warranty does not cover repair due to accidents, 2.DISCLAIMERS OF WARRANTIES misuse,and excessive vibration,flying debris,storage THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE damage(freezing),negligence or modification. This warranty WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES is void if any modification or repairs are performed without ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, authorization. This also voids any future warranty. INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES This warranty does not cover cost of maintenance or repairs ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. due to lack of required maintenance services as • recommended. Performance of the required maintenance 3.BUYER'S EXCLUSIVE REMEDY. Conditions and and use of proper fluids are the responsibility of the owner. If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: period,and such nonconformity is not due to misuse,neglect,accident or improper Towing is covered to the nearest distributor or authorized maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also dealer only when necessary to prevent further damage to and shall make the product available for inspection by Pierce or its designated agent.At Paragraphs your transmission. the request of Pierce,any allegedly defective product shall be returned to Pierce by 2 thru 4 Buyer for examination and/or repair.Buyer shall be responsible for the cost of such • Labor costs for the removal and reinstallation of goods may transportation,and for risk of loss of or damage to the product during transportation. be covered when necessary to make repairs. Please contact Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) your OEM for authorization. any nonconforming or defective parts.Repair or replacement shall be made only by a facility approved in advance in writing by Pierce.THIS REMEDY SHALL BE THE Replacement of cooler during the warranty period is limited EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. • to 100%of reasonable labor costs up to a maximum of$700 • to remove,replace,or repair the oil cooler. • 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL.SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER, WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the This limited warranty shall apply only if the product is properly maintained in accordance foregoing,Pierce specifically disclaims any liability for property or personal injury with Pierce's maintenance instructions and manuals and is used in service which is damages,penalties,damages for lost profits or revenues,loss of vehicles or products or normal to the particular model.Normal service means service which does not subject the any associated equipment,cost of substitute vehicles or products,down-time,delay I product to stresses or impacts greater than normally result from careful use.If the Buyer damages,any other types of economic loss,or for any claims by any third party for any discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days such damages. after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surety Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for • OR TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if • any)or to the warranties(if any)made by any manufacturer(other than Pierce)of any • part,component,attachment or accessory that is incorporated into or attached to the vehicle. 2/22/2012 WA0216 ■ /A� :war' UNITED PLASTIC FABRICATING Limited Lifetime Warranty Effective as of January 1, 2024 1. General. United Plastic Fabricating, Inc. (the event shall Company be required to expend, in any one "Company") warrants to the owner (the "Owner") that (1) or series of expenditures, more than the purchase the products set forth on Exhibit A, attached hereto(the price of the Product to repair or replace a defective "Product") will be reasonably free from defects in Product. Amounts expended by Company shall include materials and workmanship for the service life of the all amounts paid by Company in connection the repair Product. This Limited Lifetime Warranty (the or replacement, including without limitation, amounts "Warranty")only applies to Company Products that are: paid to third-parties, material costs, incidental costs and (a) owned by a federal, state, county or local travel costs (except as provided by Section 3). government, a volunteer fire department or dedicated commercial fire service operation; (b) continuously and 3. Travel; Expenses; Product Access. Company shall actively used in emergency response and/or fire be responsible for any travel costs incurred to repair or suppression vehicles; and (c) used, stored, handled replace the Product provided that: (a) the Product is and installed in the manner recommended by located in the continental United States or Canada; and Company. (ii) the warranty claim is initiated prior to the date on which NFPA 1912 Standards (Annex D) recommends 2. Warranty Obligations. Subject to the exclusions and replacement of the Product. All other travel costs limitations set forth in this Warranty, Company will,at its incurred by Company or its agents to repair or replace option, repair or offer a one (1)time replacement of the the Product shall be the responsibility of the party Product without charge, if the Product fails or does not asserting the warranty claim. Company reserves the perform as warranted during the warranty period due to right to require, as a condition to undertaking any repair a manufacturing defect or a defect in materials. Repair or replacement: (y)pre-payment of its anticipated travel or replacement shall include reasonable labor charges costs; and (z) satisfactory arraignments concerning necessary to repair or replace the defective Product but scheduling and access to the Product. If the subject shall not include: (a)the costs associated with removal Product is located in an area of the world considered, in of the Product from the vehicle or the cost to otherwise Company's sole discretion, to be unsafe Company may provide access to the Product in the vehicle; (b)the cost refuse to process the claim or require relocation of the associated with any required upgrades the vehicle Product, at no expense to Company, to an area where (including, without limitation, upgrades required to such repairs can be performed safely by Company or strengthen the vehicle's frame); or (c) travel costs, its agents. In the event Company or Company's agents except as provided by Section 3. Company's obligation are dispatched to repair or replace a defective Product as to repair or replacement shall further be limited to and the vehicle in which the Product has been installed repair or replacement with the models of the Product is not available or the Product is not readily accessible, that are available at the time of the repair or for any reason, Company or Company's agents, as the replacement, and shall be limited to the repair or case may be, shall be immediately reimbursed for all replacement of only the specific Product that fails due expenses incurred therewith. to a manufacturing defect. In the event a Product becomes unavailable or cannot be supplied by 4. Exclusions: Products must be stored, handled, Company for any reason a substitute Product of equal installed, used and maintained in accordance with quality and functionality of the subject Product may be instructions provided by Company, and this Warranty is substituted by Company. Any repaired Product shall conditioned upon compliance with all such instructions. remain subject to this Warranty and any repair shall not This Warranty does not cover defects caused by: (a) extend the warranty period in any manner or start a new improper installation; (b) modification, alteration or warranty period. Any Product that is replaced by repair of the Product by any unauthorized third-party; Company shall be excluded from this Warranty. In no (c) misuse, including, without limitation, improper storage or handling of the Product (e.g. excessive LOSS OF REVENUES, INCONVENIENCE, LOSS exposure to UV rays); chemical abuse (e.g. harsh BUSINESS OPPORTUNITIES, OR DAMAGE TO cleansers and solvents), thermal abuse or shock (e.g. GOOD WILL OR REPUTATION, EVEN IF ADVISED excessive heat or cold); (d) damage not resulting from OF THE POSSIBILITY OF SUCH DAMAGES OR manufacturing defects that occur while the Product is SUCH DAMAGES COULD HAVE BEEN not in Company's possession (e.g. accidents); or (e) REASONABLY FORESEEN, IN CONNECTION WITH, unreasonable or unintended use of the Product. Copies ARISING OUT OF, OR AS A RESULT OF, THE SALE, of the Company's operation and maintenance DELIVERY, SERVICING, USE OR LOSS OF USE OF instructions are available on the Company's website THE PRODUCTS SOLD HEREUNDER, OR FOR ANY https://www.unitedplastic.com/upf-documents/ LIABILITY OF BUYER TO ANY THIRD PARTY WITH RESPECT THERETO. 5. Disclaimer. THE WARRANTIES SET FORTH HEREIN ARE THE ONLY WARRANTIES MADE BY 7. Reformation. If any term or provision of this Warranty COMPANY IN CONNECTION WITH THE PRODUCT. shall be held or deemed to be,or shall in fact be, invalid, COMPANY CAN NOT AND DOES NOT MAKE ANY inoperative, illegal or unenforceable as applied in any IMPLIED OR EXPRESS WARRANTIES WITH case or in any jurisdiction or jurisdictions because of the RESPECT TO THE PRODUCT,AND DISCLAIMS ALL conflicting nature of any provision with any constitution OTHER WARRANTIES, INCLUDING, BUT NOT or statute or rule of public policy or for any other reason, LIMITED TO, ANY WARRANTY OF then: (a) such circumstance shall not have the effect of MERCHANTABILITY OR FITNESS FOR A rendering the provision or provisions in question invalid, PARTICULAR PURPOSE. PRODUCTS SOLD BY inoperative, illegal or unenforceable in any other COMPANY ARE SOLD ONLY TO THE jurisdiction or in any other case or circumstance or of SPECIFICATIONS SPECIFICALLY SET FORTH BY rendering any other provision or provisions herein COMPANY IN WRITING. OTHER THAN THE LIMITED contained invalid, inoperative, illegal or unenforceable WARRANTY SET FORTH HEREIN, COMPANY to the extent that such other provisions are not MAKES NO OTHER WARRANTIES, EXPRESS OR themselves actually in conflict with such constitution, IMPLIED. COMPANY'S SOLE OBLIGATION UNDER statute or rule of public policy; and (b) any such THIS WARRANTY SHALL BE REPAIR OR invalid, inoperative, illegal or unenforceable provision REPLACEMENT OF NON-CONFORMING PRODUCT. shall be reformed and construed in any such jurisdiction BUYER ASSUMES ALL RISK WHATSOEVER AS TO or case so that such provision would be valid, operative THE RESULT OF THE USE OF THE PRODUCT and enforceable to the maximum extent permitted in PURCHASED,WHETHER USED SINGULARLY OR IN such jurisdiction or case. COMBINATION WITH ANY OTHER PRODUCTS OR SUBSTANCES. 8. Headings. The headings contained herein are for convenience and reference only, and shall be given no 6. Limitation of Liability. NO CLAIM BY OWNER OF effect in the interpretation of any term or condition of ANY KIND, INCLUDING CLAIMS FOR this Warranty. INDEMNIFICATION, SHALL BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE 9. Submitting a Warranty Claim. To request coverage PRODUCT IN RESPECT TO WHICH DAMAGES ARE under this Warranty you must submit a claim through CLAIMED. IN NO EVENT SHALL COMPANY BE Company's_website: LIABLE TO OWNER IN TORT, CONTRACT OR https://www.unitedplastic.com/contact/product-support/ OTHERWISE, FOR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL (INCLUDING, 10. Transferability. This Warranty is transferable and WITHOUT LIMITATION, ANY OBLIGATION OF entitles the transferee to coverage for the remainder of COMPANY TO REPAIR OR REPLACE ANY the original warranty period. CHASSIS, SUB-FRAMES, BODIES, VALVES, DUMPS, HOSES, PRESSURE VACUUM VENTS OR 11. Modification. This Warranty may be modified (a)as OTHER SIMILAR COMPONENTS), RELIANCE, set forth on a binding sales order for the Product or(b) STATUTORY, SPECIAL, PUNITIVE OR EXEMPLARY by a written agreement between Company and the DAMAGES, INCLUDING, BUT NOT LIMITED TO, Owner. LOST PROFITS, LOSS OF USE, LOSS OF TIME, Exhibit A Covered Product List • Poly-Tanks® • PolySide®Wetside Tanks • DefenderTM Skid Tanks • Ellip-TT" Elliptical Tanks • ARFF Tanks �Ge- e Fire and Rescue Apparatus Ten (10) Year Structural Integrity Apparatus Body Limited Warranty 1,LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the Buyer: (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions, drivelines,axles,water pumps and generators;with respect to all such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable warranties,if any,made by the respective manufacturers thereof; The apparatus body shall be free from structural failures (b)any vehicle,chassis,or component,part,attachment or accessory damaged by Coverage: caused bydefects in material and workmanship P misuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic environment,improper maintenance,accident,crash,or force majeure such as natural disaster,lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been repaired,altered or assembled in any way by any person or entity other than Pierce The date of the original purchase invoice(issued when the which,in the sole judgment of Pierce,adversely affects the performance,stability or Warranty Begins: product ships from the facto P factory). purpose for which it was manufactured;or Ten(10)Years (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: 100,000 Miles bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced(a)without prior written approval of the Pierce Customer Service Department;or(b)at a facility which has not been approved by Pierce as to technical capability. Any repairs,modifications,alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty. 2.DISCLAIMERS OF WARRANTIES THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. 3.BUYER'S EXCLUSIVE REMEDY. Conditions and This warranty applies only to the body tubular support and If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: mounting structures and other structural components of the period,and such nonconformity is not due to misuse,neglect,accident or improper body of the vehicle model,as identified in the Pierce maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also specifications for the Fire and Rescue Apparatus. and shall make the product available for inspection by Pierce or its designated agent.At Paragraphs the request of Pierce,any allegedly defective product shall be returned to Pierce by 2 thru 4 This warranty does not apply to damage caused by corrosion. Buyer for examination and/or repair.Buyer shall be responsible for the cost of such transportation,and for risk of loss of or damage to the product during transportation. Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) any nonconforming or defective parts.Repair or replacement shall be made only by a facility approved in advance in writing by Pierce.THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL,SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER, WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the foregoing,Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages,penalties, with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues,loss of vehicles or products or any associated normal to the particular model.Normal service means service which does not subject the equipment,cost of substitute vehicles or products,down-time,delay damages,any other product to stresses or impacts greater than normally result from careful use.If the Buyer types of economic loss,or for any claims by any third party for any such damages. discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surety Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if any) or to the warranties(if any)made by any manufacturer(other than Pierce)of any part, component,attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0009 Effective March 15, 2010 SPECIALTY ...._, AMP_ ROLL - U P DOORS AMDOR Inc. TERMS OF BUSINESS AND GENERAL INFORMATION Warranty: All AMDOR Inc. roll-up door products are warranted for a period of 10 years from the date of delivery (with the exception of wet paint adhesion - please see below). AMDOR Inc. liability covers the replacement or repair of any component that fails due to defects in material and / or workmanship during the coverage period. We accept no liability for claims made for damages to any part (or parts) of a vehicle and / or machine (of any type) or injury claims by a person or persons assumed or alleged to have been brought about by the use or misuse of any product supplied by AMDOR Inc. Warranty coverage does not extend to door attachments including (but not limited to) decals, emblems, stripes and adhesives. In order to initiate the claims process please contact your authorized representative of AMDOR Inc. Warranty claims must be accompanied by a written description providing full and reasonable details as to the nature of the defect. Upon receipt of your claim arrangements will be made to inspect the defective product (if necessary). Justified warranty claims will be repaired, exchanged, or credited to the customer's account at AMDOR Inc.'s discretion. All warranty claims must be approved in writing by the Customer Service Manager for AMDOR Inc. There are no exceptions to this clause. Limited warranty coverage includes the labor associated with the disassembly and assembly of products deemed to be defective by AMDOR Inc. Labor allowances are based on a set time schedule as determined by AMDOR Inc. The maximum allowable hourly labor rate is $ 50. All warranty labor claims must be approved in writing by an authorized representative of AMDOR Inc. prior to commencement of work. Allowances for removal and installation: Curtain replacement: 3/4 hour Balancer replacement: 1 hour Door ajar switch 3/4 hour Bottom Panel Assembly: 1/2 hour Slat replacement: 3/4 hour Door removal and replacement 1 1/2 hours Items authorized for return must be accompanied by a Return Goods Authorization (RGA) number. We will accept collect shipments of items deemed to be defective provided that they are returned via the most economical carrier. Should items be returned by means other than the most economical carrier the difference will be charged back to the sender. AMDOR Inc. reserves the right to reject any claim when a product has been opened, interfered with or modified. Claims may also be rejected when damage to the product (or any sub-assembly) has been brought about by accident, misuse, abuse, vandalism, incorrect installation, temperature extremes, chemical exposure or any factor other than regular operating conditions. Limited Wet Paint Match Adhesion Warranty AMDOR Inc. warrants wet paint finishes applied by AMDOR utilizing our approved factory paint specification. All wet paint match colors must be approved in writing by an authorized OEM representative. AMDOR Inc. will provide a color spray out for this purpose. The time required for shipping and consideration of initial color spray outs will be considered over and above stated lead times. Warranty coverage will extend for a period of not less than 5 years from the date of delivery as determined by AMDOR Inc.'s Packing Slip. AMDOR reserves the right to determine whether individual units will be replaced and / or repaired by an AMDOR approved vendor. An allowance will be made for labor associated with the disassembly and assembly of individual units at the prescribed hourly rate of $ 50 per hour. Compensation for labor will not exceed the maximum time allowance permitted for door removal and replacement. Written approval including specified allowance for time must be obtained from AMDOR prior to initiating work. Warranty coverage will extend to the following visible paint system defects: 1./ Loss of mechanical adhesion as evidenced by peeling, cracking or blistering which exposes the substrate material. 2./ Corrosion of the substrate due to paint system failure. 3./ Fading which results in a substantial departure from the primary AMDOR approved body color. Wet paint adhesion limited warranty coverage will be excluded when damages to the system are determined by AMDOR Inc. to be a result of the following: 1./ Damage caused through the use of attachments including (but not limited to) decals, labels, adhesives, non factory approved coatings. 2./ Loss of gloss, discoloration or damage due to improper maintenance (including but not limited to) mechanical wash systems, pressure washers, steam cleaners, non approved wash or polishing agents. 3./ Abuse, acts of nature, excessive heat / cold, chemical exposure, vandalism and / or accidents. 4./ Scratches, chips, abrasions, or dents from any source. This document supercedes all previous written and / or verbal warranties provided by AMDOR Inc. and / or it's affiliates. m 0 m G J N o >, U v > W m > ( Ln 7 c E c a C YTs CZ o o a J v_, La)a s L v a) g LL C c) CO0 v - W > v o c v T� J 0 m > a) v o v -> _o >, :_. N J2N O a d) w Q co v O an cc ca 7- a v a 3 ZWZw C C N co v C O U c w � � a CC W C9 3 v LL Ems ` vi a0 c coo c G [ HQ >, •NCC Y 3 y o ° O 0 LL Q L o • J LLI ° o � O a o c _0w C. UO � Q o 8 a• L OL w cc6 C v �Q ? J J } COci (13 co a)al a-0 N � aa)) in co O -0 } I �p > •- � N ai - WNW u) •o c\ &) _c CD 7 - o,�Co 0 ac-i IX CL :� m 0 7 o) co o v v 0 c 0 L w < O � CO o 0 IICE C U a 7 y>i1 E �r.) � n. a 0c •7 a0 ° 2NHa a3 U) H T C 4- v •C L — CO- m CO cn Y • ~ Q V re -c = LU cco m a 3 v m >, a co L ° OCOQp o 0 J Ili a.) v v •� ° ° a s � � d = w >' c w Q c -c -O _c a) in cLi o ▪ m O � O � 0 I J La ° aai ° v c a c ui W W ' o Q Q (13 E a o CT Y L L co C c 3 <n Co co Q = Z it O fD E O (o Q D U C o L U J Q O Q w c .E L L � N C � � N � F- UJ W a) > :C ac) ° 0 D v c •c a) c a U p Z Q > N v3cca' O °) ° o 'c ZWWZ c 5, v `n S � oQ � � " .- L 3 a 2 OW = N v 0 0 - • � �H cy `m N m QOOW 3 a ' _ •}+ 3 Q) = cco C c < c c c co 0 o E 0C Z } a - F- �_ 0 cn 5 c"`o o o o aci v cri d Z Z Ct m 0 a O • O cQ � co •N .Z-.cn c c .c 0 Q ) 2 O} NnO o s o W J d o Q o o N f N m p - 0 U U a 2 LLIL aai ca .0 f6 0M D >, c v p0L >0 0 o ce m ' 'Ws .2 Lo _cQ L cE O >, . v w � Hu) -° a 1 V o co U �' C L co J D J W a) i U ix �° `6 `� y Qfl w _c o) •c aamQ CO CO > W L ` coV/ yJ ° U Q -p L c y 2 Ce Q .0 L U H L v 1 7 N �Yc2 �'o o 2 o omi- o .0 0 0 a 0 a m 3 ' _0(1) o f .0 .0 a E c V U_ J m W Z CD cv v o�Qn c >, c L co N s o Y Q a 2 c L o C O N N H < 3 0 7 p c ,- -C N •F3 CM W Cr a c 0 0 >, L C) E aa) c '- /0 � cca co v .E L 2 aaWw 0 o_ `W` Cr) E a)E. > C 0 c 45 L o X Q D O Ce 4- O L / v♦ Q 0 2 0 � a � L. c = a c2 cereU W >'a a N Z w N a � oQ co c E ..2 0 v CD c - W O W N Q a`) `n o f o .Sc � a� io cn L y OZ > > m a .a v m aXi co L `m ` o m N J O c cn X 0 a x _0 0 a T c ° L 0 a) N W w Q U o a v W L. 2 E °) U) U c co 8 o c ci = Z Z IX y •• O N CD W O > ° ND a' � c c c , Lv � 00 L ° c 3 Lo y < co U c LL J _ Q 'c 0 L w � W - c co cts a v 0 c a m W /,/ Z_ Q = D Q� L o Z L ai 0 1- 1- a c°i .c ° ° E > in � LOLDZ v �0/ a •_ a a� W/ 7, yam-+ w Q v •�Q co V a L o J } J W N LL E) — O c la. ~ L = vvQ> `n o E ,cow >, a E c V � V ❑ da> op W - C � � C 0 a) aL) c s = a`vi E ' X J Z V Y Q cp C 0 = co v >, o cc = a 0 u) m Y 0) Ws Wm �'Z -0 a) a c, w .c > c -a TO v a 2 E o � (0 c a WQH C a y E ° •c z cn a 0 c a ,. o w a 0 m o -C U E � a aa) co 0 Q Z O Q Lv 0 � ° 73 Q r co v ° ° O > N w L 0 v a Eci) Q H >,.. C CO L H o a U a o C -° 0 0 5 j O N '• W- C) } W m y v OU N L O 0 K' �;o 0 > � LcLo OC .� °- �a) 7 o ..„ zWzv�i o � � ° ° °c y � � E C al va0 " = 0)° cn >- O in 3 W � Ce W 73� CV CO w W cC In 0 z 6 L 0 aL 0 0 Ill .2 a ccoo a, a 0 0 CL w Ce > pa) a 2a 2 E 0 el) 0 a) 3 -a a'§ v co a a) CO ryry 0,, c c O N Z v 0 a) C 2 E Q y .° X a a W Y C W v .= v- - Y W 0 C '' V) U) u) E Uj co CC - i- a .> E CC U a 0 o _ Ocn0@a0 = ZQ } O >, N � -E . a) wcw -acw 0 ca T -o m pLij 0Z1- Q x al ca .n W o cvL Q co 0 ~Q> ° � Q ° � ao � CX R '= ' 3 C > a8 _0 QsU � I- a) 03 TN ,' -_ iretice Fire and Rescue Apparatus Ten (10) Year Material and Workmanship Stainless Steel Piping Limited Warranty 1.LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the Buyer (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions. drivelines,axles,water pumps and generators;with respect to all such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable Stainless steel i m shall be free from structural failures warranties,if any,made by the respective manufacturers thereof; Pp 9 Coverage: caused by defects in material and workmanship,or (b)any vehicle,chassis,or component,part,attachment or accessory damaged by perforation caused by corrosion. misuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic environment,improper maintenance,accident,crash,or force majeure such as natural disaster,lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been repaired,altered or assembled in any way by any person or entity other than Pierce Warranty Begins: The date of the original purchase invoice(issued when the which,in the sole judgment of Pierce,adversely affects the performance,stability or product ships from the factory). purpose for which it was manufactured;or Ten(10)Years (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: 100,000 Miles bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced(a)without prior written approval of the Pierce Customer Service Department;or(b)at a facility which has not been approved by Pierce as to technical capability. Any repairs,modifications,alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty. 2.DISCLAIMERS OF WARRANTIES THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. Pierce's obligation under this warranty is limited to repairing or replacing without charge,as Pierce may elect,the 3.BUYER'S EXCLUSIVE REMEDY. Conditions and stainless steel piping or components which Pierce If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: determines to have failed due to defective material and period,and such nonconformity is not due to misuse,neglect,accident or improper workmanship,or perforation caused by corrosion. maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also and shall make the product available for inspection by Pierce or its designated agent.At Paragraphs This warranty does not cover the use of fluoroprotein(FP) the request of Pierce,any allegedly defective product shall be returned to Pierce by 2 thru 4 type foam. The sodium chloride within FP foam can cause Buyer for examination and/or repair.Buyer shall be responsible for the cost of such long-term damage to system components if not thoroughly transportation,and for risk of loss of or damage to the product during transportation. flushed immediately after use. Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) any nonconforming or defective parts.Repair or replacement shall be made only by a facility approved in advance in writing by Pierce.THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL,SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER. WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the This limited warranty shall apply only if the product is properly maintained in accordance foregoing,Pierce specifically disclaims any liability for property or personal injury with Pierce's maintenance instructions and manuals and is used in service which is damages,penalties,damages for lost profits or revenues,loss of vehicles or products or normal to the particular model.Normal service means service which does not subject the any associated equipment,cost of substitute vehicles or products,down-time,delay product to stresses or impacts greater than normally result from careful use.If the Buyer damages,any other types of economic loss,or for any claims by any third party for any discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days such damages. after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surety Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if any)or to the warranties(if any)made by any manufacturer(other than Pierce)of any part,component,attachment or accessory that is incorporated into or attached to the vehicle. 3/22/2012 WA0035 • • totce Fire and Rescue Apparatus Ten (10) Year Pro-Rated Paint and Corrosion Custom Body Limited Warranty 1.LIMITED WARRANTY Notwithstanding anything to the contrary herein,Pierce makes no warranty whatsoever as to: Subject to the limitations and exclusions set forth below,Pierce Manufacturing provides the following warranty to the Buyer (a)any integral parts,components,attachments or trade accessories of or to the product that are not manufactured by Pierce,including but not limited to engines,transmissions, drivelines,axles,water pumps and generators;with respect to all such parts, components,attachments and accessories,Pierce shall assign to Buyer the applicable warranties,if any,made by the respective manufacturers thereof; Exterior surfaces of the body shall be free from blistering, Coverage: peeling,corrosion or any other adhesion defect caused by (b)any vehicle,chassis,or component,part,attachment or accessory damaged by defective manufacturing methods or paint material selection. misuse,neglect,fire,exposure to severe environmental or chemical conditions,acidic environment,improper maintenance,accident,crash,or force majeure such as natural disaster.lightning,earthquake,windstorm,hail,flood,war or riot; (c)any vehicle,chassis or component,part,attachment or accessory that has been repaired,altered or assembled in any way by any person or entity other than Pierce Warranty Begins: The date of the original purchase invoice(issued when the which,in the sole judgment of Pierce.adversely affects the performance,stability or product ships from the factory). purpose for which it was manufactured;or (d)products or parts which may in the ordinary course wear out and have to be replaced Warranty Period Ten(10)Years during the warranty period,including,but not limited to,tires,fluids,gaskets and light Ends After: bulbs.Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. The original purchaser may void this warranty in part or in its entirety if the product is This limited warranty is applicable to the vehicle in the repaired or replaced(a)without prior written approval of the Pierce Customer Service following percentage costs of warranty repair,if any: Department;or(b)at a facility which has not been approved by Pierce as to technical capability. Any repairs,modifications,alterations or aftermarket parts added after Topcoat Durability&Appearance:Gloss,Color Retention& manufacture without the authorization of Pierce may void this warranty. Cracking 2.DISCLAIMERS OF WARRANTIES 0-72 months 100% 73-96 months 50% THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE 97-120 months 25% WARRANTY GIVEN BY PIERCE.PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES,WHETHER EXPRESS,IMPLIED OR STATUTORY, Integrity of Coating System:Adhesion,Blistering/Bubbling INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY,ANY 0-36 months 100% WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE,AND ANY WARRANTIES 37-84 months 50% ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. 85-120 months 25% 3.BUYER'S EXCLUSIVE REMEDY. Conditions and Corrosion:Dissimilar Metal and Crevice If the product fails to conform to the warranty set forth in paragraph 1 during the warranty Exclusions: 0-36 months 100% period,and such nonconformity is not due to misuse,neglect,accident or improper 37-48 months 50% maintenance,Buyer must notify Pierce within the time period specified in paragraph 1, See Also 49-72 months 25% and shall make the product available for inspection by Pierce or its designated agent.At Paragraphs the request of Pierce,any allegedly defective product shall be retumed to Pierce by 2 thru 4 73-120 months 10% Buyer for examination and/or repair.Buyer shall be responsible for the cost of such Corrosion Perforation transportation,and for risk of loss of or damage to the product during transportation. 0-120 months 100% Within a reasonable time,Pierce shall repair or replace(at Pierce's option and expense) any nonconforming or defective parts.Repair or replacement shall be made only by a This limited warranty applies only to exterior paint.Paint on facility approved in advance in writing by Pierce.THIS REMEDY SHALL BE THE the vehicle's interior is warranted only under the Pierce Basic EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY. One Year Limited Warranty. 4.EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES. Items not covered by this warranty include: Notwithstanding anything to the contrary herein or in any agreement between Pierce and (a)Damage from lack of maintenance and cleaning (proper Buyer,IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL, cleaning and maintenance procedures are detailed in the INCIDENTAL,SPECIAL,INDIRECT,OR PUNITIVE DAMAGES WHATSOEVER, Pierce operation and maintenance manual). WHETHER ARISING OUT OF BREACH OF CONTRACT,WARRANTY,TORT (b)UV paint fade. (INCLUDING NEGLIGENCE AND STRICT LIABILITY)OR OTHER THEORY OF LAW (c)Any cab not manufactured by Pierce. OR EQUITY,WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,OR THEIR OPERATION OR FAILURE TO OPERATE,OR ANY DEFECTS THEREIN,OR ANY UNDERTAKINGS,ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES.Without limiting the generality of the foregoing,Pierce This limited warranty shall apply only if the product is properly maintained in accordance specifically disclaims any liability for property or personal injury damages,penalties, with Pierce's maintenance instructions and manuals and is used in service which is damages for lost profits or revenues,loss of vehicles or products or any associated normal to the particular model.Normal service means service which does not subject the equipment,cost of substitute vehicles or products,down-time,delay damages,any other product to stresses or impacts greater than normally result from careful use.If the Buyer types of economic loss,or for any claims by any third party for any such damages. discovers a defect or nonconformity,it must notify Pierce in writing within thirty(30)days after the date of discovery,but in any event prior to the expiration of the warranty period. THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE Note:Any Surety Bond,if a part of the sale of the vehicle as to which this limited TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER warranty is provided,applies only to this Pierce Basic One Year Limited Warranty for OR TO ANY OTHER PERSON OR ENTITY. such vehicle,and not to other warranties made by Pierce in a separate document(if any) or to the warranties(if any)made by any manufacturer(other than Pierce)of any part, component,attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0057 Proposal for PORT ARTHUR FIRE DEPARTMENT Prepared by Cory Frankum Siddons-Martin Emergency Group 11/09/2026 pp 4( Pettee . t PERFORM. LIKE NO OTHER.. CONTENTS SINGLE SOURCE MANUFACTURER 13 COMPARISON REPORT 13 NFPA 2024 STANDARDS 13 NFPA COMPLIANCY 13 PUMP TEST 13 GENERATOR TEST 13 PRODUCT CHANGES AND IMPROVEMENTS 13 BID BOND 14 PERFORMANCE BOND 14 APPROVAL DRAWING 14 ELECTRICAL WIRING DIAGRAMS 15 SABER FR CHASSIS 15 WHEELBASE 15 GVW RATING 15 FRAME 15 FRONT AXLE 15 FRONT SUSPENSION 15 SHOCK ABSORBERS 15 FRONT OIL SEALS 15 FRONT TIRES 15 REAR AXLE 16 TOP SPEED OF VEHICLE 16 REAR SUSPENSION 16 REAR OIL SEALS 16 REAR TIRES 16 TIRE BALANCE 16 TIRE PRESSURE MANAGEMENT 16 FRONT HUB COVERS 16 MUD FLAPS 17 WHEEL CHOCKS 17 Wheel Chock Brackets 17 ELECTRONIC STABILITY CONTROL 17 Port Arthur Stock Saber Pumper ANTI-LOCK BRAKE SYSTEM 17 AUTOMATIC TRACTION CONTROL 17 BRAKES 18 BRAKE SYSTEM AIR COMPRESSOR 18 BRAKE SYSTEM 18 BRAKE SYSTEM AIR DRYER 18 BRAKE LINES 18 AIR INLET 18 ENGINE 19 HIGH IDLE 19 ENGINE BRAKE 19 CLUTCH FAN 20 ENGINE AIR INTAKE 20 EXHAUST SYSTEM 20 RADIATOR 20 COOLANT LINES 21 FUEL TANK 21 DIESEL EXHAUST FLUID TANK 21 FUEL PRIMING PUMP 22 TRANSMISSION 22 TRANSMISSION SHIFTER 22 TRANSMISSION COOLER 22 DRIVELINE 22 STEERING 22 STEERING WHEEL 23 BUMPER 23 Gravel Pan 23 CENTER HOSE TRAY 23 Center Hose Tray Restraint 23 TOW HOOKS 23 FRONT BUMPER NOTCH 23 CAB 23 CAB ROOF DRIP RAIL 25 Port Arthur Stock Saber Pumper FENDER LINERS 25 PANORAMIC WINDSHIELD 25 WINDSHIELD WIPERS 25 ENGINE TUNNEL 26 CAB INSULATION 26 INTERIOR CREW CAB REAR WALL ADJUSTABLE SEATING (PATENT PENDING) 27 CAB REAR WALL EXTERIOR COVERING 27 CAB LIFT 27 Cab Lift Interlock 28 GRILLE 28 SIDE OF CAB MOLDING 28 MIRRORS 28 FRONT CROSS VIEW MIRROR 28 DOORS 28 Door Panels 29 ELECTRIC OPERATED CAB DOOR WINDOWS 29 CAB STEPS 29 CAB EXTERIOR HANDRAILS 30 STEP LIGHTS 30 FENDER CROWNS 30 ADDITIONAL HANDRAIL 30 CREW CAB WINDOWS 30 CAB DASH 31 MOUNTING PLATE ON ENGINE TUNNEL 31 CAB INTERIOR 31 CAB INTERIOR UPHOLSTERY 31 CAB INTERIOR PAINT 31 CAB FLOOR 31 DEFROST/AIR CONDITIONING SYSTEM 32 Cab Defroster 32 Cab/Crew Auxiliary Heater 32 Air Conditioning 32 Climate Control 33 Port Arthur Stock Saber Pumper Gravity Drain Tubes 33 SUN VISORS 33 GRAB HANDLES 34 ENGINE COMPARTMENT LIGHTS 34 ACCESS TO ENGINE DIPSTICKS 34 CAB SAFETY SYSTEM 34 Frontal Impact Protection 35 Side Roll Protection 35 SEATING CAPACITY 36 DRIVER SEAT 36 OFFICER SEAT 36 RADIO COMPARTMENT 36 REAR FACING DRIVER SIDE OUTBOARD SEAT 37 REAR FACING PASSENGER SIDE OUTBOARD SEAT 37 FORWARD FACING DRIVER SIDE OUTBOARD SEAT 37 FORWARD FACING CENTER CABINET 38 Cabinet Light 38 FORWARD FACING PASSENGER SIDE OUTBOARD SEAT 38 SEAT UPHOLSTERY 39 AIR BOTTLE HOLDERS 39 SEAT BELTS 39 HELMET STORAGE PROVIDED BY FIRE DEPARTMENT 39 CAB DOME LIGHTS 39 PORTABLE HAND LIGHTS PROVIDED BY FIRE DEPARTMENT 40 CAB INSTRUMENTATION 40 Gauges 40 Indicator Lamps 41 Alarms 41 Indicator Lamp and Alarm Prove-Out 42 Control Switches 42 Custom Switch Panels 43 Diagnostic Panel 43 AIR RESTRICTION INDICATOR 44 Port Arthur Stock Saber Pumper "DO NOT MOVE APPARATUS" INDICATOR 44 SWITCH PANELS 44 WIPER CONTROL 44 CAB USB 44 SPARE CIRCUIT 44 INFORMATION CENTER 45 COLLISION MITIGATION 45 VEHICLE DATA RECORDER 45 Seat Belt Monitoring System 46 VEHICLE CAMERA SYSTEM 46 Camera Switcher 46 ELECTRICAL POWER CONTROL SYSTEM 47 Voltage Monitor System 47 Power and Ground Studs 47 EMI/RFI Protection 47 ELECTRICAL 48 BATTERY SYSTEM 48 BATTERY SYSTEM 49 MASTER BATTERY SWITCH 49 BATTERY COMPARTMENTS 49 JUMPER STUDS 49 BATTERY CHARGER 49 REMOTE CONTROL PANEL - BATTERY CHARGER 50 AUTO EJECT FOR SHORELINE 50 ALTERNATOR 50 ELECTRONIC LOAD MANAGEMENT 50 HEADLIGHTS 51 FRONT DIRECTIONALS 51 INTERMEDIATE LIGHT 51 CAB CLEARANCE/MARKER/ID LIGHTS 51 FRONT CAB SIDE DIRECTIONAL/MARKER LIGHTS 51 REAR CLEARANCE/MARKER/ID LIGHTING 51 REAR FMVSS LIGHTING 52 Port Arthur Stock Saber Pumper LICENSE PLATE BRACKET 52 LIGHTING BEZEL 53 BACK-UP ALARM 53 CAB PERIMETER SCENE LIGHTS 53 PUMP HOUSE PERIMETER LIGHTS 53 BODY PERIMETER SCENE LIGHTS 53 STEP LIGHTS 53 12 VOLT LIGHTING 53 12 VOLT DC SCENE LIGHTS 54 12 VOLT DC SCENE LIGHTS 54 12 VOLT LIGHTING 54 12 VOLT LIGHTING 54 HOSE BED LIGHTS 55 REAR SCENE LIGHTS 55 WALKING SURFACE LIGHT 55 WATER TANK 55 SLEEVE PLUMBING THROUGH TANK 56 i WATER TANK RESTRAINT 56 HOSE BED 56 HOSE BED DIVIDER 57 HOSE BED DEFLECTOR 57 RUNNING BOARDS 57 TAILBOARD 58 REAR WALL, SMOOTH ALUMINUM/BODY MATERIAL 58 REAR TOW EYES 58 REAR TOW BAR 58 RUNNING BOARD HOSE RESTRAINT 58 HOSE TRAY 58 COMPARTMENTATION 59 UNDERBODY SUPPORT SYSTEM 59 AGGRESSIVE WALKING SURFACE 60 LOUVERS 60 TESTING OF BODY DESIGN 60 Port Arthur Stock Saber Pumper LEFT SIDE COMPARTMENTATION 60 RIGHT SIDE COMPARTMENTATION 61 SIDE COMPARTMENT ROLLUP DOOR(S) 62 REAR COMPARTMENTATION 63 ROLLUP REAR COMPARTMENT DOOR 63 COMPARTMENT LIGHTING 64 MOUNTING TRACKS 64 ADJUSTABLE SHELVES 64 SLIDE-OUT FLOOR MOUNTED TRAY 65 RUB RAIL 65 BODY FENDER CROWNS 65 BODY FENDER LINER 65 HARD SUCTION HOSE 66 HANDRAILS 66 HANDRAILS 66 HANDRAIL 66 AIR BOTTLE STORAGE (Double) 66 EXTENSION LADDER 66 ROOF LADDER 66 LADDER BRACKETS 66 FOLDING LADDER 66 PIKE POLE PROVIDED BY FIRE DEPARTMENT 67 PIKE POLE STORAGE 67 6' PIKE POLE PROVIDED BY FIRE DEPARTMENT 67 PIKE POLE STORAGE 67 FOLDING STEPS FRONT OF BODY 67 REAR FOLDING STEPS 67 PUMP COMPARTMENT 67 PUMP MOUNTING 68 LEFT SIDE PUMP CONTROL PANEL 68 IDENTIFICATION TAGS 68 PUMP 69 PUMP TRANSMISSION 70 Port Arthur Stock Saber Pumper PUMPING MODE 70 AIR PUMP SHIFT 70 TRANSMISSION LOCK-UP 70 AUXILIARY COOLING SYSTEM 70 INTAKE RELIEF VALVE - PUMP 70 PRESSURE CONTROLLER 71 PRIMING PUMP 72 PUMP MANUALS 72 STAINLESS STEEL AND HOSE PLUMBING 72 FOAM SYSTEM PLUMBING 73 MAIN PUMP INLETS 73 SHORT SUCTION TUBE(S) 73 MAIN PUMP INLET CAP 73 VALVES 73 INLET CONTROL 73 LEFT SIDE INLET 73 FRONT INLET 74 FRONT INLET CONTROL 74 FRONT INLET INTAKE RELIEF VALVE 74 FRONT INLET ELBOW 74 FRONT INLET CAP 74 INLET BLEEDER VALVE 74 TANK TO PUMP 75 TANK REFILL 75 DISCHARGE OUTLET CONTROLS 75 LEFT SIDE DISCHARGE OUTLETS 75 LEFT SIDE OUTLET ELBOWS 75 RIGHT SIDE DISCHARGE OUTLET 75 RIGHT SIDE OUTLET ELBOWS 76 LARGE DIAMETER DISCHARGE OUTLET 76 LARGE DIAMETER OUTLET ELBOWS 76 FRONT DISCHARGE OUTLET 76 REAR DISCHARGE OUTLET 76 Port Arthur Stock Saber Pumper REAR OUTLET ELBOWS 76 DISCHARGE CAPS/ INLET PLUGS 76 OUTLET BLEEDER VALVE 77 DELUGE RISER 77 MONITOR 77 CROSSLAY HOSE BEDS 77 2.50" CROSSLAY HOSE BED 78 CROSSLAY HOSE RESTRAINT 78 CROSSLAY/DEADLAY HOSE RESTRAINT 78 CROSSLAY 8.00" LOWER THAN STANDARD 78 HUSKY 3/12 FOAM SYSTEM PLUMBING (FUTURE INSTALLATION) 78 FOAM TANK 79 FOAM TANK DRAIN 79 PUMP PANEL CONFIGURATION 79 PUMP AND GAUGE PANEL 79 PUMP ACCESS 79 Right Side Panel 79 Panel Fastener 79 PUMP COMPARTMENT LIGHT 79 THROTTLE READY GREEN INDICATOR LIGHT 79 OK TO PUMP INDICATOR LIGHT 80 AIR HORN SWITCH 80 VACUUM AND PRESSURE GAUGES 80 PRESSURE GAUGES 80 WATER LEVEL GAUGE 80 WATER LEVEL GAUGE 81 FUTURE FOAM LEVEL GAUGE 81 LIGHT SHIELD 81 AIR HORN SYSTEM 82 Air Horn Location 82 Air Horn Control 82 ELECTRONIC SIREN 82 SPEAKER 82 Port Arthur Stock Saber Pumper AUXILIARY MECHANICAL SIREN 82 MECHANICAL SIREN CONTROL 83 EMERGENCY WARNING SYSTEM CONTROL 83 FRONT ZONE UPPER WARNING LIGHTS 83 LIGHTS, FRONT ZONE LOWER 84 HEADLIGHT FLASHER 84 SIDE ZONE LOWER LIGHTING 84 SIDE WARNING LIGHTS 84 REAR ZONE LOWER LIGHTING 85 REAR/SIDE ZONE UPPER WARNING LIGHTS 85 TRAFFIC DIRECTING LIGHT 85 120 VOLT RECEPTACLE 86 POWER OUTLET STRIP 86 LOOSE EQUIPMENT 86 NFPA LOOSE EQUIPMENT 86 NFPA Required Loose Equipment Provided by Fire Department 86 NFPA Loose Equipment That Should be Considered 87 SOFT SUCTION HOSE 87 DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT 87 WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT 87 FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT 87 PICKHEAD AXE PROVIDED BY FIRE DEPARTMENT 87 PAINT PROCESS 88 Environmental Impact 89 CAB PAINT 89 BODY PAINT 89 PAINT CHASSIS FRAME ASSEMBLY 89 AXLE HUB PAINT 90 COMPARTMENT INTERIOR PAINT 90 REFLECTIVE STRIPES 90 REAR CHEVRON STRIPING 90 CAB DOOR REFLECTIVE STRIPE 90 FIRE APPARATUS PARTS MANUAL 91 Port Arthur Stock Saber Pumper Service Parts Internet Site 91 CHASSIS SERVICE MANUALS 91 CHASSIS OPERATION MANUAL 92 ONE (1)YEAR MATERIAL AND WORKMANSHIP 92 ENGINE WARRANTY 92 STEERING GEAR WARRANTY 92 FIFTY (50) YEAR STRUCTURAL INTEGRITY 92 FRONT AXLE WARRANTY 92 REAR AXLE WARRANTY 92 ABS BRAKE SYSTEM THREE (3) YEAR MATERIAL AND WORKMANSHIP WARRANTY 92 TEN (10) YEAR STRUCTURAL INTEGRITY 92 TEN (10)YEAR PRO-RATED PAINT AND CORROSION 92 CAMERA SYSTEM WARRANTY 92 COMPARTMENT LIGHT WARRANTY 92 TRANSMISSION WARRANTY 92 TRANSMISSION COOLER WARRANTY 93 WATER TANK WARRANTY 93 TEN (10)YEAR STRUCTURAL INTEGRITY 93 ROLL UP DOOR MATERIAL AND WORKMANSHIP WARRANTY 93 PUMP WARRANTY 93 TEN (10) YEAR PUMP PLUMBING WARRANTY 93 TEN (10)YEAR PRO-RATED PAINT AND CORROSION 93 VEHICLE STABILITY CERTIFICATION 93 ENGINE INSTALLATION CERTIFICATION 93 POWER STEERING CERTIFICATION 93 CAB INTEGRITY CERTIFICATION 93 Side Impact 94 Frontal Impact 94 Additional Frontal Impact 94 Roof Crush 94 Additional Roof Crush 94 CAB DOOR DURABILITY CERTIFICATION 94 WINDSHIELD WIPER DURABILITY CERTIFICATION 94 Port Arthur Stock Saber Pumper ELECTRIC WINDOW DURABILITY CERTIFICATION 95 SEAT BELT ANCHOR STRENGTH 95 SEAT MOUNTING STRENGTH 95 STEPPING, STANDING &WALKING AREAS, SLIP RESISTANCE CERTIFICATION 95 PERFORMANCE CERTIFICATIONS 95 Cab Air Conditioning 95 Cab Defroster 95 Cab Auxiliary Heater 95 AMP DRAW REPORT 96 Port Arthur Stock Saber Pumper SINGLE SOURCE MANUFACTURER COMPARISON REPORT A report will be provided to allow the Sales Representative to compare the options to a previous job. The report will be provided for job 45234 NO TAK-4. NFPA 2024 STANDARDS This unit will comply with the NFPA standards effective January 1, 2024, except for fire department directed exceptions. These exceptions will be set forth in the Statement of Exceptions. Certification of slip resistance of all stepping, standing and walking surfaces will be supplied with delivery of the apparatus. All horizontal surfaces designated as a standing or walking surface that are greater than 48.00" above the ground must be defined by a 1.00" wide line along its outside perimeter. Perimeter markings and designated access paths to destination points will be identified on the customer approval print and are shown as approximate. Actual location(s)will be determined based on materials used and actual conditions at final build. Access paths may pass through hose storage areas and opening or removal of covers or restraints may be required. Access paths may require the operation of devices and equipment such as the aerial device or ladder rack. A plate that is highly visible to the driver while seated will be provided. This plate will show the overall height, length, and gross vehicle weight rating. The manufacturer will have programs in place for training, proficiency testing and performance for any staff involved with certifications. An official of the company will designate, in writing, who is qualified to witness and certify test results. NFPA COMPLIANCY Apparatus proposed by the bidder will meet the applicable requirements of the National Fire Protection Association (NFPA) as stated in the current edition at time of contract execution. Fire Department's specifications that differ from NFPA specifications will be indicated in the proposal as "non-NFPA." PUMP TEST The rated water pump will be tested, approved, and certified by an ISO certified independent third party testing agency at the manufacturer's expense. The test results, along with the pump manufacturer's certification of hydrostatic test, the engine manufacturer's certified brake horsepower curve, and the manufacturer's record of pump construction details will be forwarded to the Fire Department. GENERATOR TEST If the unit has a generator, the generator will be tested, approved, and certified by an ISO certified independent third party testing agency at the manufacturer's expense. The test results will be provided to the Fire Department at the time of delivery. PRODUCT CHANGES AND IMPROVEMENTS Our components and processes, as described in this proposal document, are as accurate as known at the time of bid submission, but are subject to change for the purpose of product or process Port Arthur Stock Saber Pumper improvements, or changes in industry standards providing the change does not affect the meaning or definition of the bid specifications. BID BOND A bid bond as security for the bid in the form of a 10 percent bid bond will be provided with the proposal. This bid bond will be issued by a Surety Company who is listed on the U.S. Treasury Departments list of acceptable sureties as published in Department Circular 570. The bid bond will be issued by an authorized representative of the Surety Company and will be accompanied by a certified power of attorney dated on or before the date of bid. The bid bond will include language which assures that the bidder/principal will give a bond or bonds, as may be specified in the bidding or contract documents, with good and sufficient surety for the faithful performance of the contract, including the Basic One (1) Year Limited Warranty, and for the prompt payment of labor and material furnished in the prosecution of the contract. Notwithstanding any document or assertion to the contrary, any surety bond related to the sale of a vehicle will apply only to the Basic One (1)Year Limited Warranty for such vehicle. Any surety bond related to the sale of a vehicle will not apply to any other warranties that are included within this bid (OEM or otherwise) or to the warranties (if any) of any third party of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. In the event of any contradiction or inconsistency between this provision and any other document or assertion, this provision will prevail. PERFORMANCE BOND Notwithstanding any document or assertion to the contrary, any surety bond related to the sale of a vehicle will apply only to the Basic One (1)Year Limited Warranty for such vehicle. Any surety bond related to the sale of a vehicle will not apply to any other warranties that are included within this bid (OEM or otherwise) or to the warranties (if any) of any third party of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. In the event of any contradiction or inconsistency between this provision and any other document or assertion, this provision will prevail. Due to global supply chain constraints, any delivery date contained herein is a good faith estimate as of the date of this order/contract, and merely an approximation based on current information. Delivery updates will be made available, and a final firm delivery date will be provided as soon as possible. If the Producer Price Index of Components for Manufacturing [www.bls.gov Series ID: WPUID6112] ("PPI") has increased at a compounded annual growth rate of 5.0 percent or more between the month Pierce accepts the order ("Order Month") and a month 14 months prior to the then predicted Ready For Pickup date ("Evaluation Month"), then pricing may be updated in an amount equal to the increase in PPI over 5.0 percent for each year or fractional year between the Order Month and the Evaluation Month. The seller will document any such updated price for the customer's approval before proceeding and provide an option to cancel the order. APPROVAL DRAWING A drawing of the proposed apparatus will be prepared and provided to the purchaser for approval before construction begins. The Pierce sales representative will also be provided with a copy of the Port Arthur Stock Saber Pumper same drawing. The finalized and approved drawing will become part of the contract documents. This drawing will indicate the chassis make and model, location of the lights, siren, horns, compartments, major components, etc. A"revised" approval drawing of the apparatus will be prepared and submitted by Pierce to the purchaser showing any changes made to the approval drawing. ELECTRICAL WIRING DIAGRAMS Two (2) electrical wiring diagrams, prepared for the model of chassis and body, will be provided. SABER FR CHASSIS The Pierce Saber FRO is the custom chassis developed exclusively for the fire service. Chassis provided will be a new, tilt-type custom fire apparatus. The chassis will be manufactured in the apparatus body builder's facility eliminating any split responsibility. The chassis will be designed and manufactured for heavy-duty service, with adequate strength, capacity for the intended load to be sustained, and the type of service required. The chassis will be the manufacturer's first line tilt cab. WHEELBASE The wheelbase of the vehicle will be 180.50. GVW RATING The gross vehicle weight rating will be 44,000#. FRAME The chassis frame will be built with two (2) steel channels bolted to five (5) cross members or more, depending on other options of the apparatus. The side rails will be heat-treated steel measuring 10.25" x 3.50" x 0.375". Each rail will have a section modulus of 16.00 cubic inches, yield strength of 120,000 psi, and a resisting bending moment (rbm) of 1,921,069 inch-pounds. FRONT AXLE The front axle will be a reverse "I" beam type with inclined king pins. It will be a Hendrickson SteerTekTM axle, with a rated capacity of 18,000 lb. FRONT SUSPENSION The front springs will be a Hendrickson, SteertekTM NXT, taper leaf design, with a ground rating of 18,000 lb. SHOCK ABSORBERS Hendrickson Steertek shock absorbers will be provided on the front axle. FRONT OIL SEALS Oil seals with viewing window will be provided on the front axle. FRONT TIRES Front tires will be Goodyear®315/80R22.50 radials, 20 ply G289 WHA tread, rated for 20,400 lb maximum axle load and 68 mph maximum speed. Port Arthur Stock Saber Pumper The tires will be mounted on Alcoa® 22.50" x 9.00" polished aluminum disc wheels with a ten (10) stud, 11.25" bolt circle. REAR AXLE The rear axle will be a Dana Model S23-190, single axle assembly with a capacity of 24,000 lb. TOP SPEED OF VEHICLE A rear axle ratio will be furnished to allow the vehicle to reach a top speed of 68 mph / 109 kph. REAR SUSPENSION The rear suspension will be Standens, semi-elliptical, 3.00" wide x 52.50" long, with a ground rating of 24,000 lb. The spring hangers will be castings. The two (2) top leaves will wrap the forward spring hanger pin, and the rear of the spring will be a slipper style end that will ride in a rear slipper hanger. A steel encased rubber bushing will be used in the spring eye. The steel encased rubber bushing will be maintenance free and require no lubrication. REAR OIL SEALS Oil seals will be provided on the rear axle(s). REAR TIRES The rear tires will be four(4) Goodyear Armor Max MSD, 12R22.50 radials, load range H, rated for 27,120 lb maximum axle load and 68 mph maximum speed. The tires will be mounted on Alcoa®22.50" x 9.00" polished aluminum disc wheels with a ten (10) stud, 11.25" bolt circle. TIRE BALANCE All tires will be balanced with Counteract balancing beads. The beads will be inserted into the tire and eliminate the need for wheel weights. TIRE PRESSURE MANAGEMENT There will be a RealWheels LED AirSecureTM tire alert pressure management system provided, that will monitor each tire's pressure. A sensor will be provided on the valve stem of each tire for a total of six (6)tires. The sensor will calibrate to the tire pressure when installed on the valve stem for pressures between 10 and 200 psi. The sensor will activate an integral battery operated LED when the pressure of that tire drops 5 to 8 psi. Removing the cap from the sensor will indicate the functionality of the sensor and battery. If the sensor and battery are in working condition, the LED will immediately start to flash. FRONT HUB COVERS Stainless steel hub covers will be provided on the front axle. An oil level viewing window will be provided. Port Arthur Stock Saber Pumper MUD FLAPS Mud flaps with a Pierce logo will be installed behind the front and rear wheels. WHEEL CHOCKS There will be one (1) pair of folding Ziamatic, Model SAC-44-E, aluminum alloy, Quick-Choc wheel blocks, with easy-grip handle provided. Wheel Chock Brackets There will be one (1) pair of Zico, Model SQCH-44-H, horizontal mounting wheel chock brackets provided for the Ziamatic, Model SAC-44-E, folding wheel chocks. The brackets will be made of aluminum and consist of a quick release spring loaded rod to hold the wheel chocks in place. The brackets will be mounted below the left side rear compartment. ELECTRONIC STABILITY CONTROL A vehicle control system will be provided as an integral part of the ABS brake system from Meritor Wabco. The system will monitor and update the lateral acceleration of the vehicle and compare it to a critical threshold where a side roll event may occur. If the critical threshold is met, the vehicle control system will automatically reduce engine RPM, engage the engine retarder (if equipped), and selectively apply brakes to the individual wheel ends of the front and rear axles to reduce the possibility of a side roll event. The system will monitor directional stability through a lateral accelerometer, steer angle sensor and yaw rate sensor. If spinout or drift out is detected, the vehicle control system will selectively apply brakes to the individual wheel ends of the front and rear axles to bring the vehicle back to its intended direction. ANTI-LOCK BRAKE SYSTEM The vehicle will be equipped with a Wabco 4S4M, anti-lock braking system. The ABS will provide a four (4) channel anti-lock braking control on both the front and rear wheels. A digitally controlled system that utilizes microprocessor technology will control the anti-lock braking system. Each wheel will be monitored by the system. When any wheel begins to lockup, a signal will be sent to the control unit. This control unit will then reduce the braking of that wheel for a fraction of a second and then reapply the brake. This anti-lock brake system will eliminate the lockup of any wheel thus helping to prevent the apparatus from skidding out of control. AUTOMATIC TRACTION CONTROL An anti-slip feature will be included with the ABS. The Automatic Traction Control will be used for traction in poor road and weather conditions. The Automatic Traction Control will act as an electronic differential lock that will not allow a driving wheel to spin, thereby supplying traction at all times. The ABS electronic control unit (ECU)will work with the engine ECU, sharing information concerning wheel slip. Engine ECU will use information to control engine speed, allowing only as much throttle application as required for the available traction, regardless of how much the driver is asking for. An "off road traction" switch will be provided on the instrument panel. Activation of the switch will allow additional tire slip to let the truck climb out and get on top of deep snow or mud. Port Arthur Stock Saber Pumper BRAKES The service brake system will be full air type by Bendix®. Front brakes will be Model ADB22XTM, disc type with automatic pad wear adjustment and 17.00" rotors for improved stopping distance. The rear brakes will be Bendix®, Model ES1657D, 16.50" x 7.00" cam operated with automatic slack adjusters. BRAKE SYSTEM AIR COMPRESSOR The air compressor will be a Cummins/WABCO with 18.7 cubic feet per minute output. BRAKE SYSTEM The brake system will include: • Brake treadle valve • Heated automatic moisture ejector on air dryer • Total air system minimum capacity of 4,272 cubic inches • Two (2) air pressure gauges with a red warning light and an audible alarm, that activates when air pressure falls below 60 psi • Spring set parking brake system • Parking brake operated by a push-pull style control valve • A parking "brake on" indicator light on instrument panel • Park brake relay/inversion and anti-compounding valve, in conjunction with a double check valve system, with an automatic spring brake application at 40 psi • A pressure protection valve to prevent all air operated accessories from drawing air from the air system when the system pressure drops below 80 psi (550 kPa) • 1/4 turn drain valves on each air tank The air tank will be primed and painted to meet a minimum 750 hour salt spray test. The air tanks will be painted same as frame color. To reduce the effects of corrosion, the air tank will be mounted with stainless steel brackets. BRAKE SYSTEM AIR DRYER The air dryer will be WABCO System Saver 1200 with spin-on coalescing filter cartridge and 100 watt heater. BRAKE LINES Color-coded nylon brake lines will be provided. The lines will be wrapped in a heat protective loom in the chassis areas that are subject to excessive heat. AIR INLET One (1) air inlet with 3D series male coupling will be provided. It will allow station air to be supplied to the apparatus brake system through a shoreline hose. The inlet will be located forward in the driver side lower step well of cab. A check valve will be provided to prevent reverse flow of air. The inlet will Port Arthur Stock Saber Pumper discharge into the "wet"tank of the brake system. A mating female fitting will also be provided with the loose equipment. ENGINE The chassis will be powered by an electronically controlled engine as described below: Make: Cummins Model: L9 Power 450 hp at 2100 rpm Torque: 1250 lb-ft at 1400 rpm Governed 2200 rpm Speed: Emissions Level: EPA 2024 Fuel: Diesel Cylinders: Six (6) Displacement: 543 cubic inches (8.9L) Starter: Delco 39MTTM Fuel Filters: Spin-on style primary filter with water separator and water-in-fuel sensor. Secondary spin-on style filter. The engine will include On-board diagnostics (OBD), which provides self diagnostic and reporting. The system will give the owner or repair technician access to state of health information for various vehicle sub systems. The system will monitor vehicle systems, engine and after treatment. The system will illuminate a malfunction indicator light on the dash console if a problem is detected. HIGH IDLE A high idle switch will be provided, inside the cab, on the instrument panel, that will automatically maintain a preset engine rpm. A switch will be installed, at the cab instrument panel, for activation/deactivation. The high idle will be operational only when the parking brake is on and the truck transmission is in neutral. A green indicator light will be provided, adjacent to the switch. The light will illuminate when the above conditions are met. The light will be labeled "OK to Engage High Idle." ENGINE BRAKE A Jacobs®engine brake is to be installed with the controls located on the instrument panel within easy reach of the driver. The driver will be able to turn the engine brake system on/off and have a high, medium and low setting. The engine brake will activate when the system is on and the throttle is released. The high setting of the brake application will activate and work simultaneously with the variable geometry turbo (VGT) provided on the engine. Port Arthur Stock Saber Pumper The engine brake will be installed in such a manner that when the engine brake is slowing the vehicle the brake lights are activated. The ABS system will automatically disengage the auxiliary braking device, when required. CLUTCH FAN A fan clutch will be provided. The fan clutch will be automatic when the pump transmission is in "Road" position, and constantly engaged when in "Pump" position. ENGINE AIR INTAKE The engine air intake will be located above the engine cooling package. It will draw fresh air from the front of the apparatus through the radiator grille. The ember separator is designed to prevent road dirt and recirculating hot air from entering the engine. The ember separator will be easily accessible by tilting the cab. EXHAUST SYSTEM The exhaust system will be stainless steel from the turbo to the engine's aftertreatment device. The exhaust system will include an aftertreatment device to meet current EPA standards. An insulation wrap will be provided on all exhaust pipe between the turbo and the aftertreatment device to minimize the transfer of heat to the cab. The exhaust will terminate horizontally ahead of the right side rear wheels and will extend 2.00" past the body rub rail. The exhaust pipes will be aluminized steel. There will be an aluminized steel exhaust diffuser with a standard straight tip on the end provided to reduce the temperature of the exhaust as it exits. Heat deflector shields will be provided to isolate chassis and body components from the heat of the tailpipe diffuser. RADIATOR The radiator and the complete cooling system will meet or exceed the current edition of applicable NFPA and engine manufacturer cooling system standards. For maximum corrosion resistance and cooling performance, the entire radiator core will be constructed using long life aluminum alloy. The radiator core will consist of aluminum fins, having a serpentine design, brazed to aluminum tubes. The radiator core will have a minimum front area of 1060 square inches. Supply tank will be made of heavy duty glass-reinforced nylon and the return tank will be made of aluminum. Both tanks will be crimped onto the core assembly using header tabs and a compression gasket to complete the radiator core assembly. There will be a full steel frame around the inserts to enhance cooling system durability and reliability. The radiator will be compatible with commercial antifreeze solutions. The radiator assembly will be isolated from the chassis frame rails with rubber isolators to prevent the development of leaks caused by twisting or straining when the apparatus operates over uneven terrain. Port Arthur Stock Saber Pumper The radiator will include a de-aeration/expansion tank. For visual coolant level inspection, the radiator will have a built-in sight glass. The radiator will be equipped with a 15 psi pressure relief cap. A drain port will be located at the lowest point of the cooling system and/or the bottom of the radiator to permit complete flushing of the coolant from the system. Shields or baffles will be provided to prevent recirculation of hot air to the inlet side of the radiator. COOLANT LINES Gates, or Goodyear, rubber hose will be used for all engine coolant lines installed by Pierce Manufacturing. Hose clamps will be stainless steel constant torque type to prevent coolant leakage. They will expand and contract according to coolant system temperature thereby keeping a constant clamping pressure on the hose. FUEL TANK A 65 gallon fuel tank will be provided and mounted at the rear of the chassis. The tank will be constructed of 12-gauge, hot rolled steel. It will be equipped with swash partitions and a vent. To eliminate the effects of corrosion, the fuel tank will be mounted with stainless steel straps. A 0.75" drain plug will be located in a low point of the tank for drainage. A fill inlet will be located on the left hand side of the body and is covered with a hinged, spring loaded, stainless steel door that is marked "Ultra Low Sulfur- Diesel Fuel Only." A 0.50"diameter vent will be installed from tank top to just below fuel fill inlet. The fuel tank will meet all FHWA 393.67 requirements including a fill capacity of 95 percent of tank volume. All fuel lines will be provided as recommended by the engine manufacturer. DIESEL EXHAUST FLUID TANK A 4.5 gallon diesel exhaust fluid (DEF) tank will be provided and mounted in the left side body forward of the rear axle. A 0.50" drain plug will be provided in a low point of the tank for drainage. A fill inlet will be located on the left side of the body and be covered with a hinged, spring loaded, polished stainless steel door that is marked "Diesel Exhaust Fluid Only". The tank will meet the engine manufacturers requirement for 10 percent expansion space in the event of tank freezing. The tank will include an integrated heater unit that utilizes engine coolant to thaw the DEF in the event of freezing. Port Arthur Stock Saber Pumper FUEL PRIMING PUMP A Cummins automatic electronic fuel priming pump will be integrated as part of the engine. TRANSMISSION An Allison 6th generation, Model EVS 3000P, electronic torque converting automatic transmission will be provided. The transmission will be equipped with prognostics to monitor oil life, filter life, and transmission health. A wrench icon on the shift selector's digital display will indicate when service is due. Two (2) PTO openings will be located on both sides of converter housing (positions 4 o'clock and 8 o'clock) as viewed from the rear. A transmission temperature gauge with amber light and audible alarm will be installed on the cab dash. TRANSMISSION SHIFTER A five (5)-speed push button shift module will be mounted to right of driver on console. Shift position indicator will be indirectly lit for after dark operation. The transmission ratio will be: 1st 3.49 to 1.00 2nd 1.86 to 1.00 3rd 1.41 to 1.00 4th 1.00 to 1.00 5th 0.75 to 1.00 R 5.03 to 1.00 TRANSMISSION COOLER A Modine plate and fin transmission oil cooler will be provided using engine coolant to control the transmission oil temperature. DRIVELINE Drivelines will be a heavy-duty metal tube and be equipped with Spicer® 1710 universal joints. The shafts will be dynamically balanced before installation. A splined slip joint will be provided in each driveshaft where the driveline design requires it. The slip joint will be coated with Glidecoat®or equivalent. STEERING Dual steering gear, with integral heavy-duty power steering, will be provided. For reduced system temperatures, the power steering will incorporate an air to oil cooler and Vickers®V20NF hydraulic pump with integral pressure and flow control. All power steering lines will have wire braded lines with crimped fittings. Port Arthur Stock Saber Pumper A tilt and telescopic steering column will be provided to improve fit for a broader range of driver configurations. STEERING WHEEL The steering wheel will be 18.00" in diameter, have tilting and telescoping capabilities, and a 4-spoke design. BUMPER A one (1) piece bumper manufactured from 0.25" formed steel with a 0.38" bend radius will be provided. The bumper will be a minimum of 10.00" high with a 1.50" top and bottom flange, and will extend 19.00" from the face of the cab. The bumper will be 95.28" wide with 45 degree corners and side plates. The bumper will be metal finished and painted to match the lower. To provide adequate support strength, the bumper will be mounted directly to the front of the C channel frame. The frame will be a bolted modular extension frame constructed of 50,000 psi tensile steel. Gravel Pan A gravel pan, constructed of bright aluminum treadplate, will be furnished between the bumper and the cab face. The pan will be properly supported from the underside to prevent flexing and vibration. CENTER HOSE TRAY A hose tray, constructed of aluminum, will be placed in the center of the bumper extension. The tray will have a capacity of 125' of 1.75" double jacket cotton-polyester hose. Black rubber grating will be provided at the bottom of the tray. Drain holes are also provided. Center Hose Tray Restraint There will be one (1) pair of hose tray restraint straps located over the center mounted tray. The restraints will be a pair of 2.00" wide black nylon straps with Velcro®fasteners provided. The strap(s) will be used to secure the hose in the tray. TOW HOOKS Two (2) chromed steel tow hooks will be installed under the bumper and attached to the front frame members. The tow hooks will be designed and positioned to allow up to a 6,000 lb straight horizontal pull in line with the centerline of the vehicle. The tow hooks will not be used for lifting of the apparatus. FRONT BUMPER NOTCH The front bumper will be notched for recessing of the Q2B siren. The notch will be designed so that the bumper is one continuous piece. The notch will be welded in place for strength with a continuous top and bottom flange. All welds will be metal finished for appearance. The siren will be located DS of the bumper. CAB The cab will be designed specifically for the fire service and manufactured by the chassis builder. The cab will be built by the apparatus manufacturer in a facility located on the manufacturer's premises. Port Arthur Stock Saber Pumper For reasons of structural integrity and enhanced occupant protection, the cab will be a heavy duty design, constructed to the following minimal standards. The cab will have 12 main vertical structural members located in the A-pillar (front cab corner posts), B- pillar (side center posts), C-pillar (rear corner posts), and rear wall areas. The A-pillar will be constructed of solid A356-T5 aluminum castings. The B-pillar and C-pillar will be constructed from 0.13" wall extrusions. The rear wall will be constructed of two (2) 2.00" x 2.00" outer aluminum extrusions and two (2) 2.00" x 1.00" inner aluminum extrusions. All main vertical structural members will run from the floor to 4.625" x 3.864" x 0.090" thick roof extrusions to provide a cage-like structure with the A-pillar and roof extrusions being welded into a 0.25" thick corner casting at each of the front corners of the roof assembly. The front of the cab will be constructed of a 0.13" firewall plate, covered with a minimum 0.090"front skin thickness, and reinforced with a full width x 0.50" thick cross-cab support ~� located just below the windshield and fully welded to the engine I tunnel. The cross-cab support will run the full width of the cab and weld to each A-pillar, the 0.13" firewall plate, and the front skin. • The cab floors will be constructed of 0.125"thick aluminum plate and reinforced at the firewall with an additional 0.25" thick cross- floor support providing a total thickness of 0.375" of structural S material at the front floor area. The front floor area will also be supported with two (2) triangular 0.30" wall extrusions that also provides the mounting point for the cab lift. This tubing will run from the floor wireway of the cab to the engine tunnel side plates, creating the structure to support the forces created when lifting the cab. The cab will be 96.00" wide (outside door skin to outside door skin)to maintain maximum maneuverability. The centerline of front axle to the rear of the cab will be 70.00" long. The forward cab section will have an overall height (from the cab roof to the ground) of approximately 99.00". The crew cab section will have a 10.00" raised roof, with an overall cab height of approximately 109.00". The overall height listed will be calculated based on a truck configuration with the lowest suspension weight rating, the smallest diameter tires for the suspension, no water weight, no loose equipment weight, and no personnel weight. Larger tires, wheels, and suspension will increase the overall height listed. The floor to ceiling height inside the crew cab will be 64.50" in the center and outboard positions. The crew cab floor will measure 46.00" from the rear wall to the front of the rear facing seat risers. The engine tunnel, at the rearward highest point (knee level), will measure 61.50" to the rear wall. Port Arthur Stock Saber Pumper The crew cab will be a totally enclosed design with the interior area completely open to improve visibility and verbal communication between the occupants. The cab will be a full tilt cab style. A 3-point cab mount system with rubber isolators will improve ride quality by isolating chassis vibrations from the cab. CAB ROOF DRIP RAIL For enhanced protection from inclement weather, a drip rail will be furnished on the sides of the cab. The drip rail will be secured to the sides of the cab with a tape adhesive. The drip rail will extend the full length of the cab roof. FENDER LINERS Full circular inner fender liners in the wheel wells will be provided. PANORAMIC WINDSHIELD "* -- `" A 1-piece safety glass windshield will be provided with over 2,775 square inches of clear viewing area. The windshield will be full width and will provide the occupants with a panoramic view. The windshield will consist of three (3) layers: outer light, middle safety laminate, and inner light. The outer light layer will FiRErasscti provide superior chip resistance. The middle safety laminate layer will prevent the windshield glass pieces from detaching in the event of breakage. The inner light will provide yet another chip resistant layer. The cab windshield will be bonded to the aluminum windshield frame using a urethane adhesive. A custom frit pattern will be applied on the outside perimeter of the windshield for a finished automotive appearance. WINDSHIELD WIPERS Three (3) electric windshield wipers with washer will be provided that meet FMVSS and SAE requirements. The washer reservoir will be able to be filled without raising the cab. Port Arthur Stock Saber Pumper ` riarif A' N $ NMI" ENGINE TUNNEL Engine hood side walls will be constructed of 0.375" aluminum. The top will be constructed of 0.125" aluminum and will be tapered at the top to allow for more driver and passenger elbow room. The engine hood will be insulated for protection from heat and sound. The noise insulation keeps the dBA level within the limits stated in the current edition of applicable NFPA standards. The engine tunnel will be no higher than 17.00" off the crew cab floor. • is ay 1T 00" k_ v \ �a CAB INSULATION The cab will include 1.00" insulation in the ceiling, 1.50" insulation in the side walls, a minimum of 1.00" insulation in the crew cab floor, and 2.00" insulation in the rear wall to maximize acoustic absorption and thermal insulation. Port Arthur Stock Saber Pumper INTERIOR CREW CAB REAR WALL ADJUSTABLE SEATING (PATENT PENDING) The interior rear wall of the crew cab will have mounting holes every 2.75"to allow for adjustability of the forward facing crew cab seating along the rear wall. Seats will be adjustable with use of simple hand tools allowing departments flexibility of their seating arrangement should their department needs change. NI i IIt t 1 iff rE. -, ,,,... . i Ili ' .: -,, A '' -- CAB REAR WALL EXTERIOR COVERING The exterior surface of the rear wall of the cab will be overlaid with bright aluminum treadplate except for areas that are not typically visible when the cab is lowered. CAB LIFT A hydraulic cab lift system will be provided consisting of an electric powered hydraulic pump, dual lift cylinders, and necessary hoses and valves. Lift controls will be located on the right side pump panel or a front area of the body in a convenient location. rr= = y- The cab will be capable of tilting 43 degrees to PA. .�_....,� accommodate engine maintenance and removal. I &CTIVATIP The cab will be locked down by a 2-point normally closed spring loaded hook type latch that fully engages after the cab has been lowered. The system will be hydraulically actuated to release the normally .. , t closed locks when the cab lift control is in the raised position and cab lift `$ ci system is under pressure. When the cab is completely lowered and system pressure has been relieved, the spring loaded latch mechanisms will return to a the normally closed and locked position. I ` Port Arthur Stock Saber Pumper The hydraulic cylinders will be equipped with a velocity fuse that protects the cab from accidentally descending when the control is located in the tilt position. For increased safety, a redundant mechanical stay arm will be provided that must be manually put in place on the left side between the chassis and cab frame when the cab is in the raised position. This device will be manually stowed to its original position before the cab can be lowered. Cab Lift Interlock The cab lift system will be interlocked to the parking brake. The cab tilt mechanism will be active only when the parking brake is set and the ignition switch is in the on position. If the parking brake is released, the cab tilt mechanism will be disabled. GRILLE A single piece polished stainless steel grille and framework will be provided on the front center of the cab. SIDE OF CAB MOLDING Chrome molding will be provided on both sides of cab. MIRRORS A Retrac, Model 613423, dual vision, motorized, west coast style mirror, with chrome finish, will be mounted on each side of the front cab door with spring loaded retractable arms. The flat glass and convex glass will be heated and adjustable with remote control within reach of the driver. FRONT CROSS VIEW MIRROR An 8.00" diameter convex mirror will be provided over the officer's side front corner of the cab. The mirror will provide the driver with a view of the front bumper and the area several feet in front of the truck. The mirror housing, tubing, clamps, and hardware will be constructed of corrosion resistant stainless steel. DOORS To enhance entry and egress to the cab, the forward cab door openings will be a minimum of 37.50" wide x 63.37" high. The crew cab doors will be located on the sides of the cab and will be constructed in the same manner as the forward cab doors. The crew cab door openings will be a minimum of 34.30"wide x 73.25" high. The forward cab and crew cab doors will be constructed of extruded aluminum with a nominal material thickness of 0.093". The exterior door skins will be constructed from 0.090" aluminum. A customized, vertical, pull-down type door handle will be provided on the exterior of each cab door. The finish of the door handle will be chrome/black. The exterior handle will be designed specifically for the fire service to prevent accidental activation, and will provide 4.00" wide x 2.00" deep hand clearance for ease of use with heavy gloved hands. Port Arthur Stock Saber Pumper ) III i iottr I ' I 1'1 14: [Exterior Door Handle] Each door will also be provided with an interior flush, open style paddle handle that will be readily operable from fore and aft ---°- ------_ positions, and be designed to prevent accidental activation. The F_ interior handles will provide 4.00"wide x 1.25" deep hand clearance for ease of use with heavy gloved hands. i The cab doors will be provided with both interior(rotary knob) and exterior(keyed) locks exceeding FMVSS standards. The keys will be Model 751. The locks will be capable of activating when the doors are open or closed. The doors will remain locked [Interior Door Handle] if locks are activated when the doors are opened, then closed. A full length, heavy duty, stainless steel, piano-type hinge with a 0.38" pin and 11 gauge leaf will be provided on all cab doors. There will be double automotive-type rubber seals around the perimeter of the door framing and door edges to ensure a weather-tight fit. A chrome grab handle will be provided on the inside of each cab door for ease of entry. A red webbed grab handle will be installed on the crew cab door stop strap. The grab handles will be securely mounted. The bottom cab step at each cab door location will be located below the cab doors and will be exposed to the exterior of the cab. Door Panels The inner cab door panels will be constructed out of brushed stainless steel. ELECTRIC OPERATED CAB DOOR WINDOWS The two (2)front cab doors will be equipped with electric operated windows with one (1)flush mounted automotive style switch on each of the front doors. The driver's door will have two (2) switches, one (1) to control each for the driver and officer door windows. The crew cab door windows will be controlled manually. Each switch will allow intermittent or auto down operation for ease of use. Auto down operation will be actuated by holding the window down switch for approximately 1 second. CAB STEPS Port Arthur Stock Saber Pumper The forward cab and crew cab access steps will be a full size two (2) step design to provide largest possible stepping surfaces for safe ingress and > egress. The bottom steps will be designed with a grip pattern punched into 1 _ bright aluminum treadplate material to provide support, slip resistance, and drainage. The bottom steps will be a bolt-in design to minimize repair costs =: w should they need to be replaced. The forward cab steps will be a minimum y.. 25.00"wide, and the crew cab steps will be 21.65" wide with a 10.00" _ minimum depth. The inside cab steps will not exceed 16.50" in height. The vertical surfaces of the step well will be aluminum treadplate. I CAB EXTERIOR HANDRAILS A 1.25" diameter slip-resistant, knurled aluminum handrail will be provided adjacent to each cab and crew cab door opening to assist during cab ingress and egress. STEP LIGHTS There will be six (6)white LED step lights with chrome housing installed for cab and crew cab access steps. • One (1) light for the left side cab access steps. • Two (2) lights for the left side crew cab access steps. • Two (2) lights for the right side crew cab access steps. • One (1) light for the right side cab access step. In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles (fc) covering an entire 15" x 15" square placed ten (10) inches below the light and a minimum of 1.5 fc covering an entire 30" x 30" square at the same ten (10) inch distance below the light. The lights will be activated when the battery switch is on and the adjacent door is opened. FENDER CROWNS Stainless steel fender crowns will be installed at the cab wheel openings. ADDITIONAL HANDRAIL There will be two (2) handrail(s) provided one each side back of cab, to assist stepping on running board and accessing the crosslays. The handrail will be an anodized aluminum extrusion with a ribbed design to provide a positive gripping surface. CREW CAB WINDOWS 44. r One (1) fixed window with tinted glass will be provided on each side of the cab, to the rear of the front cab door. The windows will be sized to enhance light 1 - ° penetration into the cab interior. The windows will measure 18.70" wide x 23.75" , high with chrome window trim. Port Arthur Stock Saber Pumper CAB DASH The driver side dash, switch panel located to the right of the driver, and center console will be an easily removable high impact resistant polymer cover. The instrument gauge cluster will be surrounded with a high impact ABS plastic contoured to the same shape of the instrument gauge cluster. The officer side dash will be a flat top design with an upper beveled edge to provide easy maintenance and will be constructed out of aluminum and painted to match the cab interior. MOUNTING PLATE ON ENGINE TUNNEL Equipment installation provisions will be installed on the engine tunnel. A 0.188" smooth aluminum plate will be bolted to the top surface of the engine tunnel. The plate will follow the contour of the engine tunnel and will run the entire length of the engine tunnel. The plate will be spaced off the engine tunnel 1.00" to allow for wire routing below the plate. The mounting surface will be painted to match the cab interior. CAB INTERIOR The cab interior will be constructed of primarily metal (painted aluminum)to withstand the severe duty cycles of the fire service. The engine tunnel will be painted aluminum to match the cab interior. For durability and ease of maintenance, the cab interior side walls will be painted aluminum. The rear wall will be painted aluminum. The headliner will be installed in both forward and rear cab sections. Headliner material will be vinyl. A sound barrier will be part of its composition. Material will be installed on an aluminum sheet and securely fastened to interior cab ceiling. The forward portion of the cab headliner will permit easy access for service of electrical wiring or other maintenance needs. All wiring will be placed in metal raceways. CAB INTERIOR UPHOLSTERY The cab interior upholstery will be 36 oz dark silver gray vinyl. CAB INTERIOR PAINT The cab interior metal surfaces, excluding the rear heater panels, will be painted fire smoke gray, vinyl texture paint. The rear heater panels will be painted black, vinyl textured paint. CAB FLOOR The cab and crew cab floor areas will be covered with PolydampTM acoustical floor mat consisting of a black pyramid rubber facing and closed cell foam decoupler. Port Arthur Stock Saber Pumper The top surface of the material has a series of raised pyramid shapes evenly spaced, which offer a superior grip surface. Additionally, the material has a 0.25" thick closed cell foam (no water absorption) which offers a sound dampening material for reducing sound levels. DEFROST/AIR CONDITIONING SYSTEM A ceiling mounted combination heater, defroster and air conditioning system will be installed in the cab above the engine tunnel area. Cab Defroster A 54,000 BTU heater-defroster unit with 690 SCFM of air flow will be provided inside the cab. The heater-defrost will be installed in the forward portion of the cab ceiling. Air outlets will be strategically located in the cab header extrusion per the following: • One (1) adjustable will be directed towards the left side cab window • One (1) adjustable will be directed towards the right side cab window • Six (6)fixed outlets will be directed at the windshield The defroster will be capable of clearing 98 percent of the windshield and side glass when tested under conditions where the cab has been cold soaked at 0 degrees Fahrenheit for 10 hours, and a 2 ounce per square inch layer of frost/ice has been able to build up on the exterior windshield. The defroster system will meet or exceed SAE J382 requirements. Cab/Crew Auxiliary Heater There will be one (1) 31,000 BTU auxiliary heater with 560 SCFM of air flow provided in each outboard rear facing seat riser with a dual scroll blower. An aluminum plenum incorporated into the cab structure to be used to transfer heat to the forward positions. Air Conditioning A condenser will be a 59,644 BTU output that meets and exceeds the performance specification will be mounted on the radiator. The air conditioning system will be capable of cooling the average cab temperature from 100 degrees Fahrenheit to 75 degrees Fahrenheit at 50 percent relative humidity within 30 minutes. The cooling performance test will be run only after the cab has been heat soaked at 100 degrees Fahrenheit for a minimum of 4 hours. The evaporator unit will be installed in the rear portion of the cab ceiling over the engine tunnel. The evaporator will include one (1) high performance heating core, one (1) high performance cooling core with (1) plenum directed to the front and one (1) plenum directed to the rear of the cab. The rear plenum will be covered with [Plenum Cover Material]. The evaporator unit will have a 52,000 BTU at 690 SCFM rating that meets and exceeds the performance specifications. Adjustable air outlets will be strategically located on the forward plenum cover per the following: • Four(4)will be directed towards the seating position on the left side of the cab Port Arthur Stock Saber Pumper • Four (4)will be directed towards the seating position on the right side of the cab Adjustable air outlets will be strategically located on the evaporator cover per the following: • Five (5) will be directed towards crew cab area A high efficiency particulate air (HEPA)filter will be included for the system. Access to the filter cover will be secured with four(4) screws. The air conditioner refrigerant will be R-134A and will be installed by a certified technician. Climate Control An automotive style controller will be provided to control the heat and air conditioning system within the cab. The controller will have three (3)functional knobs for fan speed, temperature, and air flow distribution (front to rear) control. (Th The system will control the temperature of the cab and crew cab automatically by pushing the center of the fan speed control knob. Rotate the center temperature control knob to set the cab and crew cab temperature. The AC system will be manually activated by pushing the center of the temperature control knob. Pushing the center of the air flow distribution knob will engage the AC for max defrost, setting the fan speeds to 100 percent and directing all air flow to the overhead forward position. The system controller will be located within panel position #12. Gravity Drain Tubes Two (2) condensate drain tubes will be provided for the air conditioning evaporator. The drip pan will have two (2) drain tubes plumbed separately to allow for the condensate to exit the drip pan. No pumps will be provided. SUN VISORS Two (2) smoked LexanTM sun visors will be provided. The sun visors will be located above the windshield with one (1) mounted on each side of the cab. There will be no retention bracket provided to help secure each sun visor in the stowed position. Port Arthur Stock Saber Pumper GRAB HANDLES A black rubber covered grab handle will be mounted on the door post of the driver and officer's side cab door to assist in entering the cab. The grab handles will be securely mounted to the post area between the door and windshield. At a m �hx g }S i I I ENGINE COMPARTMENT LIGHTS There will be one (1) Whelen®, Model 3SC0CDCR, 12 volt DC, 3.00"white LED light(s)with Model 3FLANGEC, chrome flange kit(s) installed under the cab to be used as engine compartment illumination. These light(s) will be activated automatically when the cab is raised or when the dip stick door is opened. ACCESS TO ENGINE DIPSTICKS [ ' For access to the engine oil and transmission fluid dipsticks, there will be a door on the engine tunnel, inside the crew cab. : ' r < y The door will be on the rear wall of the engine tunnel, on the vertical surface. ;, The engine oil dipstick will allow for checking only. The '54transmission dipstick will allow for both checking and filling. The door will have a rubber seal for thermal and acoustic insulation. One (1)flush lift and turn latch will be provided on the access door. CAB SAFETY SYSTEM The cab will be provided with a safety system designed to protect occupants in the event of a side roll or frontal impact, and will include the following: • A supplemental restraint system (SRS) sensor will be installed on a structural cab member behind the instrument panel. The SRS sensor will perform real time diagnostics of all critical subsystems and will record sensory inputs immediately before and during a side roll or frontal impact event. Port Arthur Stock Saber Pumper • A fault-indicating light will be provided on the vehicle's instrument panel allowing the driver to monitor the operational status of the SRS system. • A driver side front air bag will be mounted in the steering wheel and will be designed to protect the head and upper torso of the occupant, when used in combination with the 3-point seat belt. • A passenger side knee bolster air bag will be mounted in the modesty panel below the dash panel and will be designed to protect the legs of the occupant, when used in combination with the 3-point seat belt. • Air curtains will be provided in the outboard bolster of outboard seat backs to provide a cushion between occupant and the cab wall. • Suspension seats will be provided with devices to retract them to the lowest travel position during a side roll or frontal impact event. • Seat belts will be provided with pre-tensioners to remove slack from the seat belt during a side roll or frontal impact event (with the exception of command chairs located in the command cab). Frontal Impact Protection The SRS system will provide protection during a frontal or oblique impact event. The system will activate when the vehicle decelerates at a predetermined G force known to cause injury to the occupants. The cab and chassis will have been subjected, via third party test facility, to a crash impact during frontal and oblique impact testing. Testing included all major chassis and cab components such as mounting straps for fuel and air tanks, suspension mounts, front suspension components, rear suspensions components, frame rail cross members, engine and transmission and their mounts, pump house and mounts, frame extensions and body mounts. The testing provided configuration specific information used to optimize the timing for firing the safety restraint system. The sensor will activate the pyrotechnic devices when the correct crash algorithm, wave form, is detected. The SRS system will deploy the following components in the event of a frontal or oblique impact event: • Driver side front air bag • Passenger side knee bolster air bag • Air curtains mounted in the outboard bolster of outboard seat backs • Suspension seats will be retracted to the lowest travel position • Seat belts will be pre-tensioned to firmly hold the occupant in place Side Roll Protection The SRS system will provide protection during a fast or slow 90 degree roll to the side, in which the vehicle comes to rest on its side. The system will analyze the vehicle's angle and rate of roll to determine the optimal activation of the advanced occupant restraints. The SRS system will deploy the following components in the event of a side roll: • Air curtains mounted in the outboard bolster of outboard seat backs • Suspension seats will be retracted to the lowest travel position • Seat belts will be pre-tensioned to firmly hold the occupant in place Port Arthur Stock Saber Pumper SEATING CAPACITY The seating capacity of the vehicle (including tiller cab and belted seat positions in the rescue body) will be six (6). DRIVER SEAT A seat will be provided in the cab for the driver. The seat design will be a cam action type, with air suspension. For increased convenience, the seat will include a manual control to adjust the horizontal position (6.00" travel). The manual horizontal control will be a towel-bar style located below the forward part of the seat cushion. To provide flexibility for multiple driver configurations, the seat will have an adjustable reclining back. The seat back will be a high back style with side bolster pads for maximum support. For optimal comfort, the seat will be provided with 17.00" deep foam cushions designed with EVC (elastomeric vibration control). The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A suspension seat safety system will be included. When activated in the event of a side roll, this system will pretension the seat belt and retract the seat to its lowest travel position. The seat will be furnished with a 3-point, shoulder type seat belt. OFFICER SEAT A seat will be provided in the cab for the passenger. The seat will be a fixed type, with no suspension. For optimal comfort, the seat will be provided with 17.00" deep foam cushions designed with EVC (elastomeric vibration control). The seat back will be an SCBA back style with 95 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt. The seat will be furnished with a 3-point, shoulder type seat belt. RADIO COMPARTMENT A radio compartment will be provided under the officer's seat. The inside compartment dimensions will be 14.00" wide x 7.50" high x 15.00" deep, with the back of the compartment angled up to match the cab structure. A drop-down door with one (1) lift and turn latch will be provided for access. Port Arthur Stock Saber Pumper The compartment will be constructed of smooth aluminum and painted to match the cab interior. REAR FACING DRIVER SIDE OUTBOARD SEAT There will be one (1) rear facing seat provided at the driver side outboard position in the crew cab. For optimal comfort, the seat will be provided with 15.00" deep foam cushions designed with EVC (elastomeric vibration control). The seat back will be an SCBA back style with 95 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt. The seat will be furnished with a 3-point, shoulder type seat belt. REAR FACING PASSENGER SIDE OUTBOARD SEAT There will be one (1) rear facing seat provided at the passenger side outboard position in the crew cab. For optimal comfort, the seat will be provided with 15.00" deep foam cushions designed with EVC (elastomeric vibration control). The seat back will be an SCBA back style with 95 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt. The seat will be furnished with a 3-point, shoulder type seat belt. FORWARD FACING DRIVER SIDE OUTBOARD SEAT There will be one (1) forward facing, foldup seat provided at the driver side outboard position in the crew cab. For optimal comfort, the seat will be a minimum of 15.00" from the front of the cushion to the face of the seat back and designed with EVC (elastomeric vibration control). The seat back will be an SCBA style with 90 degree back. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: Port Arthur Stock Saber Pumper • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt around the occupant to firmly hold them in place in the event of a side roll. The seat will be furnished with a 3-point, shoulder type seat belt. FORWARD FACING CENTER CABINET A forward facing cabinet will be provided in the crew cab at the center position. The cabinet will be 38.50" wide x 60.00" high x 28.00" deep with one (1)Amdor rollup door with anodized finish, locking with #751 key. The frame to frame opening of the cabinet will be 36.00"wide x 54.75" high. The minimum clear door opening will be 33.25" wide x 48.87" high. CLEAR DOOR OPENINGS (F-F=Frame to Frame) AMDOR GORTITE ROM HORIZONTAL VERTICAL HORIZONTAL VERTICAL HORIZONTAL VERTICAL Subtract 2.00" Subtract 5.88" Subtract 2.75" Subtract 4.75" Subtract 2.56" Subtract 4.50" from F-F from F-F from F-F from F-F from F-F from F-F The cabinet will include two (2) infinitely adjustable shelves with a 1.25" up-turned lippainted to match the cab interior. The cabinet will include no louvers. The cabinet will be constructed of smooth aluminum, and painted to match the cab interior. Cabinet Light There will be one (1) red Amdor LED strip light installed on the left side of the interior cabinet door opening and one (1) red Amdor LED strip light installed on the right side of the interior cabinet door opening. The lighting will be controlled by an automatic door switch. FORWARD FACING PASSENGER SIDE OUTBOARD SEAT There will be one (1)forward facing, foldup seat provided at the passenger side outboard position in the crew cab. For optimal comfort, the seat will be a minimum of 15.00"from the front of the cushion to the face of the seat back and designed with EVC (elastomeric vibration control). The seat back will be an SCBA style with 90 degree back. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt around the occupant to firmly hold them in place in the event of a side roll. Port Arthur Stock Saber Pumper The seat will be furnished with a 3-point, shoulder type seat belt. SEAT UPHOLSTERY All seat upholstery will be leather grain 36 oz dark silver gray vinyl resistant to oil, grease and mildew. The cab and tiller cab (if applicable)will have six (6) seating positions. AIR BOTTLE HOLDERS All SCBA type seats in the cab will have a "Hands-Free" auto clamp style bracket in its backrest. For efficiency and convenience, the bracket will include an automatic spring clamp that allows the occupant to store the SCBA bottle by simply pushing it into the seat back. For protection of all occupants in the cab, in the event of an accident, the inertial components within the clamp will constrain the SCBA bottle in the seat and will exceed the NFPA standard of 9G. There will be a quantity of five (5) SCBA brackets. SEAT BELTS All cab and tiller cab (if applicable) seating positions will have red seat belts. To provide quick, easy use for occupants wearing bunker gear, the female buckle and seat belt webbing length will meet or exceed the current edition of applicable NFPA and CAN/ULC -S515 standards. The 3-point shoulder type seat belts will include height adjustment. This adjustment will optimize the belts effectiveness and comfort for the seated firefighter. The 3-point shoulder type seat belts will be furnished with dual automatic retractors that will provide ease of operation in the normal seating position. The 3-point shoulder type belts will also include the ReadyReach® D-loop assembly to the shoulder belt system. The ReadyReach feature adds an extender arm to the D-loop location placing the D-loop in a closer, easier to reach location. Any flip up seats will include 3-point shoulder type belts only. To ensure safe operation, the seats will be equipped with seat belt sensors in the seat cushion and belt receptacle that will activate an alarm indicating a seat is occupied but not buckled. HELMET STORAGE PROVIDED BY FIRE DEPARTMENT NFPA 1900, 2024 edition, section 11.1.8.4.1 and CAN/ULC 515:2024 edition, section 5.2, requires a location for helmet storage be provided. There is no helmet storage on the apparatus as manufactured. The fire department will provide a location for storage of helmets. CAB DOME LIGHTS There will be four(4) dual LED dome lights with black bezels provided. Two (2) lights will be mounted above the inside shoulder of the driver and officer and two (2) lights will be installed and located, one (1) on each side of the crew cab. The color of the LED's will be red and white. Port Arthur Stock Saber Pumper The white LED's will be controlled by the door switches and the lens switch. The color LED's will be controlled by the lens switch. All dome lights on the apparatus will be illuminated per the current edition of applicable NFPA standards per seating position. PORTABLE HAND LIGHTS PROVIDED BY FIRE DEPARTMENT The hand lights are not on the apparatus as manufactured. The fire department will provide and mount these hand lights. CAB INSTRUMENTATION The cab instrument panel will include gauges, telltale indicator lamps, control switches, alarms, and a diagnostic panel. The function of the instrument panel controls and switches will be identified by a label adjacent to each item. Actuation of the headlight switch will illuminate the labels in low light conditions. Telltale indicator lamps will not be illuminated unless necessary. The cab instruments and controls will be conveniently located within the forward cab section, forward of the driver. The gauge assembly and switch panels are designed to be removable for ease of service and low cost of ownership. Gauges The gauge panel will include the following ten (10) black faced gauges with black bezels to monitor vehicle performance: • Voltmeter gauge (volts): o Low volts (11.8 VDC) • Amber telltale light on indicator light display with steady tone alarm o High volts (15.5 VDC) • Amber telltale light on indicator light display with steady tone alarm • Engine Tachometer (RPM) • Speedometer MPH (Major Scale), KM/H (Minor Scale) • Fuel level gauge (Empty - Full in fractions): o Low fuel (1/8 full) • Amber indicator light in gauge dial with steady tone alarm • Engine Oil pressure Gauge (PSI): o Low oil pressure to activate engine warning lights and alarms • Red indicator light in gauge dial with steady tone alarm • Front Air Pressure Gauges (PSI): o Low air pressure to activate warning lights and alarm • Red indicator light in gauge dial with steady tone alarm • Rear Air Pressure Gauges (PSI): o Low air pressure to activate warning lights and alarm • Red indicator light in gauge dial with steady tone alarm • Transmission Oil Temperature Gauge (Fahrenheit): o High transmission oil temperature activates warning lights and alarm • Amber indicator light in gauge dial with steady tone alarm • Engine Coolant Temperature Gauge (Fahrenheit): Port Arthur Stock Saber Pumper o High engine temperature activates an engine warning light and alarms • Red indicator light in gauge dial with steady tone alarm • Diesel Exhaust Fluid Level Gauge (Empty - Full in fractions): o Low fluid (1/8 full) • Amber indicator light in gauge dial Indicator Lamps To promote safety, the following telltale indicator lamps will be located on the instrument panel in clear view of the driver. The indicator lamps will be "dead-front" design that is only visible when active. The colored indicator lights will have descriptive text or symbols. The following amber telltale lamps will be present: • Low coolant • Trac cntl (traction control) (where applicable) • Check engine • Check trans (check transmission) • Air rest (air restriction) • DPF (engine diesel particulate filter regeneration) • HET (engine high exhaust temperature) (where applicable) • ABS (antilock brake system) • MIL (engine emissions system malfunction indicator lamp) (where applicable) • Regen inhibit (engine emissions regeneration inhibit) (where applicable) • Side roll fault (where applicable) • Front air bag fault (where applicable) • Aux brake overheat (auxiliary brake overheat) (where applicable) • The following red telltale lamps will be present: • Ladder rack down • Parking brake • Stop engine • The following green telltale lamps will be present: • Left turn • Right turn • Battery on • Ignition • Aux brake (auxiliary brake engaged) (where applicable) • The following blue telltale lamps will be present: • High beam Alarms Audible steady tone warning alarm: A steady audible tone alarm will be provided whenever a warning condition is active. Port Arthur Stock Saber Pumper Indicator Lamp and Alarm Prove-Out A system will be provided which automatically tests telltale indicator lights and alarms located on the cab instrument panel. Telltale indicators and alarms will perform prove-out for 3 to 5 seconds when the ignition switch is moved to the on position with the battery switch on. Control Switches For ease of use, the following controls will be provided immediately adjacent to the cab instrument panel within easy reach of the driver. All switches will have backlit labels for low light applications. Headlight/Parking light switch: A three (3)-position maintained rocker switch will be provided. The first switch position will deactivate all parking and headlights. The second switch position will activate the parking lights. The third switch will activate the headlights. Panel back lighting intensity control switch: A three (3)-position momentary rocker switch will be provided. Pressing the top half of the switch, "Panel Up" increases the panel back lighting intensity and pressing the bottom half of the switch, "Panel Down" decreases the panel back lighting intensity. Pressing the half or bottom half of the switch several times will allow back lighting intensity to be gradually varied from minimum to maximum intensity level for ease of use. Ignition switch: A three (3)-position maintained/momentary rocker switch will be provided. The first switch position will turn off and deactivate vehicle ignition. The second switch position will activate vehicle ignition and will perform prove-out on the telltale indicators and alarms for 3 to 5 seconds after the switch is turned on. A green indicator lamp is activated with vehicle ignition. The third momentary position will temporarily silence all active cab alarms. An alarm "chirp" may continue as long as alarm condition exists. Switching ignition to off position will terminate the alarm silence feature and reset function of cab alarm system. Engine start switch: A two (2)-position momentary rocker switch will be provided. The first switch position is the default switch position. The second switch position will activate the vehicle's engine. The switch actuator is designed to prevent accidental activation. Hazard switch will be provided on the instrument panel or on the steering column. Heater, defrost, and air conditioning control panel. Turn signal arm: A self-canceling turn signal with high beam headlight controls. Windshield wiper control will have high, low, and intermittent modes. Parking brake control: An air actuated push/pull park brake control. Chassis horn control: Activation of the chassis horn control will be provided through the center of the steering wheel. High idle engagement switch: A maintained rocker switch with integral indicator lamp will be provided. The switch will activate and deactivate the high idle function. The "OK To Engage High Idle" indicator lamp must be active for the high idle function to engage. A green indicator lamp integral to the high idle engagement switch will indicate when the high idle function is engaged. Port Arthur Stock Saber Pumper "OK To Engage High Idle" indicator lamp: A green indicator light will be provided next to the high idle activation switch to indicate that the interlocks have been met to allow high idle engagement. Custom Switch Panels The design of cab instrumentation will allow for emergency lighting and other switches to be placed within easy reach of the operator thus improving safety. There will be positions for up to four (4) switch panels in the lower instrument console and up to six (6) switch panels in the overhead visor console. All switches have backlit labels for low light conditions. n • 11 41. • 011110 011111) Diagnostic Panel A diagnostic panel will be provided and accessible while standing on the ground. The panel will be located inside the driver's side door left of the steering column. The diagnostic panel will allow diagnostic tools such as computers to connect to various vehicle systems for improved troubleshooting providing a lower cost of ownership. Diagnostic switches will allow ABS systems to provide blink codes should a problem exist. The diagnostic panel will include the following: • ENGINE/TRANSMISSION/ABS J1939 Diagnostic Port Port Arthur Stock Saber Pumper • ABS Diagnostic Switch and Indicator- The switch and amber indicator will allow access to diagnostic mode and display of standard ABS system fault blink codes that may be generated by the ABS system • DPF REGEN (Diesel Particulate Filter Regeneration Switch) (where applicable) will be provided to request regeneration of the engine emission system. An amber indicator will be provided on top of the switch that will illuminate in a "CHECK ENGINE" condition • REGEN INHIBIT (Diesel Particulate Filter Regeneration Inhibit Switch) (where applicable) will be provided that will request that regeneration be temporarily prevented. A green indicator will be provided on top of the Regen Inhibit switch that will illuminate when the Regen Inhibit feature is active. Regen Inhibit will be disabled upon cycling of the ignition switch to the off state. AIR RESTRICTION INDICATOR A high air restriction warning indicator light (electronic)will be provided. "DO NOT MOVE APPARATUS" INDICATOR A flashing red indicator light, located in the driving compartment, will be illuminated automatically per the current NFPA requirements. The light will be labeled "Do Not Move Apparatus If Light Is On." The same circuit that activates the Do Not Move Apparatus indicator will activate a pulsing alarm when the parking brake is released. SWITCH PANELS The built-in switch panels will be located in the lower console or overhead console of the cab. Switches will be rocker type with an indicator light, of which is an integral part of the switch. WIPER CONTROL Wiper control will consist of a two (2)-speed windshield wiper control with intermittent feature and windshield washer controls. The control will be located on the left side of the center instrument panel. CAB USB There will be four (4) USB terminations with a combination USB type A & C wired to battery direct power and provided per the following: • One (1) within reach of the driver • One (1)within reach of the passenger • Two (2) on the rear of the engine tunnel, one (1) each side. Battery direct loads cannot be load managed. SPARE CIRCUIT There will be one (1) pair of wires, including a positive and a negative, installed on the apparatus. The wires will have the following features: • The positive wire will be connected directly to the battery power. • The negative wire will be connected to ground. • Wires will be capable of carrying 15 amps. Port Arthur Stock Saber Pumper • Power and ground will terminate behind officer seat. • Termination will be with a 10-place bus bar with screws and removable cover. • Wires will be protected to meet the NFPA Automotive Fire Apparatus standard. Battery direct loads cannot be Load Managed. INFORMATION CENTER There will be a LCD display integral to the cab gauge panel provided that will display the following information: • Total distance • Trip distance • Total hours • Trip hours • PTO "A" hours • PTO "B" hours COLLISION MITIGATION There will be a HAAS Alert®, Model HA7 Responder-to-Vehicle (R2V) collision avoidance system provided on the apparatus. The HA7 cellular transponder module will be installed behind the cab windshield, as high and near to the center as practical, to allow clear visibility to the sky. The module dimensions are 5.40" long x 2.70" wide x 1.30" high, and operating temperature range is-40 degrees Celsius to 85 degrees Celsius. The transponder will be connected to the vehicle's emergency master circuit and battery direct power and ground. While responding with emergency lights on, the HA7 transponder sends alert messages via cellular network to motorists in the vicinity of the responding truck that are equipped with the WAZE app. While on scene with emergency lights on, the HA7 transponder sends road hazard alerts to motorists in the vicinity of the truck that are equipped with the WAZE app. The HA7 Responder-to-Vehicle (R2V) collision avoidance system will include the transponder and a 5 year cellular plan subscription. Activation of the HAAS Alert system requires a representative of the customer to accept the End User License Agreement (EULA) via an on-line portal. VEHICLE DATA RECORDER There will be a vehicle data recorder (VDR) capable of reading and storing vehicle information provided. The information stored on the VDR can be downloaded through a USB port mounted in a convenient location determined by cab model. A USB cable can be used to connect the VDR to a laptop to retrieve required information. The program to download the information from the VDR will be available to download on-line. Port Arthur Stock Saber Pumper The vehicle data recorder will be capable of recording the following data via hardwired and/or CAN inputs: • Vehicle Speed - MPH • Acceleration - MPH/sec • Deceleration - MPH/sec • Engine Speed - RPM • Engine Throttle Position - % of Full Throttle • ABS Event- On/Off • Seat Occupied Status -Yes/No by Position • Seat Belt Buckled Status -Yes/No by Position • Master Optical Warning Device Switch - On/Off • Internal clock syncs the time and date when a laptop is connected Seat Belt Monitoring System A seat belt monitoring system (SBMS)will be provided. The SBMS will be capable of monitoring up to 10 seating positions indicating the status of each seat position per the following: • Seat Occupied & Buckled = Green LED indicator illuminated • Seat Occupied & Unbuckled = Red LED indicator with audible alarm • No Occupant & Buckled = Red LED indicator with audible alarm • No Occupant & Unbuckled = No indicator and no alarm • FAULT = Blue LED indicator illuminated The SBMS will include an audible alarm that will warn that an unbuckled occupant condition exists and the parking brake is released, or the transmission is not in park. VEHICLE CAMERA SYSTEM There will be a color vehicle camera system provided with the following: • One (1) Analog High Definition (AHD) black camera located at the rear of the apparatus, pointing rearward, displayed automatically with the vehicle in reverse. The camera image will be displayed on a 7.00" High Definition (HD) display located in view of the driver on the dash. The display will include manual camera activation capability and audio from the active camera. The following components will be included: • One (1) HD700136DC, display • One (1) 1080p AHD rear camera • All necessary cables Camera Switcher A camera switcher is not required. Port Arthur Stock Saber Pumper ELECTRICAL POWER CONTROL SYSTEM A compartment will be provided in or under the cab to house the vehicle's electrical power and signal circuit protection and control components. The power and signal protection and control compartment will contain circuit protection devices and power control devices. Power and signal protection and control components will be protected against corrosion, excessive heat, excessive vibration, physical damage and water spray. Serviceable components will be readily accessible. Circuit protection devices, which conform to SAE standard, will be utilized to protect each circuit. All circuit protection devices will be sized to prevent wire and component damage when subjected to extreme current overload. General protection circuit breakers will be Type-I automatic reset (continuously resetting) and conform to SAE J553 or J258. When required, automotive type fuses conforming to SAE J554, J1284, J1888 or J2077 will be utilized to protect electronic equipment. Power control relays and solenoids will have a direct current (dc) rating of 125 percent of the maximum current for which the circuit is protected. Visual status indicators will be supplied to identify control safety interlocks and vehicle status. In addition to visual status indicators, audible alarms designed to provide early warning of problems before they become critical will be used. Voltage Monitor System A voltage monitor system will be provided to indicate the status of each battery system connected to the vehicle's electrical load. The monitor system will provide visual and audio warning when the system voltage is below optimum levels. Power and Ground Studs Spare circuits will be provided in the primary distribution center for two-way radio equipment. The spare circuits will consist of the following: • One (1) 12-volt DC, 30 amp battery direct spare • One (1) 12-volt DC ground and un-fused switched battery stud located in or adjacent to the power distribution center EMI/RFI Protection The electrical system proposed will include means to control undesired electromagnetic and radio frequency emissions. State of the art electrical system design and components will be used to ensure radiated and conducted EMI (electromagnetic interference) and RFI (radio frequency interference) emissions are suppressed at their source. The apparatus proposed will have the ability to operate in the electromagnetic environment typically found in fire ground operations. The contractor will be able to demonstrate the EMI and RFI testing has been done on similar apparatus and certifies that the vehicle proposed meets SAE J551 requirements. EMI/RFI susceptibility will be controlled by applying immune circuit designs, shielding, twisted pair wiring and filtering. The electrical system will be designed for full compatibility with low level control Port Arthur Stock Saber Pumper signals and high powered two-way radio communication systems. Harness and cable routing will be given careful attention to minimize the potential for conducting and radiated EMI-RFI susceptibility. ELECTRICAL All 12-volt electrical equipment installed by Pierce Manufacturing will conform to modern automotive practices. All wiring will be high temperature crosslink type. Wiring will be run, in loom or conduit, where exposed and have grommets where wire passes through sheet metal. Automatic reset circuit breakers will be provided which conform to SAE Standards. Wiring will be color, function and number coded. Function and number codes will be continuously imprinted on all wiring harness conductors at 2.00" intervals. Exterior exposed wire connectors will be positive locking, and environmentally sealed to withstand elements such as temperature extremes, moisture and automotive fluids. Electrical wiring and equipment will be installed utilizing the following guidelines: 1. All holes made in the roof will be caulked with silicon. Large fender washers, liberally caulked, will be used when fastening equipment to the underside of the cab roof. 2. Any electrical component that is installed in an exposed area will be mounted in a manner that will not allow moisture to accumulate in it. Exposed area will be defined as any location outside of the cab or body. 3. Electrical components designed to be removed for maintenance will not be fastened with nuts and bolts. Metal screws will be used in mounting these devices. Also, a coil of wire will be provided behind the appliance to allow them to be pulled away from mounting area for inspection and service work. 4. Corrosion preventative compound will be applied to all terminal plugs located outside of the cab or body. All non-waterproof connections will have this compound in the plug to prevent corrosion and for easy separation (of the plug). 5. All lights that have their sockets in a weather exposed area will have corrosion preventative compound added to the socket terminal area. 6. All electrical terminals in exposed areas will have silicon applied completely over the metal portion of the terminal. All lights and reflectors, required to comply with Federal Motor Vehicle Safety Standard #108, will be furnished. Rear identification lights will be recessed mounted for protection. Lights and wiring mounted in the rear bulkheads will be protected from damage by installing a false bulkhead inside the rear compartments. An operational test will be conducted to ensure that any equipment that is permanently attached to the electrical system is properly connected and in working order. The results of the tests will be recorded and provided to the purchaser at time of delivery. BATTERY SYSTEM There will be four(4) 12 volt Stryten/Exide®, Model 31 S950X5W, batteries that include the following features will be provided: • 950 CCA, cold cranking amps Port Arthur Stock Saber Pumper • 190 amp reserve capacity • High cycle • Group 31 • Rating of 3800 CCA at 0 degrees Fahrenheit • 760 minutes of reserve capacity • Threaded stainless steel studs Each battery case will be a black polypropylene material with a vertically ribbed container for increased vibration resistance. The cover will be manifold vented with a central venting location to allow a 45 degree tilt capacity. The inside of each battery will consist of a "maintenance free" grid construction with poly wrapped separators and a flooded epoxy bottom anchoring for maximum vibration resistance. BATTERY SYSTEM There will be a single starting system with an ignition switch and starter button provided and located on the cab instrument panel. MASTER BATTERY SWITCH There will be a master battery switch provided within the cab within easy reach of the driver to activate the battery system. An indicator light will be provided on the instrument panel to notify the driver of the status of the battery system. BATTERY COMPARTMENTS Batteries will be placed on non-corrosive mats and be stored in well ventilated compartments located under the cab and bolted directly to the chassis frame. The battery boxes will have reinforced sides. The battery compartments will be constructed of 0.188" steel plate and be designed to accommodate a maximum of three (3) group 31 batteries in each compartment. The battery hold-downs will be of a non-corrosive material. All bolts and nuts will be stainless steel. Heavy-duty, 2/0 gauge, color coded battery cables will be provided. Battery terminal connections will be coated with anti-corrosion compound. Battery solenoid terminal connections will be encapsulated with semi-permanent rubberized compound. JUMPER STUDS One (1) set of battery jumper studs with plastic color-coded covers will be included on the battery compartments. BATTERY CHARGER There will be a KussmaulTM, Chief Series Smart Charger 6012, product code 091-266-12-60, 60 amp battery charger with build-in touch screen display provided. The battery charger will be wired to the AC [AC Power Source] through a junction box located near the battery charger. Port Arthur Stock Saber Pumper The battery charger will be located in the cab behind the driver seat. REMOTE CONTROL PANEL - BATTERY CHARGER There will be a KussmaulTM, Model 091-94-12 universal display panel included. It will be wired directly to the chassis batteries. The battery charger indicator will be located on the driver's seat riser. AUTO EJECT FOR SHORELINE There will be one (1) KussmaulTM, Model 091-55-20-120, 20 amp 120 volt AC shoreline inlet(s) provided to operate the dedicated 120 volt AC circuits on the apparatus. The shoreline inlet(s) will include red weatherproof flip up cover(s). There will be a release solenoid wired to the vehicle's starter to eject the AC connector when the engine is starting. The shoreline(s)will be connected to Battery Charger and 120V cab & body receptacles. There will be a mating connector body supplied with the loose equipment. There will be a label installed near the inlet(s) that state the following: • Line Voltage • Current Ratting (amps) • Phase • Frequency The shoreline receptacle will be located on the driver side of cab, to the front of cab door. ALTERNATOR A Delco Remy®, Model 40SI, alternator will be provided. It will have a rated output current of 320 amps, as measured by SAE method J56. The alternator will feature an integral regulator and rectifier system that has been tested and qualified to an ambient temperature of 257 degrees Fahrenheit (125 degrees Celsius). The alternator will be connected to the power and ground distribution system with heavy-duty cables sized to carry the full rated alternator output. ELECTRONIC LOAD MANAGEMENT An electronic load management (ELM) system that monitors the vehicles 12-volt electrical system, and automatically reduces the electrical load in the event of a low voltage condition and by doing so, ensures the integrity of the electrical system. The ELM will monitor the vehicle's voltage while at the scene (parking brake applied). It will sequentially shut down individual electrical loads when the system voltage drops below a preset value. Two (2) separate electrical loads will be controlled by the load manager. The ELM will sequentially re- energize electrical loads as the system voltage recovers. Port Arthur Stock Saber Pumper HEADLIGHTS There will be four (4) JW Speaker®, Model EVO-X, 4" x 6" rectangular LED lights mounted in the front quad style, chrome housing on each side of the cab grille: • the outside light on each side will contain a part number 056***1 low beam module • the inside light on each side will contain a part number 056***1 high beam module • the headlights to include chrome bezels The low beam lights will be activated when the headlight switch is on. The high beam and low beam lights will be activated when the headlight switch and the high beam switch is activated. FRONT DIRECTIONALS The front directional's will be Whelen®, Model M62T, 4.31" high x 6.75" wide x 1.37" deep directional lights with amber LEDs. The lens color(s) to be clear. The directional's will be housed in the same common bezel as the front warning light and will be located above the headlights. The housing to be polished and the trim shall be chrome. The flash pattern of the directional lights will be Steady On (Arrow). INTERMEDIATE LIGHT There will be two (2)Weldon, Model 9186-8580-29, amber LED turn signal marker lights furnished, one (1) each side, in the rear fender panel. The light will double as a turn signal and marker light. CAB CLEARANCE/MARKER/ID LIGHTS There will be seven (7) amber LED lights provided per the following: • Three (3) amber LED identification lights will be installed in the center of the cab above the windshield. • Two (2) amber LED clearance lights will be installed, one (1) on each outboard side of the cab above the windshield as close to the outside of the apparatus as practical. • Two (2) amber LED clearance lights will be installed, one (1) on each side of the cab as high and far forward as practical. The lights will be installed without guards. FRONT CAB SIDE DIRECTIONAL/MARKER LIGHTS There will be two (2) Weldon, Model 9186-8580-29, amber LED lights installed front of the cab door, one (1) on each side of the cab. The lights will activate as marker lights with the headlight switch and directional lights with the corresponding directional circuit. REAR CLEARANCE/MARKER/ID LIGHTING There will be a three (3) LED light bar used as identification lights located at the rear of the apparatus per the following: Port Arthur Stock Saber Pumper • As close as practical to the vertical centerline • Centers spaced not less than 6.00" or more than 12.00" apart • Red in color • All at the same height There will be two (2) LED lights installed at the rear of the apparatus used as clearance lights located at the rear of the apparatus per the following: • To indicate the overall width of the vehicle • One (1) each side of the vertical centerline • As near the top as practical • Red in color • To be visible from the rear • All at the same height There will be two (2) LED lights installed on the side of the apparatus used as marker lights as close to the rear as practical per the following: • To indicate the overall length of the vehicle • One (1) each side of the vertical centerline • As near the top as practical • Red in color • To be visible from the side • All at the same height There will be two (2) red reflectors located on the rear of the truck facing to the rear. One (1) each side, as far to the outside as practical, at a minimum of 15.00", but no more than 60.00", above the ground. There will be two (2) red reflectors located on the side of the truck facing to the side. One (1) each side, as far to the rear as practical, at a minimum of 15.00", but no more than 60.00", above the ground. Per FMVSS 108 and CMVSS 108 requirements. REAR FMVSS LIGHTING The rear stop/tail and directional lighting included in the rear tail light housing will include the following: • Two (2) Whelen®, Model M62BTT, 4.30" high x 6.70" wide x 1.40" deep brake/tail lights with red LEDs • Two (2) Whelen, Model M62T, 4.30" high x 6.70" wide x 1.40" deep directional lights with amber LEDs. The directional lights will be set to Steady On (Arrow)flash pattern. • The lens color(s) to be clear. There will be two (2) Whelen Model M62BU, LED backup lights provided in the tail light housing. LICENSE PLATE BRACKET One (1) license plate bracket constructed of stainless steel will be provided at the rear of the apparatus. Port Arthur Stock Saber Pumper One (1)white LED light with chrome housing will be provided to illuminate the license plate. A stainless steel light shield will be provided over the light that will direct illumination downward, preventing white light to the rear. LIGHTING BEZEL There will be two (2) Whelen, Model M6FCV4P, four(4) place chromed ABS housings with Pierce logos provided for the rear M6 series stop/tail, directional, back up, scene lights or warning lights. BACK-UP ALARM A PRECO, Model 1040, solid-state electronic audible back-up alarm that actuates when the truck is shifted into reverse will be provided. The device will sound at 60 pulses per minute and automatically adjust its volume to maintain a minimum ten (10) dBA above surrounding environmental noise levels. CAB PERIMETER SCENE LIGHTS There will be four (4)Amdor, Model AY-LB-12HW0**, white LED strip lights provided, one (1) for each cab door that will meet NFPA ground lighting requirements. These lights will be activated automatically when the battery switch is on and the exit doors are opened or by the same means as the body perimeter scene lights. PUMP HOUSE PERIMETER LIGHTS There will be two (2) Amdor, Model AY-LB-12HW020, 350 lumens each, 20.00" LED weatherproof strip lights with brackets provided under the pump panel running boards, one (1) each side. If the combination of options in the vehicle does not permit clearance for a 20.00" light, a 12.00" version of the Amdor light will be installed. The lights will be controlled by the same means as the body perimeter lights. BODY PERIMETER SCENE LIGHTS There will be two (2) Amdor, Model AY-LB-12HW020, 350 lumens, 20.00" long, white LED's, 12 volt DC lights provided at the rear step area of the body, one (1) each side shining to the rear. The perimeter scene lights will be activated when the parking brake is applied. STEP LIGHTS There will be four (4)white LED, step lights provided. One (1) step light will be provided on each side, on the front compartment face and two (2) step lights at the rear to illuminate the tailboard. These step lights will be actuated when the ignition switch is on and the parking brake is set. All steps on the apparatus will be illuminated per the current edition of applicable NFPA standards. 12 VOLT LIGHTING There will be one (1) HiViz Model FT-B-46-*-*, 2.56" high x 46.00" long x 2.45" deep 13,306 effective lumens 12 volt DC light with white LEDs provided as far forward as possible on the front cab roof centered. The LEDs will be configured with a combination of flood and spot optics. The painted parts of the light housing and brackets to be black. Port Arthur Stock Saber Pumper The scene LEDs will be activated by a switch at the driver's side switch panel and by a switch at the passenger's side switch panel. The white LEDs may be load managed when the parking brake is applied. 12 VOLT DC SCENE LIGHTS There will be one (1) Whelen® Model PCPSM2*, 16,000 lumens 12 volt DC powered light(s)with white LEDs installed on the cab located, behind driver door, above side crew cab window, upper portion of cab. The surface mount housing(s)will be provided with a chrome cover. The light(s)will be activated by a switch at the driver's side switch panel and by a switch at the left side pump panel. The light(s) may be load managed when the parking brake is applied. 12 VOLT DC SCENE LIGHTS There will be one (1)Whelen® Model PCPSM2*, 16,000 lumens 12 volt DC powered light(s)with white LEDs installed on the cab located, behind officers door, above side crew cab window, upper portion of cab. The surface mount housing(s)will be provided with a chrome cover. The light(s) will be activated by a switch at the driver's side switch panel and by a switch at the left side pump panel. The light(s) may be load managed when the parking brake is applied. 12 VOLT LIGHTING There will be one (1)Whelen® Model PCPSM2*, 16,000 lumens 12 volt DC surface mount light(s) installed on the body of the apparatus located, on side sheet above LS1 in painted housing. The light(s)will include housing(s)with a chrome cover. The light(s)will be controlled by the same control that has been selected for the driver's side scene light(s). The light(s) may be load managed when the parking brake is applied. 12 VOLT LIGHTING There will be one (1)Whelen® Model PCPSM2*, 16,000 lumens 12 volt DC surface mount light(s) installed on the body of the apparatus located, on side sheet above RS1 in painted housing. The light(s)will include housing(s) with a chrome cover. The light(s)will be controlled by the same control that has been selected for the passenger's side scene light(s). Port Arthur Stock Saber Pumper The light(s) may be load managed when the parking brake is applied. HOSE BED LIGHTS There will be white 12 volt DC LED light strips with stainless steel protective cover, provided to light the hose bed area. Hose Bed lights will meet the photometric levels listed in the current edition of applicable NFPA standards for Hose Bed lighting requirements. • Light strip(s)will be installed along the upper edge of the left side of the hose bed. • Light strip(s)will be installed along the upper edge of the right side of the hose bed. The lights will be activated by a cup switch at the rear of the apparatus no more than 72.00"from the ground. REAR SCENE LIGHTS There will be two (2) Whelen® Model PEL2*, 12 volt DC white LED scene lights with chrome trim installed at the rear of the apparatus, rear of truck, mid-height, one each side. The lights will be controlled by a switch at the driver's side switch panel and by a cup switch at the driver's side rear bulkhead. WALKING SURFACE LIGHT There will be Model FRP, 4.00" round black 12 volt DC LED floodlight(s)with bolt mount provided to illuminate the entire designated walking surface on top of the body. The light(s) will be activated when the body step lights are on. WATER TANK Booster tank will have a capacity of 750 gallons and be constructed of polypropylene plastic by United Plastic Fabricating, Incorporated. Tank joints and seams will be nitrogen welded inside and out. Tank will be baffled in accordance with the current edition of applicable NFPA standards. Baffles will have vent openings at both the top and bottom to permit movement of air and water between compartments. Longitudinal partitions will be constructed of 0.38" polypropylene plastic and will extend from the bottom of the tank through the top cover to allow for positive welding. Transverse partitions will extend from 4.00" off the bottom of the tank to the underside of the top cover. All partitions will interlock and will be welded to the tank bottom and sides. Tank top will be constructed of 0.50" polypropylene. It will be recessed 0.38" and will be welded to the tank sides and the longitudinal partitions. Tank top will be sufficiently supported to keep it rigid during fast filling conditions. Port Arthur Stock Saber Pumper Construction will include 2.00" polypropylene dowels spaced no more than 30.00" apart and welded to the transverse partitions. Two (2) of the dowels will be drilled and tapped (0.50" diameter, 13.00" deep) to accommodate lifting eyes. A sump that will be sized dependent on the tank to pump plumbing will be provided at the bottom of the water tank. Sump will include a drain plug and the tank outlet. Tank will be installed in a fabricated cradle assembly constructed of structural steel. Sufficient crossmembers will be provided to properly support bottom of tank. Crossmembers will be constructed of steel bar channel or rectangular tubing. Tank will "float" in cradle to avoid torsional stress caused by chassis frame flexing. Rubber cushions, .50" thick x 3.00" wide, will be placed on all horizontal surfaces that the tank rests on. Stops or other provision will be provided to prevent an empty tank from bouncing excessively while moving vehicle. Mounting system will be approved by the tank manufacturer. Fill tower will be constructed of 0.50" polypropylene and will be a minimum of 8.00" wide x 14.00" long. Fill tower will be furnished with a 0.25" thick polypropylene screen and a hinged cover. An overflow pipe, constructed of 4.00" schedule 40 polypropylene, will be installed approximately halfway down the fill tower and extend through the water tank and exit to the rear of the rear axle. SLEEVE PLUMBING THROUGH TANK Two (2) sleeves will be provided in the water tank for a 3.00" pipe to the rear. WATER TANK RESTRAINT A heavy-duty water tank restraint will be provided. HOSE BED The hose bed will be fabricated of 0.125"-5052 aluminum with a nominal 38,000 psi tensile strength. The hose bed will be as low as practical. Upper and rear edges of side panels will have a double break for rigidity. The upper area at the rear of the hose bed will be covered with brushed stainless steel to prevent damage to painted surface when hose is removed. Flooring of the hose bed will be removable aluminum grating with the top surface corrugated to aid in hose aeration. The grating slats will be a minimum of 0.50" x 4.50" with spacing between slats for hose ventilation. Port Arthur Stock Saber Pumper A cross divider will be provided at the front of the hose bed before the tank transitions from the lower section to the upper section. The divider will run from the top of the side sheet down below the hose bed grating. The inside of the hose bed will be painted. The inside of the cargo area above the pump will be painted. Hose bed will accommodate 250 2.5 250 2.5 800 3" 1200 4" 400 1.75 Left to right. HOSE BED DIVIDER Four (4) hosebed dividers will be furnished for separating hose. Each divider will be constructed of a 0.25" brushed aluminum sheet. Flat surfaces will be sanded for uniform appearance or constructed of brushed aluminum. Divider will be fully adjustable by sliding in tracks, located at the front and rear of the hose bed. Divider will be held in place by tightening bolts, at each end. Acorn nuts will be installed on all bolts in the hose bed which have exposed threads. HOSE BED DEFLECTOR A hose bed wind deflector will be provided at the front of the hose bed. The cover will be 30.00" long x full width of the hose bed. The cover will be constructed of .19" bright aluminum treadplate, hinged to the hose bed cross divider with a full length stainless steel piano hinge and resting on the hose bed dividers and side sheets. The cover will have a 1.00" upward "Lazy Bend" at the rear with additional bracing underneath for stiffening. A chrome grab handle will be provided in the rear center of the cover to assist in opening and closing. Pneumatic cylinders will be provided to hold the deflector in the open position. The cover will be labeled "NO STEP" using 3.00" lettering. Swell latches will be provided at the outboard rearward corners. A single pair of black nylon Velcro® straps will be provided towards the rear at the top of the hose bed to retain hose within the hose bed. A heavy duty 2" black nylon webbing will be installed at the rear of the hose bed and wrap over the top of the hose bed with seat belt buckles at the top. The seat belt buckles will be provided with a metal bar, to connect the buckles, and an attached web strap, to allow a single pull release. At the bottom of the webbing, hinged style seat belt buckle will be provided. If a strap is provided, the color of the strap will be black. RUNNING BOARDS Running boards will be fabricated of 0.125" bright aluminum treadplate. Port Arthur Stock Saber Pumper Each running board will be supported by a welded 2.00" square tubing and channel assembly, which will be bolted to the pump compartment substructure. Running boards will be 12.75" deep and spaced 0.50" away from the pump panel. A splash guard will be provided above the running board treadplate. TAILBOARD The tailboard will also be constructed of .125" bright aluminum treadplate and spaced .50" from the body, as well as supported by a structural steel assembly. The tailboard area will be 12.00" deep and full width of the body. The outboard sides of the tailboar d will be angled at 45 degrees beginning at the point where the body meets the tailboard at the outboard edge angling rearward to the rear edge of the tailboard. The exterior side will be flanged down and in for increased rigidity of tailboard structure. REAR WALL, SMOOTH ALUMINUM/BODY MATERIAL The rear wall body material will be painted. Unpainted aluminum overlays will be provided to allow for chevron application and to provide continuously smooth rear wall panels. The rear wall will be flush. REAR TOW EYES Two (2)tow eyes, which are an integral part of the body mounting substructure, will be installed below the rear of the truck. The tow eyes will be of adequate strength to allow the truck to be pulled from the eyes. REAR TOW BAR One (1)tow bar will be installed under the tailboard. The tow bar assembly will be designed and positioned to allow up to a 30-degree upward angled pull of 17,000 Ib, or a 20,000 lb straight horizontal pull in line with the centerline of the vehicle. The tow bar design will have been tested and evaluated using finite element analysis techniques. RUNNING BOARD HOSE RESTRAINT A pair of 2.00"wide black nylon straps with Velcro fasteners will be provided for each hose tray to secure the hose during travel. Two (2) hose trays will be located one (1) in each side running board. HOSE TRAY Two (2) hose trays will be made free floating one (1) in each side running board. The tray(s) will be flanged and drop in from the top. The front and rear corners at the base of tray will be tapered. No fasteners will be used to secure the tray(s). I Capacity of the tray will be 90' of 1.5". Port Arthur Stock Saber Pumper Rubber matting will be installed on the floor of the tray to provide proper ventilation. Drain holes will be provided. COMPARTMENTATION Body and compartments will be fabricated of 0.125", 5052-H32 aluminum. Side compartments will be an integral assembly with the rear fenders. Circular fender liners will be provided for prevention of rust pockets and ease of maintenance. Side compartment flooring will be of the sweep out design with the floor higher than the compartment door lip. The side compartment door opening will be framed by flanging the edges in 1.75" and bending out again 0.75" to form an angle. Drip protection will be provided above the doors by means of bright aluminum extrusion, formed bright aluminum treadplate or polished stainless steel. The top of the compartment will be covered with bright aluminum treadplate rolled over the edges on the front, rear and outward side. These covers will have the corners welded. Side compartment covers will be separate from the compartment tops. Front facing compartment walls will be covered with bright aluminum treadplate. All screws and bolts which protrude into a compartment will have acorn nuts on the ends to prevent injury. UNDERBODY SUPPORT SYSTEM Due to the severe loading requirements of this pumper a method of body and compartment support suitable for the intended load will be provided. The backbone of the support system will be the chassis frame rails which is the strongest component of the chassis and is designed for sustaining maximum loads. Forward to the rear axle, the support system will include "L"-shaped support members bolted to the chassis frame rails. These welded support members will include vertical formed channels, horizontal structural channels, and support gussets. These parts extend from the chassis frame outward underneath the body. Rearward to the rear axle, the body support system will include two rearward facing "L"-shaped support members bolted to the chassis frame rails. These support members will be connected to the two body supporting crossmembers forming a boxed foundation for the rear body support system. Steel upper platform decks will be mounted on the top of these support members to create a floating substructure which will result in a 500 lb equipment support rating per lower compartment. Port Arthur Stock Saber Pumper All structural components of this system will be made from high strength 50K steel plate material or structural steel componentry. The steel frames as well as the steel vertical angles will be treated with an epoxy E-coat or equivalent to provide resistance to corrosion and chemicals as standard. The floating substructure will be separated from the horizontal members with neoprene elastomer isolators. These isolators will reduce the natural flex stress of the chassis from being transmitted to the body. Isolators will have a broad load range, proven viability in vehicular applications, be of a fail-safe design and allow for all necessary movement in three (3) transitional and rotational modes. The neoprene isolators will be installed in a pattern which assimilates a three (3)-point mounting pattern to reduce the natural flex of the chassis being transmitted to the body. A design with body compartments hanging on the chassis in an unsupported fashion will not be acceptable. AGGRESSIVE WALKING SURFACE All exterior surfaces designated as stepping, standing, and walking areas will comply with the required average slip resistance of the current NFPA standards. LOUVERS Louvers will be stamped into compartment walls to provide the proper airflow inside the body compartments and to prevent water from dripping into the compartment. Where these louvers are provided, they will be formed into the metal and not added to the compartment as a separate plate. TESTING OF BODY DESIGN Body structural analysis will be fully tested. Proven engineering and test techniques such as finite element analysis, strain gauging, and model analysis will be performed with special attention given to fatigue, life and structural integrity of the body and substructure. Body will be tested while loaded to its greatest in-service weight. The criteria used during the testing procedure will include: • Raising opposite corners of the vehicle tires 9.00" to simulate the twisting a truck may experience when driving over a curb. • Making a 90 degree turn, while driving at 20 mph to simulate aggressive driving conditions. • Driving the vehicle at 35 mph on a washboard road. • Driving the vehicle at 55 mph on a smooth road. • Accelerating the vehicle fully, until reaching the approximate speed of 45 mph on rough pavement. Evidence of actual testing techniques will be made available upon request. LEFT SIDE COMPARTMENTATION The left side compartmentation will consist of three (3) rollup door compartments. Port Arthur Stock Saber Pumper A full height, rollup door compartment ahead of the rear wheels will be provided. The interior dimensions of this compartment will be 27.50" wide x 66.63" high x 25.88" deep in the lower 25.00" of the compartment and 12.00" deep in the remaining upper portion. The clear door opening will be a minimum of 21.75"wide x 56.88" high. A rollup door compartment over the rear wheels will be provided. The interior dimensions of this compartment will be 66.50" wide x 32.88" high x 12.00" deep. The clear door opening will be a minimum of 58.25"wide x 23.13" high. A full height, rollup door compartment behind the rear wheels will be provided. The interior dimensions of this compartment will be 47.75" wide x 67.63" high x 25.88" deep in the lower 26.00" of height and 12.00" deep in the remaining upper section of the compartment. The clear door opening will be a minimum of 44.75" wide x 57.88" high. —FRONT it 'Ilia i j ji I'' ._I ,IR FI 4 72.00 7 25.00 26.00 145.00 CLEAR DOOR OPENINGS AMDOR GORTITE ROM COMPARTMENT HORIZONTAL VERTICAL HORIZONTAL VERTICAL HORIZONTAL VERTICAL Ahead of axle 22.50 56.88 21.75 58.00 21.94 58.25 Over axle 59.00 23.13 58.25 24.25 58.44 24.50 Behind axle 45.50 57.88 44.75 59.00 44.94 59.25 The interior height of the compartments will be measured from the compartment floor to the ceiling. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartments will be measured from the back wall to the inside of the door frame. Closing of the doors will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand. RIGHT SIDE COMPARTMENTATION The right side compartmentation will consist of two (2) rollup door compartments. A rollup door compartment ahead of the rear wheels will be provided. The interior dimensions of this compartment will be 27.50" wide x 32.63" high x 25.88" deep in the lower 25.00" of the compartment and 12.00" deep in the remaining upper portion. The clear door opening will be a minimum of 21.75" wide x 22.88" high. Port Arthur Stock Saber Pumper A rollup door compartment behind the rear wheels will be provided. The interior dimensions of this compartment will be 47.75" wide x 33.63" high x 25.88" deep in the lower 26.00" of height and 12.00" deep in the remaining upper section of the compartment. The clear door opening will be a minimum of 44.75" wide x 23.88" high. _ 36.00 1 I45.00 —� CLEAR DOOR OPENINGS AMOOR GORTITE ROM COMPARTMENT HORIZONTAL VERTICAL HORIZONTAL VERTICAL HORIZONTAL VERTICAL Ahead of axle 22.50 22.88 21.75 24.00 21.94 24.25 Behind axle 45.50 23.88 44.75 25.00 44.94 25.25 The interior height of the compartments will be measured from the compartment floor to the ceiling. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartments will be measured from the back wall to the inside of the door frame. Closing of the doors will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand. SIDE COMPARTMENT ROLLUP DOOR(S) There will be five (5) compartment doors installed on the side compartments, double faced, aluminum construction, painted one (1) color to match the lower portion of the body and manufactured by AMDORTM brand rollup doors. Door(s) will be constructed using 1.00" extruded double wall aluminum slats which will feature a flat smooth interior surface to provide maximum protection against equipment hang-up. The slats will be connected with a structural driven ball and socket hinge designed to provide maximum curtain diaphragm strength. Mounting and adjusting the curtain will be done with a clip system that connects the curtain to the balancer drum allowing for easy tension adjustment without tools. The slats will be mounted in reusable slat shoes with positive snap-lock securement. Each slat will incorporate weather tight recessed dual durometer seals. One (1)fin will be designed to locate the seal within the extrusion. The second will serve as a wiping seal which will also allow for compression to prevent water ingression. Port Arthur Stock Saber Pumper The doors will be mounted in a one (1)-piece aluminum side frame with recessed side seals to minimize seal damage during equipment deployment. All seals including side frames, top gutters and bottom panel are to be manufactured utilizing non-marring materials. Bottom panel flange of rollup door will be equipped with two (2) cut-outs to allow for easier access with gloved hands. A polished stainless steel lift bar to be provided for each roll-up door. The lift bar will be located at the bottom of door with striker latches installed at the base of the side frames. Side frame mounted door strikers will include support beneath the stainless steel lift bar to prevent door curtain bounce, improve bottom seal life expectancy and to avoid false door ajar signals. All injection molded rollup door wear components will be constructed of Type 6 nylon. Each rollup door will have a 3.00 inch diameter balancer/tensioner drum to assist in lifting the door. The header for the rollup door assembly will not exceed 4.00". A heavy-duty magnetic switch will be used for control of open compartment door warning lights. REAR COMPARTMENTATION A roll-up door compartment above the rear tailboard will be provided. The interior dimensions of this compartment will be 40.00" wide x 33.63" high x 25.88" deep. The clear door opening of this compartment will be a minimum of 33.25" wide x 23.88" high. The interior height of the compartments will be measured from the compartment floor to the ceiling. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartment will be calculated with the compartment door closed. A louvered, removable access panel will be furnished on the back wall of the compartment. The rear compartment will be open into the rear side compartments. Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand. ROLLUP REAR COMPARTMENT DOOR The rear compartment will have a rollup door. The door will be double faced, aluminum construction, satin aluminum and manufactured by AMDORTM brand rollup doors. The door will be constructed using 1.00" extruded double wall aluminum slats which will feature a flat smooth interior surface to provide maximum protection against equipment hang-up. The slats will be connected with a structural driven ball and socket hinge designed to provide maximum curtain diaphragm strength. Mounting and adjusting the curtain will be done with a clip system that connects the curtain to the balancer drum allowing for easy tension adjustment without tools. The slats will be mounted in reusable slat shoes with positive snap-lock securement. Port Arthur Stock Saber Pumper Each slat will incorporate weather tight recessed dual durometer seals. One (1)fin will be designed to locate the seal within the extrusion. The second will serve as a wiping seal which will also allow for compression to prevent water ingression. The door will be mounted in a one (1)-piece aluminum side frame with recessed side seals to minimize seal damage during equipment deployment. All seals including side frames, top gutters and bottom panel are to be manufactured utilizing non-marring materials. Bottom panel flange of rollup door will be equipped with two (2) cut-outs to allow for easier access with gloved hands. A polished stainless steel lift bar to be provided for each roll-up door. The lift bar will be located at the bottom of door with striker latches installed at the base of the side frames. Side frame mounted door strikers will include support beneath the stainless steel lift bar to prevent door curtain bounce, improve bottom seal life expectancy and to avoid false door ajar signals. All injection molded rollup door wear components will be constructed of Type 6 Nylon. The door will have a 3.00 inch diameter balancer/tensioner drum to assist in lifting the door. The header for the rollup door assembly will not exceed 4.00". A heavy-duty magnetic switch will be used for control of open compartment door warning lights. COMPARTMENT LIGHTING There will be six (6) compartments that include Amdor, Model AY-LB-12HW0**, white 12 volt DC LED compartment light strips with 45 degree brackets. The light manufacturers electrical connectors will be included in the circuit. The lights will be mounted with mechanical fasteners. There will be two (2) strip lights installed vertically in each compartment opening per the latest NFPA requirements. The lights will be activated when the battery switch is on and the respective compartment door is opened. MOUNTING TRACKS There will be six (6) sets of tracks for mounting shelf(s) in LS1, LS2, LS3, RS1, RS2 and B1. These tracks will be installed vertically to support the adjustable shelf(s). The tracks will be painted to match the compartment interior. ADJUSTABLE SHELVES There will be five (5) shelves with a capacity of 500 lb provided. The shelf construction will consist of .188" aluminum painted spatter gray with 2.00" sides. Each shelf will be infinitely adjustable by means of a threaded fastener, which slides in a track. The shelves will be held in place by .12"thick stamped plated brackets and bolts. Port Arthur Stock Saber Pumper The location(s)will be in LS1 at the depth transition point, in RS1 centered between the floor and the ceiling, in RS2 centered between the floor and the ceiling, in LS2 centered between the floor and ceiling and in LS3 at the depth transition point. SLIDE-OUT FLOOR MOUNTED TRAY There will be one (1)floor mounted slide-out tray(s) provided. Each tray will have 2.00" high sides and a minimum capacity rating of 500 lb in the extended position. Each tray will be constructed of aluminum painted spatter gray. There will be two undermount-roller bearing type slides rated at 250 lb each provided. The pair of slides will have a safety factor rating of 2. To ensure years of dependable service, the slides will be coated with a finish that is tested to withstand a minimum of 1,000 hours of salt spray per ASTM B117. To ensure years of easy operation, the slides will require no more than a 50Ib force for push-in or pull- out movement when fully loaded after having been subjected to a 40 hour vibration (shaker)test under full load. The vibration drive file will have been generated from accelerometer data collected from a heavy truck chassis driven over rough gravel roads in an unloaded condition. Proof of compliance will be provided upon request. Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand. The location(s)will be B1. RUB RAIL Bottom edge of the side compartments will be trimmed with a bright aluminum extruded rub rail. Trim will be 2.12" high with 1.38"flanges turned outward for rigidity. The rub rails will not be an integral part of the body construction, which allows replacement in the event of damage. BODY FENDER CROWNS Polished stainless steel fender crowns will be provided around the rear wheel openings with a dielectric barrier will be provided between the fender crown and the fender sheet metal to prevent corrosion. The fender crowns will be held in place with stainless steel screws that thread directly into a composite nut and not directly into the parent body sheet metal to eliminate dissimilar metals contact and greatly reduce the chance for corrosion. Rubber welting will be provided between the body and crown. BODY FENDER LINER A unpainted brushed stainless fender liner will be provided. The liners will be removable to aid in the maintenance of rear suspension components. Port Arthur Stock Saber Pumper HARD SUCTION HOSE Hard suction hose will not be required. HANDRAILS The handrails will be 1.25" diameter knurled aluminum to provide a positive gripping surface. Chrome plated end stanchions will support the handrail. Plastic gaskets will be used between end stanchions and any painted surfaces. Drain holes will be provided in the bottom of all vertically mounted handrails. Handrails will be provided to meet current edition of applicable NFPA standards. The handrails will be installed as noted on the sales drawing. HANDRAILS One (1) vertical handrail will be located on each rear beavertail. HANDRAIL One (1) horizontal knurled aluminum handrail will be provided above the hose bed at the rear of the apparatus. AIR BOTTLE STORAGE (DOUBLE) A quantity of four (4) air bottle compartments, 15.25" wide x 7.75"tall x 26.00" deep, will be provided on the left side rearward of the rear wheels, on the right side forward of the rear wheels, on the right side rearward of the rear wheels and on the left side forward of the rear wheels. An access panel through the floor of the compartment to be provided for access to the DEF tank header. A polished stainless steel door with a Southco raised trigger C2 chrome lever latch will be provided to contain the air bottle. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal. Inside the compartment, black rubber matting will be provided. EXTENSION LADDER There will be a 24'two-section aluminum Duo-Safety Series 900-A extension ladder provided. ROOF LADDER There will be a 14' aluminum Duo-Safety Series 775-A roof ladder provided. LADDER BRACKETS The ladders will be installed on the right side of the hose body in lined brackets and held in place by chrome plated, quarter-turn spring loaded clamps. The clamps will be such that when the roof ladder is removed, the clamps can be moved a half turn to hold the extension ladder in place. The ladder brackets will be adjustable up and down. FOLDING LADDER One (1) 10.00' aluminum, Series 585-A, Duo-Safety folding ladder will be provided. Port Arthur Stock Saber Pumper The mounting tube will be installed on the inside of the side sheet ladder mounting brackets. A stop will be provided to keep the ladder from sliding forward in the bracket. A nylon strap will be provided at the rear of the tube to retain the ladder. PIKE POLE PROVIDED BY FIRE DEPARTMENT The pike poles are not on the apparatus as manufactured. The fire department will provide and mount the pike poles. There will be one (1) pike pole(s) provided. The pike pole(s) will be a Fire Hooks Unlimited 10' pike pole. PIKE POLE STORAGE One (1) pike pole, 8' or longer, will be provided with a 1.38" notch, to accommodate a New York style pike polepainted aluminum and located behind the ladders on the right side. 6' PIKE POLE PROVIDED BY FIRE DEPARTMENT The pike pole is not on the apparatus as manufactured. The fire department will provide and mount the pike poles. There will be one (1) 6' pike pole(s) provided. The pike pole(s)will be a Fire Hooks Unlimited 6' New York pike pole. PIKE POLE STORAGE There will be One (1) pike pole 6' pike pole(s)with a 1.38" notch, to accommodate a New York style pike pole stored in painted aluminum tube(s) located behind the ladders on right side FOLDING STEPS FRONT OF BODY Folding steps will be provided full height on the left side body compartments to provide access to the cargo bed. Steps will be spaced evenly on the sales drawing. Actual quantity may vary due to pump panel interferences but will meet the NFPA required maximum stepping height. The Trident steps will be bright finished, non-skid with a black tread coating on the stepping surface. The step will incorporate an LED light to illuminate the stepping surface. The steps can be used as a hand hold with two openings wide enough for a gloved hand. REAR FOLDING STEPS Bright finished, non-skid folding steps with a black tread coating on the stepping surface will be provided at the rear. Each step will incorporate an LED light to illuminate the stepping surface. The steps can be used as a hand hold with two openings wide enough for a gloved hand. PUMP COMPARTMENT The pump compartment will be separate from the hose body and compartments so that each may flex independently of the other. The pump compartment will be constructed of the same material as the body compartmentation. Port Arthur Stock Saber Pumper The pump compartment substructure will be a fabricated assembly of steel tubing, angles and channels which supports both the fire pump and the side running boards. The pump compartment will be mounted on the chassis frame rails with rubber biscuits in a four point pattern to allow for chassis frame twist. Pump compartment, pump, plumbing and gauge panels will be removable from the chassis in a single assembly. PUMP MOUNTING Pump will be mounted to a substructure which will be mounted to the chassis frame rail using rubber isolators. The mounting will allow chassis frame rails to flex independently without damage to the fire pump. LEFT SIDE PUMP CONTROL PANEL All pump controls and gauges will be located at the left (driver's) side of the apparatus and properly identified. Layout of the pump control panel will be ergonomically efficient and systematically organized. The pump operator's control panel will be removable in two (2) main sections for ease of maintenance: The upper section will contain sub panels for the mounting of the pump pressure control device, engine monitoring gauges, electrical switches, and foam controls (if applicable). Sub panels will be removable from the face of the pump panel for ease of maintenance. Below the sub panels will be located all valve controls and line pressure gauges. The lower section of the panel will contain all inlets, outlets, and drains. All push/pull valve controls will have 1/4 turn locking control rods with polished chrome plated zinc tee handles. Guides for the push/pull control rods will be chrome plated zinc castings securely mounted to the pump panel. Push/pull valve controls will be capable of locking in any position. The control rods will pull straight out of the panel and will be equipped with universal joints to eliminate binding. IDENTIFICATION TAGS The identification tag for each valve control will be recessed in the face of the tee handle. All discharge outlets will have color coded identification tags, with each discharge having its own unique color. Color coding will include the labeling of the outlet and the drain for each corresponding discharge. All line pressure gauges will be mounted directly above the corresponding discharge control tee handles and recessed within the same chrome plated casting as the rod guide for quick identification. The gauge and rod guide casting will be removable from the face of the pump panel for ease of maintenance. The casting will be color coded to correspond with the discharge identification tag. All remaining identification tags will be mounted on the pump panel in chrome plated bezels. The pump panel on the right (passenger's) side will be removable with lift and turn type fasteners. Port Arthur Stock Saber Pumper Trim rings will be installed around all inlets and outlets. PUMP Pump will be a Waterous CSU, 1500 gpm single (1) stage midship mounted centrifugal type. Pump will be the class "A" type. Pump will deliver the percentage of rated discharge at pressures indicated below: • 100 percent of rated capacity at 150 psi net pump pressure. • 70 percent of rated capacity at 200 psi net pump pressure. • 50 percent of rated capacity at 250 psi net pump pressure. Pump body will be close-grained gray iron, bronze fitted, and horizontally split in two (2) sections for easy removal of the entire impeller shaft assembly (including wear rings). Pump will be designed for complete servicing from the bottom of the truck, without disturbing the pump setting or apparatus piping. Pump case halves will be bolted together on a single horizontal face to minimize chance of leakage and facilitate ease of reassembly. No end flanges will be used. Discharge manifold of the pump will be cast as an integral part of the pump body assembly and will provide a minimum of three (3) 3.50" openings for flexibility in providing various discharge outlets for maximum efficiency. The three (3) 3.50" openings will be located as follows: one (1) outlet to the right of the pump, one (1) outlet to the left of the pump, and one (1) outlet directly on top of the discharge manifold. Impeller shaft will be stainless steel, accurately ground to size. It will be supported at each end by sealed, anti-friction ball bearings for rigid precise support. Impeller will have flame plated hubs assuring maximum pump life and efficiency despite any presence of abrasive matter in the water supply. Bearings will be protected from water and sediment by suitable stuffing boxes, flinger rings, and oil seals. No special or sleeve type bearings will be used. Pump will be equipped with a self-adjusting, maintenance-free, mechanical shaft seal. The mechanical seal will consist of a flat, highly polished, spring fed carbon ring that rotates with the impeller shaft. The carbon ring will press against a highly polished stainless steel stationary ring that is sealed within the pump body. In addition, a throttling ring will be pressed into the steel chamber cover, providing a very small clearance around the rotating shaft in the event of a mechanical seal failure. The pump performance will not deteriorate, nor will the pump lose prime, while drafting if the seal fails during pump operation. Wear rings will be bronze and easily replaceable to restore original pump efficiency and eliminate the need to replace the entire pump casing due to wear. Port Arthur Stock Saber Pumper PUMP TRANSMISSION The pump transmission will be made of a three (3) piece, aluminum, horizontally split casing. Power transfer to pump will be through a high strength Morse HY-VO silent drive chain. By using a chain rather than gears, 50 percent of the sprocket will be accepting or transmitting torque, compared to two (2) or three (3) teeth doing all the work. Drive shafts will be 2.35" diameter hardened and ground alloy steel and supported by ball bearings. The case will be designed to eliminate the need for water cooling. PUMPING MODE An interlock system will be provided to ensure that the pump drive system components are properly engaged so that the apparatus can be safely operated. The interlock system will be designed to allow stationary pumping only. AIR PUMP SHIFT Pump shift engagement will be made by a two (2) position sliding collar, actuated pneumatically (by air pressure), with a three (3) position air control switch located in the cab. A manual back-up shift control will also be located on the left side pump panel. Two (2) indicator lights will be provided adjacent to the pump shift inside the cab. One (1) green light will indicate the pump shift has been completed and be labeled "pump engaged". The second green light will indicate when the pump has been engaged, and that the chassis transmission is in pump gear. This indicator light will be labeled "OK to pump". The pump shift will be interlocked to prevent the pump from being shifted out of gear when the chassis transmission is in gear to meet NFPA requirements. The pump shift control in the cab will be illuminated to meet NFPA requirements. TRANSMISSION LOCK-UP The direct gear transmission lock-up for the fire pump operation will engage automatically when the pump shift control in the cab is activated. AUXILIARY COOLING SYSTEM A supplementary heat exchange cooling system will be provided to allow the use of water from the discharge side of the pump for cooling the engine water. The heat exchanger will be a separate unit. It will be installed in the pump or engine compartment with the control located on the pump operator's control panel. The exchanger will be plumbed to the master drain valve. INTAKE RELIEF VALVE - PUMP One (1) Elkhart Style 40 relief valve(s) will be installed on the suction side of the pump preset at 125 psig. The relief valve(s)will have a working range of 75 psi to 250 psi. The outlet will terminate below the frame rails with a 2.50" National Standard hose thread adapter and will have a "do not cap"warning tag. Port Arthur Stock Saber Pumper The relief valve pressure control will be located behind the right side pump panel with a stainless steel access door. PRESSURE CONTROLLER A FRC Pump Boss 500 electronic pressure controller with one (1) 600 PSI transducer on the pump discharge will be provided. All readouts will be standard PSI. When a single 300 psi or single 600 psi pressure transducer is selected the transducer is installed in the discharge side of the water pump. The transducer continuously monitors pump pressure sending a signal to the electronic pressure controller. When a dual 600 psi pressure transducer is selected the transducer are installed in the discharge side and intake side of the water pump. The discharge transducer continuously monitors pump pressure sending a signal to the electronic pressure controller. The intake transducer continuously monitors the pump intake sending a signal to the electronic pressure controller. The pressure controller can be used in two (2) modes of operation, RPM mode and pressure modes. The controller will be programmed to turn on/default to RPM Setting mode. In RPM mode, the controller can be activated after vehicle parking brake has been set. When in this mode, the controller will maintain the set engine speed, regardless of engine load (within engine operation capabilities). In pressure mode, the controller can be activated after vehicle parking brake has been set. When in this mode, the controller will automatically maintain the discharge pressure set by the operator(within the discharge capabilities of the pump and water supply) regardless of flow. A 2.00" diameter throttle control knob with no mechanical stops, a serrated grip, and a red idle push button in the center will be a integrated/part of the pressure controller. The throttle control knob will be programmed for Clockwise rotation to increase engine speed. Individual LED indicators for ok to pump, throttle ready, pressure mode and rpm mode will be located on the pressure controller for easy viewing. Safety features include recognition of low water and no water conditions with an automatic programmed response and a push button to return the engine to idle. An audible alarm will be provided on the pump operator's panel. The pressure controller screen will be LCD. The LCD screen and LED intensity will be automatically adjust for day and nighttime operation. The LCD screen intensity can also be manually adjusted if needed. The following information will be provided/displayed on the LCD screen: • Engine RPM • Check engine and stop engine warning indicators • Engine oil pressure Port Arthur Stock Saber Pumper • Engine coolant temperature • Transmission Temp • Battery voltage • Operating mode (RPM or pressure) • Pressure or RPM setting On screen messaging show diagnostic and warning messages as they occur. It will show apparatus information, stored data, and program options when selected by the operator. It will monitor inputs outputs and support audible and visual warning alarms for the following conditions: • High battery voltage • Low battery voltage/engine off • Low battery voltage/engine running • High water pump temperature • Low engine oil pressure • High engine coolant temperature • No engine response (visual alarm only) The pressure controller will store the accumulated operating hours for the pump and engine. These items are to be displayed within the pressure controller menu. The pressure controller will include a USB port on the back of the controller for easy software upgrades if needed. PRIMING PUMP The priming pump will be a Trident Emergency Products compressed air powered, high efficiency, multistage venturi based AirPrime System, conforming to standards outlined in the current edition of applicable NFPA standards. All wetted metallic parts of the priming system are to be of brass and stainless steel construction. One (1) priming control will open the priming valve and start the pump primer. PUMP MANUALS There will be a total of two (2) pump manuals provided by the pump manufacturer and furnished with the apparatus. The manuals will be provided by the pump manufacturer in the form of two (2) electronic copies. Each manual will cover pump operation, maintenance, and parts. STAINLESS STEEL AND HOSE PLUMBING All inlet and outlet lines will be plumbed with either stainless steel pipe, flexible polypropylene tubing or synthetic rubber hose reinforced with hi-tensile polyester braid. All hoses will be equipped with brass or stainless steel couplings. All stainless steel hard plumbing will be a minimum of a schedule 10 wall thickness. Where vibration or chassis flexing may damage or loosen piping or where a coupling is required for servicing, the piping will be equipped with victaulic or rubber couplings. Port Arthur Stock Saber Pumper Plumbing manifold bodies will be ductile cast iron or stainless steel. All piping lines are to be drained through a master drain valve or will be equipped with individual drain valves. All drain lines will be extended with a hose to drain below the chassis frame. All water carrying gauge lines will be of flexible polypropylene tubing. All piping, hose and fittings will have a minimum of a 500 psi hydrodynamic pressure rating. FOAM SYSTEM PLUMBING All piping that is in contact with the foam concentrate or foam/water solution will be stainless steel. The fittings will be stainless steel or brass. Cast iron pump manifolds will be allowed. MAIN PUMP INLETS A 6.00" pump manifold inlet will be provided on each side of the vehicle. The suction inlets will include removable die cast zinc screens that are designed to provide cathodic protection for the pump, thus reducing corrosion in the pump. SHORT SUCTION TUBE(S) The suction tube(s) on the water pump will have short suction tube(s) installed to allow for installation of adapters, elbows or intake valves without excessive overhang. MAIN PUMP INLET CAP The main pump inlets will have National Standard Threads with a long handle chrome cap. • ,--- The cap will be the Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected. VALVES 4' All ball valves will be Akron® Brass. The Akron valves will be the 8000 series heavy-duty style with a stainless steel ball and a simple two-seat design. No lubrication or regular maintenance is required on the valve. Valves will have a ten (10) year warranty. The location of the valve for the one (1) inlet will be recessed behind the pump panel. INLET CONTROL The side auxiliary inlet(s)will incorporate a quarter-turn ball valve with the control located at the inlet valve. The valve operating mechanism will indicate the position of the valve. LEFT SIDE INLET There will be one (1) auxiliary inlet with a 2.50" valve at the left side pump panel, terminating with a 2.50" (F) National Standard hose thread adapter. The auxiliary inlet will be provided with a strainer, chrome swivel and plug. Port Arthur Stock Saber Pumper FRONT INLET A 6.00" inlet front inlet that terminates on top of the right side bumper extension will be provided. The plumbing will consist of 5.00" stainless steel and a 4.00" ball valve. Only radius elbows will be used in the piping, no mitered joints. Drains will be furnished in all the low points of piping and have .75" valves with T swing handle. Bleeder valves will be located near the threaded connection and the valve control. Die cast zinc screens will be provided at the front inlet connection. FRONT INLET CONTROL The front inlet will be gated and controlled with an Akron 9343 electric valve controller provided on the pump operators panel. The electric control must be of a true position feedback design, requiring no clutches in the motor or current limiting. The unit must be completely sealed with momentary open, close as well and an optional one touch full open feature to operate the valve actuator. The con troller will provide position indication with 5 colored LED's. It will have manual adjustment of the brightness as well as an auto dimming option. FRONT INLET INTAKE RELIEF VALVE An Elkhart Brass Style 40 intake pressure relief valve will be provided on the inlet side of the valve preset at 125 psig. The pressure relief valve will be adjustable from 75 to 250 psi. The outlet will be 2.50" National Standard hose thread and terminate below the frame rails and will have a "do not cap" warning tag near the discharge outlet. FRONT INLET ELBOW The front inlet will have a 6.00" inlet elbow with swivel, terminating with Male National Standard Hose Thread. The swivel will be Chrome. A petcock/snubber style of bleeder will be provided on the front inlet elbow. FRONT INLET CAP The front inlet will have National Standard hose threads with a long handle cap. The cap will incorporate a thread design to automatically relieve stored pressure in the line when disconnected. INLET BLEEDER VALVE A 0.75" bleeder valve will be provided for each side gated inlet. The valves will be located behind the panel with a "T" swing style handle control extended to the outside of the panel. Port Arthur Stock Saber Pumper The handles will be chrome plated and provide a visual indication of valve position. The swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage. The water discharged by the bleeders will be routed below the chassis frame rails. TANK TO PUMP The booster tank will be connected to the intake side of the pump with stainless steel piping and a quarter turn 3.00"full flow line valve with the control remotely located at the operator's panel. Tank to pump line will run straight (no elbows)from the pump into the front face of the water tank and angle down into the tank sump. A rubber coupling will be included in this line to prevent damage from vibration or chassis flexing. A check valve will be provided in the tank to pump supply line to prevent the possibility of"back filling" the water tank. TANK REFILL A 1.50" combination tank refill and pump re-circulation line will be provided, using a quarter-turn full flow ball valve controlled from the pump operator's panel. DISCHARGE OUTLET CONTROLS The discharge outlets will incorporate a quarter-turn ball valve with the control located at the pump operator's panel. The valve operating mechanism will indicate the position of the valve. If a handwheel control valve is used, the control will be a minimum of a 3.90" diameter stainless steel handwheel with a dial position indicator built into the center of the handwheel. Any 3.00 inch or larger discharge valve will be a slow-operating valve to meet current edition of applicable NFPA standards. LEFT SIDE DISCHARGE OUTLETS One (1) discharge outlet with a 2.50" valve will be provided on the left side of the apparatus, terminating with a 2.50" (M) National Standard hose thread adapter. LEFT SIDE OUTLET ELBOWS The 2.50" discharge outlets located on the left side pump panel will be furnished with a 2.50" (F) National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45 degree elbow. The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected. RIGHT SIDE DISCHARGE OUTLET One (1) discharge outlet with a 2.50" valve will be provided on the right side of the apparatus, terminating with a 2.50" (M) National Standard hose thread adapter. Port Arthur Stock Saber Pumper RIGHT SIDE OUTLET ELBOWS The 2.50" discharge outlets located on the right side pump panel will be furnished with a 2.50" (F) National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45 degree elbow. The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected. LARGE DIAMETER DISCHARGE OUTLET There will be an Akron 8800 4.00" flat ball valve with 4.00" plumbing terminating with a 4.00" MNST chrome adapter on the right side pump panel. The valve will be controlled with a(n) Pierce large handwheel with indicator located at the pump operator's panel. LARGE DIAMETER OUTLET ELBOWS The 4.00" outlet(s)will be furnished with one (1)4.00" (F) National Standard hose thread x 5.00" Storz elbow adapter with Storz cap. FRONT DISCHARGE OUTLET There will be one (1) 1.50" discharge outlet piped to the front of the apparatus and located in the center bumper tray. Plumbing will consist of 2.00" piping and flexible hose with a 2.00" ball valve with control at the pump operator's panel. A fabricated weldment made of stainless steel pipe will be used in the plumbing where appropriate. The piping will terminate with a 1.50" NST with 90 degree stainless steel swivel. There will be automatic drains provided at all low points of the piping. REAR DISCHARGE OUTLET There will be Two (2) discharge outlets piped to the rear of the hose bed, one (1) each side, installed so proper clearance is provided for spanner wrenches or adapters. Plumbing will consist of 2.50" piping along with a 2.50"full flow ball valve with the control from the pump operator's panel. REAR OUTLET ELBOWS The 2.50" discharge outlets located at the rear of the apparatus will be furnished with a 2.50" (F) National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45 degree elbow. The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected. DISCHARGE CAPS/ INLET PLUGS Chrome plated, rocker lug, caps with chain will be furnished for all discharge outlets 1.00" thru 3.00" in size, besides the pre-connected hose outlets. Chrome plated, rocker lug, plugs with chain will be furnished for all auxiliary inlets 1.00" thru 3.00" in size. Port Arthur Stock Saber Pumper The caps and plugs will incorporate a thread design to automatically relieve stored pressure in the line when disconnected. OUTLET BLEEDER VALVE A 0.75" bleeder valve will be provided for each outlet 1.50" or larger. Automatic drain valves are acceptable with some outlets if deemed appropriate with the application. The valves will be located behind the panel with a T swing style handle control extended to the outside of the side pump panel. The handles will be chrome plated and provide a visual indication of valve position. The T swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage. Bleeders will be located at the bottom of the pump panel. They will be properly labeled identifying the discharge they are plumbed in to. The water discharged by the bleeders will be routed below the chassis frame rails. DELUGE RISER A 3.00" deluge riser will be installed above the pump in such a manner that a monitor can be mounted and used effectively. Piping will be rigidly braced and installed securely so no movement develops when the line is charged. The riser will be gated and controlled at the pump operator's panel. Any 3.00 inch or larger discharge valve will be a slow-operating valve in accordance with NFPA 13.7.5.3. MONITOR A customer/dealer supplied and installed make and model none required or specified monitor will be properly installed on the deluge riser. The deluge riser will have male National Pipe Threads for mounting the monitor. CROSSLAY HOSE BEDS Two (2) crosslays with 1.50" outlets will be provided. Each bed to be capable of carrying 200' of 1.75" double jacketed hose and will be plumbed with 2.00" i.d. pipe and gated with a 2.00" quarter turn ball valve. Outlets to be equipped with a 1.50" National Standard hose thread 90 degree swivel located in the hose bed so that hose may be removed from either side of apparatus. The crosslay controls will be at the pump operator's panel. The center crosslay dividers will be fabricated of 0.25" aluminum and will provide adjustment from side to side. The divider will be unpainted with a brushed finish. Vertical scuffplates constructed of polished stainless steel will be provided at the front and rear ends of the bed on each side of vehicle. Port Arthur Stock Saber Pumper Crosslay bed flooring will consist of removable perforated brushed aluminum. 2.50" CROSSLAY HOSE BED One (1) crosslay with 2.50" outlets will be provided. This bed to be capable of carrying 200' of 2.50" double jacketed hose and will be plumbed with 2.50" i.d. pipe and gated with a 2.50" quarter turn ball valve. 1 Outlet to be equipped with a 2.50" National Standard hose thread 90 degree swivel located in the hose bed so that hose may be removed from either side of apparatus. The crosslay control will be at the pump operator's panel. When used in conjunction with other crosslay/speedlay/deadlay configurations, a center crosslay divider, when needed, will be fabricated of .25" aluminum and will provide adjustment from side to side. The divider will have an unpainted finish. The remaining inside area of the crosslay bed will be unpainted with a DA sanded finish. Stainless steel vertical scuffplates will be provided at hose bed ends (each side of vehicle). Bottom of hose bed ends (each side)will also be equipped with a stainless steel scuffplate. Crosslay bed flooring will consist of removable perforated brushed aluminum. CROSSLAY HOSE RESTRAINT A 2.00" black nylon webbing design restraint will be provided at each of the ends of three (3) crosslay(s)to secure the hose during travel. The webbing assembly is to be attached at the bottom of the crosslays, with footman loops and a permanent attachment, and is to attach at the top outside corners with seat belt buckles. The female end of the seat buckle will be permanently attached at the top corner of the opening. A bar will be attached to the female ends of the seat belt buckles to allow a single pull release. A single orange nylon strap will be attached to the bar for releasing the buckles on the webbing. CROSSLAY/DEADLAY HOSE RESTRAINT The crosslay/deadlay hosebed(s)will have two (2) 2.00" wide black nylon straps with Velcro fasteners provided across the top to secure the hose during travel. The straps will extend from the front to back across the top of the hosebed(s). CROSSLAY 8.00" LOWER THAN STANDARD The crosslays will be lowered 8.00" from standard. HUSKY 3/12 FOAM SYSTEM PLUMBING (FUTURE INSTALLATION) Foam manifold/piping will be provided for the future installation of a Husky 3/12 foam system. The foam system will be plumbed to 3-Crosslays 1-Front bumper outlet 1-Left rear outlet discharges. Port Arthur Stock Saber Pumper A foam manifold will be provided for the foam ready discharges. The plumbing from the water pump to the foam manifold will be designed to allow a Husky 3 or Husky 12 foam system to be added without much unnecessary rework. Space will be provided on the pump panel for the possible addition of the foam system controls. FOAM TANK The foam tank will be an integral portion of the polypropylene water tank. The cell will have a capacity of 20 gallons of foam with the intended use of Class A foam. The foam cell will not reduce the capacity of the water tank. The foam cell will have a screen in the fill dome and a breather in the lid. FOAM TANK DRAIN The foam tank drain will be a 1.00" drain valve located inside the pump compartment accessible through a door on the right side pump panel. PUMP PANEL CONFIGURATION The pump panel configuration will be arranged and installed in an organized manner that will provide user-friendly operation. PUMP AND GAUGE PANEL The pump and gauge panels will be constructed of aluminum with a black vinyl finish. A polished aluminum trim molding will be provided around each panel. PUMP ACCESS Right Side Panel The right side upper pump panel will be removable. Panel Fastener The removable panels will be secured with black swell latch. The left side pump panels will be attached with screws. The right side lower pump panel (drain bank) will be attached with screws. PUMP COMPARTMENT LIGHT There will be one (1) Whelen®, Model 3SCOCDCR, 3.00" white 12 volt DC LED light(s) with Whelen, Model 3FLANGEC, flange(s) installed in the pump compartment. Engine monitoring graduated LED indicators will be incorporated with the pressure controller. Also provided at the pump panel will be the following: - Master Pump Drain Control THROTTLE READY GREEN INDICATOR LIGHT There will be a green indicator light integrated with the pressure governor and/or engine throttle installed on the pump operators panel that is activated when the pump is in throttle ready mode. Port Arthur Stock Saber Pumper OK TO PUMP INDICATOR LIGHT There will be a green indicator light installed on the pump operators panel that is activated when the pump is in Ok To Pump mode. AIR HORN SWITCH An air horn control switch will be provided at the pump operator's control panel. This switch will be momentary red and properly labeled. The switch will be located within easy reach of the operator in the electrical switch panel. VACUUM AND PRESSURE GAUGES The pump vacuum and pressure gauges will be liquid filled and manufactured by Class 1 Incorporated. The gauges will be a minimum of 4.00" in diameter and will have white faces with black lettering, with a pressure range of 30.00"-0-600#. Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded retaining nut. The pump pressure and vacuum gauges will be installed adjacent to each other at the pump operator's control panel. Test port connections will be provided at the pump operator's panel. One (1) will be connected to the intake side of the pump, and the other to the discharge manifold of the pump. They will have 0.25 in. standard pipe thread connections and non-corrosive polished stainless steel or brass plugs. They will be marked with a label. This gauge will include a 10 year warranty against leakage, pointer defect, and defective bourdon tube. PRESSURE GAUGES The individual "line" pressure gauges for the discharges will be Class 1 interlube filled. They will be a minimum of 2.00" in diameter and have white faces with black lettering. Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded retaining nut. Gauges will have a pressure range of 30"-0-400#. The individual pressure gauge will be installed as close to the outlet control as practical. This gauge will include a 10 year warranty against leakage, pointer defect, and defective bourdon tube. WATER LEVEL GAUGE There will be an electronic water level gauge provided on the operator's panel that registers water level by means of five (5) colored LED lights. The lights will be durable, ultra-bright five (5) LED design viewable through 180 degrees. The water level indicators will be as follows: • 100 percent = Green • 75 percent = Yellow Port Arthur Stock Saber Pumper • 50 percent = Yellow • 25 percent = Yellow • Refill = Red The light will flash when the level drops below the given level indicator to provide an eighth of a tank indication. To further alert the pump operator, the lights will flash sequentially when the water tank is empty. The level measurement will be based on the sensing of head pressure of the fluid in the tank. The display will be constructed of a solid plastic material with a chrome plated die cast bezel to reduce vibrations that can cause broken wires and loose electronic components. The encapsulated design will provide complete protection from water and environmental elements. An industrial pressure transducer will be mounted to the outside of the tank. The field calibratable display measures head pressure to accurately show the tank level. The main water level gauge will be powered with battery switch. There will be a Hale part number 106877, 4-light driver module included with this installation to power additional water level gauges. The remote level lights will be energized when pump is in gear. WATER LEVEL GAUGE There will be two (2) additional water level indicator, Whelen®, Model PSTANK2, LED module with a chrome trim, installed one (1) each side rearward of crew cab doors. This light module will include four(4) colored levels, and function similar to the water level indicator located at the operators panel: • First green module indicates a full water level • Second blue module indicates a water level above 3/4 full • Third amber module indicates a water level above 1/2 full • Last red module indicates a water level above 1/4 full and empty o Above 1/4 this light will be steady burning o At empty this light will be flashing This module will be activated when the pump is in gear. FUTURE FOAM LEVEL GAUGE Provision will be provided in the foam cell for the future addition of a foam system and level gauge. LIGHT SHIELD There will be a polished, 16 gauge stainless steel light shield installed over the pump operators panel. The light shield will be split into two separate pieces to provide illumination of the entire pump operators panel. Port Arthur Stock Saber Pumper • There will be 12 volt DC white LED lights installed under the stainless steel light shield to illuminate the controls, switches, essential instructions, gauges, and instruments necessary for the operation of the apparatus. These lights will be activated by the pump panel light switch. Additional lights will be included every 18.00" depending on the size of the pump house. • One (1) pump panel light will come on when the pump is in ok to pump mode. The switch panel will be lit when the parking brake is set. This is to afford the operator illumination when first approaching the control panel. AIR HORN SYSTEM Two (2) Hadley®, eTone, chrome air horns will be recessed in the front bumper. The air horn system will be piped to the air brake system wet tank utilizing 0.38" tubing. A pressure protection valve will be installed to prevent the loss of air in the brake system. Air Horn Location The air horns will be located on each side of the bumper, towards the outside. Air Horn Control The air horns will be actuated by a chrome push button located on the officer's side of the engine tunnel and by the horn button in the steering wheel. The driver will have the option to control the air horns or the chassis horns from the horn button by means of a selector switch located on the instrument panel. ELECTRONIC SIREN A Whelen®, Model 295SLSA1, electronic siren with noise canceling microphone will be provided. This siren to be active when the battery switch is on and that emergency master switch is on. The electronic siren head will be located in switch panel # 7 area of the center dash switch panel. The electronic siren will be controlled on the siren head only. No horn button or foot switches will be provided. SPEAKER There will be one (1) Whelen®, Model SA315P, black nylon composite, 100-watt, speaker with through bumper mounting brackets and polished stainless steel grille provided. The speaker will be connected to the siren amplifier. The speaker(s)will be recessed in the center of the front bumper. AUXILIARY MECHANICAL SIREN There will be a Federal Signal Model Q2B mechanical siren furnished and installed in the front of the apparatus. The Q2B will be chrome finish. The siren will have a 2-gauge cable connected to a power solenoid that is connected by a 2-gauge cable ran battery direct to the primary chassis batteries and will be labeled Q2B+ at the battery. The power solenoid will only be enabled when the emergency master switch is on. Port Arthur Stock Saber Pumper The siren will have a 2-gauge ground wire connected to the chassis battery stud. The cable will be labeled Q2B- at the battery. The mechanical siren will be recessed in the front bumper on the left side. The siren will be properly supported using the bumper framework. MECHANICAL SIREN CONTROL The mechanical siren will be activated by the following: • Left side foot switch. A momentary chrome push button switch will be included in the right side dash panel to activate the siren brake. EMERGENCY WARNING SYSTEM CONTROL There will be an Emergency Warning System provided. The warning system will meet the current NFPA Requirements and be enabled and disabled through switches per the instrument panel layout. Emergency switching will be controlled by multiple individual warning light switches for various groups or areas of emergency warning lights. An Emergency Master switch provided on the instrument panel that enables or disables all individual warning light switches is included. Flash patterns and flash rates will be set through the individual lightheads per the manufacturer. FRONT ZONE UPPER WARNING LIGHTS There will be one (1) 60.00"Whelen Freedom IV LED lightbar mounted on the cab roof. The lightbar will include the following: • One (1) red flashing LED module in the driver's side rear corner position. • Open in the driver's side end position. • One (1) red flashing LED module in the driver's side front corner position. • One (1) red flashing LED module in the driver's side first front position. • Open in the driver's side second front position. • Open in the driver's side third front position. • Open in the driver's side fourth front position. • One (1) red flashing LED module in the driver's side fifth front position. • One (1) red flashing LED module in the passenger's side fifth front position. • Open in the passenger's side fourth front position. • Open in the passenger's side third front position. • Open in the passenger's side second front position. • One (1) red flashing LED module in the passenger's side first front position. • One (1) red flashing LED module in the passenger's side front corner position. • Open in the passenger's side end position. • One (1) red flashing LED module in the passenger's side rear corner position. Port Arthur Stock Saber Pumper There will be clear lenses included on the lightbar. There will be a switch in the cab on the switch panel to control this lightbar. The four(4) red flashing LED modules in the front positions may be load managed when the parking brake is applied. LIGHTS, FRONT ZONE LOWER Two (2) Whelen model M6*C LED flashing warning lights will be installed on the cab face above the headlights, in a common bezel with the directional lights. The driver's side front warning light to be red. The passenger's side front warning light to be red. Both lights will include a clear lens. There will be a switch located in the cab on the switch panel to control the lights. HEADLIGHT FLASHER The high beam headlights will flash alternately between the left and right side. There will be a switch installed in the cab on the switch panel to control the high beam flash. This switch will be live when the battery switch and the emergency master switches are on. The flashing will automatically cancel when the hi-beam headlight switch is activated or when the parking brake is set. SIDE ZONE LOWER LIGHTING There will be six (6) Whelen®, Model M6*C, flashing LED warning lights with chrome trim installed per the following: • Two (2) lights, one (1) each side on the bumper extension. The side front lights to be red. • Two (2) lights, one (1) each side above the front wheels. The side middle lights to be red. • Two (2) lights, one (1) each side above rear wheels. The side rear lights to be red. • The lights will include clear lenses. There will be a switch in the cab on the switch panel to control the lights. SIDE WARNING LIGHTS There will be four(4) Whelen®, Model TSSO*, 1.49" high x 5.14" long x 0.54" deep flashing LED warning light(s)with chrome trim and lens color(s) to be clear lens(es) located, two each side body rub rails. The light(s) to include red LEDs. The light(s) will be activated with the side warning switch. The light(s) may be load managed when the parking brake is applied. Port Arthur Stock Saber Pumper White LEDs will be deactivated when the parking brake is applied. REAR ZONE LOWER LIGHTING There will be two (2) Whelen®, Model M6*C, LED flashing warning lights located at the rear of the apparatus. • The driver's side rear light to be red • The passenger's side rear light to be red Both lights will include a lens that is clear. There will be a switch located in the cab on the switch panel to control the lights. REAR/SIDE ZONE UPPER WARNING LIGHTS There will be two (2) Whelen®, Model L31 H*FN, LED warning beacons provided at the rear of the truck, located one (1) each side. There will be a switch located in the cab on the switch panel to control the beacons. The color of the lights will be red LEDs with both domes clear. The left side rear warning light will be mounted on top of the compartmentation with all wiring totally enclosed. The clearance/marker light will be mounted to the side of the compartment ridge. The right side rear warning light will be mounted on a low mount stainless steel bracket with all wiring totally enclosed. The brackets will also support the clearance/marker light. The rear deck lights will be mounted on the beavertail flange to keep the overall height as low as possible. TRAFFIC DIRECTING LIGHT There will be six (6)Whelen® Model WIONSMC*, 1.68" high x 5.93" long x 1.12" deep lights with amber LEDs, clear lenses and chrome trim installed at the rear of the apparatus. There will be one (1)Whelen, Model TACTL5 control head energized when the battery switch is on included with this installation. The available flash patterns are: left arrow, right arrow, split and flash (center out and wig-wag) will be provided. The with the control head only. This traffic directing light will be surface mounted over the rear door, at the rear of the apparatus as high as practical. The traffic directing light controller will be located within switch panel #11 on the center console. Port Arthur Stock Saber Pumper 120 VOLT RECEPTACLE There will be one (1), 15/20 amp 120 volt AC three (3) wire straight blade duplex receptacle(s) with interior red plastic wall plate(s), installed upper center rear wall of EMS cabinet. The NEMA configuration for the receptacle(s) will be 5-20R. The receptacle(s)will be powered from the shoreline inlet. There will be a label installed near the receptacle(s) that state the following: • Line Voltage • Current Ratting (amps) • Phase • Frequency POWER OUTLET STRIP There will be two (2) receptacle strip(s)with six (6) 15 amp 120 volt AC straight blade receptacles provided rear wall, centered, high as possible, in LS1 and LS3. The strip(s) selected will be powered from the shoreline inlet through a receptacle located adjacent to the strip(s). There will be a label installed near the strip(s) that state the following: • Line Voltage • Current Ratting (amps) • Phase • Frequency LOOSE EQUIPMENT The following equipment will be furnished with the completed unit: • One (1) bag of chrome, stainless steel, or cadmium plated screws, nuts, bolts and washers, as used in the construction of the unit. NFPA LOOSE EQUIPMENT NFPA Required Loose Equipment Provided by Fire Department The following loose equipment as outlined in NFPA 1900, 2024 edition, table 8.1 and CAN/ULC 515:2024 edition, section 5.2 will be provided by the fire department: • One (1) traffic vest for each seating position, each vest to comply with ANSI/ISEA 207, Standard for High Visibility Public Safety Vests, and have a five-point breakaway feature that includes two (2) at the shoulders, two (2) at the sides, and one (1) at the front. • Five (5) fluorescent orange traffic cones not less than 28.00" (711 mm) in height, each equipped with a 6.00" (152 mm) retro-reflective white band no more than 4.00" (152 mm)from the top of the cone, and an additional 4.00" (102 mm) retro-reflective white band 2.00" (51 mm) below the 6.00" (152 mm) band. Port Arthur Stock Saber Pumper • Five (5) illuminated warning devices such as highway flares, unless the five (5)fluorescent orange traffic cones have illuminating capabilities. NFPA Loose Equipment That Should be Considered The following loose equipment as outlined in NFPA 1900, 2024 edition, appendix table A.8.4 (a) and CAN/ULC 515:2024 edition, section 5.2 should be considered: • 800 ft (60 m) of 2.50" (65 mm) or larger fire hose. • 400 ft (120 m) of 1.50" (38 mm), 1.75" (45 mm), or 2.00" (52 mm)fire hose. • One (1) handline nozzle, 200 gpm (750 L/min) minimum. • Two (2) handline nozzles, 95 gpm (360 Umin) minimum. • One (1) smooth bore or combination nozzle with shutoff and with 2.50" (65 mm) inlet that flows a minimum of 250 gpm (950 L/min). • Four (4) SCBA apparatus • Four (4) SCBA spare cylinders • One (1)first aid kit. • Four(4) combination spanner wrenches. • Two (2) hydrant wrenches. • One (1) double female 2.50" (65 mm) adapter with national hose (NH)threads. • One (1) double male 2.50" (65 mm) adapter with national hose (NH) threads. • One (1) rubber mallet, for use on suction hose connections. • Two (2) salvage covers each a minimum size of 12 ft x 18 ft (3.7 m x 5.5 m). • One (1) automatic external defibrillator(AED). SOFT SUCTION HOSE There will be no soft suction hose provided. DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher. WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher. FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe. PICKHEAD AXE PROVIDED BY FIRE DEPARTMENT The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe. Port Arthur Stock Saber Pumper PAINT PROCESS The exterior custom cab and/or body painting procedure will consist of a seven (7) step finishing process. A commercial chassis paint process will follow similar processes as determined by the chassis manufacturer. The following procedure will be used by Pierce: 1. Manual Surface Preparation -All exposed metal surfaces on the custom cab and body will be thoroughly cleaned and prepared for painting. Imperfections on the exterior surfaces will be removed and sanded to a smooth finish. Exterior seams will be sealed before painting. Exterior surfaces that will not be painted include; chrome plating, polished stainless steel, anodized aluminum and bright aluminum treadplate. 2. Chemical Cleaning and Pretreatment-All surfaces will be chemically cleaned to remove dirt, oil, grease, and metal oxides to ensure the subsequent coatings bond well. The aluminum surfaces will be properly cleaned and treated using a high pressure, high temperature 4 step Acid Etch process. The steel and stainless surfaces will be properly cleaned and treated using a high temperature 3 step process specifically designed for steel or stainless. The chemical treatment converts the metal surface to a passive condition to help prevent corrosion. A final pure water rinse will be applied to all metal surfaces. 3. Surfacer Primer-The Surfacer Primer will be applied to a chemically treated metal surface to provide a strong corrosion protective base coat. A minimum thickness of 2 mils of Surfacer Primer is applied to surfaces that require a critical aesthetic finish. The surfacer primer will be a two-component high solids urethane that has excellent sanding properties and an extra smooth finish when sanded. 4. Finish Sanding - The surfacer primer will be sanded with a fine grit abrasive to achieve an ultra- smooth finish. This sanding process is critical to produce the smooth mirror like finish in the topcoat. 5. Sealer Primer- The sealer primer is applied prior to the base coat in all areas that have not been previously primed with the surfacer primer. The sealer primer is a two-component high solids urethane that goes on smooth and provides excellent gloss hold out when top coated. 6. Base coat Paint-Two coats of a high performance, two component high solids polyurethane base coat will be applied. The Base coat will be applied to a thickness that will achieve the proper color match. The Base coat will be used in conjunction with a urethane clear coat to provide protection from the environment. 7. Clear Coat -Two (2) coats of clear coat will be applied over the base coat color. The clear coat is a two-component high solids urethane that provides superior gloss and durability to the exterior surfaces. Lap style doors will be clear coated to match the body. Paint warranty for the roll-up doors will be provided by the roll-up door manufacturer. Our specifications are written to define cyclic corrosion testing, physical strengths, durability and minimum appearance requirements must be met in order for an exterior paint finish to be considered acceptable as a quality finish. Each batch of base coat color will be checked for a proper match before painting of the cab and the body. After the cab and body are painted, the color is verified again to make sure that it matches the color standard. Electronic color measuring equipment will be used to compare the color sample to the Port Arthur Stock Saber Pumper color standard entered into the computer. Color specifications are used to determine the color match. A Delta E reading will be used to determine a good color match within each family color. All removable items such as brackets, compartment doors, door hinges, and trim will be removed and separately if required, to ensure paint behind all mounted items. Body assemblies that cannot be finish painted after assembly will be finish painted before assembly. Environmental Impact Contractor will meet or exceed all current State regulations concerning paint operations. Pollution control will include measures to protect the atmosphere, water and soil. Controls will include the following conditions: • Topcoats and primers will be chrome and lead free. • Metal treatment chemicals will be chrome free. The wastewater generated in the metal treatment process will be treated on-site to remove any other heavy metals. • Particulate emission collection from sanding operations will have a 99.99 percent efficiency factor. • Particulate emissions from painting operations will be collected by a dry filter or water wash process. If the dry filter is used, it will have an efficiency rating of 98 percent. Water wash systems will be 99.97 percent efficient. • Water from water wash booths will be reused. Solids will be removed on a continual basis to keep the water clean. • Paint wastes will be disposed of in an environmentally safe manner. • Empty metal paint containers will be recycled to recover the metal. • Solvents used in clean-up operations will be recycled on-site or sent off-site for distillation and returned for reuse. Additionally, the finished apparatus will not be manufactured with or contain products that have ozone depleting substances. Pierce will, upon demand, present evidence that the manufacturing facility meets the above conditions and that it is in compliance with the state EPA rules and regulations. CAB PAINT The cab will be painted #90 red. BODY PAINT The body will be painted to match the single cab#90 red paint color. PAINT CHASSIS FRAME ASSEMBLY The chassis frame assembly will be finished with a single system black top coat before the installation of the cab and body, and before FILM TECHNICAL POOPEk'IE iS installation of the engine and transmission assembly, air brake lines, cob, 1 1ST818114 0 0 electrical wire harnesses, etc. film Thickness - 05-1 5M11s Gloss•60 Degree ASTM D523 65-83 Pe01011 Hmdmss ASTM D3363 2H M9nimwn Components treated with epoxy E-coat protection prior to paint: Dino Impoc' AS1MD2794 '00al- °Mmun,on Rowse Import ASTM D2794 60.n Ibs Minimum Croubch Adh.sion ASTM 03359 48 38 • Two (2) C-channel frame rails HVMdisy ASTM D1735 1000 Hove MMnmam 'Naar Immersion ASTM 0870 250 Haas Mm.mum Growelomerr GM9508P 6 Minim ?Ivowpowor G8595358 12 15:n i?M nl'Me 0•4 ab oral,tur snnspko.a.4000a0n.0 6 a,*owns.Mw bola...-.J2a nM,.615C Port Arthur Stock Saber Pumper P AOcWT 100.10oUit Resistance COS/Zino'hoe 1 1 2 or, Mbnrhtan• Components that are included with the chassis frame assembly that will be painted not e-coated (unless otherwise stated in a secondary option) are: • Cross members • Axles • Suspensions • Steering gear • Battery boxes • Bumper extension weidment • Frame extensions • Body mounting angles • Rear Body support substructure (front and rear) • Pump house substructure • Steel fuel tank • Castings • Individual piece parts used in chassis and body assembly The E-coat process will meet the technical properties shown. AXLE HUB PAINT All axle hubs will be painted to match primary job color. COMPARTMENT INTERIOR PAINT The interior of all compartments will be painted with a gray spatter finish for ease of cleaning and to make it easier to touch up scratches and nicks. REFLECTIVE STRIPES Three (3) reflective stripes will be provided across the front of the vehicle and along the sides of the body. The reflective band will consist of a 1.00" white stripe at the top with a 1.00" gap then a 6.00" white stripe with a 1.00" gap and a 1.00"white stripe on the bottom. The reflective band provided on the cab face will be at the headlight level. REAR CHEVRON STRIPING There will be alternating chevron striping located on the rear-facing vertical surface of the apparatus. The entire rear surface, excluding the rear compartment door, will be covered. The colors will be Fluorescent Yellow-Green 983-23 and Red 983-72 diamond grade. Each stripe will be 6.00" in width. CAB DOOR REFLECTIVE STRIPE A 6.00"x 16.00"fluorescent yellow green diamond grade reflective stripe will be provided across the interior of each cab door. The stripe will be located approximately 1.00" up from the bottom, on the door panel. This stripe will meet the current edition of applicable NFPA standards. Port Arthur Stock Saber Pumper 1 FIRE APPARATUS PARTS MANUAL There will be one (1) custom parts manual(s) in USB flash drive format for the complete fire apparatus provided. The manual(s)will contain the following: • Job number • Part numbers with full descriptions • Table of contents • Parts section sorted in functional groups reflecting a major system, component, or assembly • Parts section sorted in alphabetical order • Instructions on how to locate parts Each manual will be specifically written for the chassis and body model being purchased. It will not be a generic manual for a multitude of different chassis and bodies. Service Parts Internet Site The service parts information included in these manuals are also available on the Pierce website. The website offers additional functions and features not contained in this manual, such as digital photographs and line drawings of select items. The website also features electronic search tools to assist in locating parts quickly. CHASSIS SERVICE MANUALS There will be one (1) chassis service manuals on USB flash drives containing parts and service information on major components provided with the completed unit. The manual will contain the following sections: • Job number • Table of contents • Troubleshooting • Front Axle/Suspension • Brakes • Engine • Tires • Wheels • Cab • Electrical, DC • Air Systems • Plumbing • Appendix The manual will be specifically written for the chassis model being purchased. It will not be a generic manual for a multitude of different chassis and bodies. Port Arthur Stock Saber Pumper CHASSIS OPERATION MANUAL The chassis operation manual will be provided on one (1) USB flash drive. The manual will be in the English language. ONE (1) YEAR MATERIAL AND WORKMANSHIP A Pierce basic apparatus limited warranty certificate, WA0008, is included with this proposal. ENGINE WARRANTY A Cummins five (5) year limited engine warranty will be provided. A limited warranty certificate, WA0181, is included with this proposal. STEERING GEAR WARRANTY A TRW one (1) year limited steering gear warranty will be provided. A copy of the warranty certificate will be submitted with the bid package. FIFTY (50) YEAR STRUCTURAL INTEGRITY The Pierce custom chassis frame only (does not include crossmembers) limited warranty certificate, WA0013, is included with this proposal. FRONT AXLE WARRANTY A two (2)year/250,000 mile Hendrickson Steertek front axle warranty will be provided. REAR AXLE WARRANTY A Eaton five (5)-year/100,000 mile parts and labor warranty will be provided. ABS BRAKE SYSTEM THREE (3) YEAR MATERIAL AND WORKMANSHIP WARRANTY A Meritor WabcoTM ABS brake system limited warranty certificate, WA0232, is included with this proposal. TEN (10) YEAR STRUCTURAL INTEGRITY The Pierce custom cab limited warranty certificate, WA0012, is included with this proposal. TEN (10) YEAR PRO-RATED PAINT AND CORROSION A Pierce cab limited pro-rated paint warranty certificate, WA0055, is included with this proposal. CAMERA SYSTEM WARRANTY A Pierce fifty four (54) month warranty will be provided for the camera system. COMPARTMENT LIGHT WARRANTY The compartment lights will not offer an extended warranty. TRANSMISSION WARRANTY The transmission will have a five (5) year/unlimited mileage warranty covering 100 percent parts and labor. The warranty will be provided by Allison Transmission. Note: The transmission cooler is not covered under any extended warranty you may be getting on your Allison Transmission. Please review your Allison Transmission warranty for coverage limitations. Port Arthur Stock Saber Pumper TRANSMISSION COOLER WARRANTY The transmission cooler will carry a five (5) year parts and labor warranty (exclusive to the transmission cooler). In addition, a collateral damage warranty will also be in effect for the first three (3) years of the warranty coverage and will not exceed $10,000 per occurrence. A copy of the warranty certificate will be included with this proposal. WATER TANK WARRANTY A UPF poly water tank limited warranty certificate, WA0195, is included with this proposal. TEN (10) YEAR STRUCTURAL INTEGRITY The Pierce apparatus body limited warranty certificate, WA0009, is included with this proposal. ROLL UP DOOR MATERIAL AND WORKMANSHIP WARRANTY An AMDOR roll-up door limited warranty will be provided. The roll-up door will be warranted against manufacturing defects for a period of ten (10) years. A five (5) year limited warranty will be provided on painted roll up doors. The limited warranty certificate, WA0185, is included with this proposal. PUMP WARRANTY The Waterous pump will be provided with a seven (7) year material and workmanship limited warranty. A copy of the warranty certificate will be included with this proposal. TEN (10) YEAR PUMP PLUMBING WARRANTY The Pierce apparatus plumbing limited warranty certificate, WA0035, is included with this proposal. TEN (10) YEAR PRO-RATED PAINT AND CORROSION A Pierce body limited pro-rated paint warranty certificate, WA0057, is included with this proposal. VEHICLE STABILITY CERTIFICATION The fire apparatus manufacturer will provide a certification stating the apparatus complies with NFPA 1900, current edition, section 7.14, Vehicle Stability. The certification is included with this proposal. ENGINE INSTALLATION CERTIFICATION The fire apparatus manufacturer will provide a certification, along with a letter from the engine manufacturer stating they approve of the engine installation in the bidder's chassis. The certification will be provided at the time of delivery. POWER STEERING CERTIFICATION The fire apparatus manufacturer will provide a certification stating the power steering system as installed meets the requirements of the component supplier. The certification is included with this proposal. CAB INTEGRITY CERTIFICATION The fire apparatus manufacturer will provide a cab crash test certification with this proposal. The certification will state that a specimen representing the substantial structural configuration of the cab has been tested and certified by an independent third party test facility. Testing events will be Port Arthur Stock Saber Pumper documented with photographs, real-time and high-speed video, vehicle accelerometers, cart accelerometers, and a laser speed trap. The fire apparatus manufacturer will provide a state licensed professional engineer to witness and certify all testing events. Testing will meet or exceed the requirements below: • SAE J2422 Cab Roof Strength Evaluation - Quasi-Static Loading Heavy Trucks. • European Occupant Protection Standard ECE Regulation No.29. • SAE J2420 COE Frontal Strength Evaluation - Dynamic Loading Heavy Trucks. Side Impact The cab will be subjected to dynamic preload where a 14,320-lb moving barrier is slammed into the side of the cab at 5.50 mph, striking with an impact of 13,000 ft-lb of force. This test is part of the SAE J2422 test procedure and more closely represents the forces a cab will see in a rollover incident. Frontal Impact The same cab will withstand a frontal impact of 32,600 ft-lb of force using a moving barrier in accordance with SAE J2420. Additional Frontal Impact The same cab will withstand a frontal impact of 65,098 ft-lb of force using a moving barrier. (Twice the force required by SAE J2420) Roof Crush The cab will be subjected to a roof crush force of 22,500 lb. This value meets the ECE 29 criteria, and is equivalent to the front axle rating up to a maximum of ten (10) metric tons. Additional Roof Crush The same cab will be subjected to a roof crush force of 110,000 lbs. (Four and a half times the load criteria of ECE 29) The same cab will withstand all tests without any measurable intrusion into the survival space of the occupant area. CAB DOOR DURABILITY CERTIFICATION Robust cab doors help protect occupants. Cab doors will survive a 200,000 cycle door slam test where the slamming force exceeds 20 G's of deceleration. The bidder will certify that the sample doors similar to those provided on the apparatus have been tested and have met these criteria without structural damage, latch malfunction, or significant component wear. WINDSHIELD WIPER DURABILITY CERTIFICATION Visibility during inclement weather is essential to safe apparatus performance. Windshield wipers will survive a 3 million cycle durability test in accordance with section 6.2 of SAE J198 Windshield Wiper Systems- Trucks, Buses and Multipurpose Vehicles. The bidder will certify that the wiper system design has been tested and that the wiper system has met these criteria. Port Arthur Stock Saber Pumper ELECTRIC WINDOW DURABILITY CERTIFICATION Cab window roll-up systems can cause maintenance problems if not designed for long service life. The window regulator design will complete 30,000 complete up-down cycles and still function normally when finished. The bidder will certify that sample doors and windows similar to those provided on the apparatus have been tested and have met these criteria without malfunction or significant component wear. SEAT BELT ANCHOR STRENGTH Seat belt attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat belt anchor design will withstand 3000 lb of pull on both the lap and shoulder belt in accordance with FMVSS 571.210 Seat Belt Assembly Anchorages. The bidder will certify that each anchor design was pull tested to the required force and met the appropriate criteria. SEAT MOUNTING STRENGTH Seat attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat mounting design will be tested to withstand 20 G's of force in accordance with FMVSS 571.207 Seating Systems. The bidder will certify, at time of delivery, that each seat mount and cab structure design was pull tested to the required force and met the appropriate criteria. STEPPING, STANDING &WALKING AREAS, SLIP RESISTANCE CERTIFICATION Pierce Manufacturing certifies that samples of the interior and exterior stepping, standing and walking surfaces used in the manufacture of Pierce custom and commercial fire apparatus will conform to the requirements of NFPA 1900, 2024 edition paragraphs 12.6.4.1 and 12.6.4.2 when tested using an English XL Variable Incidence Tribometer. PERFORMANCE CERTIFICATIONS Cab Air Conditioning Good cab air conditioning temperature and air flow performance keeps occupants comfortable, reduces humidity, and provides a climate for recuperation while at the scene. The cab air conditioning system will cool the cab from a heat-soaked condition at 100 degrees Fahrenheit to an average of 78 degrees Fahrenheit in 30 minutes. The bidder will certify that a substantially similar cab has been tested and has met these criteria. Cab Defroster Visibility during inclement weather is essential to safe apparatus performance. The defroster system will clear the required windshield zones in accordance with SAE J381 Windshield Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And Multipurpose Vehicles. The bidder will certify that the defrost system design has been tested in a cold chamber and passes the SAE J381 criteria. Cab Auxiliary Heater Good cab heat performance and regulation provides a more effective working environment for personnel, whether in-transit, or at a scene. An auxiliary cab heater will warm the cab 77 degrees Fahrenheit from a cold-soak, within 30 minutes when tested using the coolant supply methods found in Port Arthur Stock Saber Pumper SAE J381. The bidder will certify, at time of delivery, that a substantially similar cab has been tested and has met these criteria. AMP DRAW REPORT The bidder will provide, at the time of bid and delivery, an itemized print out of the expected amp draw of the entire vehicle's electrical system. The manufacturer of the apparatus will provide the following: • Documentation of the electrical system performance tests. • A written load analysis, which will include the following: o The nameplate rating of the alternator. o The alternator rating under the conditions specified per: • Current edition of applicable NFPA standards. o The minimum continuous load of each component that is specified per: • Current edition of applicable NFPA standards. o Additional loads that, when added to the minimum continuous load, determine the total connected load. o Each individual intermittent load. All of the above listed items will be provided by the bidder per the current edition of applicable NFPA standards. Port Arthur Stock Saber Pumper SEATING CAPACITY The seating capacity of the vehicle (including tiller cab and belted seat positions in the rescue body) will be six (6). DRIVER SEAT A seat will be provided in the cab for the driver. The seat design will be a cam action type, with air suspension. For increased convenience, the seat will include a manual control to adjust the horizontal position (6.00"travel). The manual horizontal control will be a towel-bar style located below the forward part of the seat cushion. To provide flexibility for multiple driver configurations, the seat will have an adjustable reclining back. The seat back will be a high back style with side bolster pads for maximum support. For optimal comfort, the seat will be provided with 17.00" deep foam cushions designed with EVC (elastomeric vibration control). The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A suspension seat safety system will be included. When activated in the event of a side roll, this system will pretension the seat belt and retract the seat to its lowest travel position. The seat will be furnished with a 3-point, shoulder type seat belt. OFFICER SEAT A seat will be provided in the cab for the passenger. The seat will be a fixed type, with no suspension. For optimal comfort, the seat will be provided with 17.00" deep foam cushions designed with EVC (elastomeric vibration control). The seat back will be an SCBA back style with 95 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt. The seat will be furnished with a 3-point, shoulder type seat belt. RADIO COMPARTMENT A radio compartment will be provided under the officer's seat. The inside compartment dimensions will be 14.00" wide x 7.50" high x 15.00" deep, with the back of the compartment angled up to match the cab structure. A drop-down door with one (1) lift and turn latch will be provided for access. Port Arthur Stock Saber Pumper The compartment will be constructed of smooth aluminum and painted to match the cab interior. REAR FACING DRIVER SIDE OUTBOARD SEAT There will be one (1) rear facing seat provided at the driver side outboard position in the crew cab. For optimal comfort, the seat will be provided with 15.00" deep foam cushions designed with EVC (elastomeric vibration control). The seat back will be an SCBA back style with 95 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt. The seat will be furnished with a 3-point, shoulder type seat belt. REAR FACING PASSENGER SIDE OUTBOARD SEAT There will be one (1) rear facing seat provided at the passenger side outboard position in the crew cab. For optimal comfort, the seat will be provided with 15.00" deep foam cushions designed with EVC (elastomeric vibration control). The seat back will be an SCBA back style with 95 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt. The seat will be furnished with a 3-point, shoulder type seat belt. FORWARD FACING DRIVER SIDE OUTBOARD SEAT There will be one (1) forward facing, foldup seat provided at the driver side outboard position in the crew cab. For optimal comfort, the seat will be a minimum of 15.00" from the front of the cushion to the face of the seat back and designed with EVC (elastomeric vibration control). The seat back will be an SCBA style with 90 degree back. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: Port Arthur Stock Saber Pumper • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt around the occupant to firmly hold them in place in the event of a side roll. The seat will be furnished with a 3-point, shoulder type seat belt. FORWARD FACING CENTER CABINET A forward facing cabinet will be provided in the crew cab at the center position. The cabinet will be 38.50" wide x 60.00" high x 28.00" deep with one (1)Amdor rollup door with anodized finish, locking with #751 key. The frame to frame opening of the cabinet will be 36.00" wide x 54.75" high. The minimum clear door opening will be 33.25"wide x 48.87" high. CLEAR DOOR OPENINGS F-F=Frame to Frame) AMDOR GORTITE ROM HORIZONTAL VERTICAL HORIZONTAL VERTICAL HORIZONTAL VERTICAL Subtract 2.00" Subtract 5.88" Subtract 2.75" Subtract 4.75" Subtract 2.56" Subtract 4.50" from F-F from F-F from F-F from F-F from F-F from F-F The cabinet will include two (2) infinitely adjustable shelves with a 1.25" up-turned lippainted to match the cab interior. The cabinet will include no louvers. The cabinet will be constructed of smooth aluminum, and painted to match the cab interior. Cabinet Light There will be one (1) red Amdor LED strip light installed on the left side of the interior cabinet door opening and one (1) red Amdor LED strip light installed on the right side of the interior cabinet door opening. The lighting will be controlled by an automatic door switch. FORWARD FACING PASSENGER SIDE OUTBOARD SEAT There will be one (1)forward facing, foldup seat provided at the passenger side outboard position in the crew cab. For optimal comfort, the seat will be a minimum of 15.00"from the front of the cushion to the face of the seat back and designed with EVC (elastomeric vibration control). The seat back will be an SCBA style with 90 degree back. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location. The seat will include the following features incorporated into the side roll protection system: • Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position. • A seat safety system will be included. When activated, this system will pretension the seat belt around the occupant to firmly hold them in place in the event of a side roll. Port Arthur Stock Saber Pumper The seat will be furnished with a 3-point, shoulder type seat belt. SEAT UPHOLSTERY All seat upholstery will be leather grain 36 oz dark silver gray vinyl resistant to oil, grease and mildew. The cab and tiller cab (if applicable) will have six (6) seating positions. AIR BOTTLE HOLDERS All SCBA type seats in the cab will have a "Hands-Free" auto clamp style bracket in its backrest. For efficiency and convenience, the bracket will include an automatic spring clamp that allows the occupant to store the SCBA bottle by simply pushing it into the seat back. For protection of all occupants in the cab, in the event of an accident, the inertial components within the clamp will constrain the SCBA bottle in the seat and will exceed the NFPA standard of 9G. There will be a quantity of five (5) SCBA brackets. SEAT BELTS All cab and tiller cab (if applicable) seating positions will have red seat belts. To provide quick, easy use for occupants wearing bunker gear, the female buckle and seat belt webbing length will meet or exceed the current edition of applicable NFPA and CAN/ULC - S515 standards. The 3-point shoulder type seat belts will include height adjustment. This adjustment will optimize the belts effectiveness and comfort for the seated firefighter. The 3-point shoulder type seat belts will be furnished with dual automatic retractors that will provide ease of operation in the normal seating position. The 3-point shoulder type belts will also include the ReadyReach® D-loop assembly to the shoulder belt system. The ReadyReach feature adds an extender arm to the D-loop location placing the D-loop in a closer, easier to reach location. Any flip up seats will include 3-point shoulder type belts only. To ensure safe operation, the seats will be equipped with seat belt sensors in the seat cushion and belt receptacle that will activate an alarm indicating a seat is occupied but not buckled. HELMET STORAGE PROVIDED BY FIRE DEPARTMENT NFPA 1900, 2024 edition, section 11.1.8.4.1 and CAN/ULC 515:2024 edition, section 5.2, requires a location for helmet storage be provided. There is no helmet storage on the apparatus as manufactured. The fire department will provide a location for storage of helmets. CAB DOME LIGHTS There will be four(4) dual LED dome lights with black bezels provided. Two (2) lights will be mounted above the inside shoulder of the driver and officer and two (2) lights will be installed and located, one (1) on each side of the crew cab. The color of the LED's will be red and white. Port Arthur Stock Saber Pumper The white LED's will be controlled by the door switches and the lens switch. The color LED's will be controlled by the lens switch. All dome lights on the apparatus will be illuminated per the current edition of applicable NFPA standards per seating position. PORTABLE HAND LIGHTS PROVIDED BY FIRE DEPARTMENT The hand lights are not on the apparatus as manufactured. The fire department will provide and mount these hand lights. CAB INSTRUMENTATION The cab instrument panel will include gauges, telltale indicator lamps, control switches, alarms, and a diagnostic panel. The function of the instrument panel controls and switches will be identified by a label adjacent to each item. Actuation of the headlight switch will illuminate the labels in low light conditions. Telltale indicator lamps will not be illuminated unless necessary. The cab instruments and controls will be conveniently located within the forward cab section, forward of the driver. The gauge assembly and switch panels are designed to be removable for ease of service and low cost of ownership. Gauges The gauge panel will include the following ten (10) black faced gauges with black bezels to monitor vehicle performance: • Voltmeter gauge (volts): o Low volts (11.8 VDC) • Amber telltale light on indicator light display with steady tone alarm o High volts (15.5 VDC) • Amber telltale light on indicator light display with steady tone alarm • Engine Tachometer (RPM) • Speedometer MPH (Major Scale), KM/H (Minor Scale) • Fuel level gauge (Empty - Full in fractions): o Low fuel (1/8 full) • Amber indicator light in gauge dial with steady tone alarm • Engine Oil pressure Gauge (PSI): o Low oil pressure to activate engine warning lights and alarms • Red indicator light in gauge dial with steady tone alarm • Front Air Pressure Gauges (PSI): o Low air pressure to activate warning lights and alarm • Red indicator light in gauge dial with steady tone alarm • Rear Air Pressure Gauges (PSI): o Low air pressure to activate warning lights and alarm • Red indicator light in gauge dial with steady tone alarm • Transmission Oil Temperature Gauge (Fahrenheit): o High transmission oil temperature activates warning lights and alarm • Amber indicator light in gauge dial with steady tone alarm • Engine Coolant Temperature Gauge (Fahrenheit): Port Arthur Stock Saber Pumper o High engine temperature activates an engine warning light and alarms • Red indicator light in gauge dial with steady tone alarm • Diesel Exhaust Fluid Level Gauge (Empty - Full in fractions): o Low fluid (1/8 full) • Amber indicator light in gauge dial Indicator Lamps To promote safety, the following telltale indicator lamps will be located on the instrument panel in clear view of the driver. The indicator lamps will be "dead-front" design that is only visible when active. The colored indicator lights will have descriptive text or symbols. The following amber telltale lamps will be present: • Low coolant • Trac cntl (traction control) (where applicable) • Check engine • Check trans (check transmission) • Air rest (air restriction) • DPF (engine diesel particulate filter regeneration) • HET (engine high exhaust temperature) (where applicable) • ABS (antilock brake system) • MIL (engine emissions system malfunction indicator lamp) (where applicable) • Regen inhibit (engine emissions regeneration inhibit) (where applicable) • Side roll fault (where applicable) • Front air bag fault (where applicable) • Aux brake overheat (auxiliary brake overheat) (where applicable) • The following red telltale lamps will be present: • Ladder rack down • Parking brake • Stop engine • The following green telltale lamps will be present: • Left turn • Right turn • Battery on • Ignition • Aux brake (auxiliary brake engaged) (where applicable) • The following blue telltale lamps will be present: • High beam Alarms Audible steady tone warning alarm: A steady audible tone alarm will be provided whenever a warning condition is active. Port Arthur Stock Saber Pumper Indicator Lamp and Alarm Prove-Out A system will be provided which automatically tests telltale indicator lights and alarms located on the cab instrument panel. Telltale indicators and alarms will perform prove-out for 3 to 5 seconds when the ignition switch is moved to the on position with the battery switch on. Control Switches For ease of use, the following controls will be provided immediately adjacent to the cab instrument panel within easy reach of the driver. All switches will have backlit labels for low light applications. Headlight/Parking light switch: A three (3)-position maintained rocker switch will be provided. The first switch position will deactivate all parking and headlights. The second switch position will activate the parking lights. The third switch will activate the headlights. Panel back lighting intensity control switch: A three (3)-position momentary rocker switch will be provided. Pressing the top half of the switch, "Panel Up" increases the panel back lighting intensity and pressing the bottom half of the switch, "Panel Down" decreases the panel back lighting intensity. Pressing the half or bottom half of the switch several times will allow back lighting intensity to be gradually varied from minimum to maximum intensity level for ease of use. Ignition switch: A three (3)-position maintained/momentary rocker switch will be provided. The first switch position will turn off and deactivate vehicle ignition. The second switch position will activate vehicle ignition and will perform prove-out on the telltale indicators and alarms for 3 to 5 seconds after the switch is turned on. A green indicator lamp is activated with vehicle ignition. The third momentary position will temporarily silence all active cab alarms. An alarm "chirp" may continue as long as alarm condition exists. Switching ignition to off position will terminate the alarm silence feature and reset function of cab alarm system. Engine start switch: A two (2)-position momentary rocker switch will be provided. The first switch position is the default switch position. The second switch position will activate the vehicle's engine. The switch actuator is designed to prevent accidental activation. Hazard switch will be provided on the instrument panel or on the steering column. Heater, defrost, and air conditioning control panel. Turn signal arm: A self-canceling turn signal with high beam headlight controls. Windshield wiper control will have high, low, and intermittent modes. Parking brake control: An air actuated push/pull park brake control. Chassis horn control: Activation of the chassis horn control will be provided through the center of the steering wheel. High idle engagement switch: A maintained rocker switch with integral indicator lamp will be provided. The switch will activate and deactivate the high idle function. The "OK To Engage High Idle" indicator lamp must be active for the high idle function to engage. A green indicator lamp integral to the high idle engagement switch will indicate when the high idle function is engaged. Port Arthur Stock Saber Pumper "OK To Engage High Idle" indicator lamp: A green indicator light will be provided next to the high idle activation switch to indicate that the interlocks have been met to allow high idle engagement. Custom Switch Panels The design of cab instrumentation will allow for emergency lighting and other switches to be placed within easy reach of the operator thus improving safety. There will be positions for up to four (4) switch panels in the lower instrument console and up to six (6) switch panels in the overhead visor console. All switches have backlit labels for low light conditions. 1 l 0 41:An • Diagnostic Panel A diagnostic panel will be provided and accessible while standing on the ground. The panel will be located inside the driver's side door left of the steering column. The diagnostic panel will allow diagnostic tools such as computers to connect to various vehicle systems for improved troubleshooting providing a lower cost of ownership. Diagnostic switches will allow ABS systems to provide blink codes should a problem exist. The diagnostic panel will include the following: • ENGINE/TRANSMISSION/ABS J1939 Diagnostic Port Port Arthur Stock Saber Pumper • ABS Diagnostic Switch and Indicator- The switch and amber indicator will allow access to diagnostic mode and display of standard ABS system fault blink codes that may be generated by the ABS system • DPF REGEN (Diesel Particulate Filter Regeneration Switch) (where applicable) will be provided to request regeneration of the engine emission system. An amber indicator will be provided on top of the switch that will illuminate in a "CHECK ENGINE" condition • REGEN INHIBIT (Diesel Particulate Filter Regeneration Inhibit Switch) (where applicable)will be provided that will request that regeneration be temporarily prevented. A green indicator will be provided on top of the Regen Inhibit switch that will illuminate when the Regen Inhibit feature is active. Regen Inhibit will be disabled upon cycling of the ignition switch to the off state. AIR RESTRICTION INDICATOR A high air restriction warning indicator light (electronic)will be provided. "DO NOT MOVE APPARATUS" INDICATOR A flashing red indicator light, located in the driving compartment, will be illuminated automatically per the current NFPA requirements. The light will be labeled "Do Not Move Apparatus If Light Is On." The same circuit that activates the Do Not Move Apparatus indicator will activate a pulsing alarm when the parking brake is released. SWITCH PANELS The built-in switch panels will be located in the lower console or overhead console of the cab. Switches will be rocker type with an indicator light, of which is an integral part of the switch. WIPER CONTROL Wiper control will consist of a two (2)-speed windshield wiper control with intermittent feature and windshield washer controls. The control will be located on the left side of the center instrument panel. CAB USB There will be four(4) USB terminations with a combination USB type A& C wired to battery direct power and provided per the following: • One (1)within reach of the driver • One (1) within reach of the passenger • Two (2) on the rear of the engine tunnel, one (1) each side. Battery direct loads cannot be load managed. SPARE CIRCUIT There will be one (1) pair of wires, including a positive and a negative, installed on the apparatus. The wires will have the following features: • The positive wire will be connected directly to the battery power. • The negative wire will be connected to ground. • Wires will be capable of carrying 15 amps. Port Arthur Stock Saber Pumper • Power and ground will terminate behind officer seat. • Termination will be with a 10-place bus bar with screws and removable cover. • Wires will be protected to meet the NFPA Automotive Fire Apparatus standard. Battery direct loads cannot be Load Managed. INFORMATION CENTER There will be a LCD display integral to the cab gauge panel provided that will display the following information: • Total distance • Trip distance • Total hours • Trip hours • PTO "A" hours • PTO "B" hours COLLISION MITIGATION There will be a HAAS Alert®, Model HA7 Responder-to-Vehicle (R2V) collision avoidance system provided on the apparatus. The HA7 cellular transponder module will be installed behind the cab windshield, as high and near to the center as practical, to allow clear visibility to the sky. The module dimensions are 5.40" long x 2.70" wide x 1.30" high, and operating temperature range is-40 degrees Celsius to 85 degrees Celsius. The transponder will be connected to the vehicle's emergency master circuit and battery direct power and ground. While responding with emergency lights on, the HA7 transponder sends alert messages via cellular network to motorists in the vicinity of the responding truck that are equipped with the WAZE app. While on scene with emergency lights on, the HA7 transponder sends road hazard alerts to motorists in the vicinity of the truck that are equipped with the WAZE app. The HA7 Responder-to-Vehicle (R2V) collision avoidance system will include the transponder and a 5 year cellular plan subscription. Activation of the HAAS Alert system requires a representative of the customer to accept the End User License Agreement (EULA) via an on-line portal. VEHICLE DATA RECORDER There will be a vehicle data recorder(VDR) capable of reading and storing vehicle information provided. The information stored on the VDR can be downloaded through a USB port mounted in a convenient location determined by cab model. A USB cable can be used to connect the VDR to a laptop to retrieve required information. The program to download the information from the VDR will be available to download on-line. Port Arthur Stock Saber Pumper The vehicle data recorder will be capable of recording the following data via hardwired and/or CAN inputs: • Vehicle Speed - MPH • Acceleration - MPH/sec • Deceleration - MPH/sec • Engine Speed - RPM • Engine Throttle Position - % of Full Throttle • ABS Event -On/Off • Seat Occupied Status -Yes/No by Position • Seat Belt Buckled Status -Yes/No by Position • Master Optical Warning Device Switch - On/Off • Internal clock syncs the time and date when a laptop is connected Seat Belt Monitoring System A seat belt monitoring system (SBMS)will be provided. The SBMS will be capable of monitoring up to 10 seating positions indicating the status of each seat position per the following: • Seat Occupied & Buckled = Green LED indicator illuminated • Seat Occupied & Unbuckled = Red LED indicator with audible alarm • No Occupant & Buckled = Red LED indicator with audible alarm • No Occupant & Unbuckled = No indicator and no alarm • FAULT = Blue LED indicator illuminated The SBMS will include an audible alarm that will warn that an unbuckled occupant condition exists and the parking brake is released, or the transmission is not in park. VEHICLE CAMERA SYSTEM There will be a color vehicle camera system provided with the following: • One (1) Analog High Definition (AHD) black camera located at the rear of the apparatus, pointing rearward, displayed automatically with the vehicle in reverse. The camera image will be displayed on a 7.00" High Definition (HD) display located in view of the driver on the dash. The display will include manual camera activation capability and audio from the active camera. The following components will be included: • One (1) HD700136DC, display • One (1) 1080p AHD rear camera • All necessary cables Camera Switcher A camera switcher is not required. Port Arthur Stock Saber Pumper ELECTRICAL POWER CONTROL SYSTEM A compartment will be provided in or under the cab to house the vehicle's electrical power and signal circuit protection and control components. The power and signal protection and control compartment will contain circuit protection devices and power control devices. Power and signal protection and control components will be protected against corrosion, excessive heat, excessive vibration, physical damage and water spray. Serviceable components will be readily accessible. Circuit protection devices, which conform to SAE standard, will be utilized to protect each circuit. All circuit protection devices will be sized to prevent wire and component damage when subjected to extreme current overload. General protection circuit breakers will be Type-I automatic reset (continuously resetting) and conform to SAE J553 or J258. When required, automotive type fuses conforming to SAE J554, J1284, J1888 or J2077 will be utilized to protect electronic equipment. Power control relays and solenoids will have a direct current (dc) rating of 125 percent of the maximum current for which the circuit is protected. Visual status indicators will be supplied to identify control safety interlocks and vehicle status. In addition to visual status indicators, audible alarms designed to provide early warning of problems before they become critical will be used. Voltage Monitor System A voltage monitor system will be provided to indicate the status of each battery system connected to the vehicle's electrical load. The monitor system will provide visual and audio warning when the system voltage is below optimum levels. Power and Ground Studs Spare circuits will be provided in the primary distribution center for two-way radio equipment. The spare circuits will consist of the following: • One (1) 12-volt DC, 30 amp battery direct spare • One (1) 12-volt DC ground and un-fused switched battery stud located in or adjacent to the power distribution center EMI/RFI Protection The electrical system proposed will include means to control undesired electromagnetic and radio frequency emissions. State of the art electrical system design and components will be used to ensure radiated and conducted EMI (electromagnetic interference) and RFI (radio frequency interference) emissions are suppressed at their source. The apparatus proposed will have the ability to operate in the electromagnetic environment typically found in fire ground operations. The contractor will be able to demonstrate the EMI and RFI testing has been done on similar apparatus and certifies that the vehicle proposed meets SAE J551 requirements. EMI/RFI susceptibility will be controlled by applying immune circuit designs, shielding, twisted pair wiring and filtering. The electrical system will be designed for full compatibility with low level control Port Arthur Stock Saber Pumper signals and high powered two-way radio communication systems. Harness and cable routing will be given careful attention to minimize the potential for conducting and radiated EMI-RFI susceptibility. ELECTRICAL All 12-volt electrical equipment installed by Pierce Manufacturing will conform to modern automotive practices. All wiring will be high temperature crosslink type. Wiring will be run, in loom or conduit, where exposed and have grommets where wire passes through sheet metal. Automatic reset circuit breakers will be provided which conform to SAE Standards. Wiring will be color, function and number coded. Function and number codes will be continuously imprinted on all wiring harness conductors at 2.00" intervals. Exterior exposed wire connectors will be positive locking, and environmentally sealed to withstand elements such as temperature extremes, moisture and automotive fluids. Electrical wiring and equipment will be installed utilizing the following guidelines: 1. All holes made in the roof will be caulked with silicon. Large fender washers, liberally caulked, will be used when fastening equipment to the underside of the cab roof. 2. Any electrical component that is installed in an exposed area will be mounted in a manner that will not allow moisture to accumulate in it. Exposed area will be defined as any location outside of the cab or body. 3. Electrical components designed to be removed for maintenance will not be fastened with nuts and bolts. Metal screws will be used in mounting these devices. Also, a coil of wire will be provided behind the appliance to allow them to be pulled away from mounting area for inspection and service work. 4. Corrosion preventative compound will be applied to all terminal plugs located outside of the cab or body. All non-waterproof connections will have this compound in the plug to prevent corrosion and for easy separation (of the plug). 5. All lights that have their sockets in a weather exposed area will have corrosion preventative compound added to the socket terminal area. 6. All electrical terminals in exposed areas will have silicon applied completely over the metal portion of the terminal. All lights and reflectors, required to comply with Federal Motor Vehicle Safety Standard #108, will be furnished. Rear identification lights will be recessed mounted for protection. Lights and wiring mounted in the rear bulkheads will be protected from damage by installing a false bulkhead inside the rear compartments. An operational test will be conducted to ensure that any equipment that is permanently attached to the electrical system is properly connected and in working order. The results of the tests will be recorded and provided to the purchaser at time of delivery. BATTERY SYSTEM There will be four(4) 12 volt Stryten/Exide®, Model 31 S950X5W, batteries that include the following features will be provided: • 950 CCA, cold cranking amps Port Arthur Stock Saber Pumper • 190 amp reserve capacity • High cycle • Group 31 • Rating of 3800 CCA at 0 degrees Fahrenheit • 760 minutes of reserve capacity • Threaded stainless steel studs Each battery case will be a black polypropylene material with a vertically ribbed container for increased vibration resistance. The cover will be manifold vented with a central venting location to allow a 45 degree tilt capacity. The inside of each battery will consist of a "maintenance free" grid construction with poly wrapped separators and a flooded epoxy bottom anchoring for maximum vibration resistance. BATTERY SYSTEM There will be a single starting system with an ignition switch and starter button provided and located on the cab instrument panel. MASTER BATTERY SWITCH There will be a master battery switch provided within the cab within easy reach of the driver to activate the battery system. An indicator light will be provided on the instrument panel to notify the driver of the status of the battery system. BATTERY COMPARTMENTS Batteries will be placed on non-corrosive mats and be stored in well ventilated compartments located under the cab and bolted directly to the chassis frame. The battery boxes will have reinforced sides. The battery compartments will be constructed of 0.188" steel plate and be designed to accommodate a maximum of three (3) group 31 batteries in each compartment. The battery hold-downs will be of a non-corrosive material. All bolts and nuts will be stainless steel. Heavy-duty, 2/0 gauge, color coded battery cables will be provided. Battery terminal connections will be coated with anti-corrosion compound. Battery solenoid terminal connections will be encapsulated with semi-permanent rubberized compound. JUMPER STUDS One (1) set of battery jumper studs with plastic color-coded covers will be included on the battery compartments. BATTERY CHARGER There will be a KussmaulTM, Chief Series Smart Charger 6012, product code 091-266-12-60, 60 amp battery charger with build-in touch screen display provided. The battery charger will be wired to the AC [AC Power Source] through a junction box located near the battery charger. Port Arthur Stock Saber Pumper The battery charger will be located in the cab behind the driver seat. REMOTE CONTROL PANEL - BATTERY CHARGER There will be a KussmaulTM, Model 091-94-12 universal display panel included. It will be wired directly to the chassis batteries. The battery charger indicator will be located on the driver's seat riser. AUTO EJECT FOR SHORELINE There will be one (1) KussmaulTM, Model 091-55-20-120, 20 amp 120 volt AC shoreline inlet(s) provided to operate the dedicated 120 volt AC circuits on the apparatus. The shoreline inlet(s) will include red weatherproof flip up cover(s). There will be a release solenoid wired to the vehicle's starter to eject the AC connector when the engine is starting. The shoreline(s)will be connected to Battery Charger and 120V cab & body receptacles. There will be a mating connector body supplied with the loose equipment. There will be a label installed near the inlet(s) that state the following: • Line Voltage • Current Ratting (amps) • Phase • Frequency The shoreline receptacle will be located on the driver side of cab, to the front of cab door. ALTERNATOR A Delco Remy®, Model 40SI, alternator will be provided. It will have a rated output current of 320 amps, as measured by SAE method J56. The alternator will feature an integral regulator and rectifier system that has been tested and qualified to an ambient temperature of 257 degrees Fahrenheit (125 degrees Celsius). The alternator will be connected to the power and ground distribution system with heavy-duty cables sized to carry the full rated alternator output. ELECTRONIC LOAD MANAGEMENT An electronic load management (ELM) system that monitors the vehicles 12-volt electrical system, and automatically reduces the electrical load in the event of a low voltage condition and by doing so, ensures the integrity of the electrical system. The ELM will monitor the vehicle's voltage while at the scene (parking brake applied). It will sequentially shut down individual electrical loads when the system voltage drops below a preset value. Two (2) separate electrical loads will be controlled by the load manager. The ELM will sequentially re- energize electrical loads as the system voltage recovers. Port Arthur Stock Saber Pumper HEADLIGHTS There will be four(4) JW Speaker®, Model EVO-X, 4" x 6" rectangular LED lights mounted in the front quad style, chrome housing on each side of the cab grille: • the outside light on each side will contain a part number 056***1 low beam module • the inside light on each side will contain a part number 056***1 high beam module • the headlights to include chrome bezels The low beam lights will be activated when the headlight switch is on. The high beam and low beam lights will be activated when the headlight switch and the high beam switch is activated. FRONT DIRECTIONALS The front directional's will be Whelen®, Model M62T, 4.31" high x 6.75" wide x 1.37" deep directional lights with amber LEDs. The lens color(s) to be clear. The directional's will be housed in the same common bezel as the front warning light and will be located above the headlights. The housing to be polished and the trim shall be chrome. The flash pattern of the directional lights will be Steady On (Arrow). INTERMEDIATE LIGHT There will be two (2) Weldon, Model 9186-8580-29, amber LED turn signal marker lights furnished, one (1) each side, in the rear fender panel. The light will double as a turn signal and marker light. CAB CLEARANCE/MARKER/ID LIGHTS There will be seven (7) amber LED lights provided per the following: • Three (3) amber LED identification lights will be installed in the center of the cab above the windshield. • Two (2) amber LED clearance lights will be installed, one (1) on each outboard side of the cab above the windshield as close to the outside of the apparatus as practical. • Two (2) amber LED clearance lights will be installed, one (1) on each side of the cab as high and far forward as practical. The lights will be installed without guards. FRONT CAB SIDE DIRECTIONAL/MARKER LIGHTS There will be two (2) Weldon, Model 9186-8580-29, amber LED lights installed front of the cab door, one (1) on each side of the cab. The lights will activate as marker lights with the headlight switch and directional lights with the corresponding directional circuit. REAR CLEARANCE/MARKER/ID LIGHTING There will be a three (3) LED light bar used as identification lights located at the rear of the apparatus per the following: Port Arthur Stock Saber Pumper • As close as practical to the vertical centerline • Centers spaced not less than 6.00" or more than 12.00" apart • Red in color • All at the same height There will be two (2) LED lights installed at the rear of the apparatus used as clearance lights located at the rear of the apparatus per the following: • To indicate the overall width of the vehicle • One (1) each side of the vertical centerline • As near the top as practical • Red in color • To be visible from the rear • All at the same height There will be two (2) LED lights installed on the side of the apparatus used as marker lights as close to the rear as practical per the following: • To indicate the overall length of the vehicle • One (1) each side of the vertical centerline • As near the top as practical • Red in color • To be visible from the side • All at the same height There will be two (2) red reflectors located on the rear of the truck facing to the rear. One (1) each side, as far to the outside as practical, at a minimum of 15.00", but no more than 60.00", above the ground. There will be two (2) red reflectors located on the side of the truck facing to the side. One (1) each side, as far to the rear as practical, at a minimum of 15.00", but no more than 60.00", above the ground. Per FMVSS 108 and CMVSS 108 requirements. REAR FMVSS LIGHTING The rear stop/tail and directional lighting included in the rear tail light housing will include the following: • Two (2) Whelen®, Model M62BTT, 4.30" high x 6.70" wide x 1.40" deep brake/tail lights with red LEDs • Two (2) Whelen, Model M62T, 4.30" high x 6.70"wide x 1.40" deep directional lights with amber LEDs. The directional lights will be set to Steady On (Arrow)flash pattern. • The lens color(s) to be clear. There will be two (2)Whelen Model M62BU, LED backup lights provided in the tail light housing. LICENSE PLATE BRACKET One (1) license plate bracket constructed of stainless steel will be provided at the rear of the apparatus. Port Arthur Stock Saber Pumper One (1)white LED light with chrome housing will be provided to illuminate the license plate. A stainless steel light shield will be provided over the light that will direct illumination downward, preventing white light to the rear. LIGHTING BEZEL There will be two (2)Whelen, Model M6FCV4P, four (4) place chromed ABS housings with Pierce logos provided for the rear M6 series stop/tail, directional, back up, scene lights or warning lights. BACK-UP ALARM A PRECO, Model 1040, solid-state electronic audible back-up alarm that actuates when the truck is shifted into reverse will be provided. The device will sound at 60 pulses per minute and automatically adjust its volume to maintain a minimum ten (10) dBA above surrounding environmental noise levels. CAB PERIMETER SCENE LIGHTS There will be four(4) Amdor, Model AY-LB-12HW0**, white LED strip lights provided, one (1) for each cab door that will meet NFPA ground lighting requirements. These lights will be activated automatically when the battery switch is on and the exit doors are opened or by the same means as the body perimeter scene lights. PUMP HOUSE PERIMETER LIGHTS There will be two (2) Amdor, Model AY-LB-12HW020, 350 lumens each, 20.00" LED weatherproof strip lights with brackets provided under the pump panel running boards, one (1) each side. If the combination of options in the vehicle does not permit clearance for a 20.00" light, a 12.00" version of the Amdor light will be installed. The lights will be controlled by the same means as the body perimeter lights. BODY PERIMETER SCENE LIGHTS There will be two (2) Amdor, Model AY-LB-12HW020, 350 lumens, 20.00" long, white LED's, 12 volt DC lights provided at the rear step area of the body, one (1) each side shining to the rear. The perimeter scene lights will be activated when the parking brake is applied. STEP LIGHTS There will be four(4) white LED, step lights provided. One (1) step light will be provided on each side, on the front compartment face and two (2) step lights at the rear to illuminate the tailboard. These step lights will be actuated when the ignition switch is on and the parking brake is set. All steps on the apparatus will be illuminated per the current edition of applicable NFPA standards. 12 VOLT LIGHTING There will be one (1) HiViz Model FT-B-46*-*, 2.56" high x 46.00" long x 2.45" deep 13,306 effective lumens 12 volt DC light with white LEDs provided as far forward as possible on the front cab roof centered. The LEDs will be configured with a combination of flood and spot optics. The painted parts of the light housing and brackets to be black. Port Arthur Stock Saber Pumper The scene LEDs will be activated by a switch at the driver's side switch panel and by a switch at the passenger's side switch panel. The white LEDs may be load managed when the parking brake is applied. 12 VOLT DC SCENE LIGHTS There will be one (1)Whelen® Model PCPSM2*, 16,000 lumens 12 volt DC powered light(s)with white LEDs installed on the cab located, behind driver door, above side crew cab window, upper portion of cab. The surface mount housing(s)will be provided with a chrome cover. The light(s)will be activated by a switch at the driver's side switch panel and by a switch at the left side pump panel. The light(s) may be load managed when the parking brake is applied. 12 VOLT DC SCENE LIGHTS There will be one (1) Whelen® Model PCPSM2*, 16,000 lumens 12 volt DC powered light(s)with white LEDs installed on the cab located, behind officers door, above side crew cab window, upper portion of cab. The surface mount housing(s)will be provided with a chrome cover. The light(s)will be activated by a switch at the driver's side switch panel and by a switch at the left side pump panel. The light(s) may be load managed when the parking brake is applied. 12 VOLT LIGHTING There will be one (1)Whelen® Model PCPSM2*, 16,000 lumens 12 volt DC surface mount light(s) installed on the body of the apparatus located, on side sheet above LS1 in painted housing. The light(s)will include housing(s) with a chrome cover. The light(s) will be controlled by the same control that has been selected for the driver's side scene light(s). The light(s) may be load managed when the parking brake is applied. 12 VOLT LIGHTING There will be one (1) Whelen® Model PCPSM2*, 16,000 lumens 12 volt DC surface mount light(s) installed on the body of the apparatus located, on side sheet above RS1 in painted housing. The light(s)will include housing(s)with a chrome cover. The light(s)will be controlled by the same control that has been selected for the passenger's side scene light(s). Port Arthur Stock Saber Pumper The light(s) may be load managed when the parking brake is applied. HOSE BED LIGHTS There will be white 12 volt DC LED light strips with stainless steel protective cover, provided to light the hose bed area. Hose Bed lights will meet the photometric levels listed in the current edition of applicable NFPA standards for Hose Bed lighting requirements. • Light strip(s)will be installed along the upper edge of the left side of the hose bed. • Light strip(s)will be installed along the upper edge of the right side of the hose bed. The lights will be activated by a cup switch at the rear of the apparatus no more than 72.00" from the ground. REAR SCENE LIGHTS There will be two (2) Whelen® Model PEL2*, 12 volt DC white LED scene lights with chrome trim installed at the rear of the apparatus, rear of truck, mid-height, one each side. The lights will be controlled by a switch at the driver's side switch panel and by a cup switch at the driver's side rear bulkhead. WALKING SURFACE LIGHT There will be Model FRP, 4.00" round black 12 volt DC LED floodlight(s)with bolt mount provided to illuminate the entire designated walking surface on top of the body. The light(s)will be activated when the body step lights are on. WATER TANK Booster tank will have a capacity of 750 gallons and be constructed of polypropylene plastic by United Plastic Fabricating, Incorporated. Tank joints and seams will be nitrogen welded inside and out. Tank will be baffled in accordance with the current edition of applicable NFPA standards. Baffles will have vent openings at both the top and bottom to permit movement of air and water between compartments. Longitudinal partitions will be constructed of 0.38" polypropylene plastic and will extend from the bottom of the tank through the top cover to allow for positive welding. Transverse partitions will extend from 4.00" off the bottom of the tank to the underside of the top cover. All partitions will interlock and will be welded to the tank bottom and sides. Tank top will be constructed of 0.50" polypropylene. It will be recessed 0.38" and will be welded to the tank sides and the longitudinal partitions. Tank top will be sufficiently supported to keep it rigid during fast filling conditions. Port Arthur Stock Saber Pumper Construction will include 2.00" polypropylene dowels spaced no more than 30.00" apart and welded to the transverse partitions. Two (2) of the dowels will be drilled and tapped (0.50" diameter, 13.00" deep) to accommodate lifting eyes. A sump that will be sized dependent on the tank to pump plumbing will be provided at the bottom of the water tank. Sump will include a drain plug and the tank outlet. Tank will be installed in a fabricated cradle assembly constructed of structural steel. Sufficient crossmembers will be provided to properly support bottom of tank. Crossmembers will be constructed of steel bar channel or rectangular tubing. Tank will "float" in cradle to avoid torsional stress caused by chassis frame flexing. Rubber cushions, .50" thick x 3.00" wide, will be placed on all horizontal surfaces that the tank rests on. Stops or other provision will be provided to prevent an empty tank from bouncing excessively while moving vehicle. Mounting system will be approved by the tank manufacturer. Fill tower will be constructed of 0.50" polypropylene and will be a minimum of 8.00"wide x 14.00" long. Fill tower will be furnished with a 0.25" thick polypropylene screen and a hinged cover. • An overflow pipe, constructed of 4.00" schedule 40 polypropylene, will be installed approximately halfway down the fill tower and extend through the water tank and exit to the rear of the rear axle. SLEEVE PLUMBING THROUGH TANK Two (2) sleeves will be provided in the water tank for a 3.00" pipe to the rear. WATER TANK RESTRAINT A heavy-duty water tank restraint will be provided. HOSE BED The hose bed will be fabricated of 0.125"-5052 aluminum with a nominal 38,000 psi tensile strength. The hose bed will be as low as practical. Upper and rear edges of side panels will have a double break for rigidity. The upper area at the rear of the hose bed will be covered with brushed stainless steel to prevent damage to painted surface when hose is removed. Flooring of the hose bed will be removable aluminum grating with the top surface corrugated to aid in hose aeration. The grating slats will be a minimum of 0.50" x 4.50" with spacing between slats for hose ventilation. Port Arthur Stock Saber Pumper A cross divider will be provided at the front of the hose bed before the tank transitions from the lower section to the upper section. The divider will run from the top of the side sheet down below the hose bed grating. The inside of the hose bed will be painted. The inside of the cargo area above the pump will be painted. Hose bed will accommodate 250 2.5 250 2.5 800 3" 1200 4" 400 1.75 Left to right. HOSE BED DIVIDER Four (4) hosebed dividers will be furnished for separating hose. Each divider will be constructed of a 0.25" brushed aluminum sheet. Flat surfaces will be sanded for uniform appearance or constructed of brushed aluminum. Divider will be fully adjustable by sliding in tracks, located at the front and rear of the hose bed. Divider will be held in place by tightening bolts, at each end. Acorn nuts will be installed on all bolts in the hose bed which have exposed threads. HOSE BED DEFLECTOR A hose bed wind deflector will be provided at the front of the hose bed. The cover will be 30.00" long x full width of the hose bed. The cover will be constructed of .19" bright aluminum treadplate, hinged to the hose bed cross divider with a full length stainless steel piano hinge and resting on the hose bed dividers and side sheets. The cover will have a 1.00" upward "Lazy Bend" at the rear with additional bracing underneath for stiffening. A chrome grab handle will be provided in the rear center of the cover to assist in opening and closing. Pneumatic cylinders will be provided to hold the deflector in the open position. The cover will be labeled "NO STEP" using 3.00" lettering. Swell latches will be provided at the outboard rearward corners. A single pair of black nylon Velcro® straps will be provided towards the rear at the top of the hose bed to retain hose within the hose bed. A heavy duty 2" black nylon webbing will be installed at the rear of the hose bed and wrap over the top of the hose bed with seat belt buckles at the top. The seat belt buckles will be provided with a metal bar, to connect the buckles, and an attached web strap, to allow a single pull release. At the bottom of the webbing, hinged style seat belt buckle will be provided. If a strap is provided, the color of the strap will be black. RUNNING BOARDS Running boards will be fabricated of 0.125" bright aluminum treadplate. Port Arthur Stock Saber Pumper Each running board will be supported by a welded 2.00" square tubing and channel assembly, which will be bolted to the pump compartment substructure. Running boards will be 12.75" deep and spaced 0.50" away from the pump panel. A splash guard will be provided above the running board treadplate. TAILBOARD The tailboard will also be constructed of .125" bright aluminum treadplate and spaced .50"from the body, as well as supported by a structural steel assembly. The tailboard area will be 12.00" deep and full width of the body. The outboard sides of the tailboard will be angled at 45 degrees beginning at the point where the body meets the tailboard at the outboard edge angling rearward to the rear edge of the tailboard. The exterior side will be flanged down and in for increased rigidity of tailboard structure. REAR WALL, SMOOTH ALUMINUM/BODY MATERIAL The rear wall body material will be painted. Unpainted aluminum overlays will be provided to allow for chevron application and to provide continuously smooth rear wall panels. The rear wall will be flush. REAR TOW EYES Two (2) tow eyes, which are an integral part of the body mounting substructure, will be installed below the rear of the truck. The tow eyes will be of adequate strength to allow the truck to be pulled from the eyes. REAR TOW BAR One (1) tow bar will be installed under the tailboard. The tow bar assembly will be designed and positioned to allow up to a 30-degree upward angled pull of 17,000 Ib, or a 20,000 lb straight horizontal pull in line with the centerline of the vehicle. The tow bar design will have been tested and evaluated using finite element analysis techniques. RUNNING BOARD HOSE RESTRAINT A pair of 2.00" wide black nylon straps with Velcro fasteners will be provided for each hose tray to secure the hose during travel. Two (2) hose trays will be located one (1) in each side running board. HOSE TRAY Two (2) hose trays will be made free floating one (1) in each side running board. The tray(s)will be flanged and drop in from the top. The front and rear corners at the base of tray will be tapered. No fasteners will be used to secure the tray(s). Capacity of the tray will be 90' of 1.5". Port Arthur Stock Saber Pumper Rubber matting will be installed on the floor of the tray to provide proper ventilation. Drain holes will be provided. COMPARTMENTATION Body and compartments will be fabricated of 0.125", 5052-H32 aluminum. Side compartments will be an integral assembly with the rear fenders. Circular fender liners will be provided for prevention of rust pockets and ease of maintenance. Side compartment flooring will be of the sweep out design with the floor higher than the compartment door lip. The side compartment door opening will be framed by flanging the edges in 1.75" and bending out again 0.75" to form an angle. Drip protection will be provided above the doors by means of bright aluminum extrusion, formed bright aluminum treadplate or polished stainless steel. The top of the compartment will be covered with bright aluminum treadplate rolled over the edges on the front, rear and outward side. These covers will have the corners welded. Side compartment covers will be separate from the compartment tops. Front facing compartment walls will be covered with bright aluminum treadplate. All screws and bolts which protrude into a compartment will have acorn nuts on the ends to prevent injury. UNDERBODY SUPPORT SYSTEM Due to the severe loading requirements of this pumper a method of body and compartment support suitable for the intended load will be provided. The backbone of the support system will be the chassis frame rails which is the strongest component of the chassis and is designed for sustaining maximum loads. Forward to the rear axle, the support system will include "L"-shaped support members bolted to the chassis frame rails. These welded support members will include vertical formed channels, horizontal structural channels, and support gussets. These parts extend from the chassis frame outward underneath the body. Rearward to the rear axle, the body support system will include two rearward facing "L"-shaped support members bolted to the chassis frame rails. These support members will be connected to the two body supporting crossmembers forming a boxed foundation for the rear body support system. Steel upper platform decks will be mounted on the top of these support members to create a floating substructure which will result in a 500 lb equipment support rating per lower compartment. Port Arthur Stock Saber Pumper