Loading...
HomeMy WebLinkAboutPR 18378: PURCHASE OF FIRE HYDRANTS FOR UTILITY OPERATIONS WITH HD SUPPLY MEMORANDUM CITY OF PORT ARTHUR UTILITY OPERATIONS DEPARTMENT TO: John A. Comeaux P.E., City Manager FROM: John A. Tomplait, Assistant Director of Utility Operations DATE: June 17, 2014 RE: Proposed Resolution No. 18378 RECOMMENDATION I recommend that the City Council approve Proposed Resolution No. 18378 authorizing the purchase of Fire Hydrants as needed, from HD Supply of Beaumont, Texas, in the estimated amount of $162,641.65 (at the unit prices shown below) for the Utility Operations Department Water Distribution Division. BACKGROUND Several years ago, the City standardized on the American Flow Control (American Darling) fire hydrant manufactured in Beaumont, Texas. This was done not only to reduce the inventory requirements and training of our personnel on maintenance of multiple FH manufacturers, but because the AFC hydrant (manufactured in Beaumont) is widely regarded as one of the best units available. AFC sells its product through distributors exclusive to geographic areas. Their current distributor for our area (sole source) is HD Supply in Beaumont. This procurement is exempt from the bid process under Texas Local Government Code Section 252.022, General Exemptions (7A), a procurement of items that are available from only one source, including items that are available from one source because of patents, copyrights, secret processes, or natural monopolies. HD Supply has provided current Not-to-Exceed (NTE) quotes below for various hydrants: Depth NTE 2013 Qty. of Bury Price Price n% AFC B84 Hydrant w/Storz.Nozzle 30 3.5' $1,949.39 $1,858.50 4.9% 30 4.5' $2,028.43 $1,935.00 4.8% 15 6' $2,147.27 $2,049.76 4.7% 5 4.5' duel storz $2,219.60 N/A The price increases shown are typical increases we have seen for other materials over this time frame. BUDGET/FISCAL EFFECT This material,is maintained in inventory at the Utility Operations warehouse and is charged to the apprdpriate budget account as consumed, normally 410-1253-532.35-00 (Water System Maintenance), and occasionally to a billed (reimbursable) project account. The estimated maximum total award is $162,641.65, but may vary along with the quantity as funding allows and needs require. SUMMARY I recommend that the City Council approve Proposed Resolution No. 18378. P. R.No. 18378 06/17/14jt • RESOLUTION NO. A RESOLUTION AUTHORIZING THE EXECUTION OF A CONTRACT FOR THE PURCHASE OF FIRE HYDRANTS FOR THE UTILITY OPERATIONS DEPARTMENT WITH HD SUPPLY OF BEAUMONT, TEXAS, IN THE TOTAL NOT TO EXCEED AMOUNT OF $162,641.65 (UNIT PRICES AS SHOWN IN THE ATTACHED BID TABULATION). FUNDS ARE AVAILABLE IN ACCOUNT NO. 410-1253-532.35-00. WHEREAS, the Utility Operations Department routinely installs and replaces fire hydrants throughout the City; and, WHEREAS,the City Standard for fire hydrants is the American Flow Control American Darling B-84B (latest version or change in specifications), manufactured in Beaumont, Texas; and, WHEREAS, American Flow Control sells its product through distributors exclusive to geographic areas; and, WHEREAS, the current AFC distributor for our area (sole source) is HD Supply in Beaumont; and, WHEREAS, this procurement is exempt from the bid process under Texas Local Government Code Section 252.022, General Exemptions (7A), a procurement of items that are available from only one source, including items that are available from one source because of patents,copyrights, secret processes, or natural monopolies; and, WHEREAS, the sole source for bids has been evaluated by Utility Operations and Purchasing(bid tabulation attached as Exhibit A),NOW THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PORT ARTHUR: THAT, the City Manager of the City of Port Arthur is hereby authorized and directed to execute, on behalf of the City of Port Arthur, a contract between the CITY OF PORT ARTHUR P. R.No. 18378 06/17/14jt Page 2 of 3 and HD SUPPLY,for the unit prices shown in the Bid Tabulation(attached as Exhibit"A"), in a not to exceed amount of$162,641.65, as shown in the contract attached as Exhibit"B"; and, THAT, this contract can be renewed upon mutual consent for an additional twelve (12) month period, and the City can terminate this contract at its convenience with thirty (30) days written notice;and, THAT,funding for this material is provided for in the Utility Operations budget; and, THAT a copy of the caption of this resolution be spread upon the minutes of the City Council. READ, ADOPTED AND APPROVED THIS day of , 2014 at a Regular Meeting of the City Council of the City of Port Arthur, Texas, by the following vote: AYES: Mayor Councilmembers: NOES: Deloris Prince Mayor ATTEST: APPROVED AS TO FORM: //.x!44` Sherri Bellard Valecia iczenoo City Secretary City Attorney P.R.No. 18378 06/17/14jt Page 3 of 3 APPROVED FOR ADNIINISTRATION: ) John A. Comeaux, P.E. Shawna Tubbs, CPPB Interim City Manager Purchasing Manager John A. Tomplait Assistant Director of Utilities APPROVED AS TO AVAILABILITY OF FUNDS: Deborah Echols Director of Finance Account No. 410-1253-532.85-00 P.R.No. 18378 06/17/14 Exhibit "A" (Bid Tabulation) P. R. No. 18378 06/17/14 BID TABULATION FIRE HYDRANTS Quote submitted by HD Supply, of Beaumont, Texas. Depth Not To Exceed of Bury Price AFC B84 Hydrant w/Storz nozzle 3.5' $1,949.39 4.5' $2,028.43 6' $2,147.27 AFC B84 w/duel Storz pumper nozzle 4.5' $2,219.60 P. R.No. 18378 06/17/14 Exhibit "B" P. R.No. 18378 06/17/14 PURCHASING CONTRACT AGREEMENT THIS AGREEMENT is made this the of , 2014, by and between an individual, firm partnership or corporation, HD SUPPLY, of Beaumont, Texas hereinafter called "Vendor", and the City of Port Arthur, a municipal corporation organized under the laws of the State of Texas, hereinafter called the "Owner" or"City". WITNESSETH: That for and in consideration of the payments, terms, conditions and agreements set forth herein, Owner and Vendor agree as follows: 1. The term of this Contract shall be stated in the Notice. to Proceed. This Agreement can be renewed with mutual consent for an additional twelve (12) month period. The City can terminate this contract at its convenience which includes, but not limited to, funding not being available in any budget cycle with thirty (30) days written notice. 2. The Vendor will provide American Flow Control B84 Storz Fire Hydrants, as delineated and submitted in their proposal on June 17, 2014. 3. During the term of this Contract, the Vendor will furnish all of the materials and supplies, as stated in the specifications, described as: American Flow Control B84 5" Storz Fire Hydrants 4. The Vendor agrees to deliver all materials on an as-needed basis during the term of this contract, in a not-to-exceed maximum amount of $162,641.65 ($1,949.39/3.5' bury, $2,028.43/4.5' bury, & $2,147.27/6' bury, $2,219.60/4.5' bury duel storz) as shown in the quote. 5. The term "Contract Documents" means and includes the following: A. Agreement B. Specifications; quote C. Notice to Proceed 6. This Agreement shall be binding upon all parties hereto and their respective heirs, executors, administrators, successors and assigns. P.R.No. 18378 06/17/14 IN WITNESS WHEREOF, the parties hereto have executed, or caused to be executed by their duly authorized officials, this Agreement in two (2) copies each of which shall be deemed an original on the date first above written. SIGNED AND AGREED to on the day of ,, 2014. WITNESS: CONTRACTOR: HD Supply SIGNED AND AGREED to on the day of , 2014. WITNESS: CITY OF PORT ARTHUR: City Secretary City Manager FIRE HYDRANT SPECIFICATIONS FOR THE CITY OF PORT ARTHUR UTILITY OPERATIONS DEPARTMENT GENERAL These specifications are for the furnishing of Fire Hydrants for the City of Port Arthur Utility Operations Department. Bid price shall be F.O.B., 111 H.O. Mills Blvd., Port Arthur, TX 77640. Fire Hydrants shall be as manufactured by American Flow Control, Model B84 (latest model) with 5" STORZ connection, and shall conform to requirements and tests of AWWA Standard for Dry Barrel Fire Hydrants C502 (latest revision), as they pertain to the design, component materials, construction and manufacture, except as modified or supplemented hereinafter: SUPPLEMENTARY DETAILS 1. The operating nut shall be bronze, non-rising, and pentagonal in shape measuring 1-1/4" from point to flat. Pentagon shall have a depth of at least one and one quarter inch (1-1/4"). The hold down nut shall incorporate a resilient weather seal protecting the operating mechanism from the elements. The direction of opening shall be counter-clockwise with an arrow clearly embossed near the operating nut to so indicate. 2. A lubrication chamber shall be provided, sealed top and bottom with "0" rings. The design shall be such that the thrust collar and the threaded operating parts are automatically lubricated each time the hydrant is cycled. There shall not be less than two (2) "0" rings separating the oil reservoir from the waterway and that portion of the stem contacting these "0" rings shall be sleeved with bronze. An anti-friction device shall be in place above the thrust collar to further minimize operating torque. 3. The hydrant bonnet shall be attached to the upper barrel by not less than eight(8)bolts and nuts. 4. Hydrants shall be'three-way', having two (2)2-1/2" hose nozzles with National Standard Threads and one (1) pumper nozzle with 5" STORZ nozzle connection, as stated below. Nozzles shall have bayonet connection, or thread counter-clockwise, into hydrant barrel utilizing "0" ring pressure seals. A suitable nozzle lock shall be in place to prevent inadvertent nozzle removal. 5. Hydrants shall be 'traffic-model' having upper and lower barrels joined approximately 2" above the ground line by a breakable flange. This flange shall employ not less than (8) bolts. The ground line, which shall be clearly embossed on the lower barrel, shall be from the centerline of the lowest nozzle. Traffic feature shall be designed for easy 360° rotation of nozzle section during field installation. 6. The stem shall be two-piece, not less than 1-1/4" diameter (excluding threaded or machined areas) and shall be connected by a breakable stem coupling near the ground line flange, which shall be of metal similar to the stem to minimize galvanic action at this point. Screws, pins, bolts or fasteners used in conjunction with the stem coupling shall be stainless steel. 7. Inside diameter of hydrant barrel shall not be less than six and one eighth inches(6W). 8. Main valves shall be'compression type', closing with the pressure and shall be not less than 5-W' diameter. It shall be designed so that removal can be accomplished without excavating. Composition of the main valve shall be molded rubber or neoprene and shall be not less than 1" thick. 9. Hydrants shall be equipped with not less than two (2) drain ports and four(4) drain outlets, which drain the barrel when the hydrant is closed and seal shut when the hydrant is opened. 10. The upper valve plate, seat ring and drain ring (or shoe bushing) must be bronze (ASTM B-62) and work in conjunction to form an all bronze drain way. 11. The bronze seat ring shall thread into a bronze drain ring (or shoe bushing) providing bronze-to- bronze connection. Seat ring seals shall be"0"rings. 12. The 6" shoe connection shall be mechanical joint having ample blocking pads for sturdy setting and two (2) strapping lugs to secure hydrant to piping. A minimum of six (6) bolts and nuts is required to fasten the shoe to the lower barrel. Jun-17-2014 03:09 PM HD Waterworks 4098660955 2/2 06/12/2014 07:80 4099838561 WAREHOUSE PAGE 03/03 13. The interior of the shoe, including the lower valve plata and stem cap nut, shall have a protective coating of a two-part thermosetting epoxy of at least 4 mils. if a stem cap nut is utilized, a stainless steel lock washer or similar non-corrosive device must lock it in place. 14. Bidder must furnish: 1)flow data indicating friction loss In PSI at the flow rate of 1000 GPM from the pumper nozzle,such friction loss must not exceed 3 PSI,2)hydrant shall be warranted by the manufacturer against defects In material or workmanship for a period of ten (10) years from the date of manufacture,and 3)the manufacturing facility for the hydrant must have current ISO 0001 certification. 15. The City Standard for flrs hydrants is: American/Darling 5%"B-84-B-5 with bronze upper valve plate and epoxy coated base. Hydrants delivered to the City will be carefully examined and failure to comply With any of the above requirements Is sufcient cause for rejection. Such hydrants must be removed from City premises at supplier's expense. Bid price shall be F.O,B.,111 H.O.Mills Blvd., Port Arthur,TX 77840. The term of this contract shall be for a period of twelve(12) months. However,the Ciitijr reserves the right to extend the contract In its exact same terms at the original bid amount for an additional twelve(12) months with mutual consent. Although the City plans to purchase approximately fifty(60) hydrants during the year(annual contract will begin with the contract award),there is no obligation to buy this exact quantity. The following estimated quantities are to establish a basis for the comparison of bids. No one-time delivery will be accepted. Minimum order shell be for ten(10)hydrants, Lteg_lbOn era - .. . 30 FH--3.6'bury w/Storz pumper nozzle: $ l 9 9. 9 leach 30 FH—4.5'bury w/Storz pumper nozzle; $, 69 leach 15 FH—6'bury w/$tort pumper nozzle: $ .2 1 9, 2 7 .each 2 / 6 PH—4,5'bury w1 dual Storz pumper nozzles: $ 9 ' " ( ) leach